Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹63.2 LAccepted-AOC B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | L1 | Accepted-AOC The lowest e-tenderer | |
| 2 | L2₹84.8 L+₹21.6 L (34.1%)Rejected-Finance | L2 | Rejected-Finance Not the lowest e-tenderer |
Tender Value
₹73.5 L
EMD Value
₹1.4 L
Closing Date
26 Dec 2019, 6:00 pmClosed
Commander Works Engineer (Army) Mumbai
Commander Works Engineer (Army) 24 Assaye Building, Colaba Mumbai-400 005
SPECIAL REPAIR TO BLDG NO P25 OR MD ACCN AT MALAD COMPLEX OF COD MUMBAI
2019_MES_302949_1
83818/N/E8
Open Tender
Civil Works
Item Rate
270 days
GE NORTH SANTACRUZ
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE NORTH SANTACRUZ
₹1.4 L
23 Jan 2020
2 Dec 2019
27 Dec 2019
2 Dec 2019
26 Dec 2019
16 Dec 2019
2 Dec 2019 - 26 Dec 2019
Amount
Schedule 'A' Part I M&L for excavation over areas n .exc 1.50 mtr deep and getting out in hard/dense soil complete all as specified and as directed by Engineer-In-Charge.
Removing excavated soil outside MD land complete all as specified and as directed by Engr-In-Charge
Returning, filling in, including spreading, levelling, watering and well remming in layers n exc 25 cm, in soil.
Demolition of brick work built in any cement mortar or in any position complete all as specified and as directed by Engineer-In-Charge.
M&L for Brick work with sub class 'B' brick straight or curved on plan exc 6 mtr mean raddius built in CM 1:6 complete all as specified and as directed by Engineer-In-Charge.
M&L for cement concrete 1:4:8 type D2 using 40mm graded aggregate and filling mass concrete in foundation complete all as specified and as directed by Engineer-In-Charge.
M&L for hardcore of broken stone or boulder of guage exc 63mm but n. exc 100mm deposited, spread and levelled in layers n.exc 15 cm thick, watered and rolled /rammed to a true ssurface complete all as specified and as directed by Engineer-In-Charge.
Demolition of re-inforced cement concrete (re-inforced cut as required to facilotate demolition) in any position ( Beam, landing Chajja, RCC overhead water tank and Roof slab etc ) ground floor/ other than ground floor complete all as specified and as directed by Engineer-In-Charge.
Disconnecting existing PVC water storage tank of capacity exc 500 ltrs & not exc1000 Ltrs, setting aside (or lowering if required) for repairs. cleaning, etc and hoisting if required reconnecting and refixing in position complete all as specified and directed.
Demolition of cement concrete / cement lime concrete/mud faska (unreinforced in roof and terrace other than ground floor) any description alongwith existing treatmentg and removal of rubbish outside MD Land complete all as specified.
M&L for preparation Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size)with ShaliPlast LW++ over P.V.C. sheet 1m x 1m x 400micron, finished with 12mm cement plaster 1:3 (1 cement : 3 coarse sand) with ShaliPlast LW++ and a ShaliCrete admixed coat of neat cement and rounding the edge sand making and finishing the outlet complete.
M&L for 50mm thick (average thickness) PCC (1:2:4), type B1, using 20mm graded stone aggregate as levelling course laid to slope as required, finished even & fair without using extra cement. complete all as specified and directed.
M&L for rendering 10 mm thick cement plaster in cement mortar (1:3) on roof slab/ canopies/chajjas with water proofing compound @ 3% by weight of cement or as per manufacturer's instructions and make surfaces to receive water proofing treatment, finished even and smooth without using extra cement complete all as specified and directed. (Note:- water proofing compound will be measured and paid for separetaly as supply only)
M&L preparation of surfaces by removing bitumen based water proofing treatment completely removed by mechanical scarification or by any other effective mechanical means and prepare the normal surface throughly by cleaning , washing and removing dust, dirt oil, grease, any loose particles etc and applying one coat of Dr FIXIT prime seal diluted with water in the ratio 2:1 and dry minimum 2-3 hours and apply Dr FIXIT new coat or equivalent in three coats at the rate 0.50 litre per sqm in each coat and dry 6 to 8 hrs after each coat with and including put woven glass fibre mesh 2-5 mm x 2.5mm between first coat and second coat complete all as specified and as directed
Supply only integral water proofing compound (ISI Marked)
Taking down steel window/ventilator frame with shutters n. exc 1.5 sqm each (without taking off shutters from the frames).
M&L for 20-25 mm thick machine cut cudappa stone slab in jambs / cills / soffits of window / ventilator as in frame work to support for aluminium section, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete over backing coat 10 mm thick in CM (1:4)
S&F aluminium powder coated coloured sections for sliding or openable windows, ventilators, doors, partions etc including fabrication of frame & shutters and fixing with necessary lugs, cleats, rollers, handles, locking arrangement etc including all accessories such as glazing clips and rubber beadings for fixing glass panes / wire mesh in frame complete all as spd and directed by Eng in Charge. Note:- (i) Glass panes & wire mesh will be measured & paid separately.
S&F 4 mm thick figured glass, pin head type in square n.exc 0.5 sqm each pane
S&F in repair aluminium alloy wire mesh 0.45 mm nominal dia of wire and average width of aperture 1.4 mm fixed with aluminium wire staples
S&F anodised aluminium grill, square/rectangular or similar section, fixed with channel of size 38mm x 12mm x 1.3mm "DECO GRILL of Dg -101"of size7 x 4.5mm thick complete all as specified and as directed.
Taking down of chowkats or frames exc 1.5sqm but n exc 4 sqm with shutters (with out taking off shutters from the frames).
S & F IInd class HW solid, straight chowkats and frames, rought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints.
M & L for preparing surfaces of wood and wood based materials, and treating back of chowkats etc but n exc 0.5 sq m but n exc 0.5 sq. M each with tar or coal tar black paint
S & F mild steel hold fast and similar small articles conforming to Fe 290-0 or E 165
M&L for cement concrete type C1 1:3:6 (20mm graded aggregate) for hold fasts complete all as specified.
S&F solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube, fixing in opening as per specification & manufacturer's instructions
S & F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheet s for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded /sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, all as per spd and directed by Eng-in-Charge
S&F 35mm thick second class hard wood factory made plain framed panelled shutters (two panes) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board medium density with commercial veneering both face. The size of rail shall be as per IS 1003 (Part-I) kiln seasoned and chemically pressure treated all as specified and directed.
S & F 35 mm thick Iind class hardwood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc; sizes of members of shutter all as specified
S & F butt hinges 100 mm size ,stainless steel type B-21
S&F extruded aluminium alloy handles fabricated types, anodised, each 150 mm long
S&F aluminium tower bolt 150 mm long of extruded section.
S & F 30mm thick "RAJSHRI" brand factory made wire mesh solid pvc door shutter consisting of frame made out M.S. tubes of 19 gauge thickess and size of 19mm x 19mm for 15mm x 15mm for top, lock & bottom rails, M.S. frame shall have a coat of metal primer of approved make and manufacturer. 19mm x 19mm M.S. square tubes shall be covered with heat moulded plain sheet ' C' channel made from 5mm plus minus 0.25 mm thick PC sheet of Density 600 Kg/ cbm Manufactured by an ISO -9001-2015 certified company, of size 30mm thickness, 90mm width out of which 75mm shall be flat and 15mm shall be bent in 90 degree angle on either side forming stiles, one of the 90 degree bend edge is cut from stiles as well as rails to nail from inner side of door to hide wiremesh fixing steel screws, 5mm plus minus 0.25 thick 115 mm wide PVC sheet out of which 100 mm shall be flat and 15mm shall be bent in 90 degreee on the inner side to form top and bottom rail and 130 mm wide PVC sheet out of which 100 mm shall be flat and 15mm shall be bent in 90 degree on both side to form lock rail. An additional 5mm plus minus0.25 mm thick PVC strip of 20mm width is to be stuck on the interior side of the C channel using PVC solvent cement adhesive. Panel will be of aluminium wiremesh of 24 gauge to be fitted inside area of stiles & rails. The wire mesh in top, bottom & lock rail is sealed with 15mm x 15mm tube with steel screw of size 13/6 mm 10mm (5mm x 2nos) thick PVC strip of 25mm width is to be stuck & nails on both side of G.I. wire mesh interior at the top , bottom & lock rail. 10mm thcik (5mm x 2 nos ) thick , 20mm wide cross PVC sheet as gap insert for top rail & bottom rail door to be fixed to frame with 3 nos M.S powder coated butt hinges size 100mm x 25mmx 2mm and 32mm long steeel screws drilled suitable to pass through boththe walls of the M.S. tube other hardwares should be fixed with 19x6mm size steel screws etc complete as per direction of Engineer-in-Charge, manufacturer's & drawings.
Supply and fixing 30mm thick " RAJSHRI FACTORY MADE PVC CUP BOARD SHUTTER- WOOD FREE consisting fo frame made out of MS tubes of 19 guage thickness and size of 20mm x20mm for stiles as well as top bottom and lock rail. The inside panel shall consist of 20mm thick multi champer hollow PVC section of 1 mm wall thickness bonded using solvent cement adhesive with 5mm (plus or Minus) thick One side Prelam and other side plain colour PVC sheet of Desnity 600 kg/Cbm manufactured by an ISO - 9000 certified company on both side of the inside panel.the four edge of the panel to be sealed with lapping of 10mm thick & 20 mm wide PVC sheet batten(made by sticking 2 Nos rigid foam PVC sheets of 5mm plus or Minus) thickness PVC solvent cement adhesive 20mm thick (5mm x 4 Nos). Thick PVC sheet to be given for lock provision at lock height. complete as per direction of Engineer-in- Charge. manufacturer's specification and drawing. Frame incl size of 60x50 mm excluding handle 150mm size, Hinges stainless steel (Heavy) 100mm size, cupboard lock godrej or equivalent and screw and wall plug
S&F 18mm thick Plain PVC Ply fixed with screw/bonded with pvc adhesive solvent to PVC ply works all as directed. (Make Rajashri or equivalent)
S&F brass handle fabricated & fancy type polished of size 150mm
S&F door stopper stainless steel 150mm.
S&F heavy duty godrej lock code No. 7030.
S&F stainless steel butt hinges,medium weight,size 100mm with ISI mark.
S & F Stainless steel curtain rod of 25mm dia complete.
S & F complete Brass chromium plated brackets for curtain rod of 25mm dia fixed to wall as directed.
S&F framed work such as grills, gratings etc with ends of bar shouldered and/or Riketed or forged into pikes, framed guard bars etc confirming to Fe-290, Gde -E-165.
M&L for preparing new wood based surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer.
M&L for preparing new steel surfaces of any description, over 10 cm in width or girth, and applying two coats of synthetic enamel paint over a coat of red oxide primer.
Prepainted galvalume alu zinc coating GI based plain steel sheets 0.50mm thk of any color having tensile stregth of 550 Mpa as in chajjas fixed with screws with angle iron frame wk
M & L for mild steel frame work as in brackets of chajjas all as specified and directed by Engineer -in-charge.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engr-in-Charge.
M & L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) 75mm thick as in sub base all as specified.
M&L for 75mm thick cement concrete (1:3:6) type C1, using 20mm graded stone aggregate as in plinth protection, finishing cement concrete surfaces even and smooth without using extra cement, Joints of plinth protection shall be filled with bitumen mastic (1:3) complete all as specified and as directed.
Dismantling floor hearth or wall tiling including cement mortar bedding ( but not backing) removing servicable tiles to store and rubbish off the premises.
S&F Non skid ceramic coloured tiles mm, 7 to 8mm thick,(square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc,laid over 15 thick screed bed in cement mortar 1:6 and set and jointed in neat cement slurry and pointed in coloured cement.
S&F Non skid ceramic coloured tiles mm, 7 to 8mm thick,(square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in vertical surfaces fixed in 10 mm thick backing coat of cement mortar 1:3 and set and jointed in neat cement slurry and pointed in coloured cement.
S&F glazed ceramic Coloured tiles over vertical surface of wall,350x 250x 7mm/ 450x350x7mm thick (or nearest size), set and jointed in neat cement slurry and pointed in coloured cement to match including backing coat of 10mm thick in CM(1:4) complete all as specified and directed.
M&L for 20-25mm thick Granite (of any type) pre-polished in cooking platforms and like fixed with neat cement slury over 15mm thck cement mortar (1:4) including pointing using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
M&L for machine cut Kota stone ( greenish colour, pre polished) slab in one piece as in cill/ staircase terads flooring 18 to 20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of slab incl rubbing and polishing complete all as specified. over & incl 20mm thick screed bed in CM 1:4 complete all as specified.
All as per item No 57 above but as in Dado/Sirting/Riser (should be one piece). Over & incl 10mm thick rendering in CM 1:3
Rounding to edges of stone slabs one edge,such as in steps,cooking plateform,and other similar situations
Extra over item No.59 above, for providing two Nos grooves over stair case treads all as directed.(Note: Two nos grooves shall be measured as one length for payment)
S & F in repair, machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size conforming to IS 15658- 2006 of 60mm thickness, M-35 grade including 25mm thick sand cushion below paver blocks and filling the joints with sand complete all as specified and directed.
S&F in repairs vitreous china wash down white water closet pan (squatt pattern orrisa pattern complete size 580 x 440mm with integral footrest (excl flushing cistern & flush pipe) incl lime concrete etc complete
S&F in repair, vitreous china wash down water closet semi-pedestal pattern (anglo-Indian type), white (excluding fixing bolts, flushing cistern and flush pipe), complete all as specified and directed.
S&F PVC flushing cistern 10 ltr capacity white with inlet ball valve float flush pipe and handle including brackets and fixed in repair make : Slimline/Commander/Hindustan.
S&F in repairs flush pipe of polythene of low or high density. 32mm dia
S&F in repairs cast iron Nahani trap 75mm with grating including jointing to waste pipe fixed in cement concrete type B1(1:2:4)
S&F in repair grating 100 mm dia of PTMT (Min Wt 25 gms).
S&F PVC connection 15 mm dia and 450 mm long with both end socket fixed in repairs.
Dismantling of 110 mm dia cast iron/PVC pipes jointed in cement mortar and taking out if reqd.
Dismantling of 75 mm dia cast iron/PVC pipes jointed in cement mortar and taking out if reqd.
S&F PVC (SWR) single socketed rain water pipes/ soil waste pipes with rubber ring joints, 110mm dia, fixed to walls.
PVC (SWR) single socketed rain water pipes/ soil waste pipes with rubber ring joints, 110mm dia, fixed to walls. Fixing only
S&F PVC (SWR) single socketed rain water pipes/ soil waste pipes with rubber ring joints,75mm dia, fixed to walls.
PVC (SWR) single socketed rain water pipes/ soil waste pipes with rubber ring joints, 110mm dia, fixed to walls. Fixing only
S&F PVC (SWR) bends any radius, 110mm dia.
S&F PVC (SWR) bends any radius, 75mm dia.
S & F PVC (SWR) shoes 110 mm
S&F PVC (SWR) branch piece double (double Y) equal or unequal 110 mm bore
Al as per Item No 78 but 75 mm bore
S&F PVC (SWR) branch piece single (single Y) equal or unequal 110 mm bore
Al as per Item No 78 but 75 mm bore
S& F PVC (SWR) vent cowl 75 mm bore
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc
Brushing neat cement slurry with 3.0 kg of cement per sq meter
M&L for PCC (1:2:4) type B-0, 50mm thick (average thickness), using 12.5 mm graded stone aggregate using WPC @ 3% by wt of cement (Note:- Water proofing compound shall be measured and paid seperately).
M&L for PCC (1:2:4) type B-0, using 12.5 mm graded stone aggregate as in coving using WPC @ 3% by wt of cement
M&L for 10mm thick plastering in CM (1:3) using WPC @ 3% by wt of cement finished even & smooth w/o using extra cement.
Applying only a coat of bituminous primer @ 200 ml per Sqm on concrete surface
Supply only bituminous primer
Applying evenly two coats of industrial bitumen 85/25 @ 1.2 kg per sqm incl cleaning over primed surfaced (interval between 1st & 2nd coat shall be as directed by Enrg-in-Charge)
S&F for 32 mm GI pipe medium grade as in spout n.exc 1.00 RM each (in short lenth)
M&L for PCC (1:5:10) type E2 using 40mm graded stone aggregate as in filling in sunken floors
Taking down / chipping off cement plaster on brick / concrete surface etc on internal / external surface of wall / ceiling surface incl racking out joints hacking for key, scrubing down with water complete all as specified and as directed by Engr-in-Charge and deposited the debris outside the MD land complete all as specified and as directed by Engineer-In-Charge.
M&L for rendering 10mm thick using factory manufactured pre mix/ready mix plaster of 'Roofit Mix' of M/s Premier Floor to Roof Materials Pvt Ltd/'Easy plast' of M/s Walplast Products Pvt Ltd/'Readiplast' of M/s Ultratech Cement Ltd' / Soundp last PMC-1 of M/s Sound buildcare Pvt Ltd/or other approved equivalent make, having minimum composition of C:S : 1:6 using fully treated dry, well graded natural sand confirming to IS 383 suitable for plastering, having low rebound properties, low water demand for curing properties mechanical mixing with water in a metallic tray only to make good consistency as per the specification of the Manufacturer and applied over masonry and concrete surfaces and finishing with sagol finish not less than 1mm thick, including cleaning the surfaces, curing etc. complete all as specified & directed by Engineer-in-Charge
M&L for rendering 5 mm thick on ceiling using factory manufactured pre mix/ready mix plaster of 'Roofit Mix' of M/s Premier Floor to Roof Materials Pvt Ltd/'Easy plast' of M/s Walplast Products Pvt Ltd/'Readiplast' of M/s Ultratech Cement Ltd' / Soundp last PMC-1 of M/s Sound build care Pvt Ltd/or other approved equivalent make, having minimum composition of C:S : 1:3 using fully treated dry, well graded natural sand confirming to IS 383 suitable for plastering in ceiling, having low rebound properties, low water demand for curing properties mechanical mixing with water in a metallic tray only to make good consistency as per the specification of the Manufacturer and applied over concrete surfaces and finishing with sagol finish not less than 1mm thick, including cleaning the surfaces, curing etc. complete all as specified & directed by Engineer-in-Charge .
M & L for rendering 15 mm thick cement plaster in CM 1:4, two coats using factory manufactured pre mix/ready mix of 'Roofit Mix'of M/s Premier Floor to Roof Materials pvt.ltd/ 'Easy plast' of M/s Walplast Products pvt.ltd/ 'Readiplast' of M/s Ultratech Cement Ltd/'Soundplast PMC-1' of M/s Sound buildcare pvt.Ltd/ or other approved equivalent make, having minimum composition of C:S :: 1:4 using fully treated dry, well graded natural sand conforming to IS 383 suitable for external plastering, having low rebound properties, low water demand for curing properties, mechnIcal mixing with water in a metalic tray only to make good consistency as per the specification of the Manufacturer and applied over exterior masonry and concrete surfaces with base coat of 10 mm thick and finishing coat of 5 mm thick final rendering with water proofing compound @ 3% by weight of cement or as per manufacturer's instructions, including using richer mix for making corners if necessary, at all floors and level, including making grooves of existing size wherever required, including cleaning the surfaces, curing including provide of 150mm chicken wire mesh fixed with nails at the junction of RCC columns/walls/ beams/ lintels and brick masonry at external faces before plastering including scaffolding at any height and all safety materials required for execute work etc. complete all as per specifications & as directed by the EIC
Surface preparation of structural part by gentle chipping by manually to make the surface rough and thoroughly cleaned with air as per standard practice and directions of Engineer-in-charge (including removal of external plaster, wherever exists) COST inclusive of transportation, labour, conveying debris away from the site (50 m max.), tools and tackles, lead and lift etc.,complete all as specified and as directed by Engr-in-Charge.
M&L for Corrosion resistance bars of any Dia as Specified by Engnr-in-Charge, cut to lenth bent to shape required including cranking bending spirally for hooping for column hooking ends and binding with and including mild steel wire ( annealed ) complete all as specified and as directed by Engr-in-Charge.
Repairing the damaged concrete portion by using superfluid dual shrinkage compansated structural grade M40 Microconcrete including providing ,applying, finishing, curing, etc complete but excluding formwork etc complete all as specified and as directed by Engr-in-charge.
Providing & Fixing MS/TS dowel pins/staple/shear pins including drilling holes in concrete and providing labour and but excludes the materials for grouting the pins.etc complete all as specified and as directed by Engr-in-Charge.
Providing and applying the rust cleaner alkaline in nature to the existing/ additional rebars including wire-brushing manually or by mechanical tools, clean etc. complete. Measurment on the basis of area of concrete exposed etc complete all as specified and as directed by Engr-in-charge.
Providing and applying two coats of anticorrosive epoxy phenolic rebar protective system IPNet RB or equivalent of approved make and quality comprises of resin and hardner mixed in equal proportion by volume with minimum 9-10 hours between the coats, sprinkling dry sand when 2nd coat is tacky so as to provide rough finish and ensuring air curing of minimum 10 hours after the top coat before any subsequent treatment etc. including scaffolding etc. complete all as specified and as directed by Engr-in-Charge.
Providing and applying a priming cum bonding coat of two component Epoxide Resin confoms to ASTM-C-882-91 of approved make and quality to clean and sound concrete area by brush or any other established method by mixing Base and curing agent in 2:1 proportion by weight for joining old and new concrete as per technical specifications of manufacturer. Work shall be carried out as per the manufacturers specifications & certificate on this account shall be taken from consultant and as approved by Engineer-in-charge etc.complete.
Providing & Fixing the formwork of to pour the micro-concrete / concrete using steel sutters or 12mm marine ply to have the form finish including de- shuttering, etc. complete all as specified and as directed by Engr-in-Charge.
Drilling and fixing Teflon nozzles in RC members, including, Drilling Holes( Drilling 12 mm dia., 40 mm deep holes in structural members at the intervals of 600 mm in staggered manner or as directed by the engineer-in-charge in RC structural element)and Cleaning of holes (To Clean the holes by air blower prior to fixing nozzles)and Fixing of Nozzles(To Insert 12 mm dia. Teflon nozzles in cleaned holes. External end of nozzles to be machine to receive outlet of grouting gun and Fixing it inside the holes by applying thixotropic epoxy putty to ensure complete sealing and Curing the system for min. 12 hrs)and Cutting of Nozzles(To Cut the nozzles by chisel after completion of grouting without damaging structural elements) etc.complete.
Injecting low viscosity (3-5 cps) high molecular weight monomer by pressure and using mechanized injector gun with accessories, till nozzles refuses to accept the grout, Including, Mixing of materials( Mixing material components (part a & b) in required quantities as per manufacturer’s instruction by weigh batching) and Grouting ( Filling the grouting gun with monomer. Maintain desired pressure in the gun by air compressor; maintain the pressure at exit (4 to 5 Kg/ Cm2) by monitoring pressure gauge at exit. Grouting the material through prefixed nozzles in the structural elements till its refusal. Sealing the nozzle with epoxy putty after the refusal. Monitoring leakages through other nozzles while grouting and seal them as per the requirement. Repeat the process for all the nozzles. the operation to be within pot life of the material.)and Cleaning of gun and accessories ( the gun and accessories like valves, pipes and other fixtures to be cleaned with thinner after the operation to avoid jamming of the gun.) etc. complete.
Repairing the damaged concrete portion by average 20 mm thick polymer plaster @ a dose of 5% in ratio 1:3 (C:M) over the exposed non structural member surface including making the surface evenly smooth etc. as per manufacturer's instruction. ( Measurment on the basis offinished area).
Strengthening structural elements with non metallic composite fiber wrapping system comprise of uni-directional carbon fiber sheet (430 GSM) and compatible saturant Profiling: Applying compatible primer on prepared substrate, Filling the holes and uneven surface with thixotropic putty etc. complete Mechanized wetting of fiber sheet: Cutting the fabric to required size. Mixing of saturant and filling in tub area of the saturation machine. Placing the fiber on metallic rods and pass through the rollers of machine and saturant tub ensuring complete wetting (65% fiber volume fraction) of fibers. Remove the fiber on rod and place the new fiber sheet. Wrapping: Wrapping the fiber sheet to structural element at desired orientation using tamping roller to avoid any air voids etc. repeat the same procedure for multiple layer with the interval of 8 hrs. Second Coat: Applying second coat of saturant after min. 12 hrs, rectify air voids if any . (Mode of measurement: Per sq.mt of carbon fiber sheet consumed and not surface area of application).
Providing and fixing carbon fiber anchor including drilling hole in the base concrete fixing the anchor using epoxy 50X55 system spreading the anchor fibers in star pattern including appication of saturant etc. complete.
M&L for opening out cracks in wall surfaces in 'V' shape by mechanical grinder and removing the loose material. filling with crack filler of Dr. Fixit crack-X, shrinkfree or equivalentall as per manufacturer's instructions and finishing the surfaces to match with existing finish complete all as specified and as directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of Distemper oil emulsion over a coat of priming plastered and other surfaces with alkali resistant priming paint over thin layer of wall care putty on wall complete all as specified and directed
M&L for preparation of new plastered surfaces on ceiling and applying two coats of Distemper oil emulsion over a coat of priming plastered and other surfaces with alkali resistant priming paint over thin layer of wall care putty on ceiling complete all as specified and directed
M&L for preparation of new plastered surfaces and applying two coats of weather proof acrylic paint plain pattern over a coat of weather coat primer over thin layer of wall care putty complete all as specified and directed
M&L for complete removal of existing treatment of paint on wall and applying two coats of Distemper oil emulsion over a coat of priming plastered and other surfaces with alkali resistant priming paint over thin layer of wall care putty on wall complete all as specified and directed
M&L complete removal of existing treatment on wall and applying two coats of weather proof acrylic paint plain pattern over a coat of weather coat primer including preparation of surfaces complete all as specified and directed
M&L for preparation of old wooden surfaces of any description over 10cm width of girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old wooden surfaces of any description over 10cm width of girth and applying two coat of synthetic enamel paint over one coat of pink primer paint complete all as specified and directed.
M &L for preparation of old painted surfaces of steel of any description and in any position over 10 CM width or girth ,not otherwise described, and applying one coat of synthetic enamel paint complete including necessary scaffolding arrangement as required at site all as specified and directed
M & L for 150 mm dia RCC pipes of class NP-2 laid and jointed with collars etc complete all as pecified and as directed by Engnr-in-charge
M & L for cement concrete of Type B-2 (1:2:4) 40 mm Graded Stone Aggregate as in foundations Fillings and Mass concrete as the foundation of manholes complete all as specified and as directed by Engnr-in-Charge
M & L for providing Cement Concrete of Type B1 (1:2:4) 20 mm graded Aggregate in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed by Engngr-in-Charge
M&L for cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as in benching of manhole and for surface channels and drains including necessary form work complete all as specified and as directed by Engr-in-Charge.
M&L for concrete bed to 150 mm sewage pipes in cement concrete 1:3:6, type C2 (using 40mm graded stone aggregate) including packing under, and haunching against the sides of pipes after they are laid and testedcomplete all as specified and as directed Engineer-in-Charge.
M & L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi- tred/stopped ends etc complete all as specified and as directed by Engnr-in-Charge
M&L for providing precast reinforced cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) for manhole / drain covers etc. set in cement morter 1:6 finishing the exposed faces even and smooth without using extra cement including demolition of existing unserviceable RCC covers and removing debris out side MD land complete all as specified and as directed by Engr-in-Charge. Note :- Reinforcement shall be measured and paid separately).
M & L for cutting/Joining in to existing manholes for connecting new drains making good to pipe of internal dia 150/200 mm and rendering cutting out existing benching for and forming branch channel (1/2 Round or 3/4 Section) in Cement concrete 1:2:4 Type B-1 smooth finished and reforming benching as required complete all as specified and as directed by Engnr-in-Charge
Schedule 'A' Part II Taking down carefully old UNSV copper/aluminium point wiring any type complete and making good disturbed surface of wall , floors, ceilling etc all as specified.
M & L for point wiring with and including single core ,fire retardant,PVC insulated and unsheathed stranded copper conductor cable 1.5 Sqmm 1100 volts grade drawn through and including suitable size PVC casing caping and accessories with 2.8mm thick laminated top cover fixed on existing MS sunken box for housing of switch , socket , regulator etc complete with and including 1.5 Sqmm fire retardent PVC insulated and unsheathed stranded copper conductor cable as earth wire and connected to common earth dolly and making good to the disturbed surfaces of wall , floor, ceilling etc to match with existing surface complete all as directed for One Light/fan/bell point controlled by one switch
All as per Item No 128 but One 5 pin 5 Amps switch socket combination point on independent board
All as per Item No 128 but One 3 pin 5 Amps switch socket combination point in independent board below the switch board of the light point in the same vertical plane
All as per Item No 128 but One light point controlled by two 2 - way switches with cables 1.5 Sqmm
M & L for point wiring with and including single core ,fire retardant,PVC insulated and unsheathed stranded copper conductor cable 2.5 sq.mm copper wire for 15 Amps switch socket combination on independent board.
S&F Switch piano 5 Amps SP one way 230 volts flush type
S&F Switch piano 5 Amp two 2 -way 230 volt flush type
S&F ceiling rose, surface bakelite, three terminals AC 230 volts.
S&F lamp holder, insulated body,with back plate for batten fittings fixed on wall/ceiling complete all as specified.
S & F switch socket combination 5 Amps,5 pin multipurpose flush type, 230 volts.
S & F switch socket combination 15 Amps,6 pin multipurpose flush type, 230 volts.
S & F ceiling fan regulator AC,230 volts , 450 watts electronic step type.
S&F Electric call bell AC 230 V single pole type.
S&F Bell push AC, 230 volt, 5 Amp, flush type.
S& F sheet metal enclosure MCB DB SPN 6 way IP - 53 double door with 200 Amps rated bus bar 240 volt AC and connecting up complete all as specied
S&F MCB TPN 63 Amps rupting cap 25 KA
S&F MCB DB TPN 4way Double door
S& F MCB SPN 32 Amps ruptering cap 10KA
S& F MCB SP 32 Amps 240 volts,10 KA.
S&F box type fitting with blue coloured end caps for LED tube and all accessories including PVC squre box and prewired,connection with three core copper flexible cable 16/0.20 mm from ceiling rose to fitting complete all as specified. Make:- CG, Cat part No.DMLN1LT8-16 (or) equivalent BAJAJ, PHILIPS, HPL, HALONIX, Wipro
Supply, install, test and commissioning energy efficient LED tube rod for existing tube light fittings including necessary electrical wiring etc. complete all as per Make:- CROMPTON GRAVES LTD, Cat part No LTT8-20, or equivalent CG, PHILIPS, HALONIX, Wipro.
M & L for Submain wiring complete with and including 6 sq mm single core PVC insulated and unsheathed multistranded copper conductor cable single core 1100 Volts grade drawn through PVC conduit and including accessories and fixed on walls and 2.5 sqmm PVC multistranded copper conductor cable for earthing and connected to common earth dolly including taking down the existing wiring complete all as specified & directed.
S&F meter box in replacement with new meter box for housing meter and MCB's, made out of 3mm thick CRCA sheet duly painted with two coated synthatic enamel paint over a coat of redoxide primer of size 1.2mX1.2mX0.4m including fixed in angle iron stand 40x40x5mm grouted in floor including 45cm height from floor level and refixing of existing / new tamper proof meters and MCBs including providing wiring of suitable size of copper conductor cable and including necessary masonary work with wooden planks for mounting meters and MCBs complete taking down the old U/S meter box and making good the surface as required all as directed.
S&F Exhaust fan with louvers shutter 300 mm BEE 5 star rated complete all as specified and directed.
Dismantling the existing unserviceable KWH electric meter single phase any type / capacity and supply, fixing, testing single phase 2wire 240 Volts electronics digital display meter capacity of 10 to 60 A . Note: The removed old U/s electric meter should be deposited to AGE E/M store.
M&L for Earthing complete with Galvanised steel earth plate electrode 60cm x 60cm x 6.3mm thick, buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with the top edge of earth plate at a depth of not less than 1.5 metre below normal ground level, connected to GI wire 6 mm by means of bolts, nuts, check nuts and washer made out of Galvanised iron and protected by 15mm bore light grade GI Pipe and connected to control board/ panel/equipment complete all as shown in electrical plate No.3 including necessary earth work and excavation in any type of soil and PCC 1:2:4 type B-1 chamber with CI cover complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Bib tap, cast copper alloy with crutch or butterfly handle, screwed down, screwed for 15 mm bore heavy duty ISI marked including taking down.
S&F in repairs stop valve, cast copper alloy with crutch or butterfly handle, screwed down, high pressure with crutch or butterfly handle screwed for 15 mm bore both ends for iron pipe or for unions and fixed ISI marked including taking down
S&F in repair over head shower rose brass chromium plated 100 mm dia, heavy duty pattern with revolving joint suitable for jointing to 15 mm bore screwed GI pipe or union or socket swivel shower rose chromium plated 65 mm dia suitable for 15 mm pipe or union or socket, complete including taking down existing shower rose all as specified & directed.
S&F in repair GI Tubes 15mm bore,medium grade in lengths with screwed and socket joints,together with all galvanised steel fitting such as ,bends,tees,reducers,unions,cap plugs,nipples,clips etc fixed complete to walls and ceiling or laid in floors all as specified and directed. including taking down old U/S GI tubing.
All as per item No 157 above but for 20 mm bore
All as per item No 157 above but for 25 mm bore
S&F in repair PVC Rotational moulded polythene water storage tank (Cylindrical Vertical with closed top) of 1000 ltr capacity including outlet/inlet connection nipple, bends, sockets, complete with all fitting required at all as specified and directed by Engineer -in -charge (Make Sintex).
S & F in repair 25 mm dia gun metal, globe or gate valves, with iron wheel head screwed both ends for iron pipe fixed.
S&F in repair 25 mm dia ball brass valve high pressure with polythene float and fly nut complete screwed off iron pipe or brass ferrule & fixed.
M & L for plain cement concrete in Plinth of PVC service tank of any capacity and mass concrete type C1 1:3:6 using 20 mm graded stone aggregate including plaster on outside of the foundation. Note : (i) The rates quoted by the tenderer for item No 1 to 163 shall be inclusive of safety precautions & scaffolding arrangements for any height. (ii) If the rates quoted by the tenderers for same items is found different the lowest rates shall be consider for payment purpose.
SRINIVASA BUILDERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .