Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.0 CrAccepted-AOC DAKHINGAON KAHILIPARA P O P S DISPUR ASSAM | ₹9.0 Cr | L1 | Accepted-AOC Being L1 responsive bidder in financial evaluation |
| 2 | L2₹9.0 CrRejected-Finance | ₹9.0 Cr | L2 | Rejected-Finance Price quoted is higher than L1 vendor |
| 3 | L3₹9.0 CrRejected-Finance TRIBENI S COMMERCIAL COMPLEX 1ST FLOOR ULUBARI G S ROAD GUWAHATI 7 | GUWAHATI | KAMRUP | ASSAM | 781007 | ₹9.0 Cr | L3 | Rejected-Finance Price quoted is higher than L1 vendor |
| 4 | L4₹9.4 CrRejected-Finance 44 TARUN NAGAR GUWAHATI P O CHRISTIAN BASTI P S BHANGAGARH KAMRUP METRO PIN 781005 | KAMRUP METRO | ASSAM | 781005 | ₹9.4 Cr | L4 | Rejected-Finance Price quoted is higher than L1 vendor |
| 5 | L5₹9.5 CrRejected-Finance | ₹9.5 Cr | L5 | Rejected-Finance Price quoted is higher than L1 vendor |
Tender Value
₹10 Cr
Closing Date
20 Jan 2024, 2:00 pmClosed
Office of the State Project Director, AIWTDS
Office of the State Project Director, AIWTDS, Ulubari, Ghy 7
Construction of Crew Training Center Building at Pandu, Guwahati.
2023_TDEP_34894_1
IN-IWT-393764-CW-RFB
Open Tender
Civil Works - Building
Item Rate
270 days
Guwahati
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
Exempted
Office of the SPD, AIWTDS Ulubari, Ghy 7
28 Aug 2024
21 Dec 2023
20 Jan 2024
21 Dec 2023
20 Jan 2024
16 Jan 2024
21 Dec 2023 - 20 Jan 2024
29 Dec 2023
Amount
CIVIL WORKS
Providing, driving with hydraulic piling rigs with power units and installing driven cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of shoe and the length of pile to be embedded in the pile cap etc. all complete. (Length of pile for payment shall be measured from top of shoe to the bottom of pile cap) : 450 mm dia piles
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Note:- 1 . Initial and Routine Load test shall not be carried out by Dynamic method of testing. Note:-2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge. Single pile upto 50 tonne safe capacity Initial test. ( Test load 1.5 times the safe capacity)
Steel reinforcement for R.C.C. work ncluding straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. ( For Pile Work )
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil
Close timbering in case of shafts, wells, cesspits, manholes and the like including strutting, shoring and packing cavities (wherever required) etc. complete.(Measurements to be taken of the face area timbered). Depth exceeding 3 m but not exceeding 4.5 m.
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm) having CBR Value-25
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
Supplying and stacking at site. 63 mm to 45 mm size stone aggregate
Supplying and filling in plinth with local sand under floors, including watering, ramming, consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shttering - All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand(zone-III) : 8 graded stone aggregate 40 mm nominal size).
Supplying and stacking at site. 53 mm to 22.4 mm size stone aggregate.
Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density
Providing and laying factory made chamfered edge Cement Concrete paver blocks In foot path, park & lawns driveway or light & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer's specifications & direction of Engineer in-Charge. 80mm thick Cement concrete paver block of M-30 grade with approved colour, design & pattern.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shttering - All work up to plinth level 1:3:6 (1 Cement : 3 coarse sand(zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources).
Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4(1 Cement : 4 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 12.5 mm nominal size derived from natural sources).
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). All works upto plinth level
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). All works above plinth level upto floor V level
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
Centering & shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases of columns, etc. for mass concrete
Centering & shuttering including strutting, propping etc. and removal of form work for: Walls (any thickness) including attached pilasters, butteresses plinth and string courses etc.
Centering & shuttering including strutting, propping etc. and removal of form work for: Suspended floors, roofs, landings, balconies and access platform
Centering & shuttering including strutting, propping etc. and removal of form work for: Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering & shuttering including strutting, propping etc. and removal of form work for: Columns, Pillars, Piers, Abutments, Posts and Struts
Centering & shuttering including strutting, propping etc. and removal of form work for: Stairs, (excluding landings) except spiral-staircases
Dry brick pitching half brick thick including supply of bricks and preparing the surface complete : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in : Cement mortar 1:4 (1 cement : 4 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate
52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 , of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. The tiles must be cut with the zero chipping diamond cutter only.Laying of tiles will be done with the notch trowel,plier,wedge,clips of required thickness , leveling system and rubber mallet for placing the tiles gently and easily Size of Tile 800x800 mm ( Double Charge )
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete Size of Tile 600x600 mm
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
CEMENT PLASTERING 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement : 4 fine sand)
CEMENT PLASTERING 20 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement : 4 fine sand)
CEMENT PLASTERING 6 mm cement plaster of mix : 1:3 (1 cement: 3 fine sand)
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge.
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. : External work 32 mm dia. nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. : External work 50 mm dia. nominal bore
CHOWKATHS Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 5860 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. Frame size 65 x 125 mm
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. 30 mm thick
GRILL Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
UPVC WINDOWS AND OTHER WORKS Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Two track two panels sliding window made of (small series) frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm)
Providing and fixing factory made uPVC white colour sliding glazed door comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Two track two panels sliding door made of (big series) frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqm upto 5.00 sqm
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.20 mm M.S. laths with 1.20 mm thick top cover
PAINTING WORKS Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
PAINTING WORKS Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour Two coats
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture
DOOR AND WINDOW FITTINGS Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 100x85x5.5 mm (heavy type)
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 200x10 mm
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
Providing and fixing bright finished brass handles with screws etc. complete: 100 mm
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : Tower bolt ( 300 x 10 mm )
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : Tower bolt ( 250 x 10 mm )
Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : Door handle 125 mm
STEEL AND IRON WORKS Steel reinforcement for R.C.C. work ncluding straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
ANTI TERMITE TREATMENT Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration.
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- inCharge
WATER PROOFING Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
CLADDING WORK Providing and fixing of façade at all heights with extruded hollow Clay / Terracotta ventilated rainscreen tiles of height 259/ 309/ 409mm and lengthof 1190 mm of approved texture,design and pattern having Flexural Strength/ Modulus of Rupture of ? 14 N/m² and maximum water absorption of 10% tested as per ISO 10545-4:2004(E) and ISO 10545-3:1995 respectively in true level fixed to a supporting aluminium framework (Alloy 6063 T5/T6) consisting of vertical 'T' (for intermediates)/ 'L' (for ends/ termination)/ Tubular sections (at corners)of size 80x60x2mm/ 40x60x2mm/ 40x40x2mm respectively, spaced at maximum spacing of 1200mm c/c matching to the tile vertical grid, and horizontal aluminium 'C'-clamps of size 56x34x2 mm thickness of length 150mm at junction of tiles and of length 75mm at wall ends/ corners fixed on top of the vertical sections at spacing of 250/ 300/ 400mm c/c matching to the tile horizontal grid with two numbers of self-drilling / self-tapping SS screws of size 5.5x25 mm with EPDM washers.The vertical 'T'/'L/ Tubular' sections shall be fixed to the wall using HDG (hot-dip-galvanized) steel Lbrackets (galvanizing thickness of minimum 80 microns) of size 110x80x6 mm at intermediate vertical aluminium profiles and of size 220x110x12 mmat outer corners and stainless steel grade 304,M10 full threaded anchor fasteners with nylon sleeve 100mm long (for brick work) and M8 expansion anchor fasteners 75mm long for concrete surface, spacing of brackets to be based on a structural/ static calculation. The brackets shall be of length 175mm at junction of two vertical aluminium profiles and of length 100mm at intermediate points of vertical profiles and shall be fixed to the vertical aluminium T / L / Tubular profiles using two numbers self-drilling/ self-tapping SS screws of size 5.5x25 mm with EPDM washers.“EPDM gaskets to be fixed in between brackets and vertical profiles. The tiles shall be mounted on the ‘C’ clamps such that the tiles are supported at top and bottom at both ends. The tiles shall be mounted on the Cclamps with EPDM profiles in between such that the tiles are supported at top and bottom at both ends. The vertical joint open groove between two adjacent tiles shall be 10mm. The tiles and system shall be designed to resist wind load as per IS 875 (Part 3) according to different zones. The tiles shall be installed using the With 24mm thickness (+/- 10%) terracotta tiles of other than grey colors
Plumbing
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete
Providing and fixing toilet paper holder : C.P. brass
URINAL Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS :2556, C.I. trap with outlet grating and other couplings in C.P. brass,including painting of fittings and cutting and making good the wallsand floors wherever required : Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriatewidth with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade
WASH BASIN Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings
MIRROR Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 1500x450 mm
SHELF Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.
SOAP TRAY,SOAP DISH,LIQUID SOAP DISPENSER AND LIQUID SOAP CONTAINER Providing and fixing PTMT soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fitting arrangements. Weighing not less than 106 gms.
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
TOWEL RAIL,TOWEL RACK & TOWEL RING Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms.
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms
Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 38 mm dia of 83 mm length and 62 mm breadth weighing not less than 45 gms.
BOTTLE TRAP Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms
PVC PIPES,BENDS,JUNCTIONS,TEES ETC. Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, Single socketed pipes. 75 mm diameter
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, Single socketed pipes. 110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. Bend 87.5° 75 mm bend
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. Bend 87.5° 110 mm bend
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. Single tee without door 75x75x75 mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. Single tee without door 110x110x110 mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. Coupler 75mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. Coupler 110mm
GRATING Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet ( Sand cast iron S&S as per IS: 3989 )
PIPING Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall 25 mm nominal outer dia .Pipes.
PIPING Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall 40 mm nominal outer dia. Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia .Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc. 15 mm nominal outer dia .Pipes.
BIB COCK Providing and fixing brass bib cock of approved quality : 15 mm nominal bore ( Two way )
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
SHOWER Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 100 mm diameter
WATER STORAGE TANK Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. All types of soil 300 mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings& accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer- in-charge.
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Development of tube well in accordance with IS : 2800 (part I) and IS:11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge : External work 80 mm nominal inner dia. Pipes.
Providing and fixing gun metal non- return valve of approved quality (screwed end) : 80 mm nominal bore Vertical
Electrical
POINT WIRING Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed heavy duty PVC conduit with modular switch modular plate suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc.as required.
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed duty PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
Wiring for power plug points with 2 x 4 sq.mm. FRLS PVC insulated, Cu. Conductor, single core cable in surface/ recessed heavy duty PVC conduit along with 1 No. 4 sq.mm. FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light plug points / power plug points with 4 x 4 sq.mm. FRLS PVC insulated, Cu. Conductor, single core cable in surface/ recessed PVC conduit along with 2 Nos. 4 sq.mm. FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed Steel conduit as required 2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. earth wire.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed Steel conduit as required 2x2.5 sq mm + 1x2.5 sq mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed Steel conduit as required 4x2.5 sq mm + 2x2.5 sq mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed Steel conduit as required 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed Steel conduit as required 4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required.
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet (near equipment point) and 25 A modular SP MCB, “C” curve (at accessible point) including connections, painting etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. Bell Push
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
LIGHT FITTING & FANS Supply, installation, testing & commissioning of surface mounted LED downlighter fitting, fixture should have minimum efficacy at System level (Not Chip Level) ≥ 110lumens/watt, with Minimum system Lumens 1100, Life of fixture (Including Driver) : 50000 burning Hrs. @ L70B50 Lumen maintenance, CCT should be 5700K-6500K, CRI ≥ 80, PF ≥ 0.95, THD ≤ 5%, IP-20 rated, Die Cast Al heat sink with PMMA Diffuser. Luminaries manufacture shall provide LM79 report from NABL accredited lab & LM80 report issued by LED manufacturer.
Supply, installation, testing & commissioning of surface / wall mounted LED batten made of aluminium extruded / PVC housing with high efficiency polycarbonate/Acrylic diffuser, LED Used shall be SMD type and fixture should have minimum efficacy at System level >=110lumens/watt with Minimum system Lumens 2000, Life of fixture: 25000 burning Hrs. @ L70B50 Lumen maintenance, CCT of 5700K-6500K, CRI ≥80, PF ≥ 0.95 & THD≤10%, Minimum Internal Surge Protection 2.5KV. Luminaire manufacture shall provide LM 79 report from NABL accredited lab & LM80 report issued by LED manufacturer.
Supply, installation, testing & commissioning of LED Bulkhead with a nominal system lumen output of 600 lumens and a minimum system efficacy of 60 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a color temperature of 6500K and CRI > 70. The luminaire shall meet IP66 rating and IK 09 rating with THD < 20% and PF > 0.9. The luminaire housing should made of High pressure die cast Aluminium with polycarbonate front diffuser. The total power consumption should not exceed 10W (including driver). Including 3 core 1.5 sq.mm FRLS PVC insulated and PVC sheathed copper conductor cable and earthing etc. Up to suitable point complete as required.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Supplying and fixing of 300 mm sweep metallic body Fresh air fan with all accessories suitable for operation single phase 230 volt 50 cycle per second per sec. AC supply etc. as required. in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning earthing etc. as required.
DISTRIBUTION PANELS Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way (4 + 36), Double door
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. For 14 way, Double door SPN MCBDB
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface / recess, complete with testing and commissioning etc.as required. For 8 way, Double door TPN MCBDB
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing following rating, double pole, 240 volts, MCB complete with connections, testing and commissioning etc. as required. 25 Amp DP MCB
Supplying and fixing following rating, double pole, 240 volts, MCB complete with connections, testing and commissioning etc. as required. 63 Amp DP MCB
Supplying and fixing of following rating, 240/415 volts, "C" curve, four pole miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amp FP MCB
Supplying and fixing of following rating double pole (Single phase and neutral) 240 volts, residual current circuit breaker (RCCB), having a current sensivity current 100 miliampere in the existing MCB DB complete with connections, testing & commissioning etc. as required. 25 Amps
Supplying and fixing of following rating double pole (Single phase and neutral) 240 volts, residual current circuit breaker (RCCB), having a current sensivity current 100 miliampere in the existing MCB DB complete with connections, testing & commissioning etc. as required. 63 Amp
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
EARTHING AND LIGHTNING PROTECTION Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required.
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
CABLES, CABLE TRAY'S, RACE WAYS (LT Cables and Terminations) Supplying following 1.1kV grade, heavy duty XLPE insulated PVC Sheathed Aluminum Conductor FRLS type armoured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel armouring (round or flat as mentioned) and with all components as mentioned in BOQ, specifications and schedule, complete etc. as required. 3.5 core, 50 sq.mm.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 35 sq. mm and upto 95 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 3½ X 50 sq. mm (35mm)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 120 mm dia (OD-120 mm & ID-103 mm nominal)
(Cable Trays) Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 100 mm width x 50 mm depth x 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 100 mm width x 50 mm depth x 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Tee” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 100 mm width x 50 mm depth x 1.6 mm thickness
INSPECTION CHAMBER: Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design : Inside dimensions 455x610 mm and 45 cm deep for single pipe line :B With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for depth beyond 45 cm of brick masonry chamber For 455x610 mm size With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
UPS / INVERTER 5 KVA UPS WITH 30 MINUTES BATTERY BACKUP Supply, installation, testing & commissioing of 5 KVA UPS at 0.99 input power factor, UPS efficiency 0.93%, hormonic THDi less than 3%, Remote alarm indication panel, SNMP card as per specification given in the document with following broad features. THD(i) shall be less than 3% in the entire loading range. UPS shall carry design output at 40 deg. Shall have soft start and hold of for incoming supply.Invertor capability to supply 150% load for 1 min. Single Phase Input and Single Phase Output. (Input - 220V - 240V, Three Phase, 4 wire. / Output - 230 Volt, Single Phase, 3 Wire.) Shall not allow deep discharge of the battery and shall not go to 10.5 volts in case of 12 volt cells. Battery shall be external type with rack and suitable for 30 minute backup on 100% load. UPS shall be compatible for minimum 3 nos. unit in parallel operation. (Synchronize). Parallel operation kit shall be supplied with UPS. Suitable size cable from UPS to battery bank. UPS described as above
TV SYSTEM Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. TV antenna socket outlet
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supply, erection, testing and commissioning of following sizes of splitter of aluminium die cast body in suitable size of G.I. Box. 6 way
Supplying and fixing of following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1or 2 module (75mmx 75mm)
Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 25 mm
LAN & TELEPHONE NETWORKING SYSTEM Supply, Installation, Testing & Commissioning of Category 6 RJ45 Unshielded Modular Jack,
Supply, Installation, Testing & Commissioning of Cat6 Patch Cord UTP Unshielded LSZH 24AWG Patch Cord, Diameter < 6.2mm, 1 Meter, Operating Temperature -20 to +60 Deg C. Patch cord 1 Mtr for rack side switch to jack panel connectivity.
Supply, Installation, Testing & Commissioning of Cat6 Patch Cord UTP Unshielded LSZH 24AWG Patch Cord, Diameter < 6.2mm, 3 Meter, Operating Temperature -20 to +60 Deg C. Patch cord 2 Mtr for rack side switch to end user connectivity.
Supply, Installation, Testing & Commissioning of loaded 24 port CAT 6 UTP, Transparent shutter jack panel, 1U height, UL-94V-0, clear label marks and earthing plug for CAT6A cable termination at rack end.
Supply, Installation, Testing & Commissioning of 9U wall mount rack with fans , 2 cable managers , satationary shelf , 2 Nos. of hardware pkts.
Supply, Installation, Testing & Commissioning of of 24 Port pOE Access Switches with switching capaticy of 128 Gbps, forwarding performance 95 Mpps, having 24 x 10/100/1000BASE-T PoE-plus(RJ45) with 2 x 10G SFP+ uplink ports. Should support for Stacking/VC with stacking cable with stacking bandwidth of maximum 40 Gbps as and when required. Should support min 2GB internal DRAM, 2GB internal Flash memory, 16K MAC address. Should have Static Routing , Neighbor discovery, system logging, Telnet, SSH, SNMP, Network Time Protocol (NTP), Domain Name System (DNS) and IPv6 features from day 1 and should support OSPF, VRRP, OSPFv3 and PIM.
Supply, Installation, Testing & Commissioning of 6 Port 1U x 19” LIU Loaded with Singlemode OS2 LC Adapters & LSZH Pigtails along with Splice Trays, Min. 4 No of Circular Cable Entry with Rubber Groummet/Glands to close any open entry, Cable Holders for Cable Entry Inside Panel, Heat Shrink Tubes for Splices, Tube for open fibers, Ties, Panel shall be Powder Coated with Min. 1.2mm Metal Sheath, 30 Years Channel Warranty. Factory Loaded LC Type LSZH Pigtails should meet IEC 61034-1 ,IEC-60332-1, IEC-60754-1, Insertion loss <= 0.35 dB, Return Loss >= 50, Attenuation: 1310/1550 : 0.3/0.2 dB/KM, Repeatability: <= 0.2DB 1000 Times Mating Cycles, RoHS Complied, Meets ANSI/TIA 568.3-D.
Supplying and fixing following modular type switch/ socket on the existing switch box/ cover including connections etc. as required. Telephone Socket Outlet
Supply, Installation, Testing & Commissioning of analog handset complete as required.
Supply, installation, testing and commissioning of following krone type tag blocks enclosed in MS enclosure of suitable size with lockable cover. 50 pair tag block
Supply, installation, testing and commissioning of following krone type tag blocks enclosed in MS enclosure of suitable size with lockable cover. 20 pair tag block
Supply, installation, testing and commissioning of following krone type tag blocks enclosed in MS enclosure of suitable size with lockable cover. 10 pair tag block
Supply, installation, testing and commissioning of following sizes telephone cable. 50 pair telephone cable
Supply, installation, testing and commissioning of following sizes telephone cable. 20 pair telephone cable
Supply, installation, testing and commissioning of following sizes telephone cable. 10 pair telephone cable
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephonecable in the existing surface/ recessed steel/ PVC conduit as required. 1 Pair
Supplying and fixing of following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1or 2 module (75mmx 75mm)
Supplying and fixing of following sizes of medium duty PVC conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 25 mm
IP BASED CCTV SYSTEM Supply, installation, testing and commissioning of 5 MP Dome camera ,ONVIF profile S,G & T. UL , CE , FCC Certified ,1/2.7” Progressive Scan CMOS , 3.6 mm fixed lens , Quad stream Each stram support H.265 compression simultaneously ,min illumination : Color 0.05lux @ F1.2(AGC ON) ; B/W 0 lux @ IR ON , Shutter speed : 1 / 5s ~ 1 / 100,000 s , WDR , Compression : H.265/H.265+/H.264/H.264+ .SD card support upto 256GB , frame rate : Main stream should support 25 fps@5MP ,Edge analytics : Customer Flow staistics, Cross Count,Heat Map, Human & Vehicle Detection, Pedestrian Intrusion Detection & Line cross Detection. Queue length detection Regional population statistics, SOD-Stationaary Object Detection , In built IR LED , IR Distance upto 30 meters , IP 66 ,POE.
Supply, installation, testing and commissioning of 5 MP Bullet camera , ONVIF profile S ,G & T . UL , CE , FCC Certified ,1/2.7” Progressive Scan CMOS , 3.6 mm fixed lens , Quad stream support ,min illumination : Color 0.05lux @ F1.2(AGC ON) ; B/W 0 lux @ IR ON , Shutter speed : Shutter speed : 1 / 5s ~ 1 / 100,000 s ,WDR , Compression : H.265/H.265+/H.264/H.264+ .SD card support up to 256GB , frame rate : Main stream should support 25 fps@5MP , Edge analytics : Customer Flow staistics,Cross Count Heat Map, Human & Vehicle Detection, Pedestrian Intrusion Detection & Line cross Detection. Queue length detection, Regional population statistics, SOD-Stationaary Object Detection. , In built IR LED , IR Distance upto 30 meters , IP 66 , POE.
Supply, installation, testing and commissioning of 16 channel NVR , ONVIF compliant , recording bandwidth 640 Mbps , output interface 1 HDMI (up to 4K), 1 VGA , Alarm in/out :16ch in / 4ch out , 1 X RJ45 ethernet , iOS smartphone support , 8 HDD support , each HDD slot support upto 8 TB HDD , 1x3.0 USB for backup /upgrade , 2x 2.0 USB for mouse .Edge analytics of poposed cameras must be integrated with NVR . Artificial Intelligence Support having face recognition with compatible deep learning supported cameras, AI-Face registered quantity upto 10,000 ,A.I maximum captured quantity 200,000. UL,CE,FCC certified.
Supply, Installation, Testing & Commissioning of 8TB Surviellance Hard Disk.
Supply, Installation, Testing and Commissiong of Workstation PC: Intel(R) Core(TM) 8th gen i7-3770 Processor (8M Cache, up to 3.90 GHz); RAM: 16GB (2x8GB) Non-ECC DDR3 1600MHz ; Keyboard: 12 function keys; Chassis: Tower/Workstation; DVD: 8X Slimline DVD+/-RW, Data Only; Dual Graphics Card; Network interface card: Integrated Intel(R) 82579LM Gigabit1 Ethernet LAN 10/100/1000; Hard disk: 250GB, 7200 RPM 3.5" SATA 6Gb/s Hard Drive; Operating system: Windows 7 Professional 64 Bit or latest.
Supply, Installation, Testing and Commissioning of Full HD 55" LED Professional Display Panel.
Supply, Installation, Testing & Commissioning of Cat6 Patch Cord UTP Unshielded LSZH 24AWG Patch Cord, Diameter < 6.2mm, 1 Meter, Operating Temperature -20 to +60 Deg C. Patch cord 1 Mtr for rack side switch to jack panel connectivity.
Supply, Installation, Testing & Commissioning of Cat6 Patch Cord UTP Unshielded LSZH 24AWG Patch Cord, Diameter < 6.2mm, 3 Meter, Operating Temperature -20 to +60 Deg C. Patch cord 2 Mtr for rack side switch to end user connectivity.
Supply, Installation, Testing & Commissioning of Category 6 RJ45 Unshielded Modular Jack,
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. 1 run of cable
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm)
Supplying and fixing of following sizes of medium duty PVC conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 25 mm
8 PASSENGER LIFT ( G+4 ) ( PAR-3.1.1)
Acoustic & AV System
Cable and accessories: Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required 80 mm dia
Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
Erection of disc/ pin insulator for 11 KV over head lines as required.
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A, 16 KA,TPMCCB
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 250 A,50KA,FPMCCB
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 400 A,50KA,FPMCCB
CAST RESIN TYPE DRY TRANSFORMER Supply, Erection, Testing & Commissioning of 250kVA, 11kV/415V, 350MVA, Dyn11, AN type indoor mounting copper wound, "Cast Resin Type Dry Transformer" with Class- H insulation,off load tap link, winding temperature indicator, bidirectional rollers, marshalling box, cable box with HT disconnecting chamber and LT disconnecting chamber on LT side and all other accessories as required. The off load tap link with (+)5% and (-)5% tappings in step of 2.5%. The installation shall confirm IS : 10028.1981(Part II) & amended upto date. The rate shall be inclusive of necessary civil works, mounting channels, earthing etc. complete in all respect.
HT CABLE Supply & Laying of "11kV, 3C HT XLPE(E) Al. Armoured Cable". The rate shall be inclusive of necessary supporting & clamping arrangement for laying of cables within tray/pipe/trench. The installation shall confirm IS : 1255.1983 & amended upto date. 11KV, 3&1/2C X 300SQMM XLPE ALUMINIUM CABLE.
Supply & Laying of "11kV, 3C HT XLPE(E) Al. Armoured Cable". The rate shall be inclusive of necessary supporting & clamping arrangement for laying of cables within tray/pipe/trench. The installation shall confirm IS : 1255.1983 & amended upto date. Supplying of following size of PVC/XLPE insulated and PVCSheathed 1.1 KV gd Mtrs. Solid Aluminium conductor up to 10 sqmm, balance stranded conductor, XLPE Insulated, cores laid up, PVC tape innersheathed, Armour (Aluminium wire for single core up to 70 sqmm, balance Aluminium Strip, Galvanised wire for cables upto 2X10 sqmm, 3X10 sqmm, 4X6 sqmm & balance all galvanised steel strip),. extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908 (Part 1) 1988 armoured U.G cable as specified and directed by the department. (Havells/RR Kabels /Polycab or equivelent make as approved by this Dept.). 185.00 Sqmm 3.5 Core Armoured UG Cable.
Supply, Erection, testing and commissioning of G.I Steel tubular pole for extension of H.T line as per direction & specified by the Deptt. (Nezone/ consoul make
STATUTORY CHARGES TO BE PAID TO APDCL Liasoning & Obtaining preliminary & final NOC from the "Directorate Of Electricity".
Payment of Load Security of 10 KW (As per APDCL)
Supplying including installation, commissioning of DTR fencing as per APDCL
Supplying Meter, including installation, commissioning of 11 KV CT/PT, 11 KV Energy Energy Meter Cabinet, Supervision Charge to be to APDCL etc. APDCL EStimate
DG Design, Manufacture, Supply, erection, testing and commissioning of 250kVA, 415V, 3 Phase, 4 Wire, 50 Hz at 0.8 p.f. prime continuous (actual) rating radiator cooled diesel generating set in acoustic enclosure with radiator, Water cooled engine, PMG, base frame, Alternator, Static Excitation System, Lube Oil System, Electronic Governor, 24V Batteries & Battery Charger, Instrumentation, day oil fuel tank, Residential Silencer with Bellows, Alarms, microprocessor based Engine Control Panel, AVR Panel ,equivalent for AMF facility, termination adopter box suitable for XLPE insulated aluminium cables, drip trays space for mounting all associated equipments/ works as per specification including providing common base plate, anti vibration isolators, foundation bolts etc.The civil works for foundation for D.G.Set shall be included in the rate. But other accessories like grouting screws, anti-vibration pads etc. shall be included in the rate. Alternator shall have class H insulation and rated for 100 KW output at 50°C. Emergency stop push button for individual DG set shall be located at the exit door. Engine shall not be derated upto 50 deg.C ambient. Note: Piping between day oil tank & DG set shall be included.
Construction of R.C.C. Slabwith RCC Post for holding of Transformer
SECTION I: FIRE PUMPS AND ACCESSORIES FIRE PUMPS Providing and fixing horizontal single stage pumping set with CI body, bronze impeller, stainless steel sheet and connected by a flexible coupling to a totally enclosed fan cooled indication motor mounted on common structural base plate with all pump accessories complete as per specificaions including rubber neoprendined vibration eliminators mounting pad and expansion bellow in suction discharge connection between pump and piping, motor to be suitable for 415V 3 phase 50 Hz AC supply. MAIN PUMP FOR HYDRANT & SPRINKLER Type of pump - Centrifugal End Suction/ Vertical on line Capacity - 2280 LPM Head -56 MWC HP - ( Power requirements as per Clause 7.4.1.5 of TAC's Fire Protection Manual) Motor RPM - 2850
JOCKEY PUMP FOR HYDRANT & SPRINKLER Type of Pump - Centrifugal End suction/Multistage Capacity - 180 LPM Head-70 MWC HP- 7.5 Kwt/ 10 H.P. Motor RPM- 2900
FIRE PUMP (DIESEL ENGINE DRIVEN) Providing and fixing standby single horizontal centrifugal pump set of CI body bronze impeller, stainless steel shaft. The pump shall be connected by a flexible coupling to a suitable capacity of diesel engine with automatic starting alongwith battery charger, panel, including MS base plate and mountings. The diesel driven pump shall be complete with diesel tank with level indicator, exhaust piping insulated etc. complete as described in technical specifications. Type of Pump - Centrifugal End suction Capacity - 2280 LPM Engine BHP- (As per Clause No. 74.5.2.3 TAC's of Fire Protection Manual ) Head -56 MWC RPM - 1500
Providing and fixing pressure switches for every individual pump to operate at drop of pressure set for.
Providing and fixing double flanged vertical air vessel fabricated from 8mm MS plate with dished ends 250mm dia and 2m high common for fire and jockey pumps complete with Air release valve and GM gate valves in drain and all connecting nozzles etc.
ELECTRICAL WORK Supplying, laying, termination & testing of undernoted sizes of copper conductor FRLS insulated both inner and outer sheath, PVC sheathed and sleeved 1.1 KV grade power distribution cables conforming to relevant IS code and laying through and clamping the wall/racks/cable trays including dressing and clamping the cable with M.S. zinc passivated clamps etc. as required. 3C x 120 sq.mm ( Alluminium)
ELECTRICAL WORK Supplying, laying, termination & testing of undernoted sizes of copper conductor FRLS insulated both inner and outer sheath, PVC sheathed and sleeved 1.1 KV grade power distribution cables conforming to relevant IS code and laying through and clamping the wall/racks/cable trays including dressing and clamping the cable with M.S. zinc passivated clamps etc. as required. 3C x 2.5 sq.mm ( Copper)
ELECTRICAL WORK Supplying, laying, termination & testing of undernoted sizes of copper conductor FRLS insulated both inner and outer sheath, PVC sheathed and sleeved 1.1 KV grade power distribution cables conforming to relevant IS code and laying through and clamping the wall/racks/cable trays including dressing and clamping the cable with M.S. zinc passivated clamps etc. as required. 3C x 10 sq.mm ( Copper )
Structural supports as required for cable trays complete with installation with anchor fastner/grouting as applicable. Painting with red oxide and 2 coats of enamel paint of colour as specified by Owner/Consultant.
Providing and fixing of Mild steel black pipes (IS: 1239 Part-I heavy class including cutting, welding/threaded joint and all fittings viz. Flanges, bends, tees, elbows, reducers, clamps, hangers, structural supports, nuts and bolts, gasket etc. Also cutting holes/ chasing in brick or RCC walls/slabs and making good complete, painting with one coat of primer (red oxide) and two or more coat of synthetic enamel paint to give and even shade of approved shade (for above ground piping). 25mm
Providing and fixing of Mild steel black pipes (IS: 1239 Part-I heavy class including cutting, welding/threaded joint and all fittings viz. Flanges, bends, tees, elbows, reducers, clamps, hangers, structural supports, nuts and bolts, gasket etc. Also cutting holes/ chasing in brick or RCC walls/slabs and making good complete, painting with one coat of primer (red oxide) and two or more coat of synthetic enamel paint to give and even shade of approved shade (for above ground piping). 50mm
Providing and fixing of Mild steel black pipes (IS: 1239 Part-I heavy class including cutting, welding/threaded joint and all fittings viz. Flanges, bends, tees, elbows, reducers, clamps, hangers, structural supports, nuts and bolts, gasket etc. Also cutting holes/ chasing in brick or RCC walls/slabs and making good complete, painting with one coat of primer (red oxide) and two or more coat of synthetic enamel paint to give and even shade of approved shade (for above ground piping). 80mm
Providing and fixing of Mild steel black pipes (IS: 1239 Part-I heavy class including cutting, welding/threaded joint and all fittings viz. Flanges, bends, tees, elbows, reducers, clamps, hangers, structural supports, nuts and bolts, gasket etc. Also cutting holes/ chasing in brick or RCC walls/slabs and making good complete, painting with one coat of primer (red oxide) and two or more coat of synthetic enamel paint to give and even shade of approved shade (for above ground piping). 100mm
Providing and fixing of Mild steel black pipes (IS: 1239 Part-I heavy class including cutting, welding/threaded joint and all fittings viz. Flanges, bends, tees, elbows, reducers, clamps, hangers, structural supports, nuts and bolts, gasket etc. Also cutting holes/ chasing in brick or RCC walls/slabs and making good complete, painting with one coat of primer (red oxide) and two or more coat of synthetic enamel paint to give and even shade of approved shade (for above ground piping). 150mm
Providing and fixing of Mild steel black pipes (IS: 1239 Part-I heavy class including cutting, welding/threaded joint and all fittings viz. Flanges, bends, tees, elbows, reducers, clamps, hangers, structural supports, nuts and bolts, gasket etc. Also cutting holes/ chasing in brick or RCC walls/slabs and making good complete, painting with one coat of primer (red oxide) and two or more coat of synthetic enamel paint to give and even shade of approved shade (for above ground piping). 200mm (6mm thick)
Providing and fixing STRAINER Box type with M.S. flanged connection. 80mm
Providing and fixing STRAINER Box type with M.S. flanged connection. 100mm
Providing and fixing cast iron Dual plate spring loaded type Non-Return Valve (as per technical specification) including nuts, bolts, 1.5mm thick CAF gasket sheets complete in all respects (PN 1.6) 80mm
Providing and fixing cast iron Dual plate spring loaded type Non-Return Valve (as per technical specification) including nuts, bolts, 1.5mm thick CAF gasket sheets complete in all respects (PN 1.6) 100mm
Providing and fixing cast iron Dual plate spring loaded type Non-Return Valve (as per technical specification) including nuts, bolts, 1.5mm thick CAF gasket sheets complete in all respects (PN 1.6) 150mm
Providing and fixing cast iron Dual plate spring loaded type Non-Return Valve (as per technical specification) including nuts, bolts, 1.5mm thick CAF gasket sheets complete in all respects (PN 1.6) 200mm
Providing and fixing pressure gauge (0-10 Kg/Cm. Sq.) complete with isolation valve.
Providing and fixing cast iron Butterfly valve as per IS:13095 (PN: 1.6) including nuts, bolts, minimum 1.5mm thick CAF gasket sheets, complete in all respects. 80mm
Providing and fixing cast iron Butterfly valve as per IS:13095 (PN: 1.6) including nuts, bolts, minimum 1.5mm thick CAF gasket sheets, complete in all respects. 100mm
Providing and fixing cast iron Butterfly valve as per IS:13095 (PN: 1.6) including nuts, bolts, minimum 1.5mm thick CAF gasket sheets, complete in all respects. 150mm
Providing and fixing G.M. stop valve ISI marked screws type tested as per IS: 778 of following size: 25mm
Providing and fixing G.M. stop valve ISI marked screws type tested as per IS: 778 of following size: 15 mm
Providing and fixing gunmetal four way collecting head with 63mm dia instantaneous type inlet with built in check valve for fire brigade connection to underground tanks as per IS: 904.
Providing and fixing standard draw out connection with 63mm dia instantaneous type coupling and Foot valve with all accessories as approved by fire authorities for installation at under ground tank.
SECTION-II: FIRE HYDRANT SYSTEM Providing and fixing black steel pipes to IS: 1239/3589 heavy class including all fittings like anchor fastners, couplings, bends, elbows, tees, flanges etc. welding as required painting with one coat of red-odixe primer and two or more coats of synthetic enamel paints to give an even shade, cutting holes and chases in brick or RCC walls and making good complete. (For above ground piping). 80mm
SECTION-II: FIRE HYDRANT SYSTEM Providing and fixing black steel pipes to IS: 1239/3589 heavy class including all fittings like anchor fastners, couplings, bends, elbows, tees, flanges etc. welding as required painting with one coat of red-odixe primer and two or more coats of synthetic enamel paints to give an even shade, cutting holes and chases in brick or RCC walls and making good complete. (For above ground piping). 100mm
SECTION-II: FIRE HYDRANT SYSTEM Providing and fixing black steel pipes to IS: 1239/3589 heavy class including all fittings like anchor fastners, couplings, bends, elbows, tees, flanges etc. welding as required painting with one coat of red-odixe primer and two or more coats of synthetic enamel paints to give an even shade, cutting holes and chases in brick or RCC walls and making good complete. (For above ground piping). 150mm
Providing and fixing black steel pipe to IS: 1239 (Heavy Class) including all fittings like anchor fastners, couplings, bends, elbows, tees, flanges, gasket etc. welding as required painting with coat of solvent based primer and wrapping with 5 layered corrosion protection tape 4.0mm or (4mm thick) conforming to IS: 10221 completed. (For under ground piping). 150mm
Providing and fixing SS ISI marked obligue pattern fire hydrant valve with 80mm dia flanged inlet and 63mm dia instantaneous type female type lug and all accessories as per IS: 290-1983 'Type 'A' with hydrant matching flanges, gasket, nuts and bolts etc. complete in all respects. a) Single headed
Providing and fixing 63mm dia 15 Mtr. long flexible hose including SS male and female instantaneous type coupling (IS: 903), machine wound with copper wire complete in all respects with ISI certification. a) RRL Hose pipe
Providing and fixing of SS 63mm dia short branch pipe with Jet pattern nozzle, ISI marked (IS: 903).
Providing and fixing fire hose cabinet of size 750x600x250 fabricated from 16 gauge MS sheet of fully welded construction with hinged double front door with locking arrangements and partially glazed with 5mm thick glass stove enamelled fire red finish with fire hose written on front suitable to house 2x15 hose with couplings, one branch pipe (for external yard hydrants). Design to be got approved by Engineer-in-Charge before fabrication.
Providing and fixing first aid fire hose reel drum wall mounting swinging type fitted with 30 mtrs. 20mm dia high pressure rubber hose to IS: 5132 with 5mm outlet gunmetal nozzle with shut off valve (IS: 884).
Providing and fixing G.M. stop valves ISI marked screwed type tested to pressure as per IS: 778 of following sizes. 25mm
Providing and fixing cast iron slim seal wafer type Non-Return Valve (as per IS: 5312) including nuts, bolts, 1.5mm thick CAF gasket sheets complete in all respects. 100mm
Providing and fixing cast iron slim seal wafer type Non-Return Valve (as per IS: 5312) including nuts, bolts, 1.5mm thick CAF gasket sheets complete in all respects. 150mm
Providing and fixing double flanged cast iron Butterfly Valves complete with bolts, nuts 1.5mm CAF gasket complete conforming to IS: 13095. 80mm
Providing and fixing double flanged cast iron Butterfly Valves complete with bolts, nuts 1.5mm CAF gasket complete conforming to IS: 13095. 150mm
Providing and fixing gunmetal 2 way fire brigade connection head with 63mm dia instantaneous type inlet with built in check valves for fire brigade connection to fire risers (IS: 904-1965). A wall mounted box of MS construction with glass door to house the above mentioned components.
Providing and fixing portable fire extinguisher, dry powder type (gas cartridge) with cylinder initially fully charged with dry powder (ABC type) of 6 Kg. Complete with standard discharge valve with tube, CI bracket for wall mounting etc. conforming to IS: 2171.(Safe Pro Make)
Providing and fixing portable fire extinguisher carbon dioxide type with cylinder initially fully charged with CO2 gas of 4.5 Kg. Capacity, complete with discharge valve, dishcarge tube, horn, CI bracket for wall mounting etc. conforming to IS: 2878. (Safe Pro Make)
Providing and fixing portable fire extinguisher mechanical foam type with cylinder initially fully charged with foam compound of 9 litres capacity, complete with standard discharge valve with tube CI bracket for wall mounting etc. conforming to IS: 10204. (Safe Pro Make)
SECTION-III: SPRINKLER SYSTEM Providing, fixing, testing and commissioning of mild steel black pipes (IS: 1239 Part-I) heavy class including cutting welding etc. and providing all fittings viz., flanges, bends, tees, elbows, reducers, clamps, hangers etc. wall/slabs and making good complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved shade. 25 mm dia.
SECTION-III: SPRINKLER SYSTEM Providing, fixing, testing and commissioning of mild steel black pipes (IS: 1239 Part-I) heavy class including cutting welding etc. and providing all fittings viz., flanges, bends, tees, elbows, reducers, clamps, hangers etc. wall/slabs and making good complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved shade. 32 mm dia.
SECTION-III: SPRINKLER SYSTEM Providing, fixing, testing and commissioning of mild steel black pipes (IS: 1239 Part-I) heavy class including cutting welding etc. and providing all fittings viz., flanges, bends, tees, elbows, reducers, clamps, hangers etc. wall/slabs and making good complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved shade. 50 mm dia.
SECTION-III: SPRINKLER SYSTEM Providing, fixing, testing and commissioning of mild steel black pipes (IS: 1239 Part-I) heavy class including cutting welding etc. and providing all fittings viz., flanges, bends, tees, elbows, reducers, clamps, hangers etc. wall/slabs and making good complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved shade. 65 mm dia.
SECTION-III: SPRINKLER SYSTEM Providing, fixing, testing and commissioning of mild steel black pipes (IS: 1239 Part-I) heavy class including cutting welding etc. and providing all fittings viz., flanges, bends, tees, elbows, reducers, clamps, hangers etc. wall/slabs and making good complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved shade. 80 mm dia.
Providing, fixing, testing and commissioning of gun-metal ball valves ISI marked screwed type tested to pressure as per IS: 778 of following sizes: (For Sprinkler Test Line) 25mm dia.
Providing, fixing, testing and commissioning pendent/upright of 15mm dia quartzoid bulb type sprinkler set to operate at 68 deg. C (UL/FM/FOC/TAC listed approved).
Providing, fixing, testing and commissioning 25mm dia SS flexible drop for sprinkler of 1000 mm dia long. (UL/FM/FOC/TAC listed approved).
Providing and fixing double flanged cast iron butterfly valves complete with bolts, nuts 1.5mm CAF gasket complete conforming to IS: 13095. 80 mm dia.
Providing and fixing Installation control valve with turbine type automatic alarm gong with quarter mile hooter, also with control valve drain and test drive as per manufacturer's speicifcations. (Size 100mm dia ICV ).
Providing and fixing cast iron slim seal wafer type Butterfly valve (as per IS: 5312) including nuts, bolts 1.5mm thick CAF gasket sheets complete in all respects. 100mm
Supply & Fixing of Flow Switch in Sprinkler headres. 100 mm dia (Honewell Make)
SECTION - IV : FIRE DETECTION AND ALARM SYSTEMS SYSTEMS Supply , Erection , Testing, & Commissioning of Analogue Addressable type Multi Sensor.
SECTION - IV : FIRE DETECTION AND ALARM SYSTEMS SYSTEMS Supply, erection, testing & commissioning of analogue addressable Heat Detector
SECTION - IV : FIRE DETECTION AND ALARM SYSTEMS SYSTEMS Supply, erection, testing & commissioning of Hooter/ strobe (In Built CONTROL MODULE)
SECTION - IV : FIRE DETECTION AND ALARM SYSTEMS SYSTEMS Supply, erection, testing & commissioning of analogue addressable Manual Call point
SECTION - IV : FIRE DETECTION AND ALARM SYSTEMS SYSTEMS Supply, Erection of FRLS Round Pvc shelded cable comlplete with lugs, laying and termination 2C x 1.5 mm ( loop cable)
External Electrification work
CAST RESIN TYPE DRY TRANSFORMER Supply, Erection, Testing & Commissioning of 250kVA, 11kV/415V, 350MVA, Dyn11, AN type indoor mounting copper wound, "Cast Resin Type Dry Transformer" with Class- H insulation,off load tap link, winding temperature indicator, bidirectional rollers, marshalling box, cable box with HT disconnecting chamber and LT disconnecting chamber on LT side and all other accessories as required. The off load tap link with (+)5% and (-)5% tappings in step of 2.5%. The installation shall confirm IS : 10028.1981(Part II) & amended upto date. The rate shall be inclusive of necessary civil works, mounting channels, earthing etc. complete in all respect.
HT CABLE Supply & Laying of "11kV, 3C HT XLPE(E) Al. Armoured Cable". The rate shall be inclusive of necessary supporting & clamping arrangement for laying of cables within tray/pipe/trench. The installation shall confirm IS : 1255.1983 & amended upto date. 11KV, 3&1/2C X 300SQMM XLPE ALUMINIUM CABLE.
Supply & Laying of "11kV, 3C HT XLPE(E) Al. Armoured Cable". The rate shall be inclusive of necessary supporting & clamping arrangement for laying of cables within tray/pipe/trench. The installation shall confirm IS : 1255.1983 & amended upto date. Supplying of following size of PVC/XLPE insulated and PVCSheathed 1.1 KV gd Mtrs. Solid Aluminium conductor up to 10 sqmm, balance stranded conductor, XLPE Insulated, cores laid up, PVC tape innersheathed, Armour (Aluminium wire for single core up to 70 sqmm, balance Aluminium Strip, Galvanised wire for cables upto 2X10 sqmm, 3X10 sqmm, 4X6 sqmm & balance all galvanised steel strip),. extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908 (Part 1) 1988 armoured U.G cable as specified and directed by the department. (Havells/RR Kabels /Polycab or equivelent make as approved by this Dept.). 185.00 Sqmm 3.5 Core Armoured UG Cable.
Supply, Erection, testing and commissioning of G.I Steel tubular pole for extension of H.T line as per direction & specified by the Deptt. (Nezone/ consoul make
STATUTORY CHARGES TO BE PAID TO APDCL Liasoning & Obtaining preliminary & final NOC from the "Directorate Of Electricity".
Payment of Load Security of 10 KW (As per APDCL)
Supplying including installation, commissioning of DTR fencing as per APDCL
Supplying Meter, including installation, commissioning of 11 KV CT/PT, 11 KV Energy Energy Meter Cabinet, Supervision Charge to be to APDCL etc. APDCL Estimate
DG Design, Manufacture, Supply, erection, testing and commissioning of 250kVA, 415V, 3 Phase, 4 Wire, 50 Hz at 0.8 p.f. prime continuous (actual) rating radiator cooled diesel generating set in acoustic enclosure with radiator, Water cooled engine, PMG, base frame, Alternator, Static Excitation System, Lube Oil System, Electronic Governor, 24V Batteries & Battery Charger, Instrumentation, day oil fuel tank, Residential Silencer with Bellows, Alarms, microprocessor based Engine Control Panel, AVR Panel ,equivalent for AMF facility, termination adopter box suitable for XLPE insulated aluminium cables, drip trays space for mounting all associated equipments/ works as per specification including providing common base plate, anti vibration isolators, foundation bolts etc.The civil works for foundation for D.G.Set shall be included in the rate. But other accessories like grouting screws, anti-vibration pads etc. shall be included in the rate. Alternator shall have class H insulation and rated for 100 KW output at 50°C. Emergency stop push button for individual DG set shall be located at the exit door. Engine shall not be derated upto 50 deg.C ambient. Note: Piping between day oil tank & DG set shall be included.
Construction of R.C.C. Slabwith RCC Post for holding of Transformer
M/S I.S. Trading Co
M/S MAHAABALA CONSTRUCTION PVT. LTD.
VERSHA TECHNOTRADE PVT LTD
globalenterprises
Abdul Quddus
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].