Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.9 LAccepted-AOC | L1 | Accepted-AOC BEING L1 BIDDER | |
| 2 | L2₹47.6 L+₹1.3 L (2.72%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹47.9 L+₹1.6 L (3.51%)Rejected-Finance HAMILTONGANJ NETAJI PALLY NEAR ICE FACTORY DISTT ALIPURDUAR WEST BENGAL 735 214 | ALIPURDUAR | WEST BENGAL | 735214 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹48.7 L+₹2.4 L (5.26%)Rejected-Finance INDEX NO D 35 ADG NEI GUWAHATI OLD HASIMARA POST HASIMARA DIST ALIPURDUAR WB PIN 735215 | ALIPURDUAR | WEST BENGAL | 735215 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹49.9 L+₹3.6 L (7.79%)Rejected-Finance OLD HASIMARA PO HASIMARA DISTT ALIIPURDUAR WB PIN 735215 | HASIMARA | ALIPURDUAR | WEST BENGAL | 735215 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹42.5 L
EMD Value
₹85,000
Closing Date
16 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) HASIMARA
GE (AF) HASIMARA, PO-HASIMARA, DIST- ALIPURDUAR, PIN-735215
IMPROVEMENT OF LT SUPPLY DISTRIBUTION AT LIVING AREA BILLETS NC (E) AREA AT AF STN HASIMRA
2024_MES_676498_1
C/8815/2024-25/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) HASIMARA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) HASIMARA
₹85,000
Yes
28 Oct 2024
25 Sept 2024
18 Oct 2024
25 Sept 2024
16 Oct 2024
9 Oct 2024
Amount
Supply, installation, testing and commissioning of out door type LT distribution box made out of 3.15mm thick CRCA sheet out door type, CPRI approved manufacture totally enclosed weather dust and vermin proof as per IS with front and rear opening suitable locking arrangement having copper bus bar strip size 40mm x10mm capacity for RYB and neutral and insulated with insulators, including connecting incoming and outgoing cables necessary PCC (1:3:6) in foundation and made out of 50 x 50 x 6mm angle iron grouted at ground above 30cm from ground level comprising the following, complete all as specified and directed:- Incoming : (i) MCCB 200 Amp 4 pole 36 KA with thermal magnetic protection - 01 No. (ii) Digital multi function Meter 01 - 500 Volt (iii) RYB Indicating lamps -03 Nos. (iv) CT's 100 /5 Amp - Set of three Outgoing : (i) MCCB 160 Amp 4 pole 25 KA with thermal magnetic protection - 01 No. (ii) MCCB 100 Amp 4 pole 10 KA with thermal magnetic protection - 02 Nos. (iii) MCCB 63 Amp 4 pole 10 KA with thermal magnetic protection - 02 Nos. Note : Cost of necessary internal wiring for meters, CTs, indication lamps,etc and rigid bus bar connections from bus bar to MCCB terminals connection bus to MCCB/MCB connections shall deemed to be included in the unit quoted rate.
Excavation in trenches not exceeding 1.5 metre wide and not exc 1.5 metre in depth for foundation of pole/stay, or cable trenches etc & n. exc 10 Sqm on plan and getting out in soft/loose soil, complete all as specified and directed.
Returning filling in incl spreading, leveling watering and well ramming in layers not exceeding 25cm in soft/loose soil, complete all as specified and directed.
Removing excavated materials to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point in any type of soil, complete all as specified and directed.
Supply & laying double walled corrugated (DWC) HDPE duct pipe of 80mm dia conforming to IS approved colour complete with fittings for cable protection, complete all as specified and directed.
Supply & laying double walled corrugated (DWC) HDPE duct pipe of 40mm dia conforming to IS approved colour complete with fittings for cable protection, complete all as specified and directed.
Supply, filling in trenches, spreading, leveling sand cushioning 8cm below cable and 15cm above the cable punned down to 18cm for under ground cable, complete all as specified and directed. (Note : Punned thickness shall be measured for payment)
M&L for sub class ‘B’ old size bricks, burnt clay bricks, laid flat, dry in trenches for cable protection, complete all as specified and directed.
Supply, laying, jointing and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 Sqmm 3.5 core including taking down old unserviceable UG cable of any description, complete all as specified and directed.
All as per item No. 9.00 here-in-before but cross sectional area 120 Sqmm 3.5 core, complete all as specified and directed.
All as per item No. 9.00 here-in-before but cross sectional area 70 Sqmm 3.5 core, complete all as specified and directed.
All as per item No. 9.00 here-in-before but cross sectional area 50 Sqmm 3.5 core, complete all as specified and directed.
All as per item No. 9.00 here-in-before but cross sectional area 35 Sqmm 3.5 core, complete all as specified and directed.
All as per item No. 9.00 here-in-before but cross sectional area 25 Sqmm 4 core, complete all as specified and directed.
All as per item No. 9.00 here-in-before but cross sectional area 16 Sqmm 4 core, complete all as specified and directed.
All as per item No. 9.00 here-in-before but cross sectional area 10 Sqmm 4 core, complete all as specified and directed.
S & F junction box made from SMC/FRP sheet ready made of size 350 x 250 x 138mm with aluminium bus bar of 100 Amp capacity for RYB and half for neutral made in suitable size fixed inside the junction box with necessary supporting insulators fixed on hylem sheet, MS sheet steel fixed inside the bottom portion of box to connect the cable gland complete, entire assembly fixed to pole/wall with MS clamp 25 x 5mm and nuts & bolts, or inside the copping of pole /post top including MCB SP 6 Amp 10 KA 240 V - 1 No, with necessary size copper lugs for connecting cables from junction box to fittings including dismantling of old junction box of any size, complete all as specified and directed.
S & F cable 3 core FR PVC insulated round sheathed copper conductor of size 1.5 Sq mm passing through PVC conduit from junction box to fitting, complete all as specified and directed. Note: PVC conduit is measured and paid seperately.
S & F in replacement rigid PVC non metalic conduit 20mm dia on pole with necessary bend elbow, couplers, check nuts, FI clamp 40 x 4mm poles and nuts & bolts, PVC flexible conduit, connected to junction box to fitting etc, complete all as specified and directed including painting to clamps.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6.0mm thick buried directly in ground vertically to a depth not less than 2.25 meter below ground level with top edge of earth plate at a depth not less than 1.5 meter below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized earth lead wire 4mm thick dia by means of bolts, nuts and washers of galvanized iron or steel and thimbles and other end of the earth strip connected to earthing test point/equipment and protected by galvanized iron pipe light grade 20mm bore, up to earthing test point/equipment fixed with required number of mild steel clamp made out of 25mm x 3mm flat iron and perforated water pipe 20mm dia. GI medium grade of length 2.25 meter and top with socket & plug and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in PCC (1:2:4) type B-1 and 40mm thick pre-cast RCC (1:2:4) type B-0 cover reinforcement with 40mm x 40mm x 6mm MS angle iron frame, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 including dismantling of old unserviceable earthing of any description, complete all as specified and directed. Note: - (i) GI strip up to earth test point/equipment is included in this item. (ii) Outer edge of earth pit chamber shall be 1.5 meter away from the outer edge of PCC chamber.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6.0mm thick buried directly in ground vertically to a depth not less than 2.25 meter below ground level with top edge of earth plate at a depth not less than 1.5 meter below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron strip 25mm x 4mm thick as earth lead by means of bolts, nuts and washers of galvanized iron or steel and thimbles and other end of the earth strip connected to earthing test point/equipment and protected by galvanized iron pipe light grade 40mm bore, up to earthing test point/equipment fixed with required number of mild steel clamp made out of 25mm x 3mm flat iron and perforated water pipe 20mm dia. GI medium grade of length 2.25 meter and top with socket & plug and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mm thick pre-cast RCC (1:2:4) type B-0 cover with 40mm x 40mm x 6mm MS angle iron frame, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 including dismantling of old unserviceable earthing of any description, complete all as specified and directede. Note: - (i) GI strip up to earth test point/equipment is included in this item. (ii) Outer edge of earth pit chamber shall be 1.5 meter away from the outer edge of PCC chamber.
M&L for earth continuity conductor or main earthing lead 4mm dia fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire, complete all as specified and directed
Horizontal boring under the road/pavment/hardstanding (with manual method) below 1mtr from the road surface and dia of hole not exc 100mm, with out damaging the existing road, getting out and disposal of soil to a distance not exceeding 50m from the site of work and making good both the ends, complete all as specified and directed.
M&L for 80mm bore GI tubing, light grade, with necessary fittings such for cable protection, laid in trenches, complete all as specified and directed. Note: Boring/Earth work shall be measured and paid separately.
M&L for 50mm bore GI tubing, light grade, with necessary fittings such for cable protection, laid in trenches, complete all as specified and directed. Note: Boring/Earth work shall be measured and paid separately.
S&F sheet metal enclosure for double door MCB DBs, phosphatised, powder coated, Triple Pole & Neutral (TPN), suitable for 8 way, 240 volts, IP 43 & IK 09 with metal door fixed on wall with din rail, neutral and earth bar, fixed in proper position including taking down old unserviceable one, complete all as specified and directed.
S&F in repair MCB SPN 6 to 32 Amps, 10 KA, 'B' curve, 240 volts with overload and short circuit protection, complete all as specified and directed.
S&F in repair MCB SP 6 to 32 Amps, 10 KA, 'B' curve, 240 volts with overload and short circuit protection, complete all as specified and directed.
S&F in replacement sheet metal enclouser for doble door vertical DBs made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mouting VTPN 4 Way 415 Volt ISI marked 250 Amps busbar stove enameled dust and vermin proof, IP:43 protection suitable for incorporation FP MCCB (V-Tech) N1 frame upto 125A, complete all as specified and directed
S&F of MCCB TPN 100 Amp, 16 KA, 4 pole, 415 Volt, Ics = 100% Icu, alongwith mild steel enclosure and spreader link and suitable cable gland for incoming and outgoing cable and fixing arrangement on wall, complete all as specified and directed.
Taking down old ACSR/AAC conductor and removing from site of work, complete all as specified and directed
Taking down old pin insulator and removing from site of work, complete all as specified and directed
Dismatling old cross arm from poles including bracket of any size/shape and removing from site of work, complete all as specified and directed
Note: An amount of Rs 39,836.24 on account of Credit Schedule for schedule 'A' part - II shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/S DEY ENTERPRISE (BID ID -3140689)
MAJUMDER ENTERPRISE (BID ID -3140714)
M/S ANNI ENTERPRISE (BID ID -3140633)
M/S BIJAY KUMAR SHIVA (BID ID -3140670)
M/S P K AGARWALA (BID ID -3140634)
DEEP NIRMAN (BID ID -3140972)
M/S ASHOK ENTERPRISE (BID ID -3140739)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .