Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.8 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹23.9 L+₹10,952.20 (0.46%)Rejected-Finance | L2 | Rejected-Finance Second lowest | |
| 3 | L3₹24.9 L+₹1.1 L (4.47%)Rejected-Finance | L3 | Rejected-Finance Third lowest | |
| 4 | L4₹24.9 L+₹1.1 L (4.53%)Rejected-Finance | L4 | Rejected-Finance Fourth lowest | |
| 5 | L5₹25.5 L+₹1.7 L (7.04%)Rejected-Finance | L5 | Rejected-Finance Fifth lowest |
Tender Value
₹30.8 L
EMD Value
₹61,600
Closing Date
13 Sept 2024, 6:00 pmClosed
GE AF Sambra
GE AF Sambra ATS Sambra Belgaum 591124
PROVN OF WEATHER SHELTER AND ASSOCIATED WORKS AT MT SECTION AND PROVN OF MONSOON SHEDS (02 JOBS) AT ATS BELAGAVI UNDER GE (AF) SAMBRA
2024_MES_667454_1
GE(AF)/SAM/TOK-24 OF 2024-25
Open Tender
Civil Works
Item Rate
180 days
GE AF Sambra
Please refer Tender documents
8 documents required · 8 mandatory
₹500
GE AF Sambra
₹61,600
Yes
22 Oct 2024
23 Jul 2024
16 Sept 2024
23 Jul 2024
13 Sept 2024
9 Aug 2024
Amount
Demolition of un-reinforced cement concrete in ground floor and pavings exc 15 cm thick (below or above ground level) and removing all the rubbish as directed complete all as specified and directed
Taking down shutters of any description exc 1 Sqm but not exc 2 Sqm and refixing in same opening, including easing and adjusting and also refixing builders hardware as required including renewal of unserviceable screws complete all as specified and directed
Excavation in trenches n. exc. 1.50m wide and n exc 1.5 m in depth; for foundation etc.; or for shafts, wells, cesspits, manholes, pier holes not exc 10 sqm on plan and n exc 1.5m in depth and getting out in hard/dense soil complete all as specified and directed.
M & L for PCC 1:4:8, type D-2 (using 40mm graded crushed stone aggregates) as in foundations complete all as specified and directed
M&L for PCC 1:2:4, type B2 (using 20mm graded crushed stone aggregates) in foundation filling and mass concrete complete all as specified and directed
Surface excavation n exc 30cm deep and avg 27cm deep and getting out in hard/dense soil complete all as specified and directed
M&L for pre-cast cement concrete block masonry with solid blocks type C1, PCC 1:3:6 (using 20mm graded crushed stone aggregates), exc 10cm in width and setting in CM 1:6 complete all as specified and as directed.
M&L for plain cement concrete 1:2:4, type B1 (using 20mm graded crushed stone aggregates) as in coping and edging of paver blocks and like including weathering slightly rounded or chamfered angles and throating and including necessary use and waste of form work complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers n exc 25 cm thick complete all as specified and directed
Removing surplus excavated soil and debries obtained from demolition to a distance exceeding 250m but n exc 500m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and directed
M & L for broken stone or boulder hardcore of gauge n exc 63 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed
M&L for 100mm thick PCC 1:4:8, type D2 (using 40mm graded stone aggregates) as in sub base of flooring complete all as specified and directed
M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drives ways or light traffic parking etc., of required strength thickness and size/shape, made by table vibratory method using over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/laying of interlocking paver blocks in to the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed
M&L for 15 mm thick cement plaster on fair face of brick work or concrete surface in CM 1:4 for wall finished even & fair complete all as specified and directed
M&L for applying Two coats of acrylic emulsion paint of Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives over and including priming coat of exterior primer applied on new plastered surfaces of walls complete all as specified and directed
M&L for steel work in tubular trusses, vertical posts, rafters, purlins and supporting member for cladding including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade st - 240 complete all as specified and as directed.
M&L for mild steel plates (plain or chequred) channel, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 410 W (Gde-E-250) Quality - B including fixing with riveting, bolting or welding complete all as specified and directed
M & L for mild steel work for plain angle cleats for securing purlins to trusses or rafters and MS truss with vertical posts including necessary drilling, bolting or welding etc., and similar work conforming to Fe-290 Gde E-165 etc., complete all as specified and directed.
M & L for mild steel work for wind ties for roof including securing bolts including all necessary drilling, bolting or riveting etc., and similar work conforming to Fe-290 Gde E-165 etc., complete all as specified and directed.
M&L for preparation of steel surfaces of any description over 10 cm in width or girth not otherwise described and two coat of synthetic enamel paint over one coat of red oxide Zinc chromate primer complete all as specified and as directed.
M&L for preparation of new steel surfaces of any discription not exceeding 10 cm width and girth and applying two coats of synthetic enamel paint over one coat of red oxide Zinc chromate primer complete all as specified and directed
S & F pre painted galvalume aluminium Zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed
M & L for pre painted galvalume aluminium Zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 MPa as in ridges, roof overing/cladding to wall, fixed with self tapping screws complete all as specified and directed
Spreading and levelling of soil obtained from excavation in layers n exc. 25cm thick in floor, well ramming including watering as required complete all as specified and as directed.
M&L for 75mm thick PCC 1:4:8, type D2 (using 40mm stone crushed stone aggregates) as in sub base under floor complete all as specified and directed
M&L for 25mm thick PCC 1:2:4, type B1 (using 20mm graded crushed stone aggregates) as in floor complete all as specified and directed
M&L for joint free non skid ceramic coloured tiles, 7 to 8mm thick (square or rectangular), area of each tile exc 0.18 sqm but not exc 0.38 sqm, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles as in floors laid over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed
M&L for non skid ceramic coloured tiles in vertical surfaces as in skirting, dado, etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 10mm thick backing coat in cement mortar 1:3 complete all as specified and directed
M&L for non skid ceramic tiles, coloured, 7 to 8mm thick (square or rectangular), area of each tile exc 0.06 sqm but not exc 0.11 sqm, set and jointed in neat cement slurry and pointed in white cement with pigment to match the colour of tiles as in floors laid over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed
M&L for glazed ceramic coloured tiles in vertical surface, 450mmX300mmX7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including 10mm thick backing coat in cement mortar 1:4 complete all as specified and directed
M&l for machine cut Cudappah stone slab 20mm to 25mm thick fixed to wall independantly as urinal partition, cutting grooves in wall and jointed with grey cement mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M&L for rounding to edges of cudappa stone slabs one edge, such as in steps, cooking platform and other similar situations complete all as specified and directed
S&F vitreous China Urinal, Half stall type of size 59cm X39cm X37.50cm complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement flush pipe, grating and union for discharge pipe complete all as specified and as directed.
S&F urinal spreader of PTMT any colour for fixing with 15mm dia pipe. (minimum weight 60gms) complete all as specified and directed
S&F vitreous China wash basin, white, flat back, size 550mmx400mm, including cutting for and pinning in ends of brackets or errecting stand waste fitting and union, plugs and chain and connecting upto supply pipes complete all as specified and as directed.
S&F pillar taps, 15mm dia, cast copper alloy, with capstan heads, chromium plated screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and flynuts, screwed for iron pipe and fixed complete all as specified and directed
S&F PVC connection 15mm size with PTMT nuts of length 600mm complete all as specified and directed
S&F angle stop valve 15mm dia of PTMT any colour high pressure screwed for iron pipe and fixed complete all as specified and directed
S&F 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed in wall/ floor with necessary clamping as required complete all as specified and directed.
S&F 50mm dia High density polyethylene pipes (HDPE) of pressure rating 6 kgf / Sq cm fixed to wall, ceiling or in floor complete all as specified and directed.
S&F 75mm PVC (SWR) junction single (Single T) equal or unequal complete all as specified and directed.
S&F PVC bends for 75 mm bore pipe complete all as specified and directed.
S&F (SWR) floor trap 75 mm dia, plain with grating including jointing with solvent cement all as specified and directed
S&F unplasticised PVC pipes 25mm dia of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe including all fitting such as bends,elbows, tees tank connector and fixing to existing pipe complete all as specified and directed
S&F unplasticised PVC pipes 15mm dia of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe including all fitting such as bends,elbows, tees tank connector complete all as specified and directed
S&F factory made single extruded WPC (Wood Polymer Composite) solid door & other Frames/Chowkhat of size 65 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate andnatural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. Note: For WPC solid door frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
S&F factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicityindex of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer- In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)
S&F 100 mm long butt hinges medium weight cold rolled to door frame with necessary screwing or bolting complete all as specified and directed
S&F 150 mm long aluminium anodised handle fabricated type complete all as specified and directed
S&F 150 mm long aluminium anodised barrel tower bolt complete all as specified and directed.
S&F 300 mm Aluminium alloy, anodised sliding door bolt with hasp and stapple bolt type complete all as specified and directed
S&F Anodised aluminium powder coated frame for doors, windows, ventilators with one or more rebates including jointing cleat for fixing complete all as specified and directed
S&F Anodised aluminium powder coated windows and ventilators louver type (up/down) with frame, aluminium sections weighing 0.55 kg/m including necessary jointing cleats, glazing clips, rubber packing, anodised aluminium powder coated snap beading, screws complete all as specified and directed
S&F Anodised aluminium powder coated grills of approved design/pattern, with approved standard section and fixed to the existing window frame with CP brass / stainless steel screws @200 centre to centre, including cutting the grills to proper opening size for fixing and operation of handles and fixing fixing approved anodised aluminium standard section around the opening complete all as specified and directed
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples or steel screws or aluminium beading complete all as specified and directed
S&F sheet plain glass 5.5 mm thick, ordinary quality, in squares not exceeding 0.5 Square Metre for each pane, glazing with oil putty or aluminium beading complete all as specified and directed
S&F figured glass, pin head type 4 mm thick, not exceeding 0.5 Sqm for each pane, glazing with oil putty or aluminium beading complete all as specified and directed
S&F rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy brackets framing (Beam, tee, angle, channel, or flat section) including distance pieces, cleats etc. of Fe 410-W (Gde E-250) Quality-B complete all as specified and directed
ASHIRWAD ELECTRICALS (BID ID -3094052)
RAJENDRA KRISHNA SARAF (BID ID -3088801)
M/s B C CHOUGULE (BID ID -3094761)
M/S MAHADEV M PATIL (BID ID -3078410)
M/S ADITYA CONSTRUCTIONS (BID ID -3080848)
Manak landmarks (BID ID -3089780)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .