PROVN OF FENCING WITH GATES 02 NOS AND SECURITY LIGHTS AT OFFICERS MESS AT YEDDUMAILARAM 1.5 TON SPLIT TYPE AC IN BLDG NO 66 SPL REPAIR TO WS DISTRIBUTION NETWORK AT ARTY CENTRE AND PROVN OF BATHING SHED AT ARTY CENTRE UNDER GE GOLCONDA
2023_MES_584539_1
8652/E8
Open Tender
Civil Works
Item Rate
180 days
Hyderabad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Golconda
₹73,000
Yes
12 Apr 2023
6 Mar 2023
12 Apr 2023
6 Mar 2023
10 Apr 2023
20 Mar 2023
Amount
Supply, install test and commission hi wall split units indoor/out door complete with cordless remote control unit and with built air ioniser and plasma filter for better indoor air quality with minimum 3 Star rating and EER 3.2 Of Capacity 1.5 TR
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3 KVA
M&L for Submain wiring with two single core PVC (FRLS) insulated flexible copper conductor cable of size 6 Sqmm and one single core PVC (FRLS) insulated unsheathed flexible copper conductor cable green colour of size 6.0 Sqmm as earth lead in and including PVC conduit medium grade with all fittings suitable for concealed type and making good the disturbed wall surfaces to match with existing specification as required complete all as specified and directed at site.
S&F in repair single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 Amps MCB complete all as specifed and directed at site.
Excavation in trenches n.exc 1.50m wide and n. exc 1.50m in depth and getting out in hard/dense soil complete all as specified and directed.
Excavating post holes or similar holes, each not exceeding 0.5 Cum, getting out in Hard/ Dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc., complete all as specified and directed.
M & L for PCC type D2, 1:4:8 (using 40mm graded stone Aggregate) as in foundations, filling and mass Concrete complete all as specified and directed.
M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed.
M&L for Rendering 15 mm thick in CM (1:4) on fair faces of stone surface of walls finished even and smooth w/o using extra cement complete all as specified and directed.
Labour only for Spreading, Levelling and well ramming including watering as required in layers n.exc 25 cm thick the approved excavated earth in plinth.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point in soils
M&L brick work with fly ash bricks built in CM 1:4 straight or curved on plan exc 6 mtr mean radius complete all as specified and directed.
M&L for providing, cement concrete 1:3:6 Type C1 using 20 mm graded stone aggregate as in coping including cost of necessary formwork complete all as specified and directed.
M&L for plain Cement Concrete Type C1 1:3:6 (using 20 mm graded stone aggregate) in foundation filling, mass concrete and similar works and for MS Pipe fixing or for fencing post.
M&L for Mild steel work in Angles, bars, flats etc. as in fencing post, struts including cutting tops to shape as directed including embedding in concrete and all necessary drilling holes, bolting or riveting, welding, notching for wire and similar work confirming to Fe 290 Gde-E-165 complete all as specified and directed.
S & F in repairs galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc. complete all as specified and directed.
S & F for Steel work in tubular trusses & vertical post including special shaped washer etc using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade st-240 complete all as specified and directed.
S&F MS Plain plates, square cut, with riveted, bolted or welded attachment Fe-410-W (Gde-E-250) quality A complete all as specified and directed.
M & L for Two coats of synthetic enamel paint to new steel surfaces over 10cm width or girth including preparation of new surfaces and one coat of red oxide primer complete all as specified and directed.
M&L for Rendering 15 mm thick in CM (1:4) on fair faces of brick or concrete surface of walls finished even and smooth without using extra cement complete all as specified and directed.
M&L rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement including mixing of water proofing compound (WPC Should me measured seperately) complete all as specified and directed.
Supply only Integral water proofing compound
M&L for rendering 10mm thick in CM 1:6 fair faces of brick or concrete surfaces finished even and smooth (without using extra cement) complete all as specified and directed.
M & L preparation of new surfaces of walls plastered or unplastered etc and applying two coat of cement based paint paint on wall surfaces complete all as specified and directed.
M&L for three coats of white wash on new plastered surfaces of walls including preperation complete all as specified and directed.
M & L pre-painted galvalume aluminium zinc coating GI based corrugated sheet 0.50 mm thick of any colour having tensile strength 550 mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof overing/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for Hard core of guage n.exc 63 mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M & L for 75mm thick cement concrete type D-2, 1:4:8 (using 40mm graded stone aggregate) as in sub base to floor complete all as specified and directed.
Use & waste Form work to sides of concrete foundations rafts, footing, base of columns, sides & soffits of foundation etc. for rough finished flat surfaces complete all as specified and directed.
Use & waste formwork, rectangular or polygonal to sides of pillars, posts, struts, columns and stanchions for rough finished surfaces flat complete all as specified and directed.
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) rough finished surface complete all as specified and directed.
Use and waste of formwork to edges of concrete flats, treads, breaks in floors,window cills, concrete railings,openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide rough finished surfaces complete all as specified and directed.
M&L RCC (Nominal Mix) Type B1 (1:2:4) (using 20 mm graded stone aggregate) in foundations including rafts, footings and mass concrete complete all as specified and directed.
M&L RCC Type B1(using 20 mm graded stone aggregate) in Columns, piers, posts and struts complete all as specified and directed.
M&L for RCC M15, 1:2:4 (using 20 mm graded stone aggregate) nominal mix for slabs supported on walls, beams and columns in floors, roofs, landings balconies canopies, desk slabs and in shelves and the like complete all as specified and directed.
Supply only MS galvanised chain link fencing haevy zinc coated (Hot dip), aparture size 50mm and wire of 8 SWG (4 mm) complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standard, rails, iron angle posts, straining bolts etc incl provision of binding wire complete all as specified and directed.
S & F mild steel screw bolts of 11 to 15mm diameter of neck (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 5cm and not exc 10cm complete all as specified and directed.
Supply only MS round bars, 10mm dia & over as in line wires for chain link fencing.
M&L Mild steel work framed as in ornamental and intricate design framed and hung gates, including pintle hinges, stops, hand made sliding bolts etc. and similar work confirming to Fe 290 Gde - E - 165 complete all as specified and directed.
M&L MS TMT bars 5 mm to 10 mm dia., cut to length, bent to shape required, in stirrups and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed.
M&L for MS TMT bars 10mm dia and over, cut to length bent to shape required including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed not less than 0.9 mm dia or securing with clips) complete all as specified and directed.
-Ditto- but 6 to 8 mm dia bars
M&L for 40 mm thick PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in floors, surface finished even and smooth using extra cement complete all as specified and directed.
M & L for 75 mm thick PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate ) as in plinth protection finished even aned smooth without usisng extra cement complete all as specified and directed.
M&L for GI pipes medium grade 15 mm dia with all fittings, fixed to walls and ceilings or laid in floors complete all as specified and directed.
M&L for GI pipes medium grade 25 mm dia with all fittings, fixed to walls and ceilings or laid in floors complete all as specified and directed.
S & F gun metal gate or globe valve, 25mm bore dia with iron wheel head screwed both ends for iron pipe complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks (cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I of capacity 1000 litre complete all as specified and directed.
S&F ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed to 25mm bore pipe complete all as specified and directed.
S & F 110 MM dia PVC (SWR) pipe single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S & F 110 mm dia PVC (SWR) bends
S & F 75mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S&F PVC (SWR) floor trap 75mm dia, plain with gratings including jointing with solvent cement complete all as specified and directed.
S & F 75 mm dia PVC (SWR) bends complete all as specified and directed.
S&F vitreous china wash basin, white, flat back size 550 x 400mm including 01 Nos cast copper alloy 15mm CP pillar tap, 01 Nos 32mm waste coupling and pipe, one pair of MS bracket, cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed.
Supply and erect Steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts, screws as specified type 410 SP-31(9.00 metre long) including two coats of bituminous paint internally and externally for the portion embedded in concrete and two coats of aluminium paint over one coat of red oxide primer to external/ exposed surfaces all as specified and directed. Note:The quoted rate is deemed to include for PCC 1:4:8 type D2 as in foundation, PCC 1:3:6 type C1 as in coping 450mm above GL incl formwork and earth work and excavation required for founding depth as per IS for the poles.
Supply and fix LED street light fitting 90W 230 V ac out door type with new generation energy saving and environmental friendly long life made up of pressure die cast aluminium housing with high efficiency LEDs as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 complete all as specified and directed.
S&F Hot press moulded SMC Junction box of size 270 mm x 200 mm x 135 mm with right openable hinged door with two number aluminium bus bars mounted on porcelain insulator including clamps of MS flat iron 25 x 3 mm with bolts and nuts and including one MCB SP upto 6A, 10 KA for ON/OFF street light, fixed on pole including taking down old juction box, complete all as specified and directed.
S&L in trenches/fixed to walls/poles etc., and testing and commissioning XLPE insulated and PVC sheathed heavy duty LT 1100 Volts grade armoured under ground cable with stranded aluminium conductor of 2 core 10 Sqmm size complete all as specified and directed.
S&L in trenches/fixed to walls/poles etc., and testing and commissioning XLPE insulated and PVC sheathed heavy duty LT 1100 Volts grade armoured under ground cable with stranded aluminium conductor of 2 core 16 Sqmm size complete all as specified and directed.
M&L for 2 run of single core 2.5 Sq.mm size PVC insulated , unsheathed , multistranded copper conductor cables in and including 20 mm PVC conduit including clamps alongwith nuts and bolts and connecting upto street light fitting complete all as specified and directed.
Supply and spread approved dry river sand for cable laying /foundations/Cable duct including watering and consolidation, cushioning of cable laid in trenches complete all as all as specified and directed. Note:- Punned thickness will be measured for payment purpose.
M&L brick protection with common burnt bricks sub class ‘B’ of size 230 x 113 x 75mm for cable protection complete all as directed and directed.
M & L cutting of road, hard standing made of concrete or premix carpet, WBM, soiling and morrum filling including excavation for laying of cable pipe all as directed and making good the road/hard standing by using all old/new materials and with PCC (1:2:4) etc, required to match with the existing surface complete all as specified and directed.
S & L GI tubing of 40mm dia, light grade, with all fittings for the following sizes of cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete all as specified and directed.
S&F RUBY LED POST TOP (Gate Light) 25 Watt new generation, IP 65 LED post-top family, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source complete all as specified and directed at site.
M&L Earthing complete with galvanized steel with plate electrode 60 cm x 60 cm x 6.3mm thick buried directly in ground (earth kit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized steel strip 25mm x 4mm dia by means of bolts, nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR part-I connected to earth test point incl necessary earth work and excavation PCC 1:3:6 type C1 using 20mm graded stone aggregate for earth chamber with SSR Part-II RCC cover 50mm thick 1:2:4 mix type B1, using 8mm dia TMT bars reinforcement @ 140mm c/c both ways, watering funnel with water pipe GI pipe 15mm dia medium grade and protection pipe GI 40 mm dia, light grade all as specified and directed in SSR Part II. Earth strip and protection pipe beyond 7.5m shall be measured and paid separately.
Supply & fixing GI water tubing medium grade of 15mm bore complete with all fittings such as bends elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc including taking up or down existing GI tubing with fittings complete all as specified and directed.
Supply & fixing GI water tubing medium grade of 20mm bore complete with all fittings such as bends elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc including taking up or down existing GI tubing with fittings complete all as specified and directed.
Supply & fixing GI water tubing medium grade of 25mm bore complete with all fittings such as bends elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc including taking up or down existing GI tubing with fittings complete all as specified and directed.
Supply & fixing GI water tubing medium grade of 40mm bore complete with all fittings such as bends elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc including taking up or down existing GI tubing with fittings complete all as specified and directed.
Supply & fixing GI water tubing medium grade of 50mm bore complete with all fittings such as bends elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc including taking up or down existing GI tubing with fittings complete all as specified and directed.
Supply & fixing GI water tubing medium grade of 80mm bore complete with all fittings such as bends elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc including taking up or down existing GI tubing with fittings complete all as specified and directed.
M&L for 100 mm dia Ductile iron pipes with spigot and socket end incl titon joints, Class K-9 supplied and laid including taking down existing CI/DI pipes complete all as specified and directed.
M&L for 150 mm dia Ductile iron pipes with spigot and socket end incl titon joints, Class K-9 supplied and laid including taking down existing CI/DI pipes complete all as specified and directed.
Supply & fixing in repairs gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe of 15mm bore including taking down existing one complete all as specified and directed.
Supply & fixing in repairs gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe of 20mm bore including taking down existing one complete all as specified and directed.
Supply & fixing in repairs gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe of 25mm bore including taking down existing one complete all as specified and directed.
Supply & fixing in repairs gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe of 40mm bore including taking down existing one complete all as specified and directed.
Supply & fixing in repairs gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe of 50mm bore including taking down existing one complete all as specified and directed.
Taking out the unserviceable cast iron sluice valve for size 80 mm bore and S&F new CI sluice valves PN 1.6 confirming to ISI with flanged ends, both end drilling, with SS spindle, round wheel including jointing materials, nuts, bolts and gasket complete all as specified and directed.
Taking out the unserviceable cast iron sluice valve for size 100 mm bore and S&F new CI sluice valves PN 1.6 confirming to ISI with flanged ends, both end drilling, with SS spindle, round wheel including jointing materials, nuts, bolts and gasket complete all as specified and directed.
Taking out the unserviceable cast iron sluice valve for size 150 mm bore and S&F new CI sluice valves PN 1.6 confirming to ISI with flanged ends, both end drilling, with SS spindle, round wheel including jointing materials, nuts, bolts and gasket complete all as specified and directed.
Material & Labour for CI/DI spigot/flanged fittings for spigot/flanged end pipes and for header purpose such as bends any type, radius and angle) tapers any type (straight, bend increasing or decreasing double socket flanged etc), Tee pieces, single branch, 'Y' junction, double branch cross (all socket or socket and spigot or flanged, Collars, caps and plug etc all as specified and directed up to 250mm bore.
Material & labour for 250mm MS pipe Header of 10mm wall thickness with length not less than 6 Meter including 9 nos inlet/outlet pipe with flanges of 100mm/150mm dia for provsion of inlet and outlet connection including PCC foundation complete all as specified and directed. Note: The quoted rate deem to includes welding of flanges to header, fabrication and other miscellaneous connected works.
M&L Providing, cement concrete in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates etc water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
M & L for cutting of road, hard standing made of concrete or premix carpet, WBM, soiling and morrum filling including excavation for laying of cable/water pipe line all as directed and making good the road/hard standing by using all old/new materials and with PCC (1:2:4) etc, required to match with the existing surface complete all as specified and directed.
MCS ENGINEERING CONSTRUCTIONS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .