Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.3 LAccepted-Finance 45 58 5 15A AKSHAYA NARASIMHANAGAR VISAKHAPATNAM 530 024 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530024 | L1 | Accepted-Finance Admitted being the lowest | |
| 2 | L2₹20.1 L+₹83,315 (4.32%)Rejected-Finance | L2 | Rejected-Finance L1 Being the lowest. | |
| 3 | L3₹22.2 L+₹2.9 L (14.9%)Rejected-Finance HARINAGAR BEHIND MAHESHWARY MARKET PO TATISILWAI DIST RANCHI PIN 835103 | RANCHI | JHARKHAND | 835103 | L3 | Rejected-Finance L1 Being the lowest. | |
| 4 | L4₹22.5 L+₹3.2 L (16.7%)Rejected-Finance D NO 5 13 24 1 BEHIND SAHUWALA CYLINDERS IDA AUTONAGAR VISAKHAPATNAM 530 012 | VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530012 | L4 | Rejected-Finance L1 Being the lowest. |
Tender Value
₹18.5 L
EMD Value
₹37,000
Closing Date
29 Nov 2023, 6:00 pmClosed
Garrison Engineer (I)(CG) Chennai
Garrison Engineer (I) (CG) Military Engineer ServiceCGRA Meenambakkam Building No P 16 NGO Colony 4th Street Nanganallur Chennai 600 061
Repairs and routine maintenance of Electrical lifts installed at CGRA Phase-II, Meenambakkam Area under GE(I)(CG) chennai
2023_MES_628429_1
8080/E8/GE(I)CGCHENNAI
Open Tender
Miscellaneous Works
Item Rate
270 days
Garrison Engineer (I)(CG) Chennai
All as per tender documents
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer (I)(CG) Chennai
₹37,000
Yes
11 Dec 2023
15 Nov 2023
1 Dec 2023
15 Nov 2023
29 Nov 2023
17 Nov 2023
Amount
SCHEDULE 'A' - PART I (MAINTENANCE)
Comprehensive maintenance and repairs to electrically operated lifts of IES make at CGRA (Phase-II) thalakancherry including renewal/replacement of defective parts of Automatic Rescue Device and Over Load Warning Device with a capacity of 08 no passengers lift , 544 Kg each -10 Nos, 1.0 meter/sec , single speed single push button control system with micro processor control system collective control scheduled in Appx "A" by carrying out periodical checks/ repair and testing as per Appx "B" as recommended by the manufacturer and as directed by Engineer in charge to ensure smooth functioning and efficient operation including fixing only for the items mentioned below in Schedule A Part II .
Comprehensive maintenance and repairs to electrically operated lifts of IES make at CGRA (Phase-II) thalakancherry including renewal/replacement of defective parts of Automatic Rescue Device and Over Load Warning Device with a capacity of 13 no passengers lift , 884 Kg each -10 Nos, 1.0 meter/sec , single speed single push button control system with micro processor control system collective control scheduled in Appx "A" by carrying out periodical checks/ repair and testing as per Appx "B" as recommended by the manufacturer and as directed by Engineer in charge to ensure smooth functioning and efficient operation including fixing only for the items mentioned below in Schedule A Part II .
Note for item No 2 to 3 (i) The spares/electrical items as listed in Sch 'A' will be used whenever required only and measured and paid separately under respective items. (ii) The rate is inclusive of all items as required at site except those items as given in supply only to keep the lift operational round the clock including cleaning and greasing all moving parts on monthly basis complete all as specified and as directed by Engineer-in-Charge. (iii) If spare parts of original make is not available in market necessary suitable spare equivalent to existing lift part as approved by GE shall be used in the work so that to run the lift with smooth functioning. (iv) Cost of renewal of lift license is deemed to be included in the quoted rate .
(v) Quoted rate incl the testing of all the lifts by licensed Lift Inspector of tamil nadu twice in contract period for saftey.Certificate issued by the licensed lift inspector shall be submitted to Eng-in-charge. (vi) In case of any of the lift/lifts is/are not working for more than 24 hours but less than 10 days, Recovery will be affected at the rate of Rs 2,000/- per lift per day and Rs 3,000/- per lift per day after 10 days. (vii) The above lifts shall be repaired through OEM (Original Equipment manufacturer) or through their nearest authorised/accredited agency service personel only.The lowest bidder shall submit and uploading MoU from the OEM of lift or their authorised/accredited agency at time of uploading of tender. (viii) Contractor should submit all valid docucments before the opneing of tehcnicial bid.
SCHEDULE 'A' - PART II ( SPARE PARTS)
Main controller transformer primary 415v AC secondary - 24/110/130/230/270v AC. Make :SSPM
Floor oscillator relay optical type working on 12 / 24 VDC.
Main contactor with coil, 60 Amp, Power contactor with 2 NO + 2NC aux. Contacts and with 230 V AC/DC Coil . Make : C&S, ABB.
Power contractor 32 Amps with 24/48 V AC / DC coil. Power contactor, 32 Amps with 02 No + 2 NC. Aux contacts with 230 V AC/110VDC complete all as directed. Make : C&S, ABB.
Digital lift cabin position indicator 1 digit vertical one segment card. Make IES
Lift cabin coaxial fan 300 mm 1000 RPM.
Nylon roller for lift car door and landing door 35*40 mm. Make IES
BCD to 7 segment card programable type for lift control panel. Make IES
COP digital position indicator with FL/OL card for lift cabin. Make IES
ARD 12 relay card. Make : IES
Lift cabin / Landing illuminated push button working on 24VDC. Make : IES
Six relay card for lift control panel. Make : IES
Two relay card for lift control panel. Make : IES
Three changeover relay 24V DC. Make : PLA
Two changeover relay 24V DC. Make : PLA
Trailing cable 10 core x 0.75 Sqmm . Make Microtherm.
Microprocessor MicroLogix 1200 1762L40BWA. Make : Allen Bradely
Input module 24 Volts DC l/P or Potential free relay O/P contact to match with MicroLogix 1200. Make : Allen Bradely
Full length Infrared sensor 64 beams for car door including transmitter, receiver and control unit
Charger card of automatic rescue device 230 Volts input / 72 Volts output . Make Jeltron /IES.
Microprocessor card of automatic rescue device Make Jeltron /IES.
Converter card of automatic rescue device to convert 72 Volts DC input to 24 Volts DC output Make Jeltron /IES.
MOSFET card of automatic rescue device to covert 72VDC to 230 Volts AC 3 Amps. Make :Jeltron / IES
Rotary encoder for speed feedback of main drive
Door motor and suitable VVVF drive for car door operation. Make : Monarch
VVVF drive for 7.5KW lift motor or 5.5KW including feeding all parameters and interfacing with controller micro processor and drive including setting of basic parameters to obtain the desired and designed value of various motions of the lift Make : Toshiba / Square-D / AB / GEFRAN
Car Door Operator for 800 mm Centre Opening Door along with bottom Aluminum Cill, Stainless Steel Door Panel with Vision Panel of size 200 X 800 mm with 8 mm Toughened Glass complete made out of AISI 304 Grade Stainless Steel Sheet of 1.5mm thick, Car Door Motor with Built-in Rotary Encoder, VVVF Drive for Car Door operation, Full Length / Infra Red Sensor, 64 Beams for Car Door including Transmitter, Receiver and Control Unit working on 230 Volts, AC Make : IES
Landing Door Mechanism of 800 mm Centre Opening Door along with Bottom Aluminum sill Make : IES
Maintenance free sealed battery 12V 7AH. Make : Exide/ Amaron/Amco
Lift landing door rope for 800mm center opening door mechanism. Make : IES.
car door operator belt for 800mm center opening door mechanism. Make : IES.
SCHEDULE 'A' - PART III
Taking down main motor 3 pohase 380 Volts, up to 09 KW, 1300/325 RPM and material and labour for rewinding the same using suitable gauge of copper winding wire and all insulation item including varnishing drying and refixing of AME at site testing and incluing replacement , if necessary for nuts and bolts for foundation etc complete all as directed.
Taking down main motor 3 pohase 380 Volts, up to 15 KW, 1300/325 RPM and material and labour for rewinding the same using suitable gauge of copper winding wire and all insulation item including varnishing drying and refixing of AME at site testing and incluing replacement , if necessary for nuts and bolts for foundation etc complete all as directed.
Taking down cabin fan single phase, 230Volts and material and labour for rewindingthe same using suitable gauge of copper winding wire and insulation varnishing, drying and refixing of fanin lift cabin and testing all as directed.
Rewinding of break coil including opening and cutting old brunt out winding and rewinding with copper coil of existing gauge and applying insulating varnsih, drying
SATYAM ENGINEERS
UNIVERSAL ENTERPRISES
INDUSTRIAL ENGINEERING SYSTEMS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .