GE CENTRAL KIRKEE
GE CENTRAL KIRKEE RANGE HILLS ROAD KIRKEE PUNE 411003
WELCOME MAINT TO INT ELECT AT SARVATRA VIHAR ENGINE HOUSE ROAD 512 MD ACCN ME LINE AND MAINT REP RENE OF LT OH LINES AND LT DISTRIB SYS INCL REPLACE OF UG CABLES SWITCH GEARS AND OTHER LT ACCY ETC AT CENTRAL AREA UNDER AGE EM II IN GE C KKE
2021_MES_421750_1
8449/E8 OF 2020-2021
Open Tender
Civil Works
Item Rate
270 days
KIRKEE
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹81,160
Yes
6 Apr 2021
12 Feb 2021
13 Mar 2021
12 Feb 2021
12 Mar 2021
27 Feb 2021
12 Feb 2021 - 26 Feb 2021
60 days
Amount
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying of pipe and getting out in Soft soil.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying of pipe and getting out in Hard/Dense soil.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying of pipe and getting out in Soft disintegrated rock
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick.
Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point.
PCC (1:3:6) type C-2 using 40mm graded aggregate as in foundation for filling in, mass concrete for foundation of Pole, Transformer, Panel board, stay, post top lantern, repairs to road cutting, drain, path etc complete all as specified and directed.
PCC (1:2:4) type B-1 using 20mm graded aggregate as in coping of new pole / reconstruction old damaged copings etc, including necessary form work complete all as specified and directed
M&L for sand for cousioning of UG cable/ at cable trenches inside substation bulding
M&L for brick protection with sub class 'B' brick for UG cable
M&L for brick protection with old retrived brick/PCC cable cover during excuvation for UG cable
Dismentling taking out carefully old/unserviceable UG cable any type any size from trenches/poles/ducts/LT panels after dismentling ends from OH conductors/MCCBs/joint boxes for relaying/refixing or carrying to store for Sch of Credit.
Materisl and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wal or fixed to LT panel board, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 6 sqmm 2 core with required aluminium cable lugs, heat shrink joints, Colour code heat shrink sleeves at both cable ends all as specified and directed. Note: (i) Heat shrink joint 2 core/4 core shall be measured and paid under appropriate item of this Sch as supply only. (ii) Serviceable GI tubing obtained from item No-8 here-in-before for cable protection shall be refixed/relaid, No extra measurement shall be made. (iii) GI tubing required new shall be measured and paid separately as supply only, (iv) Heat shrink sleeve of 25mm long on HS joint for colour indication shall deemed to be included on the quoted rate.make of cable Polycab/Gloster/Finolex or eqvt.
All as per item No. 12 here-in-before but 10sqmm 2 core complete all as specified
All as per item No. 12 here-in-before but 16sqmm 4 core complete all as specified
All as per item No. 12 here-in-before but 25sqmm 3.5 core complete all as specified
All as per item No. 12 here-in-before but 35sqmm 3.5 core complete all as specified
All as per item No. 12 here-in-before but 50sqmm 3.5 core complete all as specified
All as per item No. 12 here-in-before but 95sqmm 3.5 core complete all as specified
All as per item No. 12 here-in-before but 120sqmm 3.5 core complete all as specified
All as per item No. 12 here-in-before but 300 sqmm 3.5 core complete all as specified
Dismentling taking out broken/worn out steel pole of 8.5 to 9.0 mtr long and kepping aside for refixing or carrying to store for credit
Only Labour for fixing steel tubular poles (serviceable length not less than 7.5 mtr) obtained from item No 25 here in before with necessary cutting/welding at broken/worn out potion painted inclusive of one coat of aluminium paint to external surface of pole, transportation to new place and fixed in position as stud pole or for independent street light fitting all as specified and directed
M&L for steel tubular swaged pole complete with cast iron base plate , finial taper plug bolts nuts and screws confirming to IS : 2713 and made out of structural steel tube confirming to IS: 1161 and painted internally with a coat of bituminous paint and externally one primer coat, one under coat and one finishing coat of aluminium paint as specified type 410 SP-31 (9 mtr long).Make -sing profile or eqvt.
Dimentling and taking down old/unsv cross arms, bracing, supports etc complete for reuse at site or carrying to store for sch of credit all as specified and directed.
Only Labour for Fixing cross arms bracings supports clamps and back plates fabricated from steel sections including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one coat of aluminium paints complte all as specified and directed obtained from item Ser No- 28 here-in-before, (Note- to be measured only when found serviceable in all respect complete for reuse)
M & L for cross arms bracings supports clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paints complte all as specified and directed.
Dismetling and taking down old/unsv ACSR conductor any size complete for reuse at site or carrying to store for Sch of Credit all as specified and directed
Only Labour for fixing ACSR conductor any size obtained from item No-27 incl jointing with existing conductor and straining on LT pole and proper fastening to pin/shackle insulators with aluminium binding wires and required jumpering connection all as specified and directed. (Note- to be measured only when found serviceable in all respect complete for reuse)make-
M & L for ACSR conductor incl jointing with existing conductor and straining on LT pole and proper fastening to pin/shackle insulators with aluminium binding wires and required jumpering connection all as dircted
Dimentling and taking down old/unsv insulator of any type any size from pole/stay for reuse at site or carrying to store for sch of credit complete all as specified and directed.
Labour for Fixing insulator pin/shackle any type porcelain vitreous 1100 volts grade including galvanised mild steel spindle/straps, GI nuts, bolts and washer obtained from item No:-36 here-in-before. (Note- to be measured only when found serviceable in all respect complete for reuse) all as specified and directed.
M & L for pin type, porcelain, vitreous, brown, including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, 100mm height and 65 mm dia for 1100 volts grade all as specified and directed..
M & L for shackle type,porcelian vitreous white, brown or green insulator including galvanised mild steel straps , washers, insulators bolts ,washer and nuts of size 100 mm height and 115 mm dia for 1100 Volts grade complete all as specified and directed.
M & L for Loop type insulator, porcelian vitreous brown of size 65x90mm and clearence hole 16mm all as specified and directed.
M & L for for Stay assy using 16mm dia galvanised rod complete all as shown in electrical plate No 1 of SSR Part I incl dismentling unsv one all as specified and directed. (Clamps, loop insulator, earth work, PCC measured separately)
M & L for stay wire using galvanised steel strand of 7/3.15mm complete with necessary binding incl dismentling taking down unserviceable one all as specified and directed
M & L for cradle hexagonal /rectangular fabricated with galvanised steel wire not less than 4mm dia on pole incl dismentling taking out unsv cradle guard
M & L for earth continuity wire using GI wire not less than 4mm dia on pole incl dismentling taking out unsv GI wire
M & L for Earthing complete with galvanised steel earth plate electrode 6mm thick of size 600x600 mm buried directly and vertically in ground with top edge of the plate not less than 2.25 mtr from GL, connected with galvanised steel earthing lead of 4mm dia all as shown in Plate No-3, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2with RCC precast pit cover slab 400mmx400mmx80mm with handle for lifting made out of 8mm dia MS rod, funnel, wiremesh, 15 mm dia light grade GI tubing for protection of GI wire 4mm dia, charcoal and salt in alternate 150mm thick layers around GI earth plate, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion
M&L for restraining of overhead ACSR conductor of any size of 4 wire on pole after disconnecting all jumpering connection & binding of insulators and redoing all jumpering connection and insulator binding with aluminium conductor providing required T&P all as specified and directed .
M&L for restraining of ACSR conductor of any size of 2 wire on pole after disconnecting all jumpering connection & binding of insulators and redoing all jumpering connection and insulator binding with aluminium conductor providing required T&P all as specified and directed
M&L for restraining of GI Cradle guard hexagonal/rectangular of any size on pole after disconnecting all binding on cross arms and redoing all bindings providing required T&P all as specified and directed
M&L for restraining of GI earth wire of any size on pole after disconnecting all binding on cross arms and redoing all bindings providing required T&P all as specified and directed
M & L for Heat shrink joint (end joint)indoor/outdoor LT 1100 volts grade 10-16 sqmm, 4 core, make-Raychem/M seal /3M
M & L for Heat shrink joint (end joint)indoor/outdoor LT 1100 volts grade 25-50 sqmm, 4 core,
M & L for Heat shrink joint (end joint) indoor/outdoor LT 1100 volts grade 70-120 sqmm, 4 core,
M & L for Heat shrink joint (end joint)indoor/outdoor LT 1100 volts grade 150-185 sqmm, 4 core,
M & L for Heat shrink straight through joint LT 1100 volts grade 10-16 sqmm, 4 core,
M & L for Heat shrink straight through joint LT 1100 volts grade 25-50 sqmm, 4 core
M & L for Heat shrink straight through joint LT 1100 volts grade 70-150 sqmm, 4 core,
M & L for Heat shrink straight through joint LT 1100 volts grade 185-225 sqmm, 4 core,
M & L for Heat shrink straight through joint LT 1100 volts grade 240-300 sqmm, 4 core,
M & L for aluminium cable lugs of size 50 sqmm flat head in Aluminium conductor fixing with Nuts, bolts & washers to junction point as directed, (Note-To be measured only, fixed at places with heat shrink joints)
M & L for aluminium cable lugs suitable for XLPE cable size 70 sqmm
M & L for aluminium cable lugs suitable for XLPE cable size 95 sqmm
M & L for aluminium cable lugs suitable for XLPE cable size 120
M & L for aluminium cable lugs suitable for XLPE cable size 150
M & L for aluminium cable lugs suitable for XLPE cable size 240
M & L for aluminium cable lugs suitable for XLPE cable size 300 sqmm
M & L for MCCB, 4 pole, 36 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 400 amps, incl dismentling taking down unsv one, make- Legrand /Schneider/Havells.
M & L for MCCB, 4 pole, 36 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 200 amps, incl dismentling taking down unsv one,make- Legrand /Schneider/Havells.
M & L for MCCB, 4 pole, 36 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 125 amps, incl dismentling taking down unsv one,make- Legrand /Schneider/Havells.
M & L for MCCB, 3 pole, 25 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 200 amps, incl dismentling taking down unsv one,make- Legrand /Schneider/Havells.
M & L for MCCB, 3 pole, 25 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 160 amps, incl dismentling taking down unsv one,make- Legrand /Schneider/Havells.
M & L for MCCB, 3 pole, 25 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 125 amps, incl dismentling taking down unsv one make- Legrand /Schneider/Havells. ,
M & L for MCCB, 3 pole, 25 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 100 amps, incl dismentling taking down unsv one,make- Legrand /Schneider/Havells.
M & L for MCCB, 3 pole, 25 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 63 amps, incl dismentling taking down unsv one,make- Legrand /Schneider/Havells.
M & L for MCCB, 3 pole, 25 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 40 amps, incl dismentling taking down unsv one,make- Legrand /Schneider/Havells.
M & L for surface mounting time switches, daily dial, , incl dismentling taking down unsv one,
M & L for 3 pole power contactor, 415Volts, 40 amps, , incl dismentling taking down unsv one,make- L &T /Schneider/ABB.
M & L for GI tubing light grade 40mm bore, ISI marked, for cable protection
M & L for GI tubing light grade 50mm bore, ISI marked, for cable protection
M & L for only GI tubing light grade 80mm bore, ISI marked, for cable protection
M & L for 1100 volts grade heavy duty flat twin core cable PVC insulated with stranded aluminium conductor of size 10 sqmm and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension GI wire from OH conductor to building incl dismentling taking down unserviceable one all as specified and directed.
M & L for replacing Electronic drivers for LED Lights suitable for 15 ,30,45 watt make crompton/ Wipro/Philips or equivalent
M & L for replacing search protectors for LED Lights suitable for 15 ,30,45 watt make crompton /Wipro/Philips or equivalent
M&L for painting of steel tubular/rail/chanel/joist pole with one coat of alumium paint incl cross arm, bracings, supports, nuts, bolts, of LT OH line from above copping to top of pole.
Dismentling taking down carefully street light fitting any type any size from for repair or replacement or for fixing in other position all as directed.
M & L for PVC insulated, PVC sheathed twin flat core 1100 volts grade, 2.5 sqmm aluminium stranded conductor fron OH conductor or from junction box to street/security/post top luminaries all as directed.
M & L for LED post top lantern 20 watt in repair made of pure polyster UV resistant powder coated die cast aluminium housing, integral, make wipro/Philips/Bajaj or equivalent.
M & L for LED fantacy Bollard light in repair made of extruded aluminium housing of 11 watt ,230 Vplt AC make Wipro/Bajaj/ Philips or equivalent .
M & L for street light bracket, made out of 40 mm dia GI pipe, (medium grade) 0.8 metre long bend to shape as required and welded and fixing in position incl dismentling taking down unsv complete all as specified and directed. (Note:MS Clamp, nuts, bolts & washers measured separately)
M & L for street light bracket, made out of 25 mm dia GI pipe, (medium grade) 0.8 metre long bend to shape as required and welded and fixing in position incl dismentling taking down unsv complete all as specified and directed. (Note:MS Clamp, nuts, bolts & washers measured separately)
M & L for GI tubing 40mm bore medium grade, cut to pieces 1.2 mtr long for mounting of post top lantern independently at places or at top of gate/pillar and grouting in PCC incl dismentling taking down unsv complete all as specified and directed. (Note: PCC, earthwork whereever required will be measured and paid separately)
M & L for sheet steel enclosure of size 40cmx30cmx40cm made out of 3mm thick MS sheet hinged door and locking arrangements and painting (inside and outside) with epoxy powder coated including fixing in position with the following accessories internally pre wired and testing complete all as directed. (a) Time switch, MaxiRex 4QT-daily, 240V, AC, base mounting, Legrand 6499-15 – 01 No. (b) 3 pole power contactors, type ML-3 of L&T or equivalent – 01 No. (c) Toggle switch, single pole 2 way - 01 No. (d) bakelite base brass terminal connector block 8 way 40 amps cap-1 No, (e) MCB TP 40 amps of Legrand/L&T-1No and fixed to pole/wall with clamp, nuts, bolts washers and testing complete incl dismentling taking down unserviceable switch fuse complete all as specified and directed. (Note:MS Clamp, nuts, bolts & washers measured separately)
M/L for trimming of branches of trees touching LT electric over head line and making clear about 3 mtr in radius by climbing up tree or by providing ladder, at a height 7 mtr and above and carrying and depositing where directed not exceeding 50 mtr.
M & L for rigid PVC line spacer, U-shaped, spriral type, suitable for 2 wire, made from high grade PVC material, distance bet phase to phase 300mm, suitable for use with 1100 volts grade. Make- Shree Balaji Power Plast/Goyal Power Plast
M & L for rigid PVC line spacer, U-shaped, spriral type, suitable for 4 wire, made from high grade PVC material, distance bet phase to phase 300mm, suitable for use with 1100 volts grade. Make- Shree Balaji Power Plast/Goyal Power Plast
M&L for Checking/megering of UG cable fault of any size/core and taking out the damaged portion of cable from trenches and removing the fault portion of cable and checking, jointing the same with proper cable end jointing kit and testing for smooth functioning of complete cable and re-laying the same after testing of following size .Note: (i) Excavation/earth work/returning filling/relaying of brick and sand cushioning deemed to including the job. (ii) Extra cable will be measured and paid under relevant item. iii) Joint kit required will be measured and paid separately under relevant item.
All as per item No. 87 here-in-before but 10 sq mm to 16 Sq mm, 2 core complete all as specified
All as per item No. 87 here-in-before but 16 sq mm to 25 Sq mm, 4 core complete all as specified
All as per item No. 87 here-in-before but 35 to 95 Sq mm, 3.5 core complete all as specified
All as per item No. 87 here-in-before but 120 to 150 Sq mm, 3.5 core complete all as specified
All as per item No. 87 here-in-before but 185 to 300 Sq mm, 3.5 core complete all as specified
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one light point or one fan point or one call bell point controlled by one, one way switch including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, regulators or bell push and casing caping terminal box for mounting ceiling rose/ holders etc incl dismentling taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one 5 amps socket point independent including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, socket incl dismentling taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one 5 amps socket point on same board with other switches incl dismentling taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one two way light point controlled by two, two way switch including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch etc incl dismentling taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm as earth lead and connected to earth dolly for one 16amps socket (Power) point independent including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, socket all as specified and directed.
M & L for surface submain wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a) Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
M & L for surface submain wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 4.0 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 4 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a) Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
M & L for surface sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a)Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
M & L for surface sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FR Copper conductor cable of size 10.0 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FR Copper conductor cable of size 10.0 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a)Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
M & L for surface sub main wiring with four single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSHCopper conductor cable of size 10.0 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith two single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 10.0 sqmm as earth leads and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a)Four run of cable with two run of earth wire and one run of casing capping/conduit will be measured as one length.
S&F 5 Amp switch piano type single pole one way incl dismentling taking down unsv one all as specified and as directed. Make - Anchor ( penta )or equivalent
S&F 5 Amp switch piano type two way incl dismentling taking down unsv one all as specified and as directed. Make - Anchor ( penta ) or equivalent
S&F bell push piano type one way 240 volt incl dismentling taking down unsv one . all as specified and as directed. Make - Anchor ( Penta ) or equivalent
S&F socket flush type 6 amps, 5 pin, 230v incl dismentling taking down unsv one all as specified and as directed. Make - Anchor ( Penta )or equivalent
S&F switch socket combination multipurpose 2-in-1 flush type 3 pin 6 amps, 230v incl dismentling taking down unsv one all as specified and as directed. Make - Anchor ( Penta )or equivalent
S&F switch socket combination multipurpose 2-in-1 flush type 3 pin 16 amps and 3 pin 6 amps, 230v incl dismentling taking down unsv one all as specified and as directed. Make - Anchor ( Penta ) or equivalent
S&F lamp Holder insulated body with back plate for batten fitting incl dismentling taking down unsv one all as specified and as directed. Make - Anchor ( Penta ) or equivalent
M&L LED lamp 12 watt, CDL, B-22 cap, (Pin type), 230V, PF-0.95 (min) incl dismentling taking out unsv CFL. Make-HPL/Havells/CG/Bajaj/ Philips
S&F ceiling rose surface Bakelite three terminal incl dismentling taking down unsv one all as specified and as directed. Make - Anchor or equivalent
S&F call bell electric, ding dong, AC 240 volt, 50 HZ. incl dismentling taking down unsv one all as specified and as directed. Make - Anchor or equivalent
S&F flush type electronic fan regulator with 5 step type,100 W, AC 240 Volts, 50 Hz incl dismentling taking down unsv one all as specified and as directed. Make - Anchor or equivalent
S&F MCB, Single Pole, 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve incl dismentling taking down unsv one all as specified and directed. MAKE Legrand or equivalent of Schneider/ABB.
S&F MCB, Double Pole, 6 to 32 amps, 415 Volts, 10 KA breaking cap, ‘’C” curve incl dismentling taking down unsv one all as specified and directed. MAKE- Legrand or equivalent of Schneider/ABB
S&F MCB, Four Pole, 40 to 63 amps, 415 Volts incl dismentling taking down unsv one all as specified and directed. MAKE- Legrand or equivalent of Schneider/ABB
S&F Sheet metal enclosure two way, incl dismentling taking down unsv one all as specified and directed. MAKE- Legrand or equivalent of Schneider/ABB.
S&F MCB distribution board,Double door, metal enclosure, SPN, 230 Volts, 4 way incl dismentling taking down unsv one all as specified and directed. MAKE- Legrand or equivalent of Schneider/ABB
S&F MCB distribution board, Double door, metal enclosure, SPN, 230 Volts, 8 way incl dismentling taking down unsv one all as specified and directed. MAKE- Legrand or equivalent of Schneider/ABB
S&F MCB distribution board, Double door, metal enclosure, SPN, 230 Volts,12 way incl dismentling taking down unsv one all as specified and directed. MAKE- Legrand equivalent of Schneider/ABB
S&F MCB distribution board, Double door, metal enclosure, TPN, 415 Volts, 4 way incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 5076-70 of Legrand or equivalent of Schneider/ABB
S&F Vertical MCB distribution board, as MCB incomer, Double door, metal enclosure, TPN, 415 Volts, 4 way incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 5077-25 of Legrand or equivalent of Schneider/ABB
S&F Vertical MCB distribution board, as MCCB incomer, IP 43 protection, Double door, metal enclosure, TPN, 415 Volts, 4 way incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No-507745 of Legrand or equivalent of Schneider/ABB
S&F Metal plug and socket board with MCB SP 20 amp, 16 KA incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 5078 11 of Legrand or equivalent of Schneider/ABB
S&F PVC rectangular switch board of size 300mmx 250mm x50mm incl necessary cutting slots for mounting switch sockets etc incl dismentling taking down unsv one all as specified and directed. MAKE- Presto Teak/Press Fit/Plaza.
S&F PVC rectangular switch board of size 200mmx 150mm x50mm incl necessary cutting slots for mounting switch sockets etc incl dismentling taking down unsv one all as specified and directed. MAKE- Presto Teak/Press Fit/Plaza.
S&F PVC rectangular switch board of size 175mmx 100mm x50mm incl necessary cutting slots for mounting switch sockets etc incl dismentling taking down unsv one all as specified and directed. MAKE- Presto Teak/Press Fit/Plaza.
S&F PVC rectangular switch board of size 100mmx 100mm x50mm incl necessary cutting slots for mounting switch sockets etc incl dismentling taking down unsv one all as specified and directed. MAKE- Presto Teak/Press Fit/Plaza.
S&F Hylam Sheet 3mm thick on existing concealled MS/CI ractangular or Squar or round box with 04 nos cadmium coated screws and cup washer incl cutting slots for mounting switch/socket/fan regulator/ batten holder etc incl dismentling taking down unsv one
S&F Round shaped surface/ recess mounted LED Flat panel,PDC Aluminium housing and PMMA difuser 12 watt suitable for surface/ POP celing complete with all fixing accessories and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable incl dismentling taking down unsv fitting any type all as specified and directed. Make-crompton cat part no.LCDSPLN-R-12-CDL or equivalent in Bajaj/Philips/HPL/Havells
S&F square shaped surface/ recess mounted LED Flat panel,PDC Aluminium housing and PMMA difuser 36 watt suitable for surface/ POP celing complete with all fixing accessories and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable incl dismentling taking down unsv fitting any type all as specified and directed. Make-crompton cat part no.LCPL-36-CDL (2X2) or equivalent in Bajaj/Philips/HPL/Havells
M&L LED batten tube type, 2'long, 09 watt,CDL 230 Volts , complete with all accssories internally pre wired and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable with mounting casing box 2 nos incl dismentling taking down unsv fitting any type all as specified and directed. Make-HPL Cat Part No- HLPT51509PCGCW or equivalemt in Bajaj/Philips/CG/Havells
M&L LED Tube light fitting, 20 watt, CDL, integrated LED batten, 230 Volts, 4 feet long , complete with all accssories internally pre wired and including connecting up to ceiling rose with 0.5 sqmm twin core copper flexible conductor cable incl LED lamp and mounting casing box 2 nos incl dismentling taking down unsv fitting any type all as specified and directed. Make-Shakti CP NO SZSLAMX020 or equivalemt in Bajaj/Philips/ HPL /Havells
M&L LED Tube light fitting, 18 watt, CDL, durable LED batten with decorative end caps, 230 Volts, 4 feet long , complete with all accssories internally pre wired and including connecting up to ceiling rose with 0.5 sqmm twin core copper flexible conductor cable incl LED lamp and mounting casing box 2 nos incl dismentling taking down unsv fitting any type all as specified and directed. Make-crompton model trim linea, Cat Part No.LCTL-18-CDL or equivalemt in Bajaj/Philips/ HPL /Havells
M&L LED building security light 25 watt, 230V complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade 25/32 mm dia bracket of total length 60 cm and fixed to wall with 2 Nos MS Clamp and fastener incl dismentling taking down unsv fitting any type all as specified and directed. Make-CG, Cat Part No LSTS-25-CDL model ASTRA or equivalent in Bajaj/Philips/HPL/Havells
REPAIR TO CEILING FANS WITH FOLLOWING ITEMS OF WORK :- M&L for Rewinding of Ceiling fan 1200 mm sweep after dismenting complete motor assy, bearings, bushings, removal of burnt copper wire, cleaning of core, inserting proper insulating paper in slots, winding with and as per existing size/turn of super enamelled copper wire, heating, vernishing, replacement of unsv bearings / bushings, assemble of rotor and stator unit with capacitor, connecting wire, down rod, blades and testing complete. Note: 1. Contractor will collect fans from the complaint cells of specified area and bring back to complaint cell after repair. Cost of transportation will be inclusive of quoted rate. 2. Spares require for replacement such as bearing, Bushing, capacitor shall be measured and paid separately as supply & Fixing only. 3. Cost of Connector bock and capacitor holder shall be inclusive of the quoted rate.
All as per item No- 44 here-in-above but for Exhaust fan 250/300 mm sweep industrial type.
S&F ball bearing No 6201/6202/6203/6204 of SKF/Tata/NBC.
S&F G.M. Bush bearing for ceiling fan as per existing pattern.
S&F capacitor AC for 230 volts 50 Hz of capacity 1.8 Mfd.
S&F capacitor AC for 230 volts 50 Hz of capacity 2.0/2.25/2.5 Mfd.
S&F capacitor AC for 230 volts 50 Hz of capacity 3.15 Mfd.
S&F capacitor AC for 230 volts 50 Hz of capacity 4.0 Mfd.
Painting of ceiling fan 1200/1400 mm including scrapping, cleaning and removing dust from the blade an body and applying two coat of enamel paint over & one coat of primer all as directed by engr-in-chage
S& F in repair of exhaust fan 225/300 mm PVC body with louvres, 230 volt incl dismentling taking down unsv fan any type all as specified and directed. Make Bajaj/usha/crompton.
S& F in repair of exhaust fan 300 mm metal body, 230 vol incl dismentling taking down unsv fitting any type all as specified and directed. Make Bajaj or equivalent
S&F PVC insulated PVC sheathed copper flexiable wire multistrand 4sqmm 3 core, ISI marked
S&F in repair thermostat ISI marked suitable for geysers 25 Ltrs to 50 Ltrs Capacity. Make- Bajaj/Venus/Recold all as specified and directed.
S&F in repair fusible plug marked suitable for 25 and 50 ltrs capacity Geysers all as specified and directed.
S&F in repair heating elementMarked round/triangular bas, push type or thread type including rubber washers for 1.5/2.0 KW all as specified and directed.
S&F in repair innner water container made of SS, vertical or horizontal type for 25/50 ltr capacity gyser all as specified and directed.
S&F in repair of aparatus plate suitable for vertical/horizintal type Geyser 25 or 50 ltr cap all as specified and directed.
S&F in repair heavy duty copper connections pipe with brass hexagonal adopters at both side 15mm dia and 450mm long for hot water all as specified and directed.
S&F in repair heavy duty PVC connections pipe with brass hexagonal adoptersat both side 15mm dia and 450mm long for hot /cold water all as specified and directed.
M & L for Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 6 mtr long buried directly and vertically in ground with top edge at ground level after making bore hole of size not less than 300 mm dia and 6.0 Mtr long using suitable mechanical drilling rig (for drilling near the specified location), connected with galvanised earthing lead of 4 mm dia all as shown in Plate No-2, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2with pit cover, funnel, wiremesh, 15 mm dia light grade GI tubing for protection of GI earthing lead 4mm, charcoal and salt in alternate 150mm thick layers around GI earth pipe, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion.
Mahindra Electric Stores
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .