Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹12.8 L+₹1.5 L (12.8%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹14.0 L+₹2.7 L (24.0%)Rejected-Finance CHANDPURA TIKAMGARH DIST TIKAMGARH MP | TIKAMGARH | TIKAMGARH | MADHYA PRADESH | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹14.3 L+₹3.0 L (26.6%)Rejected-Finance GROUND FLOOR TRACTOR MARKET KAITHAL ROAD ASSANDH KARNAL HARYANA 132039 | KARNAL | HARYANA | 132039 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹15.8 L+₹4.5 L (39.7%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹22.5 L
EMD Value
₹45,000
Closing Date
30 Jan 2020, 6:00 pmClosed
GE (AF) BHISIANA
Garrison Engineer (AF), Military Engineer Services, Bhisiana, PIN-151201
Repair and Maint External Elect Supply, External Water Supply and DG Sets alongwith connected Works 44 WEU (Abohar) under GE (AF) Bhisiana
2020_MES_311183_1
GE/BHI-57/2019-20
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) BHISIANA
Please refer Tender Documents
8 documents required · 8 mandatory
₹500
GE (AF) BHISIANA
₹45,000
Yes
4 Jun 2020
2 Jan 2020
31 Jan 2020
2 Jan 2020
30 Jan 2020
16 Jan 2020
Amount
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in deep for foundation of poles/stays/cables/Pipe lines etc and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in including spreading, leveling, watering and well ramming in layers each not exceeding 25 cm thickness complete all as specified and as directed by Engineer-in-Charge.
Removing surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed by Engineer-in-Charge.
Taking out /down old unserviceable CI pipe of 100/80 mm dia including all fittings etc from trenches complete all as specified and directed by Engineer-in-Charge (Note : Earth work shall be measured and paid seperately )
Taking out /down old unserviceable GI pipe of 40/50 mm dia including all fittings etc from trenches complete all as specified and directed by Engineer-in-Charge (Note : Earth work shall be measured and paid seperately )
Taking out /down old unserviceable GI pipe of 25/20 mm dia including all fittings etc from trenches complete all as specified and directed by Engineer-in-Charge (Note : Earth work shall be measured and paid seperately )
Supply , laying , jointing of CI Pipe spigot and socketed end pipes centrifugally class LA in any length of size 100 mm dia in trenches complete all as directed.
Supply , laying , jointing of CI Pipe spigot and socketed end pipes centrifugally class LA in any length of size 80 mm dia in trenches complete all as directed.
Supply and laying galvanised iron pipe, medium grade 50 mm bore with all new fittings, laid in trenches including jointing material etc complete all as specified and directed by Engineer-in-Charge
Supply and laying galvanised iron pipe, medium grade 40 mm bore with all new fittings, laid in trenches including jointing material etc complete all as specified and directed. by Engineer-in-Charge
Supply and laying galvanised iron pipe, medium grade 25 mm bore with all new fittings, laid in trenches including jointing material etc complete all as specified and directed. by Engineer-in-Charge
Supply and laying galvanised iron pipe, medium grade 20 mm bore with all new fittings, laid in trenches including jointing material etc complete all as specified and directed. by Engineer-in-Charge
M&L for run lead joints for 100mm dia spigot and socketed CI pipe fittings including spun yarn etc.
M&L for run lead joints for 80mm dia spigot and socketed CI pipe fittings including spun yarn etc.
M & L for CI fittings for Spigot & Socketed pipe as bends, tapers, tee pieces any type angle/radius and straight connection pieces etc upto 150 mm dia pipe as in repair etc complete all as specified and directed by Engineer-in-Charge
Supply & fixing 80 mm dia sluice valve PN 1:6 ISI marked confirming to IS-14846, flanged and drilled, gun metal spindle and iron wheel including jointing material such as nuts, bolts, washers and rubber sheet etc complete all as directed by Engineer-in-Charge.
Supply & fixing 100 mm dia sluice valve PN 1:6 ISI marked confirming to IS-14846, flanged and drilled, gun metal spindle and iron wheel including jointing material such as nuts, bolts, washers and rubber sheet etc complete all as directed by Engineer-in-Charge.
S & F Gun metal globe or gate valve (ISI marked), with iron wheel head, screwed both ends, suitable for 50 mm bore iron pipe and fixed including testing complete all as specifed and directed by Engr-in-Charge.
S & F Gun metal globe or gate valve (ISI marked), with iron wheel head, screwed both ends, suitable for 40mm bore iron pipe and fixed including testing complete all as specifed and directed by Engr-in-Charge.
S & F Gun metal globe or gate valve (ISI marked), with iron wheel head, screwed both ends, suitable for 25 mm bore iron pipe and fixed including testing complete all as specifed and directed by Engr-in-Charge.
S & F Gun metal globe or gate valve (ISI marked), with iron wheel head, screwed both ends, suitable for 20 mm bore iron pipe and fixed including testing complete all as specifed and directed by Engr-in-Charge.
M&L for brick masonary valve pit (type B) of size 120 x 120 x 120 cm (internal of chember ) depth of chember to be reckoned from the top of PCC in foundation to top the MS cover as 1.5 mtr and including MS sheet cover fabricated from 3 mm thick MS sheet and frame of angle iron 40 mm x 40 mm 6 mm with fixing arrangement , hinges and locking arrangement and painting two coat of synethetic enamel paint over a coat of red oxide primer on MS cover and frame , inlcuding necessary excavation and earth work in any type of soil , returning , filling in approved soil disposal of surplus soil to a distance not exc.50 mtr , 150 mm thick PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation , brick work in cement motor (1:6) 15 mm thick plastering in cement mortoar (1:4) (both internally and externally) 100 mm thick PCC (1:2:4) type B1 using 20 mm graded stone aggregate as in flooring complete all as directed.
M&L for brick masonary valve pit (type B) of size 90 x 90 x 90 cm (internal of chember ) depth of chember to be reckoned from the top of PCC in foundation to top the MS cover as 1.5 mtr and including MS sheet cover fabricated from 3 mm thick MS sheet and frame of angle iron 40 mm x 40 mm 6 mm with fixing arrangement , hinges and locking arrangement and painting two coat of synethetic enamel paint over a coat of red oxide primer on MS cover and frame , inlcuding necessary excavation and earth work in any type of soil , returning , filling in approved soil disposal of surplus soil to a distance not exc.50 mtr , 150 mm thick PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation , brick work in cement motor (1:6) 15 mm thick plastering in cement mortoar (1:4) (both internally and externally) 100 mm thick PCC (1:2:4) type B1 using 20 mm graded stone aggregate as in flooring complete all as directed.
M&L for brick masonary valve pit (type B) of size 45 x 45 x 45 cm (internal of chember ) depth of chember to be reckoned from the top of PCC in foundation to top the MS cover as 0.60 mtr and including MS sheet cover fabricated from 3 mm thick MS sheet and frame of angle iron 40 mm x 40 mm 6 mm with fixing arrangement , hinges and locking arrangement and painting two coat of synethetic enamel paint over a coat of red oxide primer on MS cover and frame , inlcuding necessary excavation and earth work in any type of soil , returning , filling in approved soil disposal of surplus soil to a distance not exc.50 mtr , 150 mm thick PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation, brick work in cement motor (1:6) 15 mm thick plastering in cement mortoar (1:4) (both internally and externally) 100 mm thick PCC (1:2:4) type B1 using 20 mm graded stone aggregate as in flooring complete all as directed.
Rewinding of squirrel cage induction electric motor of capacity 5 HP with super enameled copper wire of appropriate gauge including replacement of ball bearing of existing size complete all as specified and as directed by Engineer-in-charge.
Rewinding of Centrifugal electric motor of capacity 5 HP with super enameled copper wire of appropriate gauge including replacement of ball bearing of existing size complete all as specified and as directed by Engineer-in-charge.
M&L for painting of Centrfugal pumps of capacity 5 HP with two coats of synthetic enamel Paint over one coat of red oxide primer complete all as specified and directed by Engr in Charge.
Cleaning of RCC Under ground tank reservoir up to 50000 gallon capacity by drain out the contaminated muddy water from bottom surfaces of the tank by using of pump and motor and cleaning the inside and bottom surfaces of walls with help of wire brush and using specified dosage of Potassium permanganate and cleaned water than drain out completely material to the entire satisfaction of Engr in Charge with and including writting letters 5 CM height capacity of Tank and date of Cleaning of tank , with synthectic enamel paint on the other surface of the tank complete all as specified and directed.
Cleaning of RCC Under ground tank reservoir up to 100000 gallon capacity by drain out the contaminated muddy water from bottom surfaces of the tank by using of pump and motor and cleaning the inside and bottom surfaces of walls with help of wire brush and using specified dosage of Potassium permanganate and cleaned water than drain out completely material to the entire satisfaction of Engr in Charge with and including writting letters 5 CM height capacity of Tank and date of Cleaning of tank , with synthectic enamel paint on the other surface of the tank complete all as specified and directed.
Cleaning of RCC over head tank reservoir up to 50000 gallon capacity by drain out the contaminated muddy water from bottom surfaces of the tank by using of pump and motor and cleaning the inside and bottom surfaces of walls with help of wire brush and using specified dosage of Potassium permanganate and cleaned water than drain out completely material to the entire satisfaction of Engr in Charge with and including writting letters 5 CM height capacity of Tank and date of Cleaning of tank , with synthectic enamel paint on the other surface of the tank complete all as specified and directed.
Supply and fix in replacement of contactor AC rating 15 Amps, type MK-1,Motor Output 3 Phase 415V, 50Hz complete all as specified and directed.
Supply and fix in replacement of single phase preventrr relay Type TSP-2, 3 Phase 415V, 50Hz complete all as specified and directed.
Supply and fix in replacement of metal name plate which is showing pump capacity,make and SM/MES number with fixing arrangment on wall of suitable size complete all as specified and directed.
S&F in replacement MCCB 200 Amp 4 Pole of rupturing capacity 36 KA with fixed thermal and fixed magnetic complete all as specified and directed.
S&F in replacement MCCB 160 Amp 4 Pole of rupturing capacity 25 KA with fixed thermal and fixed magneticcomplete all as specified and directed.
S&F in replacement MCCB 125 Amp 4 Pole of rupturing capacity 25 KA with fixed thermal and fixed magneticcomplete all as specified and directed.
S&F in replacement MCCB 100 Amp 4 Pole of rupturing capacity 25 KA with fixed thermal and fixed magneticcomplete all as specified and directed.
S&F in replacement MCCB 63 Amp 4 Pole of rupturing capacity 25 KA with fixed thermal and fixed magneticcomplete all as specified and directed.
S&F in replacement MCB 63 Amp 4 Pole of rupturing capacity 10 KA, C series complete all as specified and directed.
S&F in replecement MCCB 320 Amp 4 Pole of rupturing capacity 36 KA complete all as specified and directed.
Taking out U/S LT Cable from trench/on wall of any size complete all as specified and directed by Engr in Charge
Supply, laying, jointing and testing LT cable XLPE insulated, armoured and PVC bedded 1100 volts grade,heavy duty with aluminium conductor 120 Sqmm 3.5 core laid in ducts/through pipes, in floor, on poles, in trenches complete all as specified.
Supply, laying, jointing and testing LT cable XLPE insulated, armoured and PVC bedded 1100 volts grade,heavy duty with aluminium conductor 95 Sqmm 3.5 core laid in ducts/through pipes, in floor, on poles, in trenches complete all as specified.
Supply, laying, jointing and testing LT cable XLPE insulated, armoured and PVC bedded 1100 volts grade,heavy duty with aluminium conductor 70 Sqmm 3.5 core laid in ducts/through pipes, in floor, on poles, in trenches complete all as specified.
Supply, laying, jointing and testing LT cable XLPE insulated, armoured and PVC bedded 1100 volts grade,heavy duty with aluminium conductor 50 Sqmm 3.5 core laid in ducts/through pipes, in floor, on poles, in trenches complete all as specified.
Supply, laying, jointing and testing LT cable XLPE insulated, armoured and PVC bedded 1100 volts grade,heavy duty with aluminium conductor 35 Sqmm 3.5 core laid in ducts/through pipes, in floor, on poles, in trenches complete all as specified.
Supply, laying, jointing and testing LT cable XLPE insulated, armoured and PVC bedded 1100 volts grade,heavy duty with aluminium conductor 25 Sqmm 4 core laid in ducts/through pipes, in floor, on poles, in trenches complete all as specified.
Supply, laying, jointing and testing LT cable XLPE insulated, armoured and PVC bedded 1100 volts grade,heavy duty with aluminium conductor 16 Sqmm 4 core laid in ducts/through pipes, in floor, on poles, in trenches complete all as specified.
Supply, laying, jointing and testing LT cable XLPE insulated, armoured and PVC bedded 1100 volts grade,heavy duty with aluminium conductor 10 Sqmm 2 core laid in ducts/through pipes, in floor, on poles, in trenches complete all as specified.
Material and labour for sand cushioning with a layer of sand 8 cm thick before laying of cable and 15 cm thick after laying of cable in trenches complete all as specified.
Supplying & laying old size sub calss 'B' bricks laid flat in trenches over the cable with length of bricks perpendicular to the direction of cable, adjacent/abutting each other, complete all as specified and as directed by Engiineer-in-Chage.
Prepration of old Steel Surfaces and applying two coat of synthetic enamel white paint to Steel tubular /PCC Pole and upto 1 Mtr height from ground level alternative in Yellow and black strips of 30 CM height each including numbering of Pole No with black paint complete all as specified and directed by Engr in charge.
Dismantling / Taking down of Old broken HT/LT Danger notice Plate of any size complete all as specified and directed.
Supply and fixing Danger notice Plate of 1.6 mm thick mild steel sheet , vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS Clamps , bolts and nuts of approved size, for LT ,20x15 CM size.
Supply and fixing Danger notice Plate of 1.6 mm thick mild steel sheet , vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS Clamps , bolts and nuts of approved size, for HT ,25x20 CM size.
Trimming/cutting of trees branches.bushes obstructing the HT/LT lines making clear distance of 3 RM from the outer conductors of OH Lines all around and all substations fencing around pump house area, below surrounding of OHTs including removing of branches/ bushes of trees from site all as directed.
M & LMake bore to road width under PCC foundation or road for laying of cable putting GI pipe for protection of cables
Supplying & fixing in replacement GI pipe light grade 50 mm nominal bore for passing of cable fixed to poles/walls/laid under floor/roads complete with and including, fittings as requited all as specified.
Supply and fixing in replacement of GI tubing light grade of 80 mm dia for cable protection on pole/wall/floor or in trenches and drain etc complete with necessary clamp, nut, bolts and washers and socket and making good the distributed surface of wall all as specified and directed.
Material and Labour for painting of LT Panels including cleaning of exposed surface with brush and empry paper including two coat of painting with smoke grey paint, including cleaning of all terminals with CRC Sprey and provides locking arrngement, any size of LT Panel complete all as specified.
Material and Labour for painting of LT Panels including cleaning of exposed surface with brush and empry paper including two coat of painting with smoke grey paint, including cleaning of all terminals with CRC Sprey any size of LT Panel complete all as specified.
M&L for Synthetic Insulating Mat for Electrical Instrument of size 2mx1mx12mm complete all as specified and directed by Engr in Charge.
Supply and fixing of LT cable joint kit size 6 sqmm to 16 Sqmm all as specified and directed.
Supply and fixing of LT cable joint kit size 25 sqmm to 50 Sqmm all as specified and directed.
Supply and fixing of LT cable joint kit size 70 sqmm to 95 Sqmm all as specified and directed.
Relaying/rerouting HT/LT XLPE cable of any size and any type after fault detection including neccessary earth work and relaying the old bricks after returning filling as specified and directed by Engr-in-charge at site
Material & labour for earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6.3mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised Iron strip of 32 x 6 mm as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 of SSR (Part-I) complete all as specified and directed.
M & L for Earthing complete with galvanized iron earth plate electrode 60 cm x 60 cm x 6.30 mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanized earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electric plate No 5 of SSR Part-I connected to continuous earth wire on main switch board all as specified or indicated and testing on completion including provision of earth wire protection by 15 mm dia medium grade GI pipe and watering pipe shall be 20 mm bore, medium grade including excavation & earth work, PCC pit with RCC cover, charcoal salt funnel, GI wire up to 7.5 mtrs length complete all as spd and directed.
M&L for removing old earthing and M&L for commissioning, installation and testing of maintenance free UL approved copper bonded earth rod of 10 feet length, 17.2 mm dia. made of high tensile low carbon steel rod , molecularly bonded with 99.9% electrolytic grade copper on outer surface ( minimum copper bonding thickness - 250 microns) with exothermally jointed copper bus bar of 50 X 6 X 200 mm for connection. The rod and exothermic joint together successfully tested at 25 KA fault current by CPRI with 50 Kg eco friendly earth enhancing compound with each earth rod. The earth pit should be 125 mm dia. the compound should comply to IEC:62561-7 having passed leaching, corrossion, sulphur and resistivity test as per IEC: 62651-7 by NABL accredit Lab with FRP earth pit cover of top size lockable Lid. It includes GI Protection pipe light grade of size 40 mm dia. with GI strip of size 32X6 mm upto test point complete all as specified and directed by Engr-in-charge. Make JMV LPS Ltd/ OBO/ENNOV Infra solutions Pvt. Ltd/ erico /powerbolt including connecting of Strip between two earthing complete all as specified and directed by Engr in charge (a) The test result of each set of earthing is less than 1 Ohm. All earthing test will be carried out in presence of MES Rep, manufacturer Rep and test result will be recorded in a register with sign of manufacturer & Engr-in-charge. (b) 5 Year gaurantee certificate from company for maintaining earth result less than 1 Ohm will be submitted by contractor c) 1425 RTC SS universal clamp of size 175 x 50 x 3mm (d) Earth enhancing compound (PROCEM) ECS GB 25 tested as per IEC 62561-7-25Kg (e) Chemical earthing will be installed by manufacturer Rep and purchase voucher of earthing will be produced before payment. Payment shall be made only after getting satisfactory result.
S&F of copper strip of size 20 x 3.15 mm on PVC/porcelain insulator at suitable distance with saddeles and fixing screw etc for roof/Wall conductors and down conductors above ground all joints of copper strip should be brazed properly complete all as specified and directed.
S&F test point terninal block made of of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed inlcuding 3 Nos 8 mm dia 25 mm long hexagonal head screw complete all as specified and directed.
M&L for fixing the procelin cleat with the help of nut,bolts clamps etc to fix the strips of various size and types to separate from groung and wall as directed at site by Engr in charge complete all as specified
M&L for PVC conduit heavy duty of 40 mm dia size for the protection of the earthing strip on wall/roof with the help nuts ,bolts clamps, PCC work etc as directed at site by Engr in charge
Supplying and fixing 1100 Volts grade heavy duty cable PVC insulated aluminium conductor , served with inner sheathing of PVC Tape and overall PVc sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4 mm suspension wire , one twin core cable circular of size 10 Sqmm complete all as specified and directed.
S&F in replecement cable route indicator made out cast iron and embedded HT/LT cable and size of the cable on the plate of size 80mm dia 5 mm thick and grouting lugg of suitable size including grouting in PCC foundation of suitable size complete all as specified
S&F in replacement Time switches with battery backup 3P module, 24 hours program, programable every 30 min, backup of 100 hrs current capacity 16 Amps complete all as specified and directed by Engineer-in-Charge
Taking down Unserviceable flood light from 15 mtr high mast pole through mechanically or manually after repair/replacement of flood light should be refix same place complete all as specified & directed by Engr-in-charge Note :- All T&P i.e ladder, tools, safety gloves etc will be provided by the contractor without any extra cost.
Supply & Fixing of 150 watts LED Flood light for high mast light highly efficient LED Flood light with lens made of pressure die cast aliminium housing, extruded aluminium heat sinks & enclosed with toughened glass IP-66 fitted on the wall/ roof top/pole etc. with the help of nuts,bolts, clamps PCC work including connection with 2.5 Sqmm 3 core copper wire complete all as specified & directed by Engr-in-charge.
Supply & Fixing in replacement of Diver for flood light 150 Watts complete all as specified & directed by Engr-in-charge.
Dismantling/Taking down of Street light/Flood light of any capacity and any size from 09 mtr LT pole, tower postand building complete all as directed.Note :- All T&P i.e ladder, tools, safety gloves etc will be provided by the contractor without any extra cost.
Supply & Fixing of 100 watts LED Flood light highly efficient LED Flood light with lens made of pressure die cast aliminium housing, extruded aluminium heat sinks & enclosed with toughened glass IP-66 fitted on the wall/ roof top/pole etc. with the help of nuts,bolts, clamps PCC work including connection with 2.5 Sqmm 3 core copper wire complete all as specified & directed by Engr-in-charge.
Supply & Fixing in replacement of Diver for flood light 100 Watts complete all as specified & directed by Engr-in-charge.
Supply and fix in of 45 W IP 66 LED Street light luminaire comprising of die cast aluminium housing with weather proof gasket for lamp & driver compartment with system wattage of 60 W . The LED make must be of CREE/NICHIA/OSRAM with 120 degree view angle , > 120 lumen/watt , lumen maintenance > 70 % at 50,000 hrs ,colour temperature of 5000- 6500K,>70 color rendering and LM 80 test compliance . The driver must be integral APFC and constant current type having THD <15% and power factor > 0.95 with short circuit protection , open circuit protection , reverse polarity protection , high voltage protection , protection against 10 KV high surges and comply to IEC 60598-1 , IEC 61000-3-2, IEC 61547. the luminaire must have secondary optics with perfectly matched lens for better light control complete all as specified and directed by Engr in charge
S&F in repairs PVC junction box of size 25x20x15cm with hinged door including loking arrangement, 04 Nos aluminium bus bar complte with necessary clamp, nut, bolt including single pole MCB of 6 Amp, complete all as specified and directed by Engr in charge.
Supply, installing, testing and commissioning factory made LT feeder pillar box Outdoor type platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system all as specified and directed having bus bar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 3.15 mm CRCA MS sheet with front opening type with double door shutter and locking arrangement (including provn of lock with 2 keys), powder coated finish (over a coat of red oxide), primer on outside and two coats of red oxide primer on inside surface with TPN aluminium bus bar of rating not less than 200Amps suitable foundation.Make Supertech/Power Control & System
Taking down old unserviceable GOD from two pole structure complete all as specified and directed by Engr in Charge
Switch air break gang operated tripple pole mechanically operated from ground level mounted on 15 insulators, outdoor type suitable for vertical installation single break provided with locking arrangement for operating handle including seven levers "Navtal" lock consisting of mild steel channel, HT post top insulator copper alloy high pressure asembly with drop out expulsion fuses for phases, operating rod of 20mm dia medium grade G.I pipe complete confirming to IS-1018 of 1972 with continous current rating 200Amps, 11000 volts grade complete all as specified.
Taking out U/S HT Cable from trench of any size complete all as specified and directed by Engr in Charge
Supplying, laying, jointing and testing underground cable XLPE insulated screened armoured and PVC bedded HT 11000 volts grade (heavy duty) with aluminium conductor 3 core, 150 Sqmm, laid in ducts/through pipes, in floor, on poles, in trenches complete all as specified.
Dismantling of HT cable Jointing Kit of any type and any size complete all as specified and directed by Engr in Charge.
M&L for Cable Jointing Kit for 11 KV (Earthed) grade cable for outdoor termination heat shrinkable type joint complete with jointing material and acessories suitable foe 3 Core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm complete all as specified and directed by Engr in charge.
M&L for Cable Jointing Kit for 11 KV (Earthed) grade cable for indoor termination heat shrinkable type joint complete with jointing material and acessories suitable foe 3 Core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 Sqmm complete all as specified and directed by Engr in charge.
Material and labour for disconnection and dismantling of existing transformer of capacity up to 160 KVA for repair work and refixing and reconnecting the same complete all as directed as under:- i)Replacement of gasket, nuts bolts and washer. ii)Replacement of neoprene rubber washer iii)Replacement of silica gel iv)Replacement of copper lugs including ACSR jumpers from HT OH line to primary side of TF v)Cleaning of bush insulator LT/HT side vi)Tightening of connection of earthing lead to neutral & body vii)Replacement of MS cable box cover as per requirement at site viii)Replacement of HT & LT bush ix)Replacement of HT & LT bush copper Rod
Material & Labour for filling of new transformer oil up to minimum level, break down value of transformer oil should not be less than 50 KV complete all as directed.
Material & Labour for filtration/dehydration of transformer oil up to break down valve reaching upto 50 KV dilectric strength complete all as directed. NOTE : Contractor will arrange filtration plant machine at site of transformer.Dehydration work will be carried out in working condition and electric supply will be taken from same transformer.
Material and labour for preparation of old steel surfaces and applying one coat of synthetic enamel paint to steel surface Transformer /voltage stabilizer/isolation Transformer after disconnecting the electrical connections and reconnecting LT cables after painting including writing of MES No. complete as specified and directed by Engr-in-Charge. Note: Spray paint to be used for painting surface of appliance after removing the old paint
M&L for replacement of oil temperature indicator including nuts, bolts and gasket including taking down complete upto 200 KVA, complete all as specified & directed by Engineer-in-Charge.
Opening/stripping off voltage stablizer of capacity 50 KVA to 150 KVA including draining off oil, washing & cleaning duct, dit & sludge deposit etc. from all parts. Removing damaged/deffective parts requiring replacement,making internal connection servicing of bushings and reassembling the voltage stablizer after repair and replacement work including new cork gasket, packing nuts, bolts, washer, etc. Complete all as directed. Note : Servicing will be done by reputated company rep at site only
M&L for calibration/overhauling/servicing of relay any type voltage,current(e.g. Earth fault relay/Over current relay,etc) for 11 KVA HT panel.The setting of these relays should be as per the PSPCL norms so that individual breaker/feeder should be tripped and fault is not travelled back to MRS and subsequently to PSPCL power house.The calibration of relay is to be done by a reputed firm and it is to be submitted to to the AGE E/M.All the calibration should be done in the presence of Engineer-in-charge.Note :- Any relay and HRC Fuse required during the work which should be measured in quoted rate.
Disconnecting the existing servicing electric supply from HT 11KV system of any make type taking out switch gear from SF-6 circuit breaker(any type)/VCB/OCB,cleaning from inside and out side by using CRC-26 spray or any other cleaning agents which can improve the electrical conductivity or properties,greasing whereever required overhuling of switchgear ,checking the fixed/moving contacts of all the 3 phases adjusting electrical/electronic/mechanical components all as per mfg instruction manual and standard practice & reassembling the same after necessary servicing repair including testing and commissioning in its original position & necessary connection etc all as specified and directed.This work is to be get done from company authorised sales and supplier dealers and all as specified and directed.
S&F in replacement on load change Over Switch 100 Amp in Sheet Steel enclosure complete all as specified and directed. Make-IndoAsian/Standard/C&S
S&F in replacement on load change Over Switch 125 Amp in Sheet Steel enclosure complete all as specified and directed.Make-IndoAsian/Standard/C&S/Havells
Servicing of DG set including replacement the set of fuel pre- filters and fine -filters,air filter element,flusing of radiator and filling coolent upto max. level & engine oil change including engine oil change,20 W 40 grade(18 ltrs for 62.5 KVA & 2X9 ltrs=18 ltrs for 20KVA sets) as per sample and make for the following capacities of DG sets. Each set shall be comprising complete set of pre/fine filters complete all as directed.
Supply and replace set of lube / engine oil filters as per sample and make for the following capacities of DG sets.
S & F in replacement of battery lead of copper conductor PVC insulated multi strand 1.25 Mtr long (two Nos) duly fixed with terminals and lugs complete all as directed.
Removal of old painted surface of DG Set complete with fuel tank by scraping with emry paper and cleaning by thinner and finishing the surface smooth for new paiting of two coat of spray painting with synethetic enamal paint complete including writing of SM/MES No and colour code all as directed by Engineer-in-Charge.
Supply and fix in replacement of generator door hinges metal type with nut bolts or screws for DG set any make any type complete all as specified and directed
S & F in replacement indicator lamps AC 230 V, LED type for the panel boards complete all as specified and directed.
S & F in replacement under/over voltage relay input voltage 110-220 V AC suitable for AMF panel complete all as specified and directed.
S & F in replacement engine starting relay DC 12V/24V suitable for AMF panel complete all as specified and directed.
S & F in replacement 8 pin relay Base Socket voltage range DC voltage 12 V to 230 V and AC voltage 12 V to 440V suitable for AMF panel complete all as specified and directed.
S & F in replacement contact element NO-NC suitable for AMF panel complete all as specified and directed.
S & F in replacement green colour Actuator Push button with complete set suitable for AMF panel complete all as specified and directed.
S & F in replacement Red colour Actuator Push button with complete set suitable for AMF panel complete all as specified and directed.
S & F in replacement Automotive relay, 12 VDC, 50 Amp power relay quick connected with complete set suitable for AMF panel complete all as specified and directed.
S & F in replacement Ameter of range as required for the Gen/ AMF panel complete all as specified and directed.
S & F in replacement Volt meter 0 to 600 V range suitable for the Gen/ AMF panel complete all as specified and directed.
S & F in replacement 3 pole power contactor 55 A, type MNX 40 CAT No. CS94190 complete all as specified and directed.
M&L for reconditioning of battery 12 volt 150 AH any make and any type opening up and taking out all dead battery cell plates, terminal post and mixture of acid using same container of battery and replacing of new solution battery cell, plates, making terminals all as specified and directed
M&L for reconditioning of battery 12 volt 60 AH any make and any type opening up and taking out all dead battery cell plates, terminal post and mixture of acid using same container of battery and replacing of new solution battery cell, plates, making terminals all as specified and directed
S&F Battery Charger of capacity 12V suitable for AMF Panel complete all as specified and directed.
Supply and replace in repair Glow Sign Board box type size 1.50x0.46x0.23 m having base height 0.75 M, which is show Dg capacity,SM/MES Number and location including painting black colour on metal parts excavation and using PCC 1:2:4 for foundation complete all as specified and directed.
Repairing the self starter after removing from the Gen set of capacity 160 KVA and transporting to an authorised sevice centre complete all as specified and directed.
S & F in replacement heavy duty battery terminals, heavy duty brass forged with nuts and bolts complete.
Supply and fix in replacement Benjo bolts complete including warsher (02 washers for each bolt) complete all as specified and directed.
Supply and fix in replacement fuel pipe filter to FIP wire braided complete all as specified and directed.
Supply and fix in replacement fuel pipe upto 15 mm size from fuel tank to the DG set & over flow return complete all as specified and directed.
GUPTA AND ENGINEERS
POOJA CONSTRUCTION COMPANY
SWARN SINGH AND CO.
Aman Enterprises
M/s Luxmi Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .