| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 CrAdmitted-Finance | ₹4.6 Cr | L1 | Admitted-Finance |
| 2 | L2₹5.0 Cr+₹31.5 L (6.78%)Admitted-Finance | ₹5.0 Cr+₹31.5 L (6.78%) | L2 | Admitted-Finance |
| 3 | L3₹5.0 Cr+₹34.7 L (7.46%)Admitted-Finance | ₹5.0 Cr+₹34.7 L (7.46%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Trade Linkers Associates L2 | Ali Mohammad Baba and Sons L1 | JK Electric Engineers Pvt. Ltd. L3 |
|---|---|---|---|---|---|---|
| 1.00(A)Design, Engineering, manufacture, supply, packing, of following | ||||||
| 2.00 | 50MVA- 132/33KV Power Transformer with OLTC,HV, LV Connectors and other required fittings, NCTs and SCADA Compatible RTCC Panel | 1 | NO. | 4,74,15,400 ₹4,74,15,400 | 4,36,74,500 ₹4,36,74,500 Lowest | 4,73,00,000 ₹4,73,00,000 |
| 3.00 | Nitrogen Injection fire Protection System including all the required fittings, Panels, Oil Tank and other aeccessories and material required for execution of civil works | 1 | NO. | 15,00,000 ₹15,00,000 Lowest | 20,70,780 ₹20,70,780 | 16,00,000 ₹16,00,000 |
| 4.00(B) FORWARDING, TRANSPORTAION, UNLOADING, HANDLING, STORAGE, PRESERVATION, ERECTION, DEHYDRATION, TESTING & COMMISSIONING OF FOLLOWING | ||||||
| 5.00 | 50MVA- 132/33KV Power Transformer with OLTC,HV, LV Connectors and other required fittings, NCTs and SCADA Compatible RTCC Panel | 1 | NO. | 5,00,000 ₹5,00,000 | 4,50,000 ₹4,50,000 Lowest | 7,00,000 ₹7,00,000 |
| 6.00 | Nitrogen Injection fire Protection System including all the required fittings, Panels, Oil Tank and required civil Civil works to be executed as per the Design of NIFPES | 1 | NO. | 50,000 ₹50,000 Lowest | 1,60,000 ₹1,60,000 | 50,000 ₹50,000 Lowest |
| 7.00Dismantling of the old three phase 20 MVA, 132/33 kV Power Transformer | ||||||
| 8.00 | Dismatnling of the Power Transformer including dusmantling of radiators, fans, bushings, jumpers, cable connections including removal of earthing | 1 | Job | 50,000 ₹50,000 | 27,200 ₹27,200 Lowest | 2,00,000 ₹2,00,000 |
| 9.00 | Removal/draining of old transformer oil from the transformer tank including shifting of drained oil barrels to dumping site | 1 | Job | 50,000 ₹50,000 | 13,600 ₹13,600 Lowest | 50,000 ₹50,000 |
| 10.00 | Manual/Mechanical dragging of the Power Transfomer upto store site upto 200 mtrs | 1 | Job | 50,000 ₹50,000 | 68,220 ₹68,220 | 30,000 ₹30,000 Lowest |
Tender Value
₹3.9 Cr
EMD Value
₹7.8 L
Closing Date
14 Jul 2022, 4:00 pmClosed
Executive Engineer TLMD-II Pampore
Executive Engineer TLMD-II Pampore
Design, Engineering, Manfacturing, Testing, Installation and Commissioning of 50 MVA three phase 132/33 kv power transformer with OLTC, SCADA, NIFPES and dismantling of the age old 20 MVA 132/33 KV Power Transformer at Grid Station Awantipora
2022_PDD_170745_1
TLMD-II/ 16 of 2022-23
Open Tender
Electrical Works
Item Rate
90 days
Grid Station Awantipora
Please refer Tender documents.
5 documents required · 5 mandatory
₹5,000
Yes
Executive Engineer TLMD-II Pampore
₹7.8 L
Yes
23 Aug 2022
25 May 2022
15 Jul 2022
25 May 2022
14 Jul 2022
25 May 2022
Amount
(A)Design, Engineering, manufacture, supply, packing, of following
50MVA- 132/33KV Power Transformer with OLTC,HV, LV Connectors and other required fittings, NCTs and SCADA Compatible RTCC Panel
Nitrogen Injection fire Protection System including all the required fittings, Panels, Oil Tank and other aeccessories and material required for execution of civil works
(B) FORWARDING, TRANSPORTAION, UNLOADING, HANDLING, STORAGE, PRESERVATION, ERECTION, DEHYDRATION, TESTING & COMMISSIONING OF FOLLOWING
50MVA- 132/33KV Power Transformer with OLTC,HV, LV Connectors and other required fittings, NCTs and SCADA Compatible RTCC Panel
Nitrogen Injection fire Protection System including all the required fittings, Panels, Oil Tank and required civil Civil works to be executed as per the Design of NIFPES
Dismantling of the old three phase 20 MVA, 132/33 kV Power Transformer
Dismatnling of the Power Transformer including dusmantling of radiators, fans, bushings, jumpers, cable connections including removal of earthing
Removal/draining of old transformer oil from the transformer tank including shifting of drained oil barrels to dumping site
Manual/Mechanical dragging of the Power Transfomer upto store site upto 200 mtrs
Trade Linkers Associates
JK Electric Engineers Pvt. Ltd.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.09 MB
SBDAAUG.pdf
Tender Documents • 1.78 MB
BOQ_400846.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .