Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.2 LAccepted-AOC 0 HISAR HISAR HARYANA 125004 UDYAM HR 06 0052049 | HISAR | HARYANA | 125004 | L1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L2₹48.1 L+₹1.1 L (2.28%)Rejected-Finance 121004 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹49.3 L+₹2.3 L (4.88%)Rejected-Finance 251A 56 N S C BOSE ROAD KOLKATA 700 047 | KOLKATA | KOLKATA | WEST BENGAL | 700047 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹50.3 L+₹3.3 L (6.98%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹50.6 L+₹3.6 L (7.72%)Rejected-Finance 165 UTTAR KASTODANGA ROAD KOLKATA 700 061 | KOLKATA | KOLKATA | WEST BENGAL | 700061 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
20 Jul 2020, 6:00 pmClosed
GE (FW) Kolkata
D9 COMMISSARIAT ROAD HASTINGS KOLKATA 700 022
REPAIR/MAINTENANCE OF MISC ELECTRICAL SERVICES AT ADV AF HQ AND REPAIR/ MAINTENANCE OF INTERNAL ELECTRIFICATION WITH FITTINGS, FIXTURES AND REPLACEMENT OF UNSERVICEABLE WIRING IN CENTRAL INSTITUTION AND MD ACCN INSIDE FORT WILLIAM UNDER GE(FW) KOLKAT
2020_MES_348222_2
GE (FW)/8660/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Fort William Kolkata
Ref tender document
6 documents required · 6 mandatory
₹500
Yes
GE (FW) Kolkata
₹86,000
Yes
10 Aug 2020
29 Jun 2020
27 Jul 2020
29 Jun 2020
20 Jul 2020
29 Jun 2020
Amount
SCHEDULE 'A' PART-I (INTERNAL ELECTRIFICATION) Taking down copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants, regulators, sockets etc excluding light fitting for taking credit removing from site and making good disturbed surface of walls, floors etc.complete all as specified and directed.
Materials and Labour for surface type point wiring with 1.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing capping medium duty complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed.
All as per item No. 02 above but for one 5 amps switch socket outlet on same board controlled by another switch, complete all as specified and directed (surface type point wiring with terminal box).
All as per item No. 02 above but for one 5 amps switch socket combination on independent board, complete all as specified and directed (surface type point wiring with terminal box).
All as per item No. 02 above but using 2.5 sqmm single core multi stranded copper conductor FRLS PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 1.5 sqmm green FRLS PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (surface type point wiring with terminal box).
Materials and Labour for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC conduit complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed. (NOTES: - (i) Where tube light fitting is to be fitted/suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage)
All as per item No. 06 above but for one 5 amps switch socket outlet on same board controlled by another switch, complete all as specified and directed (concealed type point wiring with terminal box).
All as per item No. 06 above but for one 5 amps switch socket combination on independent board, complete all as specified and directed (concealed type point wiring with terminal box).
All as per item No. 06 above but using 2.5 sqmm single core multi stranded copper conductor FRLS PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 1.5 sqmm green FRLS PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (concealed type point wiring with terminal box).
Materials and Labour for surface type point wiring with 1.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing capping complete with all fittings and accessories, (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for One light point or one fan point or bell point controlled by one switch or bell push complete all as specified and directed. (NOTE :- Quoted rate shall be exclusive of the cost of terminal box & laminate cover which shall be measured seperately.
All as per item No. 10 above but for one 5 amps switch socket outlet on same board controlled by another switch, complete all as specified and directed (surface type point wiring without terminal box).
All as per item No. 10 above but for one 5 amps switch socket combination on independent board, complete all as specified and directed (surface type point wiring without terminal box).
All as per item No 10 above but using 2.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core for line conductor and 1.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core for earth continuty wire for one 15/16 amp multi socket out let independent (surface type point wiring without terminal box).
Materials and Labour for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC conduit complete with all fittings and accessories (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for One light point or one fan point or bell point controlled by one switch or bell push complete all as specified and directed. (NOTE :- (i) Where tube light fitting is to be fitted/suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Quoted rate shall be exclusive of the cost of terminal box & laminate cover which shall be measured seperately. (iii) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage)
All as per item No 14 here-in-before but for one 5 pin 5/6 amps multisocket outlet point in independent board (concealed wiring) (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
All as per item No 14 here-in-before but for one 5 pin 5/6 amp socket out let point in the same switch board of light points (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
All as per item No 14 above but using 2.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core for line conductor and 1.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core for earth continuty wire for one 15/16 amp multi socket out let independent. (concealed wiring) (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
Taking down carefully by unscrewing from boards/outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators etc for reuse at site or carrying to store (to be measured only when found serviceable in all respects complete for reuse) complete all as specified and directed.
PIANO SWITCH, 5/6 AMPS, SINGLE POLE, ONE WAY
S & F new Switch piano, flush type
Re-fixing of switch piano, any type (retrieved from taking down of point wiring)
PIANO SWITCH, 15/16 AMPS, SINGLE POLE, ONE WAY
S & F new Switch piano, flush type
Re-fixing of switch piano, any type (retrieved from taking down of point wiring)
SOCKET OUTLET, 6 IN 1, 3 PIN, 6/16 AMPS,
S & F new socket outlet, flush type
Re-fixing of socket outlet, 5/6 Amps any type (retrieved from taking down of point wiring)
SWITCH SOCKET COMBINATION OUTLET, 6 IN 1, 3 PIN, 6/16 AMPS,
S&F new switch socket combination outlet, flush type with indicator lamp
Re-fixing of switch socket combination outlet, any type (retrieved from taking down of point wiring)
SOCKET OUTLET, 5 PIN, 5/6 AMPS,
S & F new socket outlet, flush type with indicator lamp
Re-fixing of socket outlet, 6/16 Amps any type (retrieved from taking down of point wiring)
SWITCH SOCKET COMBINATION OUTLET, 3/5 PIN, 5/6 AMPS,
S & F new switch socket combination outlet, flush type with indicator lamp
Re-fixing of switch socket combination outlet, 6/16 Amps any type (retrieved from taking down of point wiring)
BELL PUSH, 5/6 AMPS, 240 VOLTS
S&F new Bell push, flush type
Re-fixing of bell push, any type (retrieved from taking down of point wiring)
CALL BELL/BUZZER, AC 230/240 VOLTS, SINGLE POLE
S&F new Call bell, musical type
S&F new Call bell, ding dong type
Re-fixing of Call bell, any type (retrieved from taking down of point wiring)
Re-fixing of electric call bell, ding dong type (retrieved from taking down of point wiring)
CEILING ROSE, THREE TERMINALS, 240 VOLTS
S&F new Ceiling rose, surface type
Re-fixing of ceiling rose, any type (retrieved from taking down of point wiring)
FAN REGULATOR, STEPPED TYPE, 5 SPEED CONTROL, 230/240 VOLTS
S&F stepped type electronic fan regulator, flush type
Re-fixing of fan regulator, any type (retrieved from taking down of point wiring)
LAMP HOLDER, PVC/POLYCARBONATE BODY
S&F lamp holder with back plate suitable for batten/pendant fittings or to be mounted on walls
Re-fixing of lamp holder, any type (retrieved from taking down of point wiring)
MODULAR SWITCH, 5/6 AMPS, 1 MODULE, ONE WAY
S & F Modular Switch 1 way 6 A, 1 module
Re-fixing of modular switch, 5/6 Amps, 1 module (retrieved from taking down of point wiring)
MODULAR SWITCH, 16 AMPS, 1 MODULE, ONE WAY
S & F Modular Switch 1 way 16 A, 1 module
Re-fixing of modular switch, 16 Amps, 1 module (retrieved from taking down of point wiring)
MODULAR SOCKET, 6 AMPS, 2 MODULE
S & F Modular Socket 6 A, 2/3 pin combined 2 module
Re-fixing of modular socket, 6 Amps, 2 module (retrieved from taking down of point wiring)
MODULAR SOCKET, 16 AMPS, 2 MODULE
S & F Modular Socket 6 A/ 16 A, 2/3 pin combined 2 module
Re-fixing of modular socket, 6 A/ 16 A, 2/3 pin combined 2 module (retrieved from taking down of point wiring)
MODULAR FAN REGULATOR
S & F Modular Fan step regulator, 120 watt, 2 module
Re-fixing of modular Fan step regulator, 120 watt, 2 module (retrieved from taking down of point wiring)
MODULAR BELL PUSH
S & F Modular Bell push 6A, 1 module
Re-fixing of modular Bell push 6A, 1 module (retrieved from taking down of point wiring)
MODULAR BLANKING PLATE
S & F Modular Blank plate, 1 module
Re-fixing of modular Blank plate, 1 module (retrieved from taking down of point wiring)
MODULAR TYPE COVER PLATE WITH FRAME
S & F Modular type White cover plate with frame 1 module
S & F Modular type White cover plate with frame 2 module
S & F Modular type White cover plate with frame 3 module
S & F Modular type White cover plate with frame 4 module
S & F Modular type White cover plate with frame 6 module
S & F Modular type White cover plate with frame 8 module
S & F Modular type White cover plate with frame 12 module
MODULAR TYPE METAL FLUSH BOX
S & F Modular type Metal Flush box 1/2 module
S & F Modular type Metal Flush box 3 module
S & F Modular type Metal Flush box 4 module
S & F Modular type Metal Flush box 6 module
S & F Modular type Metal Flush box 8 module
S & F Modular type Metal Flush box 12 module
S&F in repairs surface mounted LED luminaire, 1 X 20 Watt in aluminium housing, with polycarbonate diffuser & integrated electronic driver complete with all other accessories internally prewired and including connecting up with three core flexible copper conductor cable of suitable size incl taking down existing fitting complete all as specified and directed.
(MAKE: HAVELLS, Model: Lumline Plus / HALONIX, Cat No: HLB-03-20-CW-AL / SURYA, Cat No: SLE BTN T8 20W / BAJAJ, Cat No: BCLSBAL 20W CW / JAQUAR, Cat No: LGLZ01X020XC / PANASONIC, Cat No: PBTM08204 / HPL, Cat No: HLPT51520CW / CROMPTON, Cat No: LDL-20-CDL or equivalent model in PHILIPS / CENTURY LED LTD / C&S / RASHMI)
-ditto- as per Item No. 56 but of 1 X 10 Watt capacity in aluminium housing
(MAKE : HAVELLS, Model : Lumline Plus / HALONIX, Cat No: HLB-03-10-CW-AL / SURYA, Cat No: SLE BT 10 / JAQUAR, Cat No: LGLZ01X010XC / HPL, Cat No: HLPT51510CW / CROMPTON, Cat No: LDL-10-CDL or equivalent model in PHILIPS / BAJAJ / PANASONIC /CENTURY LED LTD / C&S / RASHMI)
-ditto- as per Item No. 56 but with polycarbonate housing of capacity 1 X 20 Watt
(MAKE : HAVELLS, Model : Lumline / HALONIX, Cat No: HLB-33-20-CW-IP / CROMPTON, Cat No: LCTLN-20-CDL / CENTURY LED LTD, Cat No : BWUL020C / HPL, Cat No: HLPT51820PCGCW / JAQUAR, Cat No: LGLZPCX020XC / SIMOCO, Cat No: SLT54020CB / BAJAJ, Cat No: BCLSB 20 WH or equivalent model in PHILIPS /SURYA /PANASONIC / C&S / RASHMI)
-ditto- as per Item No. 56 but of 1 X 10 Watt capacity in polycarbonate housing
(MAKE : HAVELLS, Model : Lumline / HALONIX, Cat No: HLB-07-10-CW-IP / CROMPTON, Cat No: LCTLN-10-CDL / CENTURY LED LTD, Cat No : BWUL010C / SIMOCO, Cat No: SLT52F10CB / BAJAJ, Cat No: BCLSB 10 NW or equivalent model in PHILIPS / SURYA / PANASONIC / JAQUAR / HPL / C&S / RASHMI )
Supply and Fix in repairs recess mounted LED luminaire suitable for 600 x 600 snap grid ceiling with constant current driver with in built protection against lightning, over voltage & short circuit complete with all accessories with and including 30 Watt LED 6000K (having efficacy of 100 lumen/watt) and including all accessories, mounting frame etc and connecting up with three core flexible copper conductor cable of size 1.5 sqmm (nominal area) complete all as specified and directed.
(MAKE: BAJAJ, Cat No: BZRSQL 30W GZi NW / SURYA, Cat No: SLE DS 30 22R / HALONIX, Cat No: HLFPR22-02-30-CW-R-WC / CROMPTON, Model: LCTLRNE-30-FO-CDL / PANASONIC, Cat No: PBLM05304 or equivalent model in HAVELLS / HPL / JAQUAR / PHILIPS / CENTURY LED LTD / C&S / RASHMI)
Supply and Fix in repairs recess mounted LED flat panel luminaire 300 mm X 300 mm made of die cast aluminium housing with constant current driver with in built protection against lightning, over voltage & short circuit complete with all accessories with and including 18 Watt LED 6000K (having efficacy of 100 lumen/watt) including all accessories, mounting frame etc and connecting up with three core flexible copper conductor cable of size 1.5 sqmm (nominal area) complete all as specified and directed.
(MAKE: BAJAJ, Cat No : BZRSQL 18W WH / SURYA, Cat No: SLE DLR 18W Stellar Pro SQ XX / HALONIX, Cat No: HLFPR11-02-18-CW / CROMPTON, Cat No: LCTLSN-18-CDL / HPL, Model : Sleek Plus Downlight (Square) / or equivalent model in HAVELLS / JAQUAR / PHILIPS / CENTURY LED LTD / PANASONIC / C&S / RASHMI)
Supply and Fix in repairs surface mounted LED luminaire suitable for 600 x 600 snap grid ceiling with constant current driver with in built protection against lightning, over voltage & short circuit complete with all accessories with and including 36 Watt LED 6000K (having efficacy of 100 lumen/watt) and including all accessories, mounting frame etc and connecting up with three core flexible copper conductor cable of size 1.5 sqmm (nominal area) complete all as specified and directed.
(MAKE: BAJAJ, Cat No: BZSSQL 36W LED WH / HALONIX, Cat No: HLFPS22-02-36-CW-R-HL1 / CROMPTON, Cat No: LCTLSNE-30-FO-WW / JAQUAR, Cat No: LSVR01S036SW / CENTURY LED LTD, Model: INFINI or equivalent model in HAVELLS / HPL / PHILIPS / PANASONIC / C&S / RASHMI)
Supply and Fix in repairs recess mounted LED luminaire suitable for 600 x 600 snap grid ceiling with constant current driver with in built protection against lightning, over voltage & short circuit complete with all accessories with and including 36 Watt LED 6000K (having efficacy of 100 lumen/watt) and including all accessories, mounting frame etc and connecting up with three core flexible copper conductor cable of size 1.5 sqmm (nominal area) complete all as specified and directed.
(MAKE: BAJAJ, Model : SKYLUX LED / SURYA, Cat No: SLE DS 36 22R / HALONIX, Cat No: HLFPR22-02-36-CW-R-WC / CROMPTON, Model: AURA I / JAQUAR, Model: ULTIMA / CENTURY LED LTD, Model: INFINI / PANASONIC, Cat No: PBLM01368 or equivalent model in HAVELLS / HPL / PHILIPS / C&S / RASHMI)
Supply and fixing in repairs adjustable bed side LED lamp with clear lens, 3 watt, colour temperature 3000K incl electronic driver and other accessories and necessary electrical connection with suitable size copper wire complete all as specified and directed.
(Make : PHILIPS, Cat No: 48042/30/31 or equivalent model in CROMPTON/ JAQUAR/ HAVELLS/ BAJAJ/ HALONIX/ SURYA / CENTURY LED LTD / HPL / C&S / RASHMI)
S&F in repair picture LED lights with colour temperature 3000K suitable for 10 watt metal and synthetic material lumen 500 Im incl driver and necessary electric connection with suitable size copper wire complete all as per specified and directed.
(Make : PHILIPS, Cat No: 48043/30/86 or equivalent model in CROMPTON/ JAQUAR/ HAVELLS/ BAJAJ/ HALONIX/ SURYA / CENTURY LED LTD / HPL / C&S / RASHMI)
Supply & fixing in repair decorative LED suspended luminaire, pendent type with 1 x 4 watt, E-14 lamp mounted on ceiling duly connected with insulated unsheathed flexible copper wire of suitable size (length not more than 0.50 m) from ceiling rose complete all as specified and directed
(Make: JAQUAR, Cat No: KCH-CHR-MD150031271C or equivalent model in BAJAJ / HALONIX/ HAVELLS / CROMPTON / PHILIPS / SURYA / CENTURY LED LTD / HPL)
S & F in repair LED wall mounted spot focusing light fitting 4 watt, colour temperature 2700K, mounted on wall / ceiling connected with insulated unsheathed flexible copper wire of suitable size (length not exceeding 0.5 m) from ceiling rose complete all as specified and directed.
(Make : Philips, Cat No. 56240/31 or equivalent model in HAVELLS / BAJAJ / WIPRO / CROMPTON / SURYA ROSHNI / C&S)
Repair/maintanance of ceiling fan of any sweep and any height by replacing unserviceable capacitor/ tightening the loose connections if any including testing complete all as directed. (Note: Capacitor of required capacity will be measured & paid under relavent item here-in-after)
Taking down of AC ceiling fan of any sweep & any height and opening the fan and oiling, greasing, rewinding coil and replacement of unserviceable accessories and servicing, complete overhauling and re-assembling and testing complete by hanging in position as directed.
Repair/maintanance of exhaust fan (of any sweep) and opening the fan and oiling, greasing, rewinding coil and replacement of unserviceable accessories and servicing, complete overhauling and re-assembling and testing complete by hanging in position as directed.
Repair/maintanance of wall mounted fan (of any sweep) and opening the fan and oiling, greasing, rewinding coil and replacement of unserviceable accessories and servicing, complete overhauling and re-assembling and testing complete by hanging in position as directed.
Repair/maintanance of pedestal fan (of any sweep) and opening the fan and oiling, greasing, rewinding coil and replacement of unserviceable accessories and servicing, complete overhauling and re-assembling and testing complete by hanging in position as directed.
Supply only capacitor (PVC body) of capacity 2.5 mfd
Supply only capacitor (PVC body) of capacity 3.15 mfd
Supply only capacitor (PVC body) of capacity 4/6 mfd
Supply and fix clamp with buckle for hanging ceiling fan including nuts and bolts and other accessories, suitable for any type of ceiling fan complete all as specified and directed.
Taking down of old Submain wiring any type including batten/ conduit/ casing at any indicated situation complete all as specified and directed.
M&L for sub main wiring with 4 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm as earth continuity conductor drawn through and incl PVC casing-caping of suitable size, surface type complete all as specified and directed. (NOTE : Four runs of single core 10.0 sqmm cable & one run of PVC casing capping shall be measured as one unit)
All as per Srl. Item No. 61 above but with 4 runs of 10.0 Sqmm cable and one run of 10.0 Sqmm as earth continuity conductor in PVC conduit, medium grade (NOTE : Four runs of single core 10.0 sqmm cable & one run of PVC conduit shall be measured as one unit)
All as per Srl. Item No. 61 above but with two runs of 6.0 Sqmm cable and one run of 6.0 Sqmm as earth continuity conductor in PVC casing capping (NOTE : Three runs of single core 6.0 sqmm cable & one run of PVC casing capping shall be measured as one unit)
All as per Srl. Item No. 63 above but with two runs of 6.0 Sqmm cable and one run of 6.0 Sqmm as earth continuity conductor in PVC conduit, medium grade (NOTE : Three runs of single core 6.0 sqmm cable & one run of PVC conduit shall be measured as one unit)
All as per Srl. Item No. 61 above but with two runs of 4.0 Sqmm cable and one run of 4.0 Sqmm as earth continuity conductor in PVC casing capping (NOTE : Three runs of single core 4.0 sqmm cable & one run of PVC casing capping shall be measured as one unit)
All as per Srl. Item No. 65 above but with two runs of 4.0 Sqmm cable and one run of 4.0 Sqmm as earth continuity conductor in PVC conduit, medium grade (NOTE : Three runs of single core 4.0 sqmm cable & one run of PVC conduit shall be measured as one unit)
All as per Srl. Item No. 61 above but with two runs of 2.5 Sqmm cable and one run of 2.5 Sqmm as earth continuity conductor in PVC casing capping (NOTE : Three runs of single core 4.0 sqmm cable & one run of PVC casing capping shall be measured as one unit)
All as per Srl. Item No. 67 above but with two runs of 2.5 Sqmm cable and one run of 2.5 Sqmm as earth continuity conductor in PVC conduit, medium grade (NOTE : Three runs of single core 2.5 sqmm cable & one run of PVC conduit shall be measured as one unit)
Material and labour for cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water tubing or concealed water tubing or concealed conduit wiring etc and making good, cutting not exc 10 cm girth complete all as specified and directed.
Taking down of Old MCB DB any type any size including MCCB/RCCB/MCBs and disconnecting the serviceable MCBs and keeping in safe custody for reuse at site.
S&F SPN DB, IP 43 protection, double door, 240 volts, 4 way complete all as specified and directed.
(MAKE : L&T, Cat No. DBSPN004DD / ABB, Cat No. E-SHC M4 / SCHNEIDER, Cat No. NBKRENSNDD04 / C&S, Cat No; CSDBSPNPDD04 / BCH, Cat No: BCHSPNDD04W / HPL, Cat No: MDBDD04 / HAGER, Cat No: VYS04D / HAVELLS, Cat No: DHDPSHODRW04 or equivalent model in INDO ASIAN (OPTI PRO) / LEGRAND)
Supply and fixing TPN DB, IP 43 protection, double door, 415 volts, 4 way (8+12) complete all as specified and directed.
(MAKE : L&T, Cat No. DBTPN004DD / SCHNEIDER, Cat No. A9HTND04 / HAGER, Cat No: VYT04DH / BCH, Cat No: BCHHTPNDD04W / C&S, Cat No: CSDBTPNHPDD04 /ABB, Cat No: E-SHDB M4 or equivalent model in HAVELLS / INDO ASIAN (OPTI PRO) / HPL / LEGRAND)
Supply and Fix, Double Door, Sheet Metal Enclosure for DBs for mounting of MCB for 240 Volts, 8 way, with 200 Amps rated bus bar, Single Pole & Neutral, complete all as specified and directed.
(MAKE : L&T, Cat No. DBSPN008DD / ABB, Cat No. E-SHC M 8 / SCHNEIDER, Cat No. A9HSND08 / HAGER, Cat No: VYS08D / C&S, Cat No: CSDBSPNPDD08 / BCH, Cat No: BCHSPNDD08W / HPL, Cat No: MDBDD08 / HAVELLS, Cat No: DHDPSHODRW08 or equivalent model in INDO ASIAN (OPTI PRO) / LEGRAND)
Refixing of MCB DB any type or any size and necessary electrical connections as directed by Engr-in-Charge.
NOTE FOR ITEM NO. 71 to 74 :- (1) Incoming MCCB/RCCB/MCB and outgoing MCBs shall be measured and paid seperately as "Supply Only". (2) Quoted rate is deemed to be inclusive of blanking plate for slots remaining blank after fixing of MCBs. (3) DB, MCCB, RCCB & MCB shall be of the same manufacturer.
Supply only MCB, 'C' series, TPN, 415 volts, 63 Amps, breaking capacity 10KA complete all as specified and directed.
Supply only MCB, 'C' series, SPN, 32 Amps, breaking capacity 10KA complete all as specified and directed.
Supply only MCB, 'C' series, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed.
Labour only for taking down and fixing of new/serviceable RCCBs / MCBs any size or any type including electrical connections in existing DBs complete all as specified and directed. (NOTE :- RCCB/MCB shall be measured and paid seperately as "Supply Only").
S&F in repairs PVC casing/caping of size 25 mm with all accessories all as directed by Engr-in- charge .
S&F in repairs PVC casing/caping of size 20 mm with all accessories all as directed by Engr-in- charge .
S&F in repairs GI tubing medium grade of size 15 mm dia incl painting and making hole for extension of fan hook in high roof ceiling complete all as specified and directed.
S&F in repair LED driver for 2'x2' LED ceiling light fitting 230 Volt 30 watt - 40 watt complete all as specified and as directed.
S&F in repair LED driver for LED ceiling light fitting 230 Volt 18 watt - 28 watt complete all as specified and as directed.
S&F in repair LED driver for LED ceiling light fitting 230 Volt 05 watt - 15 watt complete all as specified and as directed.
S&F in repair LED driver for LED strip light, 230 Volt 5 W complete all as specified and as directed.
Supply and fixing in repair MODULAR MCB protected power unit with one 25 Amps socket with 3 pin plug top and including 01 No MCB, DP, and starter 25 Amps ratings with six module plate and flush metal GI box and electrically connected complete all as specified and directed.
(MAKE : HAVELLS, Cat No. DHDUCDP0253025 / NORTH WEST, Cat No: ACPU6M-BT or equivalent model in ABB / INDO ASIAN / HAGER / ANCHOR / LEGRAND /BCH / HPL)
Supply and fixing in repairs single pole enclosure with two pin and earth plug and socket complete with one SP MCB, 20 Amps, 'C' Curve, 10 KA including all accesories complete all as specified and directed.
(MAKE OF ENCLOSURE: LEGRAND, Cat No. 5078 10 / L&T, Cat No. DBMPS120SD / SCHNEIDER, Cat No: A9HMS220 / ABB, Cat No. NSYN8690SGKSP20 / C&S, Cat No: CSDBPSSPN020 / BCH, Cat No: BCHPSDBSPN20 / HPL, Cat No: MDBSP20 / HAGER, Cat No: VYA220Cor equivalent model in Havells / Indo Asian )
(NOTE : Enclosure & MCB shall be same manufacturer)
Materials and Labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized steel earth wire 4 mm dia (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
Supply and fixing cable tray of size 100 X 100 mm with all accessories complete all as specified and directed.
SCHEDULE 'A' PART-II (AC & REFRIGERATION) Taking down for servicing of split type AC 1.5TR Capacity including cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner Or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc., changing electrical connections if required and keeping the AC unit in satisfactory working condition after necessary servicing and refixing the same in existing position complete all specified and as directed by Engineer-in-Charge.
Taking down for servicing of split type AC 2.0TR Capacity including cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc., changing electrical connections and keeping the AC unit in satisfactory working condition after necessary servicing and refixing the same in existing position complete all specified and as directed by Engineer-in-Charge.
Taking down for servicing of Window type AC 1.5TR Capacity including cleaning of cooling coil, air filters, condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, remote control unit including PCB, fan, blower, etc, changing electrical connections and keeping the AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified and as directed by Engineer-in-Charge.
Taking down for servicing of Window type AC 2.0 TR Capacity including cleaning of cooling coil, air filters, condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, remote control unit including PCB, fan, blower, etc, changing electrical connections and keeping the AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified and directed by Engineer-in-Charge.
Supply and fix in repairs of running capacitor 36 Mfd capacity in metal container pin type all as specified and directed.
Supply and fix in repairs of running capacitor 50±4 Mfd capacity in metal container pin type all as specified and directed.
Supply and fix in repairs of running capacitor 50±6 Mfd capacity in metal container pin type all as specified and directed.
Supply and fix in repairs starting relay for 1.5 TR compressor all as specified and directed.
Supply and fix in repairs starting relay for 2 TR compressor all as specified and directed.
Supply and fix in repairs suction copper pipe line heavy duty 1/2'' dia and flair nuts from indoor to outdoor unit of split AC 1.5 /2 TR capacity all as specified and directed.
Supply and fix in repairs discharge copper pipe line heavy duty 1/4" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity all as specified and directed.
Supply and fix in repairs discharge copper pipe line heavy duty 5/8" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity all as specified and directed.
Supply and fix in repairs discharge copper pipe line heavy duty 3/8" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity all as specified and directed.
Supply and fix in repairs PVC pipe nylon imbraided 15 mm dia for condenser water drain fitted with clamps/ concealed in wall all as specified and directed.
S&F Foam insulation for copper tubing of size 1/2'' dia complete all as specifed and directed.
S&F Foam insulation for copper tubing of size 5/8'' dia complete all as specifed and directed.
S&F Foam insulation for copper tubing of size 1/4'' dia complete all as specifed and directed.
S&F Foam insulation for copper tubing of size 3/8'' dia complete all as specifed and directed.
Dismantling of defective condensing unit of split type AC of 1.5 TR capacity and supply & fixing new condensing unit complete with condensing copper coil, coil frame, wiring kit and running capacitor, relay condensing motor with blade complete all as specified and directed.
Dismantling of defective condensing unit of split type AC of 2 TR capacity and supply & fixing new condensing unit complete with condensing copper coil, coil frame, wiring kit and running capacity, relay condensing motor with blade complete all as specified and directed.
Dismantling of burnt blower motor of 1.5 TR split AC (indoor unit) and supply & fixing blower motor of same manufacturer of AC. Make of AC Carrier/Voltas /Blue star as per sample complete all as specified and directed.
Dismantling of burnt blower motor of 2 TR split AC (indoor unit) and supply & fixing blower motor of same manufacturer of AC. Make of AC Carrier/Voltas /Blue star/LG/Samsung as per sample complete all as specified and directed.
Dismantling of burnt swing motor of 1.5 TR split AC (indoor unit) and supply & fixing blower motor of same manufacturer of AC. Make of AC Carrier/Voltas /Blue star/LG/Samsung as per sample complete all as specified and directed.
Dismantling of burnt swing motor of 2 TR split AC (indoor unit) and supply & fixing blower motor of same manufacturer of AC. Make of AC Carrier/Voltas /Blue star/LG/Samsung as per sample complete all as specified and directed.
Supply and charging (Top up) the AC unit of 1.5 TR /2 TR split type AC unit with Refrigerant Gas compatible to R-22 type in required quatity complete all as specified and directed.
Supply and charging (Top up) the AC unit of 1.5 TR /2 TR split type AC unit with Refrigerant Gas compatible to R-134 type in required quatity complete all as specified and directed.
Supply and charging the AC unit of 1.5/2/2.5/3.5/4.5 TR split type AC unit with Nitrogen Gas for detecting of leakages required as per site quatity complete all as specified and directed.
Supply and fixed in repairs of suction valve size 1/2" complete all as specified and directed .
Supply and fixed in repairs of discharge valve size 1/4" complete all as specified and directed.
Supply and fixed in repairs of suction valve size 5/8" complete all as specified and directed .
Supply and fixed in repairs of discharge valve size 3/8" complete all as specified and directed.
Supply and fixed in repairs of air filter made out of Nylon suitable for 1.5 TR capacity split AC of any Make and model complete all as specified and directed.
Supply and fixed in repairs of air filter made out of Nylon suitable for 2 TR capacity split AC of any Make and model complete all as specified and directed.
Dismantling of un-serviceable cooling coil unit any type any size of indoor unit of split type Air Conditioner of capacity 1.5 TR by cutting the suction line and discharge line, and providing new cooling copper coil unit of indoor unit (of same capacity), coil frame, wiring kit and running capacitor, relay , swing motor including testing on completion complete all as directed by the Engr-in-Charge.
Dismantling of un-serviceable cooling coil any type any size of indoor unit of split type Air Conditioner of capacity 2.0 TR by cutting the suction line and discharge line, and providing new cooling copper coil of indoor unit (of same capacity), coil frame, wiring kit and running capacitor, relay , swing motor including testing on completion complete all as directed by the Engr-in-Charge.
S&F in repair PCB kit complete for Window/Split type Air Conditioner 1.5/2 TR of any make and capacity complete all as specified and as directed
M&L for carrying out pressure leak test of split ACs 1.5 / 2.0 TR capacities by Nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by welding or brazing of cooling unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe including gas charging transporting & carrying out Tools and Plant required at site complete all as specified and directed.
M&L for carrying out pressure leak test of split ACs 2.0 TR capacities by Nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by welding or brazing of cooling unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe including gas charging transporting & carrying out Tools and Plant required at site complete all as specified and directed.
M&L carrying out pressure leak test of 1.5 TR window AC by Nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by welding or brazing of cooling unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe including gas charging transporting & carrying out Tools and Plant required at site complete all as specified and directed.
S&F PVC insulated and PVC round sheathed copper conductor (flexible) industrial cable, (FRLS) 1100 Volts, conforming to IS 694 of size 2.5 sqmm 3 Core connecting electrical equipments with terminal lugs / clips as per site requirement, complete all as specified and as directed.
S&F Bottom tray of 1.5 ton /2 ton capacity window type AC made out of 14 SWG mild steel sheet Including painting with two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
M&L Soldering of Copper pipe with soldering stick in position of any size and location for arresting leakages complete all as specified and as directed.
Taking out existing out door unit of split type Air Conditioner including refrigerant lines and electrical connections (of capacity 1.5 TR / 2.0 TR) and re-fixing at new location as directed including providing PCC platform of size 900 mm x 600 mm x 200 mm (1:4:8) ) type D-2 using 40 mm graded crushed stone aggregate) alongwith fixing arrangement with nuts and bolts complete all as directed by the Engr-in-Charge. (Note :- Excess requirement of refrigerant pipe line, electric connection cable , drain pipe topping up of refrigerant gas shall be measured and paid separately under relevant item of this schedule)
Taking out existing indoor unit of split type Air Conditioner including refrigerant lines and electrical connections of capacity 1.5 TR / 2.0 TR) and re-fixing at new location alongwith fixing arrangement with screwed on wooden gutka on wall surface and making good the disturbed surfaces complete all as directed by the Engr-in-Charge. (Note :- Excess requirement of refrigerant pipe line, electric connection cable ,drain pipe and topping up of refrigerant gas to be measured and paid separately under relevant item of this schedule)
S&F Compressor sealed unit for Split type Air Conditioner of capacity 1.5 ton compressor by removing of old burnt compressor and fixing as per manufacturer instruction including providing connections of gas line, fixing of copper tubes of suitable sizes, hand shut off valves, relays, starting and running capacitors etc complete all as specified and directed. Note :- Charging of gas refrigerant will be paid and measured separately
S&F Compressor sealed unit for Split type Air Conditioner of capacity 2 ton compressor by removing of old burnt compressor and fixing as per manufacturer instruction including providing connections of gas line, fixing of copper tubes of suitable sizes, hand shut off valves, relays, starting and running capacitors etc complete all as specified and directed. Note :- Charging of gas refrigerant will be paid and measured separately
S&F Condenser fan blade suitable for 1.5 TR capacity Split type Air Conditioner including taking out old one complete all as specified and as directed.
S&F Condenser fan blade suitable for 2.0 TR capacity Split type Air Conditioner including taking out old one complete all as specified and as directed.
S&F Roller runner, suitable for 1.5 TR capacity Split type Air Conditioner including taking out old one complete all as specified and as directed.
S&F Roller runner, suitable for 2.0 TR capacity Split type Air Conditioner including taking out old one complete all as specified and as directed.
Taking down indoor unit of 1.5 TR capacity by preserving the existing gas in outdoor unit, checking and overhauling the complete indoor unit part by part and refixing at same position including testing complete all as directed by the Engr-in-Charge. (Note:-The repair of indoor motor, filters and roller runner to be measured and paid separately under relevant item of this BOQ)
Taking down indoor unit of 2.0 TR capacity by preserving the existing gas in outdoor unit replacing the unserviceable GI bracket and refixing at same position including testing complete all as directed by the Engr-in-Charge.
Taking down unserviceable indoor cooling coil motor of 1.5 TR / 2.0 TR capacity and repairing & refixing complete testing and running all as directed by the Engr-in-Charge.
Taking down out door unit of 1.5TR/2.0 TR capacity for removing unserviceable angle iron bracket and S&F Fabrication of angle iron stand of size 50x50x6mm suitable for fixing out door unit with two coats synthetic enamel paint over a coat of primer and refixing the out door unit connection the suction and discharge line complete testing complete all as specified and as directed.
S&F Compressor sealed unit of Window type Air Conditioner of capacity 1.5 TR by removing of old burnt compressor and fixing as per manufacturer instruction including providing connections of gas line, fixing of copper tubes of suitable sizes complete all as directed by the Engr-in-Charge.
Taking down window type Air Conditioner, shifting and installation of same at other location within two Km radius including cutting and opening of existing brick work and making good dismantled portion in cement mortar 1:3 as required in exc. Half Brick but not exc. one brick thick Walls and providing three coats white wash on finished surface complete all as specified and as directed.
M&L Cutting openings, through brick wall for fixing of window type Air Conditioner including necessary wooden frame work not less than 2" by 2" thick size as per AC model including fair finish of side walls in cement mortar (1:6) with three coats white wash, cleaning and stacking bricks removing surplus serviceable bricks, hard-core etc to store and rubbish not exc 50m complete all as specified and as directed.
S&F in repair MCB, TPN, 63 A, 415 Volts, 10 kA, C Curve ncluding necessary incoming and out going electric connection with suitable size of copper lugs etc.complete all as specified and as directed.
S&F in repair Single phase preventer 415 type SPPR (Auto reset 540 volts un balance) complete all as specified and as directed.
Supply and fix in repair power contactor 2 pole, coil voltage 230 Volts of capacity 25 Amps Complete all as specified and directed.
Supply and fix in repair power contactor 3 pole, coil voltage 415 Volts of capacity 32 Amps Complete all as specified and as directed.
Supply and fix in repair remote control hand set for 2.0 TR capacity split AC complete all as specified and as directed.
Supply and fix in repair remote control hand set for 1.5 TR capacity split AC complete all as specified and as directed.
Supply and fix in repair remote control hand set make suitable for 2.0TR capacity window type AC complete all as specified and as directed.
M&L for servicing including cleaning of condenser coil fins with mild detergent, cleaning of indoor unit and descaling of condensor coil for Vertical type 3 phase Air Conditioner, of any make/capacity after taking down the outdoor unit and refixing in the existing location or any where and replacement of insulation of suction & discharge line complete all as specified and as directed.
S&F in repair PCB kit complete for Vertical type Air Conditioner of any make and capacity complete all as specified and as directed.
S&F Compressor sealed unit for Vertical type Air Conditioner of capacity 3.0 TR by removing of old burnt compressor and fixing as per manufacturer instruction complete all as specified and as directed. Note :- Charging of Refrigerant gas will be measured and paid separately
Dismantling of defective water cooler storage type of 40 ltrs capacity including transportation to workshop and back for thorough checking/including all accessories and components re-assembling the same after repair/ replacement of defective accessories/components including testing complete all as specified and directed. (NOTE: Spares to be replaced shall be measured as "Supply Only". Quoted rate shall be deemed to be inclusive of the labour cost for fixing of the spares.)
Supply only Aluminium fan blade for blower motor for water cooler of capacity 40 ltrs complete all as specified and directed
Supply only PCB and Wiring set complete consisting of PVC insulated cable wiring stranded copper conductor connecting clips etc suitable for water cooler 40 ltrs complete all as specified and directed
Supply only Over load protector for compressor suitable for water cooler of capacity 40 Ltrs complete all as specified and directed
Supply only Self closing bib tap/push tap 15mm dia chromium plated steel suitable for water cooler 40 ltr/hrs capacity complete all as specified and directed.
Supply only 15 mm dia Float valve PVC complete with all accessories complete all as specified and directed
Supply only new compressor suitable for 40/40 ltr/hrs storage capacity water cooler including testing incl taking down existing compressor complete all as specified and directed. (NOTE: Recharging of gas will be measured and paid separately).
Supply and fix in repair Low density polyethylene pipe connection, comprising of 15 mm dia 450 mm long having PTMT union at each end complete all as specified and directed.
(MAKE : PRAYAG, Cat No. 323 / POLYTUF, Cat No. 4003 or equivalent model in SHAKTI / JEXON / CERA)
Supply & Fix in repair 15 mm bore Stop cock brass both end screwed complete all as specified and directed
SCHEDULE 'A' PART-III ( EXTERNAL ELECTRIFICATION) Taking out unserviceable LT panel board / FEEDER PILLER box (of any size) and Supply, install, commissioning and testing of outdoor type LT panel board, cubical type, dust and vermin proof, made out of 3.15 mm thick CRCA sheet of size 1200 mm x 900 mm x 500 mm, fabricated in a CPRI approved factory, with front and back openable door (with locking arrangement) and making compartment for each MCCB/change over switch separately, duly painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer inclusive of aluminium bus bars, for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper lugs and copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland),and two numbers Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with angle iron frame with base 50X 50X 6 mmwith legs not more then 60 cm including grouting with P C C complete including eadrthing all as directed by the Engr-in-Charge including supply and fixing of the following accessories :-
Aluminium bus bar 50 mm x 6 mm of adequate length - 4 Nos
LED indicating Lamp with holder for main & standby supply indicating RYB (Set of three) - 01 Set
MCCB (Incoming) 400 Amps, 4 Pole, 36 KA, Ics= 100% of Icu - 01 No (Make: L&T, Cat No - CM98403OOROOG / LEGRAND, Cat No: 4220 07 / HAVELLS, Cat No: IHBA9EMF0400 / C&S, Cat No: CSE3M400ATM4P_400 or equivalent model in SCHNEIDER / ABB / INDO ASIAN (OPTI POWER) / HAGER)
MCCB (Outgoing) 100 Amps, 4 Pole, 36 KA, Ics= 100% of Icu - 04 Nos (Make : L&T, Cat No - CM97919OOK2OG/ LEGRAND, Cat No: 4200 95 / HAVELLS, Cat No: IHBA6ELF0100 / C&S, Cat No: CSCN124TM1004P or equivalent model in SCHNEIDER / ABB / INDO ASIAN (OPTI POWER) / HAGER)
Note:-(i) All incoming and out going cables, duly thimble along with suitable size of brass cable glands, to be connected to accessories. (ii) All MCCB & Changeover to be connected internally with suitable size of copper strip.
Supply and fix (in replacement) MCCB, 4 pole, 25 KA with thermal maganetic release range, 250 Amps, Ics=100% of Icu with all accessories incl taking down existing MCCB complete all as specified and directed.
(Make: L&T, Type DN1-250C, Cat No - CM90642OOPO/ LEGRAND, Cat No: 4202 19 / C&S, Cat No: CSE2M250ATM4P-250 / HAVELLS, Cat No: IHD2HOBF0250 or equivalent model in SCHNEIDER / ABB / INDO ASIAN (OPTI POWER) / HAGER)
Supply and fix (in replacement) MCCB, 4 pole, 25 KA with thermal maganetic release range, 160 Amps, Ics=100% of Icu with all accessories incl taking down existing MCCB complete all as specified and directed.
(Make: L&T, Type DN1-250C, Cat No - CM90642OOMO / LEGRAND, Cat No: 4200 57 /C&S, Cat No: CSE2M250ATM4P-160 / HAVELLS, Cat No: IHD2HOBF0160 or equivalent model in SCHNEIDER / ABB / INDO ASIAN (OPTI POWER) / HAGER)
Supply and fix in replacement LED Post Top luminaire, 45 Watts, made in die - cast aluminium with with decorative clear opal acrylic diffuser, inbuilt driver & IP 65 protection incl all accessories and necessary electric connection with suitable size copper wire incl taking down existing luminaire complete all as specified and directed.
(Make: BAJAJ, Cat No: BGCT W4 LED WW / HALONIX, Cat No: HLPT-04-45-CW or equivalent model in HAVELLS / CROMPTON / PHILIPS / SURYA / HPL / MAGIK)
GHOSH ENTERPRISE
IDEAL TRADERS
JOY RAM ENTERPRISE
MS AP CONSTRUTION AND CO
M A ENTERPRISES
RAY STANDARD ENGG CO.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .