Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹60.3 LAccepted-AOC | ₹60.3 L Quoted ₹60.4 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹64.4 L+₹4.1 L (6.75%)Rejected-Finance NH 17 MAIN ROAD BINAGA BAZAR KARWAR 581307 | KARWAR | UTTARA KANNADA | KARNATAKA | 581307 | ₹64.4 L+₹4.1 L (6.75%) | L2 | Rejected-Finance HIGHER BIDDER |
Tender Value
Refer Docs
EMD Value
₹1.2 L
Closing Date
1 Mar 2021, 6:00 pmClosed
SH A K SINGH SE CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
MANNING AND OPERATION INCLUDING REPAIR MAINTENANCE OF WATER SUPPLY INSTALLATION AT BAITHKOL, HYLAND, NEW MAP QTRS ARGA AND LITTLE BINAGA, SANKRUBAGH INCLUDING DG SET AT BAITHKOL UNDER GE SB KARWAR
2021_MES_416122_1
85372/E8
Open Tender
Civil Works
Item Rate
334 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹1,000
Yes
GE (SB) KARWAR
₹1.2 L
Yes
24 Mar 2021
25 Jan 2021
3 Mar 2021
25 Jan 2021
1 Mar 2021
15 Feb 2021
Amount
Manning and Operation of water supply installation at Baithkol in 03 (three) shifts of 8 hours each on all days including Sundays and holidays including minor maintenance /checks all as specified and as directed. The installation comprises of following equipments:- (i) Centrifugal pump set 7.5 HP - 02 Nos (ii) Submersible pump set 7.5 HP - 01 No (iii) DG set 250 KVA - 01 No (v) LT Panel -02 Nos
Manning and Operation of water supply installation at Hyland in 02 (two) shifts of 8 hours each on all days including Sundays and holidays including minor maintenance /checks all as specified and as directed. The installation comprises of following equipments:- (i) Monoblock pump set 2 HP - 01 No (ii) Monoblock pump set 1 HP - 01 No (iii) DG set 12.5 KVA - 01 No
Manning and Operation of water supply installation at DDG (PI) in 01 (one) shift of 8 hours each on all days including Sundays and holidays including minor maintenance / checks all as specified and as directed. The installation comprises of following equipments:- (i) Monoblock Pump set 1 HP - 01 No (ii) DG Set 25 KVA-01 No
Manning and Operation of water supply installation at MAP Ph-II Little Binaga in 03 (three) shifts of 8 hours each on all days including Sundays and holidays including minor maintenance /checks all as specified and as directed. The installation comprises of following equipments:- (i) Centrifugal pump set 30 HP - 02 Nos (Make- Kirloskar) (ii) Diesel Engine Driven pump set 72 HP -01 No (Make- Kirloskar) (iii) Jockey pump set 7.5 HP -01 No (Make- Kirloskar) (iv) Centrifugal Pump Set 50 HP for Fire Fighting-01 No (Make- Spectrum) (v) LT Panel -01 No
Manning and Operation of water supply installation at MAP Ph-II Arga (Kadamba Vanam) in 03 (three) shifts of 8 hours each on all days including Sundays and holidays including minor maintenance /checks all as specified and as directed. The installation comprises of following equipment:- (i) Centrifugal pump set 30 HP - 02 Nos (Make- Kirloskar) (ii) LT Panel -01 No
Manning and Operation of water supply installation at Sankrubagh in 03 (three) shifts of 8 hours each on all days including Sundays and holidays including minor maintenance / checks all as specified and as directed. The installation comprises of following equipments:- (i) Centrifugal Pump Set 5 HP - 04 Nos (ii) Standby DG Set 15 KVA - 01 No (iii) Centrifugal Pump Set 10 HP -2 Nos (iv) LT Panel -01 No
Notes for SI item Nos 1 to 6 :- (a) Contractor shall employ one fitter general mechanic/ electrician having minimum ITI qualification from Govt recognised institute with adequate knowledge & minimum 2 years experience in maintenance & operation of electric supply/water supply/fire fighting installation for each shift of 08 hours. The operator must competent to carry out the minor repair/maintenance all as specified and as directed.
(b) Each shift duration shall be 8 hours & duty timing shall be decided by Engineer-In-Charge. (c) The unit rate quoted shall be deemed to include for cost of labour for daily routine maintenance for trouble free functioning of installation. (d) Checking/rectification of leakage of water. (e) Checking/rectification of loose connections. (f) The unit rate quoted shall deemed include for maintenance of earth pits, cutting & removing of vegetation and upkeep of the surrounding area, all around the bldg upto 6 mtr from the plinth protection all as specified and as directed. In case of failure, a penalty of Rs 1000/- per month per plant/pump house shall be levied and recovered from dues. (g) In case of any abnormal noise/complaint the plant should be put off same should be brought to the notice of Engineer-in-Charge. (h) The operator shall check loose connection, water leakage and inform Engineer-in-Charge/JE regularly.
(j) The operator shall check the gland, vibration, nut bolts daily & tightening up as and when required. (k) The operator shall check level of distilled water in battery & top up as and when required. The quoted rate shall deemed to include the cost of distilled water. (l) Check battery terminals, if found loose, tighten it property. (m) The operator employed by the contractor shall be capable of carrying out minor repair maintenance & should have well experience in electrical panel, motor, pump set & fire fightings field etc. (n) The quoted rate is deemed to be inclusive of cotton waste, cleaning material etc & contractor shall ensure general area cleanliness and upkeep of the installation on daily basis. (o) The quoted rate is deemed to be inclusive of tools & testing instruments required for operation & maintenance of LT panel, pump set, starter & fire fighting equipments etc. (p) The rate quoted shall deemed to be inclusive of safety gear & required tools for minor maintenance. The contractor shall provide 02 Pairs of Gum Boot & 02 Pairs of Hand Gloves. In case of failure to provide tools kit & safety kit a penalty of Rs 3000/- shall be recovered and levied per Operator.
(q) Power supply for operation of electric equipments, pump sets & fire fighting equipment shall be made available by department free of cost. (r) Fuel for operation of diesel engine driven pump sets shall be provided through issue voucher. (s) The contractor shall provide 02 uniforms to each operator and design of uniform shall be got approved from GE. In case of failure, a penalty of Rs 100/- per day per Operator shall be levied and recovered from dues. (t) In case of failure due to absence of operative staff, the contractor shall be liable to pay compensation of Rs.1000/- or at twice the cost of a day’s manning & operation derived from pro rata rate of Sch ‘A’ quoted rates whichever is higher (v) The Contractor shall maintain proper records of all kinds of daily, weekly, monthly, quarterly, half yearly and yearly or whatsoever maintenance is carried out during contract period in a binded book / register and shall obtain the signature of Engineer-in-Charge every fortnightly. The quoted rate is deemed to be inclusive of binded book/register.
(x) It is responsibility of contractor to deposit the employees provident fund (EPF) to the concerned authority as per the prevailing scales as laid down by the Ministry of labour for all Electrician/operator/helper (as applicable) and necessary proof to this regard shall be submitted to Engineer-in-Charge for verification and records. The quoted rate shall be deemed to be included of above provisions. In case contractor fails to produce the proof of EPF, he shall be liable for action as deemed fit. Decision of GE in this regard shall be final and binding. (y) The contractor shall maintain all the registers under various labour law rules, 2017 and shall be produced to GE and as well as officers detailed by labour department.
(z) The rates quoted shall be inclusive of all taxes ,cess, levies etc as applicable including GST (aa) The prevailing rate,wage,contribution etc shall be as applicable as on the bid submission end date. (ab) In view of COVID-19 alerts various restrictive instructions issued concerned authorities from time to time. Hence additional precautions essential for the work shall be taken by the contractor by way of provisioning of masks, hand sanitizers, gloves etc to workmen and all local instructions issued by the Concerned Authorities and Station Authorities shall be complied with all relevant safety precautions covered under Model Rules for the protection of health and sanitary arrangement for workmen (Annexure ‘C’) of IAFW-2249) shall be strictly followed. Nothing extra is admissible on this account (ac) The contractor shall also deploy additional man power as relief against weekly off,leave,holidays etc all as per existing Labour Act and shall substitute the operator accordingly for which no extra payment admissible. The unit rate quoted against items in Schedule ‘A’/BOQ shall be inclusive of this provision also. (ad) The contractor shall pay the wages to the operator through e-payment i.e Aadhar linked bank accounts and Credit to their bank account. The wages shall not be less than prevailing minimum wages fixed by state Govt or central Govt whichever is more.
Supply only calcium based granular disinfectant having chlorine concentration 65%-70% all as specified and as ddirected.
Supply only alum lump grade 1st quality all as specified and as directed.
Supply only engine oil grade 15W-40 for routine maintenance and topping up all as specified and as ddirected.
M & L for cleaning RCC underground sumps/ground level reservoirs/ hill top reservoirs of following capacities including mouths of connected pipes etc by dewatering the sumps by using a portable pumpset of suitable capacity, removing all sludge/mud/dirt etc manually, pouring fresh water in sump through another pumpset, rinsing and dewatering the sumps including removing sludge/dirt particle manually, wash the sump using fresh water mixed with sodium hypochlorite & drain out water by a pumpset and finally applying one coat of antibacterial sodium hypochlorite solution to inner surface & including cost of writing letters as "Tank cleaned on (____ Date)" using synthetic enamel paint outside the wall of RCC water tanks in prescribed format complete all as specified and as directed.
(a) 45,000 litre capacity
(b) 90,000 litre capacity
(c) 50,000 litre Fire Tank
(d) 60,000 litre GLR
(e) 1,50,000 litre GLR/HTR
(f) 10,00,000 litre GLR/HTR
Dismantling electric motor from the centrifugal pumpset/monoblock/submersible of any make, 3 phase 415V of following capacities, opening the motor for rewinding using super enamelled copper wire of suitable gauge to match with the existing winding including varnishing & drying and re-assembling the motor, connecting with pumpset with proper alignment and testing complete through authorised service engineer all as specified and as directed for the following capacity :-
M&L for overhauling of centrifugal pump set of capacity 7.5 HP, 3 phase 415 volts by opening up the pumpset, cleaning inside & outside thoroughly, including replacement of gland packing, rubber insertion, replacement of bearings - 2 Nos (DE/NDE) and testing complete all as specified and as directed.
M&L for overhauling of centrifugal pump sets / vertical turbine pumps 3 phase 415 volts of following capacities by opening up the pumpset, cleaning inside & outside thoroughly, including replacement of gland packing, rubber insertion, replacement of bearings - 2 Nos (DE/NDE) and testing complete all as specified and as directed :-
S&F in repairs of new battery of 12 volts 180 AH battery all as specified and as directed.
M&L for preparation of existing painted surfaces of motor, pump, water pipe lines etc at Baithkol pump house and filling of cavities etc and applying one coat of synthetic enamel paint using spray gun/machine as per colour code including writing SM & MES No on pump & motor, indication marking etc complete all as specified and as directed.
S&F in repairs bearing No : 6309 ZZ all as specified and as directed.
S&F in repairs bearing No : 6314 ZZ all as specified and as directed.
S&F in repairs gland packing for pump of size 7.5 HP as per site requirement complete all as specified and as directed.
S&F in repairs gland packing for pump of size 5-30 HP as per site requirement complete all as specified and as directed.
Dismantling and taking out carefully defective spindle from sluice valve of size 80 mm dia and removing the old gate stud by grinding and making it to a shape by brass welding and turning & polishing, greasing, servicing as per original gate stud and refixing the same at position and testing complete all as specified and as directed.
All as per Item No 20 here-in-before, but of size 100 mm dia all as specified and as directed.
All as per Item No 20 here-in-before, but of size 150 mm dia all as specified and as directed.
Supply only grease for pump bearings all as specified and as directed.
S&F in repairs mild steel nuts, bolts, washer & flange etc all as specified and as directed.
S&F in repairs cast iron sluice valve of size 80 mm flanged PN-1.6 ISI conforming to IS :14846 hand wheel operated, stainless steel stem with gun metal parts flanged driller to IS: 1538 non rising stem PN-1.6 all as specified and as directed.
All as per Item No 25 here-in-before, but of size 100 mm dia all as specified and as directed.
All as per Item No 25 here-in-before, but of size 150 mm dia all as specified and as directed.
S&F in repair 80 mm dia water meter CI body flanged and drilled both ends confirming to IS 2373/81 mechanical driven straight reading including 80 mm dia CI stainer all as specified and as directed.
S&F in repairs of oil filter suitable for DG sets of 250 KVA all as specified and as directed.
S&F in repairs of fuel filter suitable for DG sets of 250 KVA all as specified and as directed.
S&F in repairs following spare parts suitable for 250 KVA DG Sets all as specified and as directed.
(a) V-belt (Part No 3058383)
(b) Hose clamp (Part No:43828 D)
S&F in repairs of carbon brushes for alternator of 250 KVA Gen set all as specified and as directed.
S&F in repair MCCB 100 Amps rupturing capacity 25 KA 4 Pole 415 volts AC with adjustable thermal setting complete all as specified and as directed.
S&F in repair MCCB 160 Amps rupturing capacity 25 KA 4 Pole 415 volts AC with adjustable thermal setting complete all as specified and as directed.
S&F in repairs MCB TPN, 50 to 63 Amps, ''C'' series 415 Volts, 3 phase, 10 KA breaking capacity of complete all as specified and as directed.
S&F in repairs MCB SPN, 6 to 32 Amps, ''C'' series 230 Volts, single phase, 10 KA breaking capacity complete all as specified and as directed.
M&L for cleaning the pressure sand filters following capacity installed at various pump house at Naval Base Karwar by opening up the inspection covers, removing the existing filter media, cleaning thoroughly and refilling the same and toping up the deficient filter media of required quantity and fixing back the covers including replacement of existing unserviceable rubber gasket all as specified and as directed. Note : Filter media used for toping up shall be measured and paid separately as "Supply Only".
(a) 300 Cum/Hr
(b) 30 Cum/Hr
Supply only granular fine pebbles suitable for filter media of pressure sand water filters installed at various pump house at Naval Base Karwar, granular fine pebbles should be free from all types of salts, alkaline materials, minerals, silts, impurities etc complete all as specified and as directed.
Supply only quartz coarse sand suitable for filter media of pressure sand water filters installed at various pump house at Naval Base Karwar, quartz coarse sand should be free from all types of salts, alkaline materials, minerals, silts, impurities etc complete all as specified and as directed.
ANKIT SHIP REPAIRERS AND SUPPLIERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .