| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.6 LAccepted-AOC AT PO DAKRA KHALARI DIST RANCHI JHARKHAND PIN 829210 | RANCHI | JHARKHAND | 829210 | L1 | Accepted-AOC Techno commercially acceptable and is also the lowest bidder. | |
| 2 | Rejected-Technical AT PO DAKRA KHALARI DIST RANCHI JHARKHAND PIN 829210 | RANCHI | JHARKHAND | 829210 | - | Rejected-Technical Not uploaded all documents as per clauses of NIT | |
| 3 | Rejected-Technical 5 ESWARAN KOVIL STREET PSG NAGAR IN AVALPOONDURAI TOWN PANCHAYAT ERODE DISTRICT | ERODE | TAMIL NADU | 638001 | - | Rejected-Technical Not uploaded all documents as per Clauses of NIT |
Tender Value
₹3.9 L
EMD Value
₹4,800
Closing Date
7 Oct 2024, 5:00 pmClosed
Project Engineer(EnM) Rohini OCP, NK Area, CCL
Office of The Project Officer, EnM Department, Rohini Project, N.K. Area, CCL. P/O- Tumang Dist- Ranchi (Jharkhand)
Lowering and Re-laying of power cables in trenches with installation of main switches, earth pits along with required accessories at Rohini Main Sub-station (2X3MVA, 11kV/3.3kV), under Rohini Project, NK Area.
2024_CCL_318282_1
PE(EnM)/RH/eNIT/2024-25/05
Open Tender
Electrical and Maintenance Works
Item Rate
14 days
Rohini Project, NK Area, CCL
Please refer Tender documents.
5 documents required · 5 mandatory
₹4,800
28 Oct 2024
27 Sept 2024
8 Oct 2024
28 Sept 2024
7 Oct 2024
28 Sept 2024
28 Sept 2024 - 3 Oct 2024
Amount
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. 70 sqmm
Supplying, installing, testing and commissioning of following capacity TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required. 63A TPN
Supplying, installing, testing and commissioning of following capacity TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required. 200A TPN
Supplying, installing, testing and commissioning of following capacity end feed unit made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, brass compression gland, connections, earthing etc. as required. 800A TPN
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminum conductor cable of 11 KV grade as required. 70 Sq. mm
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminum conductor cable of 11 KV grade as required. 120 Sq. mm.
Providing and fixing 25mmX5mm copper strip on surface or in recess for connections etc. as required.
Earthing with copper earth plate 600mm x 600mm x 3mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
Providing of polyolefin heat shrink-tube sleeve.
Providing of epoxy/ DMC round type electrical insulator.
Providing of brass cooper lugs 16 sqmm.
Providing of brass cooper lugs 10 sqmm.
Contractor profit on item no. 9 to 12
Total impact of GST for the purpose of CTC
M/S R K Enterprises
M/S S. K. CONSTRUCTION
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_329908.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .