Shri Niranjan Lal IDSE EE GE(S) BTD
GE(S) BATHINDA BATHINDA MIL STN
GE(S)BTD TOKEN NO 45 OF 2021-22 REPAIR TO SOLAR WATER HEATER SYSTEM CERTAIN EM REPAIR IN CENTRAL AMENTIES UNDER AGE EM-IV UNDER GE(S) AT MIL STN BATHINDA
2021_MES_478896_1
GE(S)/BTD/TOKEN NO 45/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE(S) BATHINDA
Class E
Category b(i)
11 documents required · 11 mandatory
₹500
GE(S) BATHINDA
₹24,000
Yes
17 Nov 2021
30 Sept 2021
29 Oct 2021
30 Sept 2021
27 Oct 2021
14 Oct 2021
Amount
Taking down carefully existing copper point wiring (light,fan, socket or power) complete including fixture and fittings such as switches, bellpushes, ceiling roses, pendents, regulators, sockets, light fitting, callbells etc removiing materials to store for keeping in safe custody or for taking credit(credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc. to match existing complete all as specified and directed
M & L for Point wiring with multi-stranded copper conductor, single core FRLSH, PVC insulated and unsheathed cable, including PVC insulated unsheathed multistranded copper conductor single core FRLSH cable as earth continuity conductor to common earth and connected to earth dolly, GI terminal boxes, modular frame & cover plate (suitable for modular switch/sockets).
All as per item No. 2.00 above but One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid 20mm PVC medium duty concealed conduit complete all as specified and directed
All as per item No. 2.00 above but One Socket outlet 3 pin, 6 Amp, on the same board, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, complete all as specified and directed
All as per item No. 2.00 above but One Socket outlet 3 pin, 6 Amp, independent, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid 20mm PVC medium duty concealed conduit complete all as specified and directed
All as per item No. 2.00 above but One socket outlet 3 pin, 5/15 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid 20mm PVC medium duty concealed conduit complete all as specified and directed
All as per item No. 2.00 above but One Bell/Buzzer point controlled by one push button with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid 20mm PVC heavy duty concealed conduit complete all as specified and directed
All as per item No. 2.00 above but One light point controlled by two, 2 way switches with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid 20mm PVC medium duty concealed conduit complete all as specified and directed
S&F Switch modular type, single pole, one way, 6 Amp, one module, complete complete all as specified and directed
S&F Switch modular type, single pole, one way, 16 Amp, one module, complete complete all as specified and directed
S&F Switch modular type, single pole, two way, 6 Amp, one module, complete complete all as specified and directed
S&F Bell push switch modular type, single pole one way, 6 Amp, one module, complete complete all as specified and directed
S&F Socket outlet modular type, multipurpose, 2/3 pin, single pole one way, 6 Amp, two module, complete complete all as specified and directed
S&F Socket outlet modular type, multipurpose, 2/3 pin, single pole one way 6/16 Amp, two module, complete complete all as specified and directed
S&F Fan regulator, modular type, 5 step, high speed, two module complete complete all as specified and directed
M & L for point wiring for one light / fan point controlled by one switch with 1.5 Sqmm (nominal area) PVC insulated, unsheathed multi stranded copper conductor cable FR-LSH in existing conduit, and existing sunken boxes but including 3 mm thick phenolic laminated sheet top cover for sunken boxes flush to surface for one light point/fan point, controlled by one switch and /or fan regulator including PVC insulated unsheathed 1.5 Sqmm copper conductor cable FR-LSH connected to common earth dolly complete all as specified and directed
All as per srl item No. 16.00 (here-in-before) but socket 3 pin, 5 Amp, 230 volt flush type on same board
All as per srl item No. 16.00 (here-in-before) but for one socket point, out let, 3 pin, 5 Amp in independent board.
All as per srl item No. 16.00 (here-in-before) but for call bell point.
All as per srl item No. 16.00 (here-in-before) but for one light point controlled by two way switch.
All as per srl item No. 16.00 (here-in-before) but for 15 Amp socket out let by using 2.5 Sqmm PVC insulated unsheathed copper conductor cable FR-LSH multi strand on independent board including provn of 2.5 Sqmm unsheathed, multi stranded copper conductor cable FR-LSH continues as earth wire connected to earth dolly etc complete all as specified and directed
S&F Switch piano, flush type, single pole, one way 5 Amp complete all as specified and directed
S&F Switch piano, flush type, single pole, one way 15 Amp complete all as specified and directed
S&F Switch piano, flush type, single pole, two way 5 Amp complete all as specified and directed
S&F bell push 5/6 Amps 230 V AC complete all as specified and directed
S&F Socket outlet 3 pin, 5Amp, flush type complete all as specified and directed
S&F Socket outlet 2 in 1, 3 pin, 5 and 15 Amp flush type complete all as specified
S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd. complete all as specified and directed
S&F Ceiling rose, 3 terminal PVC/polycarbonate, suitable for 230 V, AC, 50 Hz supply complete all as specified and directed
S&F call bell ding dong type AC 230 V complete all as specified and directed.
S&F wall mounted extruded Aluminium/polycarbonate LED batten fixture T8(G13 holder) 1.2 m, including one LED retrofit tube 20(±10%) watt, 1.2 m T8 6500K,efficacy not less than 90 lumen/watt, extruded Aluminium/polycarbonate, PC diffusor and inbuilt driver complete complete including making connection complete all as specified and directed.
S&F LED panel light fitting, recessed mounted, square shaped of size (595x595x65) mm, 36(±10%)watts efficacy not less than 90 lumen/watt, extruded Aluminium/polycarbonate, PC diffusor, module and inbuilt driver complete including making connection complete all as specified and directed.
S&F LED street light fitting 35 Watt 230V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrossion resistant complete with IP 65/66 protection including fixing with GI/MS bracket made out of suitable size of light grade tube upto 1.2 mtr length bent to shape with 02 sets of MS clamps made out of minimum 3 mm MS flat iron with suitable bolt and nuts complete with making connection complete allas specified and directed
S&F Lamp holder PVC/polycarbonate type with back plate complete all as specified and directed.
S&F in replacement sub main two single core PVC copper conductor unsheathed wire multi stranded 6 sqmm along with earth wire 6.0 sqmm copper conductor single core wire connected by common earth in and including medium grade 20mm size concealed conduit complete complete all as specified and directed(Note :- two lengths of 6.0 sqmm cable and one length of 6.0 sqmm earth cable alongwith pvc concealed conduit will be measured as one running length)
S&F in replacement sub main two single core PVC copper conductor unsheathed wire multi stranded 6 sqmm along with earth wire 6.0 sqmm copper conductor single core wire connected by common earth in existing surface/recessed PVC/steel conduit complete complete all as specified and directed(Note :- two lengths of 6.0 sqmm cable and one length of 6.0 sqmm earth cable will be measured as one running length)
Supplying, laying, jointing & testing, in replacement underground XLPE insulated screen PVC bedded, GI steel strip or wire armoured heavy duty LT electric power cable cross sectional area 10 sqmm 2 core with aluminium conductor, 1100Volts grade, complete all as specified and directed
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. N exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and directed
Removing excavated surplus soil to a distance n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed
M&L for Sand cushioning in trenches for cables including watering and consolidation complete all as specified and directed
M&L for Bricks protection with old size Sub classs B bricks for protection of PVC/XLPE UG cable in trenches with axis perpendicular to cable, laid dry and flat, joining each other with gap between adjacent bricks not exceeding 10mm complete all as specified and directed
M&L for providing cement concrete 1:2:4(20mm graded stone aggregate) type B1 in foundation, filling & mass concrete etc. Any work, including demolition of old cement concrete complete all as specified and directed
Supply, laying & testing 'light grade' galvanised, 50mm bore with all fitting, unions, elbows etc and fixed complete to walls and ceilings or laid in floors including taking down old GI pipe complete all as specified and directed
M & L for earthing with galvanized steel plate electrode 600 x 600 mm x 6 mm size directly burried in ground vertically to earth pit not less than 2.25 meter deep below normal ground level with top edge of the earth plate not less than 1.5 m below normal ground level surrounded with coal dust and common salt filling in alternative layers of 15 cm thick each connected to and including GI earth wire 4 mm dia by means of nuts, bolts, check nuts & washers etc connecting to earthing test point, main switch board and including 15 mm dia GI pipe light grade for protection of earth lead from earth plate to distribution board and 20 mm dia GI pipe medium grade connected with funnel having wire mess for watering purpose including necessary excavation and earth work, PCC (1:2:4) type B-1 (using stone aggregates) for earthing pit, 10mm thick cast iron cover with angle iron frame all as specified and shown in electrical plate No 3 of SSR Part-I and testing on completion including replacement of old unserviceable.
S&F in replacement sheet metal encloser single door 2 way SPN 240V ISI marked complete with neutral and earth link and bus bar complete made out of CRCA steel sheet Factory made including blanking plate for unused module complete all as specified and directed
S&F in replacement sheet metal encloser double door 8 way SPN 240V ISI marked complete with neutral and earth link and bus bar complete made out of CRCA steel sheet Factory made including blanking plate for unused module complete all as specified and directed
-do- all as per item No 47 above but 04 way, TPN, 415 V complete all as specified and directed.
S&F in replacement single pole and neutral enclosure 240V with a two pin and earth plug and socket complete with one single pole MCB 20Amp complete all as specified and directed
S&F in repair MCB 6-32 Amp, 240V, SP, 10 KA ‘C’ series complete all as specified and directed
S&F in repair MCB 20-32 Amp, 240V, SPN, 10 KA ‘C’ series complete all as specified and directed
S&F in repair MCB, 40 to 100Amp, 415V, TPN, 10 KA ‘C’ series complete all as specified and directed
S&F in repair MCCB , four pole, 415V, FP 63A, 16kA complete all as specified and directed
S&F in repair MCCB, four pole, 415V, 100A, 16kA complete all as specified and directed
M&L for dismentaling and taking down complete solar water heater system of 1000/1100 LPD capacity installed at single/double/triple story bldgs, Refixing the same after carrying out following works:- (i) complete cleaning and de-scaling of inlet and out let connections, solar collectors, glasses, hot water tank, cold water tank, make up tank, fittings, fixtures & pipelines etc with suitable chemical agent. (ii) Complete servicing and maintenance (iii) Replacement of unsv spares as deemed necessary such as hot water tank, flat plate collectors, rubber gaskets, nuts, bolts, clamps, flanges etc., repair of minor leakages if any by carrying out minor welding/brazing. (iv) complete testing and to ensure proper functioning & maintaining minimum water temparature i.e.60°C. complete all as specified and directed. Note : (a) Cost of minor spares such as chemical agents, rubber gaskets, nuts, bolts, clamps, flanges etc and minor welding/brazing deemed to be included in the quoted rate. (b) The cost of hot water tank, flat plate collectors shall be paid in respective items from item No 58 to 63.
All as per item No 55 here-in-before but of capacity 500 LPD complete all as specified and directed
All as per item No 55 here-in-before but of capacity 300/200/100 LPD complete all as specified and directed
Supply only hot water tank of capacity 1000 Ltrs without heat exchanger (Non pressurized) type, inner tank made of SS 304L with inlet, outlet & overflow arrangement & valves, duly insulated with glass wool/rockwool not less than 100mm thick layer & outer metallic body and including sacrificial anode, temperature guage & make-up tank etc. complete all as specified and directed. Note:- The fixing of tank shall be paid under item No. 55 here -in- before.
Supply only hot water tank of capacity 500 Ltrs without heat exchanger (Non pressurized) type, cylindrical shape, inner tank made of SS 304L with inlet, outlet & overflow arrangement & valves, duly insulated with glass wool/rockwool not less than 100mm thick layer & outer metallic body and including manufacturer recommended electrical backup(heating elements & thermostat), sacrificial anode, temperature guage & make-up tank etc. complete all as specified and directed. The electrical back-up system should be thermostatically controlled at 50°C complete all as specified and directed. Note:- The fixing of tank shall be paid under item No. 56 here -in- before
Supply only hot water tank of capacity 200/300 Ltrs without heat exchanger (Non pressurized) type, inner tank made of SS 304L with inlet, outlet & overflow arrangement & valves, duly insulated with glass wool/rockwool not less than 100mm thick layer & outer metallic body and including sacrificial anode, temperature guage & make-up tank etc. complete all as specified and directed.Note:- The fixing of tank shall be paid under item No. 57 here -in- before
Supply only hot water tank of capacity 100 Ltrs without heat exchanger (Non pressurized) type, cylindrical shape, inner tank made of SS 304L with inlet, outlet & overflow arrangement & valves, duly insulated with glass wool/rockwool not less than 100mm thick layer & outer metallic body and with manufacturer recommended electrical backup(heating elements & thermostat), sacrificial anode, temperature guage & make-up tank etc. complete all as specified and directed. The electrical back-up system should be thermostatically controlled at 50°C complete all as specfied. Note:- The fixing of tank shall be paid under item No. 57 here -in- before
Supply only hot water tank of capacity 100 Ltrs without heat exchanger (Non pressurized) type, inner tank made of SS 304L with inlet, outlet & overflow arrangement & valves, duly insulated with glass wool/rockwool not less than 100mm thick layer & outer metallic body and including sacrificial anode, temperature guage & make-up tank etc. complete all as specified and directed. Note:- The fixing of tank shall be paid under item No. 57 here -in- before
Supply & Installation in repair of rotational moulded three layered white in colour, polyethylene water storage tanks (cylindrical, vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I of capacity 1000 Ltrs. including inlet /outlet arrangements & other accessories (of approved make ) etc complete all as specified and directed
Supply & Installation in repair of rotational moulded three layered white in colour, polyethylene water storage tanks (cylindrical, vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I of capacity 500 Ltrs. including inlet /outlet arrangements & other accessories (of approved make ) etc complete all as specified and directed
Supply & Installation in repair 300 litres HDPE water storage tanks Polytuf Three layered white in colour, rotational moulded polyethylene (cylindrical vertical with closed top) , hoisted and fixed in position including inlet /outlet arrangements & other accessories (of approved make ) etc complete all as specified and directed
Supply & Installation in repair 200 litres HDPE water storage tanks Polytuf Three layered white in colour, rotational moulded polyethylene (cylindrical vertical with closed top) , hoisted and fixed in position including inlet /outlet arrangements & other accessories ( of approved make ) etc complete all as specified and directed
S&F in Repair 15mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for fixed complete all as specified and directed
S&F in Repair 20mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for fixed complete complete all as specified and directed
M&L in repair Iron/steel framed work for supporting structure of water tanks, collectors and similar work conforming to Fe-290 Gde-E-165 inclusive of one primer coat, one under coat and one finishing coat of approved paint complete all as specified and directed.
Supply, laying & testing 'medium grade' galvanised, 15mm bore with all fitting, unions, elbows etc and fixed complete to walls and ceilings or laid in floors including taking down old GI pipe complete all as specified and directed
Supply, laying & testing 'medium grade' galvanised, 20mm bore with all fitting, unions, elbows etc and fixed complete to walls and ceilings or laid in floors including taking down old GI pipe complete all as specified and directed
Supply, laying & testing 'medium grade' galvanised, 25mm bore with all fitting, unions, elbows etc and fixed complete to walls and ceilings or laid in floors including taking down old GI pipe complete all as specified and directed
Supply and fixing in repair of aluminium cladding with wire mesh and minimum 50mm thick glasswool of 48kg/m3 density for hot water 15mm GI tubing complete with fittings and fixing materials complete all as specified and directed
Supply and fixing in repair of aluminium cladding with wire mesh and minimum 50mm thick glasswool of 48kg/m3 density for hot water 20mm GI tubing complete with fittings and fixing materials complete all as specified and directed
S&F in replacement toughned radiation glass having exellent solar transmittance(minimum 90%), of minimum 4mm size thick & of standard size as per existing arrangement of solar collector complete complete all as specified and directed
S&F in replacement rubber hose pipe minimum 50mm thick of size 15mm dia between hot water tank & collector complete all as specified and directed
S&F in replacement of temperature gauge range 0 to 100 °C as per existing size complete all as specified and directed
M&L in repair for size 15mm gun metal globe or gate valve with iron wheel head screwed both end for iron pipe complete all as specified and directed.
M&L in repair for size 20mm gun metal globe or gate valve with iron wheel head screwed both end for iron pipe complete all as specified and directed.
M&L in repair for size 25mm gun metal globe or gate valve with iron wheel head screwed both end for iron pipe complete all as specified and directed.
S&F in repair 15mm size, Bib taps cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed
S&F in repair 20mm size, Bib taps cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified
S&F in replacement heating element 5.0 KW 230V AC, 50 cycle, triangular / round type ISI marked complete with rubber gasket for hot water tank electrical back up system complete all as specified & directed
S&F in replacement heating element 3.0 KW 230V AC, 50 cycle, triangular / round type ISI marked complete with rubber gasket for hot water tank electrical back up system complete all as specified & directed
S&F in replacement thermostat ISI marked stem type 240 Volts, AC supply temp range at least 30 to 75 degree C for geyser/solar water heater system complete all as specified and directed
S&F in repair Switch modular type single pole, one way, 6 Amp, one module, complete complete all as specified and directed
S&F in repair Switch modular type single pole one way, 16 Amp, one module, complete complete all as specified and directed
S&F in repair Socket outlet modular type, multipurpose, 2/3 pin, single pole one way, 6 Amp, two module, complete complete all as specified and directed
S&F in repair Socket outlet modular type multipurpose 2/3 pin single pole one way 6/16 Amp, two module, complete complete all as specified and directed
S&F in repair Fan regulator, modular type, 5 step, high speed, two module complete complete all as specified and directed
S&F in repair wall mounted extruded Aluminium/polycarbonate LED batten fixture T8(G13 holder) 1.2 m, compatible with existing T8 retrofit tube complete including making connection complete all as specified and directed.
S&F in repair retrofit LED tubelight 20(±10%) watt compatible with existing batten fixture, 1.2 m T8 6500K,efficacy not less than 90 lumen/watt, extruded Aluminium/polycarbonate, PC diffusor and inbuilt driver complete all as specified and directed.
S&F in repair LED street light fitting 35 Watt 230V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrossion resistant complete with IP 65/66 protection including fixing with GI/MS bracket made out of suitable size of light grade tube upto 1.2 mtr length bent to shape with 02 sets of MS clamps made out of minimum 3 mm MS flat iron with suitable bolt and nuts complete with making connection complete allas specified and directed
S&F in repair LED flood light fitting sqaure shape 150 Watt 230V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp, bracket with impact and corrossion resistant complete with IP 65/66 protection with suitable bolt and nuts, fixing at any height upto 15m complete with making connection complete all as specified and directed
S&F in repair wall mounted LED batten fitting 10 (±10%) watt, 6500K, 0.6m, efficacy not less than 90 lumen/watt , extruded Aluminium/polycarbonate, PC diffusor and inbuilt driver complete includign making connection complete all as specified and directed.
S&F in repair decorative wall light fixture made of polycarbonate suitable for retrofit 9W LED lamp(base B-22) complete with PC diffusor & including one 9W LED lamp(base B-22), 6500K, not less than 90 lumen/watt efficacy including making connection complete all as specified and directed.
S&F in repair surface mounted round shape 6 watt 220V AC surfce type with high efficiency PMMA diffusor soft glare free light complete with drivers, holders, LED lamps suitable for roof ceiling inlcluding making connection complete all specified and directed
S&F in repair LED downlighter/spot light fitting, recessed mounted, round shaped of ceiling cut outφ90mm, 03watts efficacy not less than 90 lumen/watt, 6500K extruded Aluminium/polycarbonate, PC diffusor, module and inbuilt driver complete including making connection complete all as specified and directed.
S&F in repair LED downlighter/spot light fitting, recessed mounted, round shaped of ceiling cut outφ160mm, 12watts efficacy not less than 90 lumen/watt, 6500K extruded Aluminium/polycarbonate, PC diffusor, module and inbuilt driver complete including making connection complete all as specified and directed.
S&F in repair LED landscape/bollard light fitting, round shaped of 0.6m pole size, 8/10watts, efficacy not less than 90 lumen/watt, extruded Aluminium/polycarbonate, IP65, PC diffusor, module and inbuilt driver complete including making connection & fixing of pole base with nut and bolt to PCC pedestal/coping complete all as specified and directed.
S&F in repair LED panel light fitting, recessed mounted, square shaped of size (595x595x65)mm, 36(±10%)watts efficacy not less than 90 lumen/watt, extruded Aluminium/polycarbonate, PC diffusor, module and inbuilt driver complete including making connection complete all as specified and directed.
S&F in repair LED panel light fitting, surface mounted, square shaped of size (600x600x70) mm, 34(±10%)watts efficacy not less than 90 lumen/watt, extruded Aluminium/polycarbonate, PC diffusor, module and inbuilt driver complete including making connection complete all as specified and directed.
S&F in repair LED panel light fitting, recessed mounted, rectangle shaped of size (1195x295x70) mm, 36(±10%)watts efficacy not less than 90 lumen/watt, extruded Aluminium/polycarbonate, PC diffusor, module and inbuilt driver complete including making connection complete all as specified and directed.
S&F in repair post top lantern LED type 20 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistance complete with driver and lamp complete all as specified and directed
Taking down unsv ceiling fan/exhaust fan, sealing cable end dismentaing blades and removing fan and blades to E/M store complete all as specified and directed.
Hanging only ceiling fan and connecting up incluidng provision of cable from ceiling rose or connector to fan complete all as specified and directed. Note: Ceiling Fans shall be provided by the E/M store free for fixing only.
Fixing only exhaust fan and connecting up including provision of cable from ceiling rose/connector to fan complete all as specified and directed. Note: Exhaust fan shall be provided by the E/M store free for fixing only.
S&F in repair rigid non-metallic PVC conduit external dia 20mm in size exclusive of boxes(junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.complete all as specified and directed.
S&F in repair PVC junction boxes(1 to 4 way) complete all as specified and directed.
Supplying and fixing in replacement 1100volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 6sqmm complete all as specified
Supplying and fixing in replacement mild steel Make up tank 5 Ltrs capacity synthetic painted with single coat of primer as per approved dimension matched with ground sample complete all as specified and directed.
Supplying and fixing in replacement PVC/PS/HDPE cable junction box of size 100mmx100mmx60mm complete with terminals 5 pole, IP 65 protected complete all as specified and directed
Labour only for attending door to door, ARMAAN, & user complaints to carryout inspection, cleaning & normal servicing of solar water heating system at various location for faulty connections and making solar water heating system serviceable after testing complete all as specified and directed. Note: 1. Cost of minor spares such as rubber gaskets, nuts, bolts, clamps, flanges etc and minor welding/brazing deemed to be included in the quoted rate. 2. Proper record & document to be maintained for each complaint/inspection duly signed by user, cost incurred on this deemed to be included in the quoted rate.
Note:- Net contract sum shall be calculated after deduction of Sch of credit of Rs. 80510.00.
L H ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .