Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.7 LAccepted-AOC 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | L1 | Accepted-AOC Accepted due to L1 | |
| 2 | L2₹27.4 L+₹1.4 L (5.33%)Rejected-AOC RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L2 | Rejected-AOC Higher rate | |
| 3 | Rejected-Technical 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | - | Rejected-Technical Due to not uploaded requisite MOU | |
| 4 | Rejected-Technical 13 218 MASJID EXTEN SADAR BAZAR | - | Rejected-Technical Due to not uploaded requisite MOU |
Tender Value
₹37 L
EMD Value
₹74,000
Closing Date
23 Jul 2020, 6:00 pmClosed
GE NEW DELHI
GE NEW DELHI ARMY HOSPITAL R AND R COMPLEX RAO TULA RAM MARG DELHI CANTT 10
REPAIR / MAINT OF AIR CONDITIONING AND COOLING APPLIANCES AT HQ IDS, AFC, AFDC, ABH MESS, TPT UNIT ASC AND NAVAL AREA INCLUDING MAINT AND OPERATION AT AMAR JAWAN JYOTI AT INIDA GATE UNDER GE NEW DELHI
2020_MES_345520_2
GE/ND-06/2020-21
Open Tender
Civil Works
Item Rate
330 days
GE NEW DELHI
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE NEW DELHI
₹74,000
Yes
20 Aug 2020
2 Jul 2020
25 Jul 2020
2 Jul 2020
23 Jul 2020
9 Jul 2020
Amount
Labour for checking and attending complants of ACs, water coolers, Refrigerators etc of any capacity, rectification minor defects and make the equipment functional complete all as specified and directed.(any parts required for replacement shall be measured and paid separately under respective items) Note:- :- 1. The contractor should detail minimum one AC Mechanic & one helper to attend complaints in HQ IDS, AFC & AFDC. 2 The complaint should be attended on same day. 3. If the complaint not attended/not completed on same day recovery will be done as follows:- (i) For first day Rs.200/- (ii) For second day Rs.300/- (iii) For next every day Rs.500/-
Servicing of Window type AC 1.5/2 Ton capacity of any make / model by taking out the AC, Cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of AC. Note: Unserviceable spares parts required to be replaced shall be measured and paid separately under respective items.
All as per item No 2 above but Split type AC of any type and 1.5/2 Ton capacity. Note: Unserviceable spares parts required to be replaced shall be measured and paid separately under respective items.
Servicing of three phase cassette type split AC 3.5 to 4.0 Ton capacity of any make / model with indoor and outdoor unit by taking out the AC, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of AC complete all as specified. Note: Unserviceable spares parts required to be replaced shall be measured and paid separately under respective items.
Supply only in replacement starting capacitor 80-100 Mfd sutaible for AC 1.5 Ton Make : Usha/Epcos/Havells
Supply only against repairs starting capacitor 100-120 Mfd suitable for AC upto 4.00 Ton. Make : Tesla/Epcos/Havells
Supply only in replacement Running capacitor 36 mfd 230 volt suible for AC 1.5 Ton Make : Havells/Epcos/Tesla
Supply only against repairs running capacitor 45 mfd 230 volt suitable for AC 2 Ton .
Supply only against repairs running capacitor combination 50 mfd + 6 mfd 230 Volt for AC upto 4.00 Ton .
Supply only in replacement Running capacitor 6 mfd 230 volt. Make : Usha/Epcos/Havells
Supply only in replacement Running capacitor 4 mfd 230 volt Make : Usha/Epcos/Tesla
Supply & charging gas refrigerant R-22/R 410 A or as existing to window type AC up to 2 Ton capacity including removing of leakage if any and testing complete all as specified & directed by Engineer-in-charge
All as per item No 12 above but for Split AC of any type and 1.5/2 Ton capacity
Supply & charging the gas refrigerant R-22/R 410 A or as existing No to cassette type Split AC 3.5 to 4.0 Ton capacity including removing of leakage if any and testing complete all as specified & directed.
Supply only in replacement starting relay suitable for 1.5/2 Ton capacity AC Make : Renutrol/Classic/Indfos
Supply only in replacement over load protector suitable for 1.5 Ton capacity AC. Make : Pecific/renutrol/Hitech
Supply only in replacement thermostat switch suitable for 1.5/2 Ton capacity AC Make : Pecific/renutrol/Indfos
Supply only against in replacement of unsv item of starting relay suitable for 4.0 Ton capacity AC complete all as specified.
Supply only against in replacement of unsv item of over load protector suitable for 4.0 Ton capacity AC complete all as specified.
Supply only against in replacement of unsv item of thermostat switch suitable for 4.0 Ton capacity AC complete all as specified.
M&L for Taking down of defective /unserviceable reciprocating compressor of split type AC capacity 1.5 TR and replacing the same with new compressor reciprocating type capacity 1.5 TR, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge. Make : Kirloskar/Carrier/Tecumseh/existing make
M&L for Taking down of defective /unserviceable roatry compressor of split type AC capacity 1.5 TR and replacing the same with new compressor roatry type capacity 1.5 TR, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge Make : Kirloskar/Carrier/Tecumseh/existing
M&L for taking down for defective unserviceable DC compressor of split type AC cap 1.5 TR and replacing the same with new compressor rotary type DC cap 1.5 TR, refixing including brazing work etc pressure testing, establishing vaccum for dehydration complete all as specified and directed.
M&L for Taking down of defective /unserviceable reciprocating compressor of split type AC capacity 2.0 TR and replacing the same with new compressor reciprocating type capacity 2.0 TR, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge. , Make: Kirloskar/Carrier/Daikin/existing make AC's complete all as specified.
M&L for Taking down of defective /unserviceable rotary compressor of split type AC capacity 2.0 TR and replacing the same with new compressor roatry type capacity 2.0 TR, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge. Make: Kirloskar/Carrier/Daikin/existing make AC's complete all as specified.
Supply and fixing in replacement after Taking down defective /unserviceable AC reciprocating compressor of capacity 3.5/4.0 TR , refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge. of three phase compressor suitable for 3.5 to 4.0 Ton capacity for Casette Type AC 3.5/4.0 Ton, Make: Kirloskar/Carrier/Daikin/existing make AC's complete all as specified.
Supply only in replacement air filter synthetic/ nylon as per existing size and shape suitable for 1.5/2 Ton capacity window type Acs
All as per item No 26 above but for 1.5/2 Ton capacity for Split type ACs.
Supply only against in replacement item of air filter synthetic / nylon type as per existing size and shape suitable for 3.5/4.0 Ton capacity cassette type split AC's complete all as specified.
M&L for taking down existing unsv fan motor and fixing of new fan motor in replacement for blower of indoor 1/4,1/5 HP single/double shaft as per existing model on site sutaible for Split type ACs 1.5/2 Ton complete all as specified and directed. Make : LG/Career/Voltas/Hitachi.
M&L for taking down existing unsv DC fan motor and fixing of new fan motor in replacement for blower of indoor 1.5 HP single/double shaft as per existing model on site sutaible for Split type ACs 1.5/2 Ton complete all as specified and directed.
M&L for taking down existing unsv fan motor and fixing of new fan motor in replacement outdoor 1/4,1/5 HP single/double shaft as per existing model sutaible for Split type ACs 1.5/2 Ton complete all as specified and directed. Make : LG/Career/Voltas/Hitachi.
M&L for taking down existing unsv fan motor and fixing of new fan motor in replacement single/double shaft as per existing model suitable for 3.5/4.0 Ton AC's of any make/type complete as per requirement on site all as specified. Make : LG/Career/Voltas/Hitachi.
M&L for taking down existing unsv outdoor fan motor and taking the unsv fan motor outdoor type to authorized workshop for rewinding of fan motor suitable for ACs up to 4 Ton capacity with super enameled copper winding wire of same gauge including replacement of insulating material, bushes and shaft all as specified & directed.
Supply only in replacement PVC insulated flexible copper conductor 3 core 1100V Grade of size 70/.0076 (2.5 sqmm). Make:- Kalinga/Polycab/Havells/Finolex
All as per item No 32 above but 4 core
Supply & fix in replacement condensor fan blade made out of aluminium /plastic suitable for upto 2 Ton capacity window type Acs.
All as per item No 34 above but for Split ACs of 1.5 Ton capacity
Supply only against in repair item of condensor fan blade made out of aluminium/plastic suitable for upto 4.0 Ton capacity cassette type split AC's complete all as specified & directed.
Supply only in replacement of evaporating air blower made out of aluminium/plastic suitable for upto 2 Ton capacity for window type AC all as specfied and directed
All as per item No 37 above but for air blower of Split ACs of 1.5/2 Ton capacity
Supply only against in replacement of item of evaporating air blower made out of aluminium/plastic suitable for upto 4.0 Ton capacity cassette type split AC's complete all as specified & directed.
Supply and fix in replacement of synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split AC units. Make:- Supreme/Gulf-o-flex/Superlon.
All as per item No 40 above but internal dia13 mm (1/2")
M & L for replacement of front grill suitable for window type ACs upto 2 Ton capacity of any Make as per existing size and shape.
M & L for replacement of reverse valve system suitable to 1.5/2 Ton split/window AC for heating option.(Gas charging shall be paid and measured under respective item)
Supply and fix in replacement copper tubing heavy duty inner dia 6 mm (1/4") for refrigerant for ACs.
Supply and fix in replacement of copper tubing heavy duty inner dia 13mm (1/2") for refrigerant for ACs.
M&L for taking down existing condensing coil by removing it from existing outdoor unit by using LPG blower and fixing of new condensing coil of suitable size/capacity for 1.5/2 Ton split type Acs in replacement as per existing size/shape and as per existing make. Complete all as specified and as directed by Engr-in-Charge. Note: Work includes brazing work as required for fixing of condensing coil
M&L for taking down existing evaporating coil by removing it from existing indoor unit by using LPG blower and fixing of new evaporating coil of suitable size/capacity for 1.5/2 Ton split type Acs in replacement as per existing size/shape and as per existing make. Complete all as specified and as directed by Engr-in-Charge. Note: Work includes brazing work as required for fixing of condensing coil
M&L for taking down existing condensing coil by removing it from existing outdoor unit by using LPG blower and fixing of new condensing coil of suitable size/capacity for 1.5/2 Ton window type Acs in replacement as per existing size/shape and as per existing make. Complete all as specified and as directed by Engr-in-Charge. Note: Work includes brazing work as required for fixing of condensing coil
M&L for taking down existing evaporating coil by removing it from existing indoor unit by using LPG blower and fixing of new evaporating coil of suitable size/capacity for 1.5/2 Ton window type Acs in replacement as per existing size/shape and as per existing make. Complete all as specified and as directed by Engr-in-Charge. Note: Work includes brazing work as required for fixing of condensing coil
M&L for checking the leakage by feeding dry Nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas R-12/22/134a for water cooler, Split type/Window type AC/ Deep Freezer /Refrigerator any size any capacity as on site complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement brass flare nut/connector heavy duty of size 6 mm/9 mm (1/4", 1/2") as per existing make.
M&L for Repair of control processing board( Remote control kit) with hand set including replacement of current transformer, ICs, diodes, resistances, sensors etc complete for 1.5/2 Ton split type ACs of any make & model.
M&L for replacement of unsv display along with PCB suitable for Split type AC 1.5/2 TR with new PCB along with display unit. Make-Hitachi/Voltas/Carrier/Daikin
M&L for replacement of unsv display along with PCB suitable for Inverter type split AC 1.5/2 TR indoor and outdoor unit complete all as specified and directed.
M&L for replacement of unsv display along with PCB suitable for Cassette Type AC 3.5/4TR with new PCB along with display unit. Make-Hitachi/Voltas/Carrier/Daikin
Supply and fixing in replacement window AC kit with sensor complete with condensing coil, blower and motor suitable to existing model and make AC all as specified and directed. Make:- Carrier, Napolean & Skoda
S & F in replacement split type AC indoor unit kit 1.5 TR capacitycomplete with cooling coil, blower with motor, PCB and remote complete with fixing plate suitable to existing model and make AC all as specified and directed. Make- Hitachi/Carrier/Daikin
S & F in replacement split type AC outdoor kit 1.5 TR complete with condensing coil, blower and motor suitable to existing model and make iron grill, suitable for outdoor unit and flair nuts for connection of Copper pipe all as specified and directed. Make- Hitachi/Carrier/Daikin
Supply only air direction changer louver motor ( swing motor) suitable for split type Acs any capacity as per existing make and model
Supply only in replacement cordless Remote for inverter type ACs Hot & cool suitable for 1.5/2 Ton AC as per sample. Make- Hitachi/Voltas/Carrier
Supply only in replacement cordless Remote for ACs suitable for 1.5/2 Ton AC as per sample
Servicing of package type AC 11 Ton capacity complete with blower motor dismantling all parts and refixing after cleaning and replacement of defective parts, dismantling the cover of condensing coil carefuly and carryout servicing, cleaning the external surface (both side) and fan of the unit out side of the equipment like base plate runner fan blade throughly with the help of descaling chemical, brush, water and dry properly including using air blower for cleaning air dust deposited on the equipment and re-fixing the same after repair complete all as specified. Note:- Spare parts shall be measured and paid separately.
Servicing of package type AC 11 Ton ( 2X5.5) capacity complete with blower motor dismantling all parts and refixing after cleaning and replacement of defective parts, dismantling the cover of condensing coil carefuly and carryout servicing, cleaning the external surface (both side) and fan of the unit out side of the equipment like base plate runner fan blade throughly with the help of descaling chemical, brush, water and dry properly including using air blower for cleaning air dust deposited on the equipment and re-fixing the same after repair complete all as specified. Note:- Spare parts shall be measured and paid separately.
Supply only against in repair item of hermetically sealed compressor suitable for 5.5 Ton capacity pacakge type, Make: Kirloskar/Carrier/Daikin/existing make AC's complete all as specified.
Supply & charging the gas refrigerant R-22/R 410 A or as existing No to package type AC's of capacity 11 (2x5.5) Ton capaity including removing of leakage if any and testing complete all as specified & directed.
Supply only against in repair item of HP cut out suitable for package type AC's of capacity 11 (2x5.5) Ton complete all as specified.
Supply only against in repair item of expansion valve suitable for package type AC's of capacity 11 (2x5.5) Ton complete all as specified.
Supply only against in repair item of PCB card suitable for package type AC's of capacity 11 (2x5.5) Ton complete all as specified.
Repair/maint and servicing of micro roster based panel of package type AC's of capacity 11 (2x5.5) Ton complete including replacement of faulty diode, resistance, solenoid coil complete all as specified.
Supply only against in repair item of condensor fan blade made out of aluminium/plastic suitable for package type AC's of capacity 11 (2x5.5) Ton complete all as specified.
Supply only against in repair item of evaporating air blower made out of aluminium/plastic suitable for package type AC's of capacity 11 (2x5.5) Ton complete all as specified.
Supply only against in repair item of fan motor single/double shaft as per existing model suitable for package type AC's of capacity 11 (2x5.5) Ton complete all as specified.
Supply only against in repair item of air filter synthetic / nylon type as per existing size and shape suitable for package type AC's of capacity 11 (2x5.5) Ton complete all as specified.
Servicing of Water cooler of 40,60,120,150 ltr capacity of any make / model by cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning, greasing, oiling of fan motor and checking of electric circuit for smooth functioning complete all as specified and directed by Engr-in-Charge
Supply & charging the gas refrigerant R-134 or as existing to water coolers up to 150 ltr capacity including removing of leakage if any and testing complete all as specified & directed
Supply and fixing in replacemen new compressor suitable for 40/80 ltr capacity water cooler reciprocating type. Make:- Kirloskar/Carrier/Tecumseh/Existing make
M&L for taking down existing condensing coil from water cooler any capacity and replacement by new Condensor coil as per existing capacity including brazing and dehydration by creating vaccuum for more than 24 Hrs so that no oil/sludge remains in the cooling coil/system. Complete all as specified and as directed by Engr-in-Charge
M&L for taking down fan motor of water cooler capacity upto 150 Litres and replacement of the same by new fan motor as per existing on site upto capacity 150 litres along with fan blade and along with all mountings complete all as specified and as directed by Engr-in-Charge
Servicing of Refrigerators of 165 to 310 ltr capacity single door of any make / model by cleaning of condensing coil with wire & brush to remove dust including checking of electric circuit for smooth functioning complete all as specified and directed by Engr-in-Charge
M&L for taking down existing unsv condensing coil from Refrigerators of any capacity and replacement by new Condensor coil as per existing capacity upto 310 Ltrs including brazing and dehydration by creating vaccuum for more than 24 Hrs so that no oil/sludge remains in the cooling coil/system. Complete all as specified and as directed by Engr-in-Charge
M&L for taking down unsv fan motor of refrigerators of any capacity upto 310 Litres and replacement of the same by new fan motor as per existing on site upto capacity 310 litres along with fan blade and along with all mountings complete all as specified and as directed by Engr-in-Charge
M&l for Taking down of defective /unserviceable reciprocating compressor of Refrigerator capacity upto 310 Ltrs and replacing the same with new compressor reciprocating type capacity 310 Ltrs, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge Make : Kirloskar/LG/Tecumseh
Supply & charging the gas refrigerant R-134a or as existing to Refrigerators up to 310 ltr capacity including removing of leakage if any and testing complete all as specified & directed
Supply & fix in replacement of unsv starting relay suitable for 165 to 310 ltr capacity Refrigerator
Supply & fix in replacement of unsv over load protector suitable for Refrigerator
Supply & fix in replacement thermostat switch suitable for Refrigerator
M&L for Servicing of Deep fridger 310 ltr capacity 2/3 door of any make / model by cleaning of condensing coil with wire & brush to remove dust including checking of electric circuit for smooth functioning complete all as specified and directed by Engr-in-Charge
Supply & charging the gas refrigerant R-134a or as existing to Deep Freezers up to 310 ltr capacity including removing of leakage if any and testing complete all as specified & directed
M&L for taking down existing unsv condensing coil from Deep freezers of any capacity and replacement by new Condensor coil as per existing capacity upto 492 Ltrs including brazing and dehydration by creating vaccuum for more than 24 Hrs so that no oil/sludge remains in the cooling coil/system. Complete all as specified and as directed by Engr-in-Charge
M&L for taking down unsv fan motor of refrigerators of any capacity upto 380 Litres and replacement of the same by new fan motor as per existing on site upto capacity 380 litres along with fan blade and along with all mountings complete all as specified and as directed by Engr-in-Charge
M&l for Taking down of defective /unserviceable reciprocating compressor of Deep freezers of capacity upto 380 Ltrs and replacing the same with new compressor reciprocating type capacity upto 380 Ltrs, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge. Make : Kirloskar/LG/Tecumseh
Supply & fix in replacement of unsv starting relay suitable for 165 to 492 ltr capacity Deep freezer
Supply & fix in replacement of unsv over load protector suitable for Deep freezer
Supply & fix in replacement thermostat switch suitable for Deep Freezer
Collecting the U/S single phase voltage stabilizer of capacity from 02 KVA to 05 KVA from MES complaint cell to local workshop/in-situ for repair and open the stabilizer taking out u/s spare incl repalcement of the same with new one, incl testing complete all as specified and directed. (Replacement of spare parts will be measured and paid seperately here in as per Schedule as supply only )
Supply only in replacement relay for voltage stabilizer suitable for 2 KVA to 5 KVA capacity stabilizer
Supply only in replacement printed circuit board ( PCB) suitable for 2 KVA capacity stabilizer
Supply only in replacement printed circuit board ( PCB) suitable for 3 KVA capacity stabilizer
Supply only in replacement printed circuit board ( PCB) suitable for 5 KVA capacity stabilizer
Supply only in replacement main transformer suitable for 2 KVA capacity stabilizer
Supply only in replacement main transformer suitable for 3 KVA capacity stabilizer
Supply only in replacement main transformer suitable for 5 KVA capacity stabilizer
Supply only in replacement of voltmeter analog type 0 to 300 volts (as per sample) complete all as specified.
Supply only in replacement of ammeter analog type 0 to 30 Amps (as per sample) complete all as specified.
Supply only in replacement of connector block porcelain 4 way suitable for 30 Amps capacity complete all as specified.
S&F in replacement of plug top 3 pin, 15 Amps, 230 volts, 50 Hz AC complete all as specified.
M&L in replacement Metal Clad Plug & socket board SP&N enclosure with single pole and earth metal plug & socket suitable for 20 Amps MCB AC, 220 V, 50Hz Cat part No- DHDPUSN020/DHDPUDP020. Make- Havells/Legrand
S&F in replacement of PVC insulated and PVC sheathed, flexible copper conductor cable 3 core, 1100 volts grade, multi stranded type of size 6.0 sqmm complete all as specified.
M&L for taking down of desert cooler and Servicing of Desert cooler of any type/ capacity cleaning of tank, painting with black paint after cleaning including checking of electric circuit for smooth functioning of desert cooler complete all as specified and directed.
Supply and fix in replacement of desert cooler pad (in set of three) suitable for cooler of any make/size as required at site complete all as specified & directed.
Material & labour taking down of desert cooler fan motor and transporting the unsv motor to workshop for rewinding of desert cooler fan motor with supper enameled copper winding wire of same gague including replacement of insulating material, bushes, bearing and shaft after taking out burnt wire including transportation to civil workshop complete all as specified & directed.
Supply only against in replacement item of ON/OFF switch of desert cooler complete all as specified.
Supply only against in replacement of item of step type desert cooler regulator complete all as specified.
Supply only against in replacement of drain pipe PVC flexible, spring type of size 15 mm dia as per site requirement complete all as specified.
M & L for repair, servicing/periodical maintanence to RO Plant of capacity 50/150/250 LPH including replacement of minor spares, Pump repair, refixing the plant after repair, testing complete all as specified and directed of entire satisfactory level by Engr-in charge
S & F in replacement Membrane suitable for 250 LPH RO Plant
S & F in replacement Filter heavy Grade for 250 LPH RO Plant
S & F in replacement Electrical accessories ,Solenoid valve, for 250 LPH RO Plant
S & F in replacement Membrane suitable for 150 LPH RO Plant
S & F in replacement Filter heavy Grade for 150 LPH RO Plant
S & F in replacement Electrical accessories ,Solenoid valve, for 150 LPH RO Plant
S & F in replacement Membrane for 50 LPH RO Plant
S & F in replacement Filter heavy Grade for 50 LPH RO Plant
S & F in replacement Electrical accessories Solenoid valve for 50 LPH RO Plant
Supply only HDPE pipe 3/8"dia suitable for inlet & outlet of RO plant all as specified
Manning & Operation of Amar Jawan Jyoti Manning and operation of services for operation of Gas system LPG/CNG at Amar Jawan Jyoti round the clock in 3 shifts of 8 hours each by deploying one FGM per shift including Sunday and Holiday complete all as directed by Engr-in-Charge. The installation comprises the following :- (a) Gas burner heavy duty - 05 Nos (b) CNG Gas pipe line system complete - 02 Set (Each at Top and Bottom of India Gate) (c) LPG Gas cylinder system complete - 02 set (Each at Top and Bottom of India Gate) Note : The technician (FGM) shall be a person with vocational training/course pass out certificate in the field of fitting grade mechanic category from any Govt. approved ITI or National Trade Certificate issued by NCVT (National Council for Vocational Training) under Ministry of Labour and Employment)
RUCHIKA ENGG.WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .