Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres
Cement concrete 1:4:8 With stone aggregates 40mm gauge mixing by mechanical means using concrete mixer volumetric type
Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Centering and shuttering for columns (Square or rectangular or poly gonal in plain)
Steel work in built up tubular (round, square or rectangular hollow tubes etc. ISI Marked) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete having span:-
Nuts & Bolts of all sizes and length required
Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
Earth, Surkhi, Sand, earth, Fly Ash, Bajri, Ballast, Stone Boulders, Kankar and Building Rubbish,Earth
From Lohand Khad 109 km
Bajri :
From Mirthal 248 km
Providing and fixing roofing consist of 0.8 mm thick galvanized steel deck sheet confirming to IS 277:1992 used as permanent shuttering over which MS wire mesh 3 mm laid at 100x100 mm grid including edge trim covered with concrete. This metal deck will be supported on structural steel beam with shear studs. (Structural steel like Beam, column, joists etc. & concrete of different grade as per design will be paid separately).
Digging of pits in all kinds of soil & refilling the same, with the excavated earth mixed with well decayed farm yard manure @ 3% of pit volume and insecticide for termite control.
Supplying & Planting permanent shrubs in prepared pits and watering.
Planting ground covers (ordinary) including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, planting of sapling at 25cm distance from plant to plant and row to row.
Supplying and planting permanent trees in prepared pits and watering
Providing and fixing pair of Plastic dustbins 100 litre volume each, of two different colours, for dry and wet waste, made of virgin plastic to be mounted on MS rectangular hollow section 50 x 25 x 3 mm frames pivoted on 3 MS square hollow section verticals, 1 m above ground, one 35 cm RHS welded to each vertical member at base and grouted in 180 x 40 x 30 cm 1:2:4 cement concrete.
Boring with casing pipe for tubewell in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the tube well is lowered & tested , equipment as requried such as hand boring machine and its accessory, transportation to site and vice versa etc. complete in all respect.
Boring with 150mm id Housing Pipe Upto 150 m depth BGL.
Supplying, lowering of MS Pipe as per IS:4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore.
100mm nominal diameter (weight 14.5 kg per metre) 5.40 mm thickness
Providing & Fixing Glass fibre Reinforced Concrete GRC of pattern, design as per drawing. The Element made of ‘53 Grade’ White Portland Cement manufactured by ‘JK Cement’ or equivalent. Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber manufactured by ‘NEG or equivalent, Super Plasticizers manufactured by ‘BASF’ or equivalent, polymers manufactured by ‘BASF’ or equivalent. The casting material will be in FRP Mold. Installation by Dry fixing method.
Making and supplying of 6 feet high (Life Size) bronze statue - 10 Nos.statues are of Punjabi Bhangra men, 10 Nos. statues of Punjabi Giddha Women and 10 of Punjab warriors like Bhagat Singh, Lala Laj Pat Rai , Kartar Sarbha , etc – total 30 Nos. of statues to be installed at Punjab
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-
RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):
Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp.combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):-
Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. Erected at switchboard height.
CONDUIT PIPE & COPPER WIRES: (Circuit and Submain Wiring)
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
SUB DISTRIBUTION SYSTEM:
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's:-
"Supply and erection of sheet metal double door Phase segregated distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 3 Nos. shrouded neutral bars, 3 Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties,blanking plates and circuit identifications label, compartmentalizing each phase (separated incomer, sub incomer & outgoing) and of required no. of ways for mounting FP MCB's as incomer, DP/RCBO's/RCCB's as sub incomer and SP MCB's as outgoings in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc."
Supply and erection of sheet metal double door Phase segregated distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 3Nos. shrouded neutral bars, 3Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label, compartmentalizing each phase (separated incomer, sub incomer & outgoing) and of required no. of ways for mounting FP MCB's as incomer, DP/RCBO's/RCCB's as sub MCB's as incomer, DP/RCBO's/RCCB's as sub incomer and SP MCB's as outgoings in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:-
Supply and erection of sheet metal Cable End Box (Make is same as MCB Distribution Board) mounting on the top or bottom of the MCB Distribution Board (Either Horizontal or Vertical) to keep loose wires & cables as per PWD General specifications including petty materials etc as required:-
MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-
RCBO's:
Supply and erection of RCBO (Residual Current Breaker Overload) for Earth leakage, overload and short circuit protection suitable for 240/415 volts 50 cycles AC supply with breaking capacity of 10kA as per IEC 61009 inthe existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:
Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:-
Supply and erection of Compression glands, Locking arrangement, Checknuts for PVC flexible pipe complete with as required:-
XLPE INSULATED ARMOURED CABLES (LOOSE):
Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-
Overall size 6 sq.mm (4Core) Armoured (Loose)
Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-
Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3metre long
LED'S FIXTURES & FANS:
Supply and erection of Slim Recessed mounted,LED Fixture Surface/Reces Round downlighter 15 watt with Pressure die cast aluminium housing & polycarbonate diffuser with surge protection 10KV and efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 %, housing & driver shall be of same brand, supported with LM 79 reports not more than 2 years old from NABL /UL accredited laboratory complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. The certification and specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory.
SITC of 20W LED Wall mounted Bracket light fixture, Key features are: Clean contemporary design, Fits perfectly into any home, Premium material, Beautiful glass & glossy finish, Dimension (in mm): 100x125x200, Max wattage: 1x 20W with Lamp Base E27.
Supply and erection of BEE 5-Star rating AC Ceiling Fan 1200mm (48") suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body, 3Nos. of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air deleivery of 210 CMM (approx.). The rated speed of the the product must be minimum of 300 revolutions per minute and 5Nos. of speeds. The product should have a manufcaturer's guarantee /warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer in-charge at site.
Supplying, Installation, Testing & Commissioning of 250 mm sweep fresh air ventilating fan with aerodynamically designed & balanced blades suitable for operation on 230 v single phase AC supply complete connection with 3 x 1.5 sq.mm. PVC insulated FRLS PVC sheathed copper conductor etc as required as reqd.with all accessories as required
Supply and erection of Heavy duty Exhaust Fan 300mm, 900RPM with aluminium louver shutter, double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site.
SAFETY EQUIPMENTS:
Providing and fixing of 4.5 Kg. Capacity FIRE EXTINGUISHER,CO2 type as per IS:15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect
Providing and fixing of 6 Kg. Capacity FIRE EXTINGUISHER, ABC Powder type (stored pressure) asper IS:15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect
Supply, installation, testing and commissioning (SITC) of high-quality multi-colour RGBW (4-in-1) LED wash light, DMX-RDM based, IP66 protection, complying with BIS IS 10322 (Part 5/Sec 1):2012 and CE standards (EN 60598-2-1:2020, EN 61547:2020). Fixture shall have die-cast/extruded aluminium housing with adjustable yoke mounting and embossed rotation angles. Power consumption 50W with RGBW (3000K/6500K), luminous efficacy >45 lm/W, CRI >80. Optics with PMMA/PC lens, beam angle 25°/45°/60°/asymmetrical (as per design). Fixture shall support DMX, Ethernet and RDM control with 16 million colours, channel options (4/8 channels) including dimming, strobe, macro and speed control. Auto colour synchronisation in case of DMX signal loss. Integral driver (AC 110–270V, 50/60 Hz) or external driver (DC 24V, efficiency >90%, THD <10%). Surge protection 2–4 kV, IK08 impact resistance, toughened glass cover, IP68 air vent for moisture control. Operating temperature -10°C to +60°C. Powder-coated corrosion-resistant finish after chemical reatment. PCB: 1.6 mm thickness, 35-micron copper, 2W TC, OSP finish. LEDs from REE/Lumileds/Osram/Seoul/Nichia or equivalent with LM80 certification (L70B50 ≥ 50,000 hrs at 25°C). Complete with IP67 connectors, power & DMX loop in/out cables (>300 mm), mounting accessories, pre-wired system, and all necessary components. OEM must have NABL-approved in-house testing facilities with LM79, IK, IP, electrical, thermal and surge test reports. Submission of IES files, catalogues, polar and cone diagrams mandatory. Certifications: CE, RoHS, BIS with valid R-number.- 50 Watt
Supply, installation, testing and commissioning (SITC) of high-quality multi-colour RGBW (4-in-1) LED wash light, DMX-RDM based, IP66 protection, complying with BIS IS 10322 (Part 5/Sec 1):2012 and CE standards (EN 60598-2-1:2020, EN 61547:2020). Fixture shall have die-cast/extruded aluminium housing with adjustable yoke mounting and embossed rotation angles. Power consumption 100W with RGBW (3000K/6500K), luminous efficacy >45 lm/W, CRI >80. Optics with PMMA/PC lens, beam angle 25°/45°/60°/asymmetrical (as per design).Fixture shall support DMX, Ethernet and RDM control with 16 million colours, channel options (4/8 channels) including dimming, strobe, macro and speed control. Auto colour synchronisation in case of DMX signal loss. Integral driver (AC 110–270V, 50/60 Hz) or xternal driver (DC 24V, efficiency >90%, THD <10%).Surge protection 2–4 kV, IK08 impact resistance, toughened glass cover, IP68 air vent for moisture control. Operating temperature -10°C to +60°C. Powder-coated corrosion-resistant finish after chemical treatment.PCB: 1.6 mm thickness, 35-micron copper, 2W TC, OSP finish. LEDs from CREE/Lumileds/Osram/Seoul/Nichia or equivalent with LM80 certification (L70B50 ≥ 50,000 hrs at 25°C).Complete with IP67 connectors, power & DMX loop in/out cables (>300 mm), mounting accessories, pre-wired system, and all necessary components. OEM must have NABL-approved in-house testing facilities with LM79, IK, IP, electrical, thermal and surge test eports.Submission of IES files, catalogues, polar and cone diagrams mandatory. Certifications: CE, RoHS, BIS with valid R-number.- 100 Watt
Supply, installation, testing and commissioning (SITC) of high-quality multi-colour RGBW (4-in-1) LED projector spotlight, DMX based, IP66 protection, complying with BIS IS 10322 (Part 5/Sec 1):2012 and CE standards (EN 60598-2-1:2020, EN 61547:2020). Fixture shall have die-cast/extruded aluminium housing with embossed manufacturer logo and adjustable surface mounting yoke with angular markings.Power consumption 20W, CCT RGBW (3000K/6500K as per design), luminous efficacy >45 lm/W, CRI >80. Optics with PMMA/PC lens and beam angle options 25°/45°/60°/asymmetrical as per design.Fixture shall support DMX control with 16 million colours, offering 4/8 channel configuration with dimming, colour mixing, strobe, macro and speed control functions. Auto colour synchronisation in case of DMX signal loss with loop in/loop out provision.Driver: AC 110–270V, 50/60 Hz integral driver (Class I) or DC 24V external driver (Class III) with efficiency >90% and THD <10%. Surge protection 2–4 kV.Construction: Toughened glass (IK07 or higher), corrosion-resistant powder-coated finish after chemical treatment, IP68 air vent for moisture control. Operating temperature range -10°C to +60°C.PCB: 1.6 mm thickness, 35-micron copper, 2W TC, OSP finish. LED make: CREE/Lumileds/Osram/Seoul/Nichia or equivalent with LM80 certification (L70B50 ≥ 50,000 hours at 25°C).Complete with IP67 connectors, power & DMX loop in/out cables (>300 mm), pre-wired system, mounting accessories, and all required components.OEM must have NABL-approved in-house testing facilities. LM79, IK07, IP66, electrical, thermal, endurance and surge test certificates to be submitted. IES files, catalogues, polar and cone diagrams mandatory. Certifications: CE, RoHS, BIS with valid R-number.- 20 watt
Supply, installation, testing and commissioning (SITC) of high-quality multi-colour RGBW (4-in-1) LED spotlight projection , DMX based, IP66 protection, complying with BIS IS 10322 (Part 5/Sec 1):2012 and CE standards (EN 60598-2-1:2020, EN 61547:2020). Fixture shall have die-cast/extruded aluminium housing with embossed manufacturer logo and adjustable surface mounting yoke with angular markings. Power consumption 12W, CCT RGBW (3000K/6500K as per design), luminous efficacy >45 lm/W, CRI >80. Optics with PMMA/PC lens and beam angle options 25°/45°/60°/asymmetrical as per design.Fixture shall support DMX control with 16 million colours, offering 4/8 channel configuration with dimming, colour mixing, strobe, macro and speed control functions. Auto colour synchronisation in case of DMX signal loss with loop in/loop out provision. Driver: AC 110–270V, 50/60 Hz integral driver (Class I) or DC 24V external driver (Class III) with efficiency >90% and THD <10%. Surge protection 2–4 kV.Construction: Toughened glass (IK07 or higher), corrosion-resistant powder-coated finish after chemical treatment, IP68 air vent for moisture control. Operating temperature range -10°C to +60°C. PCB: 1.6 mm thickness, 35-micron copper, 2W TC, OSP finish. LED make: CREE/Lumileds/Osram/Seoul/Nichia or equivalent with LM80 certification (L70B50 ≥ 50,000 hours at 25°C).Complete with IP67 connectors, power & DMX loop in/out cables (>300 mm), pre-wired system, mounting accessories, and all required components. OEM must have NABL-approved in-house testing facilities. LM79, IK07, IP66, electrical, thermal, endurance and surge test certificates to be submitted. IES files, catalogues, polar and cone diagrams mandatory. Certifications: CE, RoHS, BIS with valid R-number.- 12 watt
ITC of high quality Multi Color Neon Flexible light, Protection Rating : IP65, Mounting Structure : Adjustable wall mount aluminium profile for fixing the lights. Power consumption : 12W, CCT : RGB/RGBW, (as per the design approval) Beam Angle :120º, Control : DmX512 Channel : 4 CH, Power Input : DC 24V with external driver, Surge Protection : Inbuilt surge protection 2KV-4KV(Additional if required will be added as per the requirement), Fixture will be suitable to operate in a temperature range of 0°C to 50°C , LED life time should be at least 50,000 burning hours at L70 at 25 degree centigrade. Luminaire is inclusive of Integral male/female waterproof connectors with structures in pre wired conditions as per IS standard. LED Makes should be CREE, LumilLED, Osram, Seoul, Epistar, Nichia or equivalent with the engineer or 3rd party testing laboratory approval i/c SITC of Aluminium Profile for Neon flex
SITC of DC power driver for the above Lights, Power : 200W, Input : AC 110-240V AC, 50Hz, Output : DC 12/24V, Protection rating, IP67, Surge protection : LL 4KV, LE 6KV
DMX Controller- Supply, installation, testing and commissioning of DMX Controller for the system including address writer and programming the DMX controller with the suitable designs as decided by the Engineer-in-charge/client department ( not less than 10 nos designs) and all other accessories required for the running of the system Controller should have Input Power 5-5.5V DC 0.6A and Output Protocol DMX512 with 4 universe, 2 universe should work in Stand Alone Mode and 2 universe should work in live mode with laptop/ tablet / computer. The universe should be expandable from 2 to 4 DMX512 universes. It should be compatible for Programmability with PC, Mac, Tablet, Smartphone by using USB & Ethernet. Dmx controller should have network controllability feature to control the scene remotely through LAN and triggered via UDP packets on port 2430. It’s must have Connections Type C USB, XLR3, Ethernet, battery. There should be provision for Memory microSD card. Device should have Intuitive backlit keyboard with 10 presents and also have provision of keypad on device for changing scene manually from device. Device should be capable to work on Extended triggering possibilities (TCA) & also have Smart Upgrade Technology (SUT). It is an IP 20 unit and has an Operating Temperature of 0°C to 50°C.OS Requirements for the controller is Mac OS X 10.8-10.12, Windows 7/8/10/11. Standards should be EC, EMC, ROHS. The controller should have a variety of features including 2048 DMX channels, clock/calendar, iPhone/iPad /Android remote control, Ethernet facilities, dry contact port triggering and multi-zone SD card memory. Network synchronization of one area across hundreds of universes with the possibility of 99 scenes across 5 areas with auto clock triggering for sunrise and sunset and as per the festivals for specific occasions. Device should be equipped with meta clamp to mount on wall with data enablers and splitters as required. To be provided with IP 66 enclosure if installed in external environment.
DMX decoder - Supplying, installation, testing and commissioning of highquality DMX decoder, Power Input : DC 24V etc complete as required.
Splitter- Supply of RDM-6Wall Splitter, should be able to provide 6- output DMX/RDM splitter with DMX/RDM pass- through supporting bi-directional communications for discovery,addressing and DMX control of Ethernet/DMX products.This unit takes the incoming DMX/RDM signaland splits the signal into six separate output channels allowing for expanding the number of devices controlled from 32 to 6x32. The output terminals are electronically isolated from the input & RDM-through port and share a common ground reference. All six output ports have an independent output driver to boost the DMX/RDM signal. Surface or DIN-rail mountable, Isolated DMX/RDM Input/Outputs,Automatic switching between DMX and RDM mode for auto- discovery, Environment-IP20, Interior applications, Finish/Color- Polycarbonate, Certification: CE Certified. DMX Splitter/Booster etc. as required.
Signal Amplifier - Supplying Installation, Testing and Commissioning of Signal Amplifier to boost the Signal, IP 65 rated module to enhance the depleting DMX Signals, should have IP 66/67 rates inbuilt connectors compatible with Luminaires. It should be offered with inbuilt electronic circuit for functioning. No external LED driver needed etc., complete as required.
SITC of IP driver box made up of PVC / UPVC for the internal terminations and external outgoing connecting points, with required PVC / brass glands, Optional suitable size MCB fitted for control outgoing circuits.
Supplying and Fixing of 5 pin XLR Male/Female connectors having 5 pole cable connector, Male/Female connector with improved latch, cage type contacts, "solder stop" for easy soldering, and additional ground contact for best contact integrity between chassis and cable connector. More durable housing for maximum reliability etc as required.
Programming charges as per site conditions or client's approval (18 scenes ).
Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
Supply and erection of XLPE/ PVC insulated PVC sheathed (5 core) unarmoured copper conductor cable (ISI marked) confirm to IS:7098 (PART-I), 1988 loose in the existing trench or pipe with suitable size of copper thimbles/lugs complete in all respect as desired by the Engineer-in-charge:-
Overall size 1.5sq.mm (5 Core)
XLPE INSULATED ARMOURED CABLES (LOOSE):
Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-
Overall size 10sq.mm (4Core) Armoured (Loose)
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's:-
Supply and erection of sheet metal double door Phase segregated distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 3Nos. shrouded neutral bars, 3Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label, compartmentalizing each phase (separated incomer, sub incomer & outgoing) and of required no. of ways for mounting FP MCB's as incomer, DP/RCBO's/RCCB's as sub MCB's as incomer, DP/RCBO's/RCCB's as sub incomer and SP MCB's as outgoings in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:-
TP&N Double Door Phase Segregated Distribution Board 4 way each
MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed
Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:-
PVC Flexible Pipe 25 mm dia.
Supply and erection of Compression glands, Locking arrangement, Checknuts for PVC flexible pipe complete with as required:-
PVC compression Socket gland 25 mm dia.
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:
Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-
Double Walled Corrugated HDPE Pipe 50/38 mm
G.I. EARTHING:
Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling).
Earthing with 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe with G.I. reducing socket 50mm x 15mm (upto 14 Metre in length)
G.I. EARTHING WIRE/ ROPE (AS ADDITIONAL LENGTH):
Fixing additional length of earthing with G.I. wire/ rope in G.I. pipe (Flushed in wall and floor) with sockets, elbows and Steel hooks including the cost of cutting and filling up of chases (with finishing the surface):-
Additional length G.I. wire 8 S.W.G. (4mm dia.) in 15mm dia. G.I. pipe (On Surface)
BOLLARDS
Supply, Installation, Testing and Commissioning of 800 mm long 11 W LED IP 65 Bollard , Housing made of extruded aluminium for excellent heat dissipation ,Weather-proof and rust-free luminaire with pure polyester powder coating,Symmetric glare-free light distribution with a polycarbonate diffuser,High-efficacy LEDs for optimum energy consumption, Potted driver and accessories pre-wired up to terminal block, having base plate with holes for direct mounting complete with all accessories including preparation of finished CC foundation with suitable size HDPE pipe for cable entry and exit, electrical connections for incomming and outgoing cables etc complete as per requirement at site (The rate must include junction box/terminal box suitable for incoming and outgoing cables i/c termination and other accessories and suitable earthing system). Lumen Efficacy of LED>110Lm/W @ 4000 K color temperature ,PF ≥0.95, THD ≤10%,Input Voltage Range 140-280 V, 3 KV Inbuilt Surge Protection,50,000 Hrs LED life with L70 criteria.
NEON FLEX STRIP LIGHT
Supply, Installation, Testing & Commissioning of 16mm X 16mm of 5 meters length Mono Color CCT : 3000 K of 70 W Flexible and encapsulated LED Strip light with Non- Integral driver. The luminaire’s shall be made of Silicon extrusion with high-efficiency, high grade appearance, soft bend flexibility & Option of Top bend , the same shall be so designed. The luminaire shall have silicon glue between optical cover & LED chamber to ensure proper IP67 protection. Brand name shall be embossed / printed on each an every light fixtures. CCT 3000 K and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.The Non Integral driver shall be installed in suitable Junction Boxes IP 66/67 “weather proof”, for outdoor installation along with IP 67 Gland & lugs Cable Termination complete as required.
BUSH LIGHTS
Supply installation,testing & commissioning of 9W LED BUSH LIGHT having Graphite grey powder coated integral aluminium housing.The Die-cast aluminium housing comprises Warm White (WW) COB LED and reflector.COB LED housing covered with die- cast aluminium ring with weatherproof gasket and toughened glass.LED Used shall be COB type CCT up to 3000K ±250K,IP65. Luminaire is wired with inbuilt driver with 5kV surge protection and should be constant current type with operating Voltage Range of 140 to 280V AC,PF>90,50Hz.Adjustable mounting bracket with spike should be provided for easy to focus the object.2 nos., Ø8mm holes should also be provided on adjustable mounting bracket for surface mounting. Luminare shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.
MINI FLOOD LIGHT
Supply Supply installation,testing & commissioning of 4000K Circular Mini Flood Light with Integral driver. The luminaire’s shall be made of Extruded aluminum housing powder coated with toughened glass in Dark Gray color.The complete luminaire has IP65 & IK06 protection and it comprises of high purity integrated poly carbonate Lens.The LEDs shall have minimum CRI ≥70 (White LED) & shall have SDCM≤5. The luminaire shall have wattage 40W and shall deliver 3600 lumens. Beam angle of the Luminaire shall be 30 deg .Fixture shall operating temperature range of 0°C to 45°C. Input Voltage Range of 140 - 280V AC.. The luminaire shall have declared life of 50,000 burning hours at L70.Luminaire and Driver must be made in India with same brand. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with technical bid. LM80 , RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire. Brand name shall be embossed / engraded on each an every light fixtures. Luminare, Driver and controller should be with same make and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.
FLOOD LIGHT
Supply and erection of LED Flood Light 250 watt, AC supply voltage 140-270 volts, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED (with wattage 1 to 5 watt) with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No: AT/2021/GL/1410-1422 Dated: 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.
XLPE INSULATED ARMOURED CABLES (LOOSE)
Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-
Overall size 6 sq.mm (4Core) Armoured (Loose)
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:
Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-
Double walled corrugated (DWC) HDPE pipe 63/51mm (outer/ inner dia.)
Supply and erection of heavy duty Aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections etc. completely:-
Aluminium thimble cable Core size 4 -6sq.mm
Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections:-
Brass Gland for Aluminium cable 2/3/4 Core size 6sq.mm
PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
Overall size 1.5sq.mm (Un-sheathed)
SHEET METAL CUBICAL PEDESTAL, TOWER STRUCTURES, HT & LT LINE ITEMS, MS CHANNELS, BRASS GLANDS, ALUMINIUM & COPPER THIMBLES:
Supply and erection of M.S. Channel bracket made from 100mm x 50mm of length 600mm and height 600mm with M.S. angle iron 40mm x 40mm x 5mm for installing metal halide flood light fitting on it. Bracket should be fixed/ welded with the existing pipe of cover shed. The bracket should be painted with one coat of primer and two coats of approved paint.
Supply and erection of SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772 (Recessed/ On surface), robustly constructed, safe & shock proof, rust & tamper proof of suitable inner & outer dimensions with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB's) complete in all respect as approved and desired by the Engineer In-Charge at site:-
SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772, inner dimensions 200mm x 140mm x 95mm with hinged water tight cover with locking arrangement
SHEET METAL CUBICAL PEDESTAL, TOWER STRUCTURES, HT & LT LINE ITEMS, MS CHANNELS, BRASS GLANDS, ALUMINIUM & COPPER THIMBLES:CUBICAL PEDESTA
Supply and erection of Sheet metal cubical pedestal made from 50mmx50mmx6mm thick MS angle iron frame with 5 sides welded & covered with MS sheet 2mm thick & front side hinged with 4" hinges & locking system with single/ double door openable placed on MS strip of size 12.5mm x 2.5mm thick welded with MS sheet, 4Nos. legs of 50mmx50mmx6mm thick MS angle iron each of 600mm long with MS sheet 100mmx100mmx6mm thick at the bottom end of the legs. Front door welded x-sectionally with MS flat 25mmx5mm. The front side with MS sheet each 75mm wide & a bend of 75mm width outwards & inwards on all sides with tappered top 200mm high and pedestal with 4 Nos. supporting members each of MS flat 50mmx6mm thick according to cubical size duly welded & complete pedestal to be painted with 1 coat of red oxide & 2 coats of paint & bonding to the existing earth. The Pedestal platform should be filled with 1:2:4 cement concrete mixture and erected 150mm high from the top of the cement concrete platform. The job is to be completed as approved by Engineer-in-charge:-
Cubical Size 1200mm high, 900mm wide and 350mm deep with platform dimensions 1000mm x 450mm x 450mm
MS SHEET ENCLOSURE FOR MCCB's: Supply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shall be made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/top with cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:-
MS Sheet Enclosure having provision for MCCB 40-160Amp.with extended rotary handle (Approx. Size 500mm x 300mm x 200mm)
Street Light Controller (For Three Single Phase Circuits) with 3 Nos. Three Pole Power Contactors 40A, 1 no. aux. contactor 6 amp. (2NO+2NC) with coil voltage 220V AC, 3 Nos. MCB 2 Pole 40amp. (C-Curve,10kA) & petty material (Din rail, 2 Nos. 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts)
G.I. EARTHING:
Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling).
Earthing with 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe with G.I. reducing socket 50mm x 15mm (upto 14 Metre in length)
G.I. EARTHING WIRE/ ROPE (AS ADDITIONAL LENGTH):
Fixing additional length of earthing with G.I. wire/ rope in G.I. pipe (Flushed in wall and floor) with sockets, elbows and Steel hooks including the cost of cutting and filling up of chases (with finishing the surface):-
Additional length G.I. wire 8 S.W.G. (4mm dia.) in 15mm dia. G.I. pipe (On Surface)
LED Display Signage
Supply, Installation, Testing and Commissioning (SITC) of Signage spec: size of letter 450 mm as per design letters size of letter 450 mm as per design letters Acrylic with powder coat pipe acrylic th powder coat pipe acrylic 4mm Thick a grade led samsung- outdoor grade outdoor grade smps - highlite /ads
P3 Outdoor LED Display
Supply and installation of P3 outdoor LED display with SMD 1921 (1R1G1B) LED configuration, having a cabinet with a resolution of 128 × 128 pixels per cabinet and pixel density of 65,536 pixels/m². The display shall provide a brightness level of 6000 nits with IP65 waterproof protection suitable for outdoor applications. The system shall operate on 16 scan drive mode with maximum power consumption of 800 W/m² and average power consumption of 600 W/m². The cabinet shall be constructed using die-cast aluminium or iron material with a weight ranging between 10–18 kg. The display shall support a refresh rate of 3840 Hz and operate on AC 220–240V, 50/60 Hz power supply, with G-neng power supply units or equivalent. The system shall be integrated with NovaStar receiving cards or equivalent. The display shall provide a wide viewing angle of 140° with 20-bit grayscale performance and an optimal viewing distance ranging from 3.9 m to 100 m. The operating temperature range shall be –20°C to +50°C, with storage/environment temperature up to 0°C to +80°C. The cabinet shall allow ±10° stitching angle adjustment. The LED display shall have a lifespan of 100,000 hours and shall be supplied with suitable packaging in flight case or wooden case for safe transportation.
Structural steel work
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
Water Column Fountain for 2 nos. Waterbodies, each of size 20 mtr x 2mtr:-
SITC of Water Columns Fountain comprising of 12 nos. Column Jets in a line. Each Water Column consists of nozzles made of Brass Chrome Plated, fountainhead made of aluminium alloy - expoxy coated, Brass BJRC for directional adjustments, a gunmetal ISI mark wheel valve (Sant/Zoloto/Leader make- ISI Mark) & necessary galvanised steel fittings. Manifold/Pipework made from Galvanised steel Pipe, Jindal make “B” Class ISI Mark with accessories like flanges, sockets, pipe stands etc. NRV of C.I./GM on each pumpset delivery, as required of Sant/Zoloto/Leader make ISI Mark. Approx. height of water effects: 1 - 1.5m. All Galvanised Steel and Mild Steel materials shall be hot dip galvanised in factory after doing necessary fabrication work. Make of fountain: ALT/A.M. Irrigation System/ Bharat Engineers
SITC of Monoblock type submersible pump set of Following Capacity (Three phase, 50Hz, 415- 380V AC) with proper completion of work as per direction of E/Ic. Pump: Kirloskar/Crompton Greaves/Texmo/ CRI Make. Suction filter for pump: Filter body & filter mesh made from AISI 304 standard stainless steel. 10 HP capacity
Fountain's Electrical Outdoor Panel (Body made from 16 gauge MS Sheet- Powder Coated):
SITC of specialised Outdoor type Electric panel for fountain which includes control arrangement for fountain's pumpsets and lights comprises of: 1. Contactor 25 Amp‐ 02 Nos (Make: L&T/ Schneider/ Siemens/GE) 2. Single Phase Preventer‐ 02 Nos (Make: Bentex/ Selec/ GIC or equivalent) 3. Incomer Main Switch 62 Amp‐ 01 Nos (Make: L&T/ Schneider/Siemens/ GE) 4. Overload Relay 6‐ 18 Amp‐ 02 Nos (Make: L&T/Schneider/ ABB/ BCH or equivalent) 5. MCB for motor 32 Amp‐ 02 Nos (Plaza/ Anchor/ ABB/ Havells/Legrand or equivalent) 6. MCB for Lights 6 Amp ‐01 Nos (Plaza/ Anchor/ ABB/ Havells/Legrand or equivalent) 7. Push Button On/ Off switches (Red/ Green)‐ 04 Nos. 8. Overload Indicator ‐ 02 Nos (Make: Eaton/ Siemen or equivalent) 9. Single Phase Indicator‐ 02 Nos (Make: Eaton/ Siemen or equivalent) 10. 3 Phase indicator RGB‐ 01 Nos (Make: Eaton/ Siemen or equivalent) 11. Voltmeter‐ 01 Nos. (Make: Motwane, Innova, Fluke or equivalent) 12. Ampere Meter‐ 02 Nos (Make: Motwane, Innova, Fluke or equivalent) Make of Panel: ALT/A.M. Irrigation System/ Bharat Engineers
Waterproof Lights for Fountains
SITC of waterproof 12V LED lights (RGB/White/Warm White). Complete light body made of AISI 304 standard stainless steel, total 27 watt power leds. Toughened glass with seal. AISI 304 standard stainless steel cable gland. All external nuts and bolts are of AISI 304 standard stainless steel. Adjustable mounting bracket is made of AISI 304 standard stainless steel. IP 68 compliant. Light complete with clamp, waterproof hardener & epoxy. All 'in pool' connections shall be fully waterproof. Make of Lights: ALT/A.M. Irrigation System/ Bharat Engineers
SITC of waterproof LED lights' Sequencer
Cables:
Providing & laying of Copper conductor flexible cable for submersible pumps- 2.5mm x 3 core (flat cable) i/c end terminations complete as required. Make: Havells/Finolex/ Polycab.
Providing & laying of Copper conductor flexible cable for Fountains' Lights - 1.5mm x 4 core. i/c end terminations complete as required. Make: Havells/Finolex/ Polycab.
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed
G.I. EARTHING:
Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling).
Earthing with 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe with G.I. reducing socket 50mm x 15mm (upto 14 Metre in length)
G.I. EARTHING WIRE/ ROPE (AS ADDITIONAL LENGTH):
Fixing additional length of earthing with G.I. wire/ rope in G.I. pipe (Flushed in wall and floor) with sockets, elbows and Steel hooks including the cost of cutting and filling up of chases (with finishing the surface):-
Additional length G.I. wire 8 S.W.G. (4mm dia.) in 15mm dia. G.I. pipe (On Surface)
BULLET CAMERA-Supply, Installation, Testing, commissioning of 5MP Bullet Camera with 2.8-12mm Motorized Varifocal lens, 1/2.8" SONY - CMOS 5MP Active Pixel, Minimum Illumination - Color - 0.01 Lux @F1.2, Focal Length - 2.8mm — 12mm, Focus Range - 0.3m to infinity, Aperture (F#) - F1.6-F2.8, Iris Type - Motorized Varifocal Iris, IR Range - Up to 50m, IR Led Wavelength - 850nm, IR Switching - Auto/ Manual, Audio IN - 1, Audio OUT - 1, Two-way Audio -Supported, Audio Compression - G.726 and G.711g, Alarm In - 1 (Phoenix type connector), Alarm Out - 1 (Phoenix type connector), SD Card - Up to 512GB, Camera Adjustment Angle - Pan: 0° to 360°, Tilt: 0° to 90° , Rotate: 0° to 360°, Available Resolutions - 2592 x 1944, 2592 x 1520, 2048 x 1536, 1920 x 1080, 720p, D1, 2CIF, CIF, Max Resolution - 2592 x 1944, Bitrate - 128 kbps-16Mbps, Bitrate Type - CBR, VBR, Video Compression - H.265, H.264, MJPEG, Frame Rate - 1-30fps, Shutter Speed - 1/15s -1/100000s, Adaptive Streaming - Yes, ONVIF Profiles - S, G, and T, Edge Recording - Yes, Alarm Recording - Pre and Post, Motion Recording - Yes, Time Triggered - Yes, WDR True - WDR (120dB), SNR - >70dB, Storage - NAS, SD Card, Certifications - NDAA Compliant, BIS, CE, IP67, FCC Part-15 Subpart - B, ONVIF S, G & T,IK10,UL, NEMA 4X**, STQC Certified with OWASP ASVS 4.0L2, SIRA. Make: Matrix/ Bosch/ Honeywell, Norden.
PTZ CAMERA-Supply, Installation, Testing, commissioning of 2MP PTZ Camera, Image Sensor 1/ 2.8” CMOS, Minimum Illumination Color: [email protected], 0Lux with IR Shutter Speed 1/15s to 1/10000s, Day and Night Yes, Wide Dynamic Range 120dB, Optical Zoom 38x, Digital Zoom 16x, ocal Length 4.4 mm – 169.4 mm, Zoom Speed Approximately 6s from wide to tele at Max Speed, Aperture Range F 1.6 – F4.9, IR Range Up to 300m, IR irradiance Angle Adjustable by Zoom, Video Compression H.265/H.264/M-JPEG, Video Bitrate 128kbps-16Mbps, Audio Compression G.726 ,G.711 a-law and u-law, Audio Bitrate 128kbps-16Mbps IMAGE, Max Resolution 2MP – 1920×1080 5MP – 2592 x 1944, Stream Profiles Four streams support 5MP, Profile 1:- 2592 x 1944p/ 2592 x 1520/ 2048 x 1536/ 1920 x 1080/ 720P/ D1/ 2CIF/ VGA/ CIF/ QCIF @30fps (H.264/H.265), Video Analytics Motion/No Motion Detection, View Tamper Detection, Trip/No Trip Detection, Object Intrusion/Zone Intrusion, Loitering, Missing/ Object Counting, Abandoned Object, Audio Exception, Alarm In, Protocol TCP/IP, UDP, HTTP, HTTPs, DHCP, DNS, DynDNS, RTP, RTCP, RTSP, RTSPS, PPPOE, SMTP, NTP, SNMP, HTTPS, FTP, SMTP, 802.1x , IGMPv2& v3, ICMP, IPv4,IPv6,QoS Layer 3, CIFS,SSH, ARP, Communication Interface 1 RJ45 10/100 Self Adaptive Ethernet Port, Built-in Micro SD card slot up to 512GB, Power Supply 24VDC 2.5A , AC(Optional), Power Consumption Max 25W, Protection IP67. Make: Matrix/ Bosch/ Honeywell
NVR-Supply, Installation, Testing and comissioning of 16 Channel NVR with 4K Support and 2 HDD Slot, 32 IP Channel Inputs; HDMI, 1/1 Audio I/O and 2/1 Alarm I/O, 12MP, 8MP, 5MP, 4MP, 3MP, 2MP, 720p, D1 and CIF Recording Resolution, 4x 4K/ 10x 3MP/16x 1080p Local Decoding, 4 SATA HDD Support (Maximum 10TB Capacity per Slot), Save Storage Space with Adaptive Recording and Camera-wise Recording Retention, SMS & Email Notification, Video Pop-up and Alarms, 512 Mbps Throughput - 256 Uplink, 256 Downlink, NAS Support: 2 NAS (CIFS, NFS), Mobile Viewer Application Should Support Calling from Mobile App Feature Where a Mobile Number Can be Added Per Camera in the Device and The User Can Directly Call a Concerned Person by Just One Click on Camera View from Mobile(without any SIM card in NVR), The device should be capable of acting as a Master device and should be able to Add,View,Playback and Configure at least 20 other connected slave devices (NVRs) camera's from the Local View via HDMI, without need of any Server/workstation., BIS, FCC. Make: Matrix/ Bosch/ Honeywell
HARD DISK-Supply, Installation, Testing and comissioning of 10 TB Hard disk Make: WD/Seagate/Toshiba
Supply, Installation, Testing and comissioning of Switch should be Web Manged, Should have 8 port 1000BASE-T with 4 Port 1000BASE-T PoE PoE power budget 160 Watt or higher, Maximum Per port PoE Power 30 WattIEEE 802.3 10BASE-T Ethernet, IEEE 802.3u 100BASE-TX Ethernet,IEEE 802.3ab 1000BASE-T Ethernet, IEEE 802.3az EEE support,IEEE 802.3x flow control,IEEE 802.3z 1000BASE-X,IEEE 802.1p CoS,IEEE 802.3af PoE, IEEE 802.3at PoE Plus, IEEE802.1Q VLAN Tagging, Minimum 8 VLAN supportPort based VLAN, IEEE802.3ad link aggregation should be MAC based Switching Capacity 16 Gbps,Packet buffer 192KB,MAC address support 4K Jumbo frame support 9K, Should support loop detection,Should support Broadcast storm control QoS Support (WRR and strict priority) Port based QoS 20 Multicast group or higher, Maximum power consumption 72W,Operating temperature 0°C to 40°C Storage Temperature -40°C to 70°C Certification: CE, FCC, C-Tick, , LVD EN60950-1, ROHS compliant.Should be built-in IEEE 802.3az Energy Efficient Ethernet (EEE) Make: Alied /Juniper / Netgear/ Zyxel.
Supply, Installation, Testing and comissioning of Layer-2 POE plus Gigabit Ethernet 1RU chassis with 24 PoE 10/100/1000 BaseT ports and 4 Gigabit SFP ports. Includes an internal AC power supply 370W atleast or higher power budget) with a power cord, manuals access card, and RJ-45 to DB-9 adaptor.The Access Switch should have 4 ports of 1 G SFP.The Access Switch should provide Non-Blocking switch fabric capacity of 56 Gbps or more. L-2 switch should provide wire-speed packet forwarding of 41 Mpps or more. L-2 Switch should support min 16K MAC addresses and min 4000 active VLANs. Make: Alied /Juniper / Netgear/ Zyxel.
Supply, Installation, Testing and comissioning of 65" 4KUHD resolution LED Display with Android 11, 400 nits brightness, Cortex A55 1.3Ghz processor, Mali G31 MP2, Open GLES3.2, 2 GB DDR RAM, 16 GB Memory, Wifi Type support both 2.4 & 5G Standard, Dolby Audio, Built in Wifi and Cromecast, HDMI CEC, HDMI ARC, Built-in Bluetooth, Hotel mode, Meeting Mode,20W built in speakers, HDMI 2.0 X 2, AV X 1, USB X 2, RJ45 X 1, SPDIF Out x 1,24/7 operational. Make: Panasonic /Samsung /LG/Sony.
Supply, Installation, Testing and comissioning of 5 Mtr HDMI cable Connectors at both ends Make :-Key Digital/Manhattan/ Kramer
Supply, Installation, Testing and comissioning of 22U Equipment Rack with provision for housing all control equipment with front & rear door, Blower for cooling and proper locking arrangements and as per the specifications, complete in all respect upto the entire satisfaction of Engineer - in - Charge of the work. Make: Comrack/ Valrack/ Netrack.
Supply, Installation, Testing and comissioning of 9U indoor IPV5 rated rack with 2 side FAN with 3 socket PDU with 15 AMP DP for power surge safty. With pole mount accessories. Rack should be certified. Make: Comrack/ Valrack/ Netrack.
Supply, Installation, Testing and comissioning of CAT 6 UTP Cable.Transmission frequency of 250 MHz (Minimum),cable Should be 4 pair and Cable should be jacket FR PVC Lbp 69% required with certification report. Make: Panduit/R&M/Systimax.
Supply, Installation, Testing and Commissioning of 3 KVA Online UPS Overvoltage cut-off device (OVCD),Support for up to 42 AH external battery cabinets, Generator Compatible with Wide Input. Wide Input Voltage window (110 – 280Vac) for Indian Environmental Condition and for Optimized Battery Performance. UPS would support SNMP Manager and web browser On Line With 1 hour Backup. MAKE APC/ LIBERT / EINOVA / DELTA/Emerson
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed
PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
Overall size 1.5sq.mm (Un-sheathed)
3-STEPPED STEEL TUBULAR POLE:
Supply and erection of 3-Stepped steel tubular swaged and welded pole (410-SP- IS: 2713- (PART-II)-1980 (Steel tubes confirming to IS: 1161-1979, UTS 42 kgf/ Sq.mm) to fix up to a required planting depth below ground level in a hole of excavation about 45 cm dia. and suitable depth to fill up to 15 cm below G/L with 1:2:4 cement concrete mixture including painting of pole with two coats of approved aluminium paint as required:-
Overall length 7 metre, with planting depth 1.25 metre, length of sections 4 metre, 1.5 metre and 1.5 metre (Bottom, Middle and Top respectively), Outer dia and thickness of sections 114.3mm x 4.5mm, 88.9mm x 4.05mm and 76.1mm x 3.25mm (Bottom, Middle and Top respectively) with approximate weight 73 kg. (410 SP-2) and base Plate weight 7.5 kg. of size 12mm thick about 30 cm dia
Supply, installation, Testing & Commissioning of 'Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating of 50 KVA , 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor,including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing, test report OEM manual,Geo-Tag of manufacturing location, rating plate as per relevant IS Code etc. and consisting of the followings:
(A) Diesel Engine:
Turbocharged Diesel engine 4 stroke water cooled, multi cylinder,dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Degree C, 50% RH & at 1000 Meter MSL , capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV + or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as per CPWD specifications. (B) Engine mounted Instrument Panel fitted with and having digital display for following:
i) Start-stop switch with key
ii) Water temperature indication
iii) Lubrication oil pressure indication
iv) Lubrication oil temperature indication
v) Battery charging indication and Voltage indication
vi) RPM indication
vii) Over speed indication
viii) Low lubricantion Oil trip indication
ix) Engine Running Hours indication
x) Fuel Level
(C) Alternator:
Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation.
(D) Base Frame & Foundation:
Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer.
(E) FUEL TANK:
Daily service fuel tank of suitable liters capacity as per CPWD Specifications,fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class 'C' pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications.
(F) Exhaust System:
Dry exhaust manifold with hospital convertor.type exhaust silencer and catalytic convertor.
(G) Starting System:
12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set.
(H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection/connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof & dust-proof conforming to IP-65 protection. The enclosure shall be as per CPCB IV + or better norms etc. and as per PWD specifications.
PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE: Supply and erection of XLPE/ PVC insulated PVC sheathed (10 core) unarmoured copper conductor cable (ISI marked) confirm to IS:7098 (PART-I), 1988 loose in the existing trench or pipe with suitable size of copper thimbles/ lugs complete in all respect as desired by the Engineer-in-charge:- (From DG Set to AMF Panel)
Overall size 2.5sq.mm (10 Core)
COPPER EARTHING
COPPER EARTHING (Upto 14 metre in Length):- Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- (Body earthing & Neutral Earthing)
Earthing with 25mm x 5mm Copper Tape (upto 14Metre in Length) (Body earthing & Neutral Earthing: 4Nos. for DG Set 250KVA)
Additional Length 25mm x 5mm thick Copper Tape
MAIN LT PANEL:
Fabricating, Installing, Testing & Commissioning of Main cum automatic mains failure control including auto by-pass panel, suitable for 50 KVA Main Supply and 50 KVA silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, KVARH & provision for overload, short circuit, restricted earth fault, under frequency, control cabling from AMF panel to diesel engine and elsewhere if required, all complete and inter locking including the following:sheet steel cubicle type panels fabricated from 14 guage thick CRCA sheet, dust and vermin proof, indoor type MV Panels with hinged lockable doors fabricated from 2mm thick CRCA sheet, suitable for 415V, 3 phase 4 wire 50Hz AC supply with rear / bottom access for cable alley and with segregated bus-bar chamber and including supplying and fixing following switchgears, meters and accessories, inter-connections, bonding to earth, bottom base channel of MS section not less than 100mmx50mmx5mm (thick). Fabrication shall be done in transportable section ,entire panel shall have a common earth busbar at rear with 2 Nos earth stud cable alleys, cable gland plates powder coated painting of approved shade after antirust treatment (with min seven tanks ) and marking as specified. Switch boards complete as per schematic diagram:
Colour: Gray Powder Coated, as per approved sample.
Note: All MCCBs of 250 amps and below rating shall be provided with thermal magnetic release & MCCBs above 250 amps rating shall be provided with Microprocessor based release. (All MCCBs shall be fitted with extended type rotary handles and spreader links)
1Nos, 125 Amps. Four pole Moulded Case Circuit Breaker of fault breaking capacity 25 KA (ICS=100% ICU up to 433 V) complete with extended Rotary Mechanism and Spreader Link Set with microprocessor release for O/L, S/C & E/F protection.- Mains Supply
1Nos, 125 Amps. Four pole Moulded Case Circuit Breaker of fault breaking capacity 25 KA (ICS=100% ICU up to 433 V) complete with extended Rotary Mechanism and Spreader Link Set with microprocessor release for O/L, S/C & E/F protection.- Mains Supply
1 Nos. 160 Amp. 415 volt AC 3 duty 4 pole contactor - 2Nos
1 No. 160 Amp 415V, AC , 4P Manual Changeover with Operating Handle
2 Nos. over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay.
3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering
Energy analyser unit to indicate current voltage frequency power factor and KWH
Indicating lamps for load on mains and load on set
Fuse for instruments
Main supply failure monitor
Supply Failure Timer
Restoration Timer
Control unit with three impulse automatic engine start/stop and failure to start lockout
Impulse counter with locking and reset facility.
ON/OFF/Control circuit switch with indicator
Audio/Video annunciation for.
(i) High water temperature
(ii) Low lubricating oil pressure
(iii) Engine over speed
(iv) Engine fails to start
(v) Full load/maximum load warning
BUSBAR
TPN aluminum bus bars of minimum of 500 Amps capacity with heat shrinkable colored sleeves and I/C DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc.
OUTGOING BREAKERS
02 Nos 63/100 Amp Four Pole Moulded Case Circuit Breaker of 10 KA breaking Capacity with Thermal Magnetic release for O/L & S/C protection and neutral link .
04 Nos. 40 Amp Four Pole Miniature Circuit Breaker of 10 KA breaking Capacity .
04 Nos. 63 Amp Four Pole Miniature Circuit Breaker of 10 KA breaking Capacity .
G.I. EARTHING:
Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling).
Earthing with 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe with G.I. reducing socket 50mm x 15mm (upto 14 Metre in length)
G.I. EARTHING WIRE/ ROPE (AS ADDITIONAL LENGTH):
Fixing additional length of earthing with G.I. wire/ rope in G.I. pipe (Flushed in wall and floor) with sockets, elbows and Steel hooks including the cost of cutting and filling up of chases (with finishing the surface):-
Additional length G.I. wire 8 S.W.G. (4mm dia.) in 15mm dia. G.I. pipe (On Surface)
INDOOR LT CABLES, CABLE TRAY, DWC PIPE , BRASS GLANDS & THIMBLES:
XLPE INSULATED ARMOURED CABLES (LOOSE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-
XLPE INSULATED ARMOURED CABLES (ON SURFACE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:-
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1/2Meter below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-
CABLE TRAY: Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:-
Cable Tray Size 150mm x 50mm x 50mm (2mm thick)
Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections:-
Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:-
Supply and erection of heavy duty Copper thimbles/lugs for cable end termination duly crimped including making necessary connections etc. completely:-
Copper thimble cable Core size 4 - 6sq.mm
SAFETY EQUIPMENTS:
Supply & fixing of shock treatment chart both in Hindi & English for treating person suffering due to electric shock mounted on wall hooks.
Providing and fixing M.V. danger notice plate of 200 mm x 150mm, made of mild steel at least 2mm thick and vitreous enamelled white on both sides and with inscription in single red colour on front side as required.
Providing of set of 4 Nos. 9.5 Litre capacity GI bucket painted in post office red colour with prior coat of red - oxide paint and written with white paint 'Fire' and mounted on MS angle iron frame with bracket of appropriate size and capacity including filling sand etc.
Supply of First Aid box as approved by St. John Ambulance Brigade / Indian red Cross conforming to IS 2217 -1963.
Supply & fixing of fire retardant/ extinguishing Electrical insulated synthatic mat 1Mt. x 2Mt. of minimum 3.0 mm thick +/- 10% confirming to BIS: DOC NO. ET-02 (5440) meeting requirments of IS: 15652 :2006 (with upto date amendment),, suitable for all voltages not exceeding 33 KV and having minimum width of 1000 mm +/- 20mm and including supply of required quantity of adhensive/ compound and fixing the same at size as per site requirments.
Providing and fixing of 4.5 Kg. Capacity FIRE EXTINGUISHER,CO2 type as per IS:15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect
Providing and fixing of 6 Kg. Capacity FIRE EXTINGUISHER, ABC Powder type (stored pressure) asper IS:15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect
Providing Solar system
ON-Grid Solor System Supply, Installation, testing & Commissioing of Grid interactive PV System Solar Power Plant (i.e connected to utility grid) of Minimum 15KW including required quantities of SPV modules (High power density Perc Monocrytalline based single module of capacity +400 watt) formed into arrays, their mounting arrangement, Power conditioning units (i.e String Solar Inverter), required DC & AC distribution panels with surge protection units, cabling from terrace to main distribution board through Cable tray, Bi Directional Energy Meter, Required Chemical Earthing with copper bonded rods (i.e. 1 No for GI Structure, 2 Nos. for String Inverter, AC & DC Distribution System), Provision of Lightening Arrestor & 2 Nos. chemical earthing with copper bonded rods. Hot dip galvanized MS Mounting Structures should be designed to withstand the speed for the wind Zone of the location (150 Km/hr-170 Km/hr) Complete in all respect with transportaion, fabrication, labour & Civil Work etc. "Features:- (1) Solar PV Module Warranty 25 Years & Certified Under IS/IEC 61730 I & II, IS/ IEC 61701 & IS/IEC 14286 & IES 61215, BIS Certificates and MNRE, GOI Latest Specifications/ Standards (2) Power Conditioning Unit (String Solar Inverter) & Certified under IEC/EN 62109-1, IEC/EN 62109-2, EN 61000-6-2, EN 61000-6-3, IS/IEC 61683, EN 50530, IEC 60068-2-1, 2, 14, 30, EN 60529, IES 60947 Part I,II & III, IS 60947 Part I & II, IES 60227/ IS694, IES 60502/ IS1554/ BIS Standard and MNRE, GOI Latest Specifications/ Standards (3) Structure : 25 Years Service Life with AMC & Certified under IS 2062:2011 (4) Complete Plant Insurance for the period of 5 Years (Excluding Theft of the material) (5) Annual Maintenance Contarct for the period of 5 Years The Work will got done from approved MNRE (Ministry of New and Renewable Energy) / PEDA (Punjab Energy Development Agency) PSPCL Contractors. "
Provision for obtaning Electrical Connection from PSPCL (Service Connection Charger & Security) etc. which shall be paid to PSPCL.
Total
Note: Being a percentage tender, the bidder shall quote its price as at par or percentage above or percentage below the estimated total cost in the Bill of Quantities as specified.
GRAND TOTAL
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.54 MB
nit.pdf
Tender Documents • 21.42 MB
BOQ.xlsx
Additional Documents • 0.06 MB
Download all tender documents and submit your bid