DYCSTESCL
13 conditions · 2 needing a document upload
As Per Tender Document Attached.
As Per Tender Document Attached.
7 conditions · 2 needing a document upload
As Per Tender Document Attached.
As Per Tender Document Attached.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Supply, Installation, Testing and commissioning of Integrated Tunnel Communication Systems, OFC based industrial grade network system including laying of OFC & other cables for Railway network which includes tunnels and stations in Awangkhul-Noney section of Jiribam - Imphal new Railway Line project.
DyCSTE_C_SCL_2026_01_01~NFRCON
DyCSTE_C_SCL_2026_01_01
Open
Works - General
365 Days
Kamrup, Assam
₹0
₹78.3 L
3 Oct 2026
3 Oct 2026
13 Oct 2026
275 items across 4 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 12,99,68,859.34 | ||
| — | 3.00 | — | — | ||
| Supply of Master Unit for VHF simplex system as per RDSO specifications No. RDSO/SPN/TC/109/2023 version 1.0 with latest Amendment/Revision & attached technical specification to be provided at each station. The Master Unit will consists of (a) Off Air Channelised repeater and (b) Optical converter Unit having suitable number of ports to connect required number of Remote units through optical fibres. The VHF communication should be established in both block section without cross talk and interference. | — | — | — | 1,77,22,016.76 | |
| — | 15.00 | — | — | ||
| Supply of Optical Remote Unit for VHF simplex system requirements mentioned in tender as per specifications No. RDSO/SPN/TC/109/ 2023 version 1.0 with latest Amendment/ Revision and technical specs attached with main and stand by connections to Optical Master Unit. One ORU should be able to connect minimum three OMUs (two at stations and one at in between tunnels). | — | — | — | 5,75,96,551.65 | |
| — | 75.00 | — | — | ||
| "Supply of 3KVA/ 2.7KW True On Line Rack mounted UPS System.Phase: 1P Input - 1P Output Form Factor: 2U SizeDimension (W x D x H): 440 x 430 x 88mm (rack mountable)The UPS should have facility of remote monitoring and as per Technical specs." | — | — | — | 53,33,181 | |
| — | 75.00 | — | — | ||
| "Supply of Lithium Battery:Battery Configuration: 72V/42AHDimension (W x D x H) (+/- 2mm): 483 x 620 x 176mm (rack mountable)" | — | — | — | 1,16,36,031.75 | |
| — | 40.00 | — | — | ||
| Patch cord with connectors as per OEM requirement- 15 Mtrs of approved make. | — | — | — | 1,52,493.6 | |
| — | 1.00 | — | — | ||
| Supply of Voice Recording equipment as per RDSO Specification RDSO/SPN/TC/038/2002 version 2.0 with latest Amendment/Revision of approved quality. | — | — | — | 4,53,837.17 | |
| — | 1.00 | — | — | ||
| Supply of 1/2" RF Feeder Cable of approved make. | — | — | — | 2,54,149.21 | |
| — | 115.00 | — | — | ||
| Supply of N-Type Connectors for 1/2" Cable of approved make. | — | — | — | 1,75,331.3 | |
| — | 14.00 | — | — | ||
| Supply of 7/8" Leaky Radiating Cable fire retardant, as per specifications No. RDSO/SPN/TC/109/2023 version 2.0 or latest. | — | — | — | 1,60,11,382.94 | |
| — | 140.00 | — | — | ||
| Supply of N-Type Connectors for 7/8" Radiating cable of approved make. | — | — | — | 2,49,058.6 | |
| — | 2800.00 | — | — | ||
| Supply of Stainless Steel Clamps for 7/8" Radiating Cable anchored using SS Bolts and SS Anchor Fasteners (Stainless steel" shall be a Cr-Ni-Mo alloy or Cr-Ni-Mo-Ti alloy, material No. 1.4404 or 1.4571 according to EN 10088 resp. 316 S 11 or 320 S 31 according BS) of reputed make. | — | — | — | 24,91,216 | |
| — | 11200.00 | — | — | ||
| Supply of Nylon Clamps for 7/8" Radiating Cable using Stainless Steel Self-Anchoring Expansion Bolts of reputed make. | — | — | — | 65,46,624 | |
| — | 92.00 | — | — | ||
| Supply of Jumper Cables 1 mtr in 1/2"SF Cable with N-N /DM NM terminations as per OEM of approved make. | — | — | — | 3,50,735.28 | |
| — | 32.00 | — | — | ||
| 2way splitter of approved make. | — | — | — | 5,69,310.72 | |
| — | 25.00 | — | — | ||
| 10W Termination Load (PIM<=-150) of approved make. | — | — | — | 1,05,380 | |
| — | 25.00 | — | — | ||
| Supply, installation, testing and commissioning of 20dB attenuator for ORU. | — | — | — | 5,22,991.75 | |
| — | 25.00 | — | — | ||
| Supply, installation, testing and commissioning of 30dB attenuator for ORU. | — | — | — | 5,32,674.5 | |
| — | 60.00 | — | — | ||
| Supply, installation, testing and commissioning of DC blocker at ORU locations. | — | — | — | 4,34,201.4 | |
| — | 6.00 | — | — | ||
| Supply and installation of Leaky cable laying arrangement in security niches and Adit faces etc. Each set includes the following (as per approved drawing)- steel wire, dimension - 4 sq mm, material- SS304, quantity-5 mtr turn buckle, dimension- 8sq material-GI, Qty-1nos GI clamp, Material-GI, Qty-4nos. Cable Tie, Material-SS304, Qty-7nos Eye Screw. | — | — | — | 18,195.9 | |
| — | 65.00 | — | — | ||
| Supply and installation of Weather proofing and Wrap tapes. | — | — | — | 64,554.1 | |
| — | 24.00 | — | — | ||
| Supply of High Gain Directional Antenna in VHF Band at Portals of Tunnels. | — | — | — | 10,43,238 | |
| — | 2.00 | — | — | ||
| Supply of RF lightning and Surge Arrestor protection of approved make. | — | — | — | 23,628.4 | |
| — | 6.00 | — | — | ||
| Supply of Log Periodic Antenna in VHF Frequency Band of approved make. | — | — | — | 1,06,745.76 | |
| Lumpsum 459176.78 | 1.00 | — | — | ||
| System Architecture/technical Design to suit functional, technical and system requirements given in technical specs & Documentation with project team/ interfacing and client discussion for formalising design document. Design document for in- principle approval of Railway. Scope of design also includes defining the system values, parameters, block diagrams, diagrams, drawings, flow charts, location-wise equipment details etc., for VHF systems and the same shall be submitted by the contractor. After testing if any change in design required the same shall be incorporated and submitted to Railway for approval. | — | — | — | 4,59,176.78 | |
| — | 1.00 | — | — | ||
| Laying of RF Cable with Labelling with descriptions of antenna, component and accessories. | — | — | — | 7,790.71 | |
| — | 14.00 | — | — | ||
| Laying of 7/8'' LCX cable and required accessories on tunnel wall along with required accessories, with contractors tools, Plant, labour etc complete. | — | — | — | 60,09,432.24 | |
| — | 3.00 | — | — | ||
| — | 15.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
1.GCC-2022.pdf
ATTACHMENT
2.UpdatedGCC-2022updateduptoACS-12.pdf
ATTACHMENT
3.MakeinIndiapolicy.pdf
ATTACHMENT
4.TenderDocumentforTRCAwangkhulNoney.pdf
ATTACHMENT
5.Appendix1Annexures.pdf
ATTACHMENT
Appendix 2 Annexure 1
ATTACHMENT
7.Appendix2Annexure2inspectionschedule.pdf
ATTACHMENT
8.Appendix2Annexure3Technicalspecifications.pdf Appendix 2 Annexure 3
ATTACHMENT
9.RestofAppendix2.pdf
ATTACHMENT
6.Appendix2Annexure1projectdetailsAWA-NONEY.pdf
ATTACHMENT
8.Appendix2Annexure3Technicalspecifications.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .