Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.0 LAccepted-AOC 13 218 MASJID EXTEN SADAR BAZAR | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹18.1 L+₹9,803.35 (0.54%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹21.3 L+₹3.3 L (18.2%)Rejected-Finance 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹21.6 L+₹3.6 L (19.8%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹21.8 L+₹3.8 L (21.1%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
3 Sept 2024, 6:00 pmClosed
GE South Delhi Cantt-10
GE South Delhi Cantt-10
REPAIR/MAINT OF UG CABLES, LT PANELS, SECURITY LIGHTS, GARDEN LIGHTS AND CONNECTED ACCESSORIES AT MANESAR ARMY CAMP, DUNDAHERA MIL STN AND INDU BINOLA UNIVERSITY UNDER AGE E/M OF GE (SOUTH) DELHI CANTT-10
2024_MES_664025_1
GE/DS-46/2024-25
Open Tender
Civil Works
Item Rate
270 days
GE South Delhi Cantt
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE South Delhi Cantt
₹80,000
24 Oct 2024
4 Jul 2024
10 Sept 2024
4 Jul 2024
3 Sept 2024
18 Jul 2024
Amount
Supply and laying XLPE insulated armoured cable (heavy duty) electric cable with aluminium stranded conductor 1100 volts grade of following size after taking down old Unsv XLPE Cable/weisel aluminium overhead conductor including earth wire complete all as specified and directed by Engr-in-charge as follow :
10 Sqmm x 2 Core
16 Sqmm x 2 Core
25 Sqmm x 3.5 Core
35 sqmm x 3.5 core
50 sqmm x 3.5 core
70 Sqmm x 3.5 Core
95 Sqmm x 3.5 Core
300 Sqmm x 3.5 Core
Taking down of unsv LT Panel board with frame and fitting complete and supply, installing, testing and commissioning factory made LT ( 415 Volts, 50 Hz , 3-phase, 4 wire supply ) CPRI approved, factory assembled Outdoor Feeder Pillar type, weather proof, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated Aluminium bus bars of 300 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, ingress protection class ( IP-54 ) and made of 3.15 mm thick CRCA mild steel sheet and mild steel, Angle iron frame work made out of 40 X 40 X 6 mm ), front and rear opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FR wire of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey shade 7035. embedded in ground with and including blocks of PCC 1:2:4 type B1 of block size 30x30x30 cm comprising of the following:-
BUS BAR CHAMBER :- (a) 300 Amps 3 Strips & Neutral Strip 150 Amps, Aluminium conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings. INCOMING SUPPLY :- (i) MCCB 200 Amps 36 KA 4 Pole with Fixed thermal & magnetic release 415 volts , 50Hz,=01 No. INSTRUMENT FEEDER :- (a) Digital Multi Function Meter with LED display for measurement of Voltage, current, frequency, Power Factor, 96 X 96 mm, 3 Phase- 01 Set. (b) C.T's 200/5 A CL 1.0 Tape Wound- 01 Set. (Set of three) (c) Red, Yellow, Green Phase indicating Lights LED type 220 V AC- 1 Set. (Set of three). (d) Protection MCB 6 A SP C Series- 1 Set. (Set of three).
OUTGOING SUPPLY :- (i) MCCB 100 Amps 25 KA 3 Pole with Fixed thermal & magnetic release 415 volts , 50Hz - 04 Nos, Make of MCCB:- L&T/ Schneider / HPL/ Havells. The panel manufacturer should have following Govt. Approved Certificates: 1. Panel should be according to IEC-61439. CPRI Certification Degree of Protection IP-54 (IS/IEC : 61439 (Part-1), 2011 & IS/IEC : 61439 (Part-2) 2011) 2. Tempreature Rise (IS/IEC : 61439-1, 2011 & IS/IEC : 61439-2 2011) 3. CPRI Short Circuit IEC-61439-1 & 2 withstand strenght should be 70kArms for 1.0 Sec with intial peak of 154kApk 4. CPRI Certification IEC-61439-1 & 2 Rated current for short circuit not less than 6300 A with rated insulation voltage 660V 5. ISO 9001 CERTIFIED
Taking down of unsv LT Panel board with frame and fitting complete and Supply, installing, testing and commissioning factory made LT ( 415 Volts, 50 Hz , 3-phase, 4 wire supply ) CPRI approved, factory assembled Outdoor Feeder Pillar type, weather proof, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated Aluminium bus bars of 100 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, ingress protection class ( IP-54 ) and made of 3.15 mm thick CRCA mild steel sheet and mild steel, Angle iron frame work made out of 40 X 40 X 6 mm ), front and rear opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FR wire of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey shade 7035. embedded in ground with and including bocks of PCC 1:2:4 type B1 of block size 30x30x30 cm comprising of the following:-
OUTGOING SUPPLY :- (i) MCB SPN 32 Amps, 230 volts, 50Hz, rupturing capacity 10 KA C Curve = 6 Nos. The panel manufacturer should have following Govt. Approved Certificates: 1. Panel should be according to IEC-61439. CPRI Certification Degree of Protection IP-54 (IS/IEC : 61439 (Part-1), 2011 & IS/IEC : 61439 (Part-2) 2011) 2. Tempreature Rise (IS/IEC : 61439-1, 2011 & IS/IEC : 61439-2 2011) 3. CPRI Short Circuit IEC-61439-1 & 2 withstand strenght should be 70kArms for 1.0 Sec with intial peak of 154kApk 4. CPRI Certification IEC-61439-1 & 2 Rated current for short circuit not less than 6300 A with rated insulation voltage 660V 5. ISO 9001 CERTIFIED
Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Taking down of unsv LT Panel board with frame and fitting complete and Supply, installing, testing and commissioning factory made LT ( 415 Volts, 50 Hz , 3-phase, 4 wire supply ) CPRI approved, factory assembled Outdoor Feeder Pillar type, weather proof, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated Aluminium bus bars of 200 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, ingress protection class ( IP-54 ) and made of 3.15 mm thick CRCA mild steel sheet and mild steel, Angle iron frame work made out of 40 X 40 X 6 mm ), front and rear opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FR wire of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey shade 7035. embedded in ground with and including bocks of PCC 1:2:4 type B1 of block size 30x30x30 cm comprising of the following:-
The panel manufacturer should have following Govt. Approved Certificates: 1. Panel should be according to IEC-61439. CPRI Certification Degree of Protection IP-54 (IS/IEC : 61439 (Part-1), 2011 & IS/IEC : 61439 (Part-2) 2011) 2. Tempreature Rise (IS/IEC : 61439-1, 2011 & IS/IEC : 61439-2 2011) 3. CPRI Short Circuit IEC-61439-1 & 2 withstand strenght should be 70kArms for 1.0 Sec with intial peak of 154kApk 4. CPRI Certification IEC-61439-1 & 2 Rated current for short circuit not less than 6300 A with rated insulation voltage 660V 5. ISO 9001 CERTIFIED
Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Excavation, in trenches not exceeding 1.5 mtr wide and not exc 1.5 mtr in depth for laying cable in any type of soil and getting out complete all as specified & directed by Engineer-in-Charge.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick all as specified & directed by Engineer-in-Charge..
Removal of surplus excavated material to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
M & L Sand cushioning to under ground cable with dry sand locally available 8cm thick before laying the cable and 15 cm above the cable, stretching and testing of cable complete all as specified & directed by Engineer-in-Charge.
Taking out old unserviceable / serviceable class 'B' bricks from excavated trenches all as specied and directed by Engineer-In-Charge. Note:- Serviceable class 'B' bricks kept in safe custody for reuse at site and unserviceable bricks to be through in low lying area.
Supply and laying sub class ‘B’ bricks well burnt for cable protections laid flat with length equal to width of brick over cable perpendicular to length of cable complete all as specified and directed by Engr-in-Charge
Laying only serviceable sub class ‘B’ bricks as retrieved from Srl item No 09 complete all as specified and directed by Engr-in-Charge.
M&L for cable jointing kit for 11 KV (Earthed) grade for outdoor termination end joint kit, heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed by Engr-in-charge.
S&F for cable jointing kit for 11 KV (Earthed) grade for indoor termination end joint kit heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed by Engr-in-charge.
S&F for cable jointing kit for 11 KV (Earthed) grade for straight through, heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed by Engr-in-charge.
S&F for Heat Shrinkable 1.1 KV XLPE Straight Joints of following size including taking down complete all as specified and directed by Engr-in-charge and directed as follows :
25 sqmm to 50 sqmm size
70 sqmm to 150 sqmm size
185 sqmm to 300 sqmm size
M&L for Arranging fault locating machine to locate the fault in underground electric power cable of any length & any type of 11 KV/1.1 KV grade HT/ LT cables & pin point the fault, it also include testing of the cable after locating fault and cutting the cable at Fault to fix the joint including excavation and earth wotrk in any type of soil complete Note : Cable joint shall be measured and paid separately under respective of Sch 'A' (ii) If fault is not rectifed within 24 hours after receivng message , the contractor shall be charged penalty for Rs 500/- per Hours & the same has been deducred from his account during RAR
S&F in repairs of moulded case circuit breaker four pole 630 Amps 50 KA capacity 415V 50Hz with adjustable thermal and magnetic relay incl replacement of lugs & disconnecting and taking out the old unservicable MCCB from panel/DBs/ etc complete all as specified and directed by Engr-in-charge and directed. (Make of MCCB's Legrand/Havells/L&T/C&S) as per site requirement.
All as per item No 17 above but 400 amps 4 pole 36 KA Capacity 415V 50 Hz.
All as per item No 17 above but 250 amps 4 pole 36 KA Capacity 415V 50 Hz.
All as per item No 17 above but 200 amps 4 pole 36 KA Capacity 415V 50 Hz.
All as per item No 17 above but 160 amps 3 pole 36 KA Capacity 415V 50 Hz.
All as per item No 17 above but 100 amps 3 pole 16 KA Capacity 415V 50 Hz.
S&F in repairs of old unserviceabel digital voltmeter of range 0-500 volts suitable for LT Panel complete all as specified and directed by Engineer-In-Charge.
S&F in repairs of old unserviceabel digital Ampere meter of range 0-630 Amps suitable forLT Panel complete all as specified and directed by Engineer-In-Charge.
S&F in repairs of old unserviceable indication lamp( R,Y,B) for LT Panel complete all as specified and directed by Engineer-In-Charge.
S&F in repairs of LED Street light fitting 45 Watt Highly efficient made of pressure die cast aluminium housing with lens & toughened glass in replacement of old unservicable conventional security light fitting including fixing material ie MS clamp, Nut and bolt,anchor fastner washer etc complete all as directed .
S&F in repairs of LED Street light fitting 60 Watt Highly efficient made of pressure die cast aluminium housing with lens & toughened glass in replacement of old unservicable conventional security light fitting including fixing material ie MS clamp, Nut and bolt,anchor fastner washer etc complete all as directed .
S&F in repairs of Building security light fitting 30 watt to be fitted at the pheripheral surfaces of the building including fixing with Ms clamp,nut,bolts complete all as specified and as directed.Make :Cat Part : LSTS-30-CDL-M of CG or equivalent in Havells/Halonix).
S&F in repairs of Cable, single core 1.5 Sqmm size,FRLS type two runs(for phase and neutral) PVC insulated unsheathed multi stranded copper conductor cables drawn in PVC Conduit complete all as specified and directed.Make : Havells/Polycab/ Finolex. Note -( two runs of 1.5 Sq mm single core copper conductor shall be measured as one unit length)
S&F thermoplastic cable junction box with metric knock out for cable entry of size 200x160x98mm with 4 Nos of 200A aluminium busbar mounted on insulators, terminal and provision of din rail for fixing of MCB 10A capacity including fixing with clamp 30x5mm iron flate, nuts, bolts and washer complete including providing of steel conduit of dia 32mm bore of length 1.60 mtr including earth work for taking out of cable,old unsv junction box and fixing complete all as specified and directed.
S&F in repairs GI braket for fixing of bldg security light fitting with GI pipe 32/40 mm dia atleast 1.5 mtr long to be fixed in wall/pole and it has to be bend in 45 degree angle to install the bldg security light fitting/street light fittings including necessary cutting, welding and MS fastner, clamp with strip 38mm wide upto 6mm thick (Min) to the light and painting the bracket by good quality paint as directed by Engr-in-Charge.
Note :- The contract sum shall be after deducting the amount of credit shown in Sch of Credit of this tender
Vijeta Solutions (BID ID -3074137)
M P TYAGI ENGINEERS AND CONTRACTORS (BID ID -3072682)
PD SHARMA AND SONS (BID ID -3078818)
R C Sharma and Co (BID ID -3073161)
Rahul Enterprises (BID ID -3072505)
MOHIT ENTERPRISES (BID ID -3074593)
M/S Malik Construction Corporation (BID ID -3080038)
H.B. Traders (BID ID -3078810)
SHREE RAM BUILD TECH (BID ID -3074341)
V.K. Enterprises (BID ID -3074546)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .