| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.9 LAccepted-AOC 4 BY 8 BLOCK H NEAR VIJAY CHOWK EAST DELHI DELHI 110051 | EAST DELHI | DELHI | 110051 | L1 | Accepted-AOC M/s Aggarwal Construction Co is L1 | |
| 2 | L2₹32.4 L+₹5.3 L (19.7%)Rejected-Finance 1227 MODEL TOWN MODEL TOWN BATHINDA BATHINDA PUNJAB 151001 | BATHINDA | PUNJAB | 151001 | L2 | Rejected-Finance Quoted other than lowest rate | |
| 3 | L3₹33.7 L+₹6.6 L (24.3%)Rejected-Finance BLDG NO XI 74 NEAR VALLARAM KULLANGARA TEMPLE KUNHIMANGALAM KOVVAPPURAM PO KANNUR DIST KERALA 670309 | KANNUR | KERALA | 670309 | L3 | Rejected-Finance Quoted other than lowest rate | |
| 4 | L4₹38.3 L+₹11.2 L (41.2%)Rejected-Finance KOHLI NO 17509 GALI KHADDAR BHANDAR WALI BHI WALA ROAD BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L4 | Rejected-Finance Quoted other than lowest rate | |
| 5 | L5₹39.6 L+₹12.5 L (46.1%)Rejected-Finance SIDDHARTH ENCLAVE NEAR JINDAL FACTORY RAMNAGAR ROORKEE 247667 | HARIDWAR | UTTARAKHAND | 247667 | L5 | Rejected-Finance Quoted other than lowest rate |
| Sl No | Description | Qty | Unit | M/s VISHAL ELECTRIC STORE L2 | M/s BHUPINDRA ENGINEERING WORKS L4 | RS ENTERPRISES L3 | ANANT ENTERPRISES L5 | M/S Aggarwal construction co. L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully aluminium point wiring (light point, fan point, socket outlet or power point), complete with removal of all associated fittings such as hylam sheet, switches, ceiling rose, pendant holder, socket outlets, regulators, etc., including concealed conduit where ever required and sunken boxes wherever provided. The work shall also include making good all disturbed wall and floor surfaces to match the existing finish, complete in all respects, as specified and directed by the Engineer-in-Charge. | 1,655 | Per Point | 10 ₹16,550 Lowest | 15 ₹24,825 | 10 ₹16,550 Lowest | 40 ₹66,200 | 10 ₹16,550 Lowest |
| 2.00 | Material and Labour for concealed modular type point wiring in existing PVC conduit, complete with 1.5 sqmm nominal cross-sectional area FRLSH PVC insulated, unsheathed, multi-strand copper conductor cable, 1100 V grade (ISI marked), drawn through the existing rigid PVC conduit. The work shall include providing and fixing a modular metal flush-type sunken box of suitable size with a new white modular cover plate, frame, mounting switches, socket outlet, and fan regulator, as required, for one light point or one fan point controlled by a single switch. The cover plate shall be fixed with brass screws and cup washers. The work shall also include providing one continuous 1.5 sqmm FRLSH PVC insulated multi-strand copper conductor wire as the earth continuity conductor, properly connected to the earth dolly, complete in all respects, as specified and directed by the Engineer-in-Charge. | 800 | Per Point | 450 ₹3,60,000 | 500 ₹4,00,000 | 500 ₹4,00,000 | 550 ₹4,40,000 | 330 ₹2,64,000 Lowest |
| 3.00 | All as per Item No. 02 hereinbefore, but for one 5-pin, 5/6 Amp modular socket outlet mounted on the same modular board, complete with all necessary accessories, connections, and fittings, complete in all respects, as specified and directed by the Engineer-in-Charge. | 160 | Per Point | 250 ₹40,000 | 250 ₹40,000 | 500 ₹80,000 | 220 ₹35,200 | 130 ₹20,800 Lowest |
| 4.00 | All as per Item No. 02 hereinbefore, but for one 5-pin, 5/6 Amp modular socket outlet mounted on an independent modular board, located not below the switchboard, complete with modular metal flush-type box, white modular cover plate, frame, socket outlet, wiring, connections, and all necessary accessories, complete in all respects, as specified and directed by the Engineer-in-Charge. | 180 | Per Point | 450 ₹81,000 | 500 ₹90,000 | 500 ₹90,000 | 550 ₹99,000 | 330 ₹59,400 Lowest |
| 5.00 | All as per Item No. 02 hereinbefore, but for one 6-pin, 15/16 Amp, 2-in-1 multipurpose modular socket outlet mounted on an independent modular board, complete with 2.5 sqmm nominal cross-sectional area FRLSH PVC insulated, unsheathed, multi-strand copper conductor cable drawn through the existing PVC conduit. The work shall also include providing one continuous 2.5 sqmm single-core, multi-strand FRLSH insulated copper conductor as the earth continuity conductor, properly connected to the common earth, along with all necessary modular accessories, connections, fittings, and fixing arrangements, complete in all respects, as specified and directed by the Engineer-in-Charge. | 150 | Per Point | 750 ₹1,12,500 | 650 ₹97,500 | 600 ₹90,000 | 850 ₹1,27,500 | 330 ₹49,500 Lowest |
| 6.00 | All as per Item No. 02 hereinbefore, but for one light point controlled by two 2-way modular switches, complete with all necessary wiring, interconnections, modular accessories, fittings, and fixing arrangements, complete in all respects, as specified and directed by the Engineer-in-Charge. | 40 | Per Point | 480 ₹19,200 | 500 ₹20,000 | 600 ₹24,000 | 600 ₹24,000 | 330 ₹13,200 Lowest |
| 7.00 | All as per Item No. 02 hereinbefore, but for one bell/buzzer point, complete with all necessary modular accessories, wiring, connections, fittings, and fixing arrangements, complete in all respects, as specified and directed by the Engineer-in-Charge. | 30 | Per Point | 480 ₹14,400 | 500 ₹15,000 | 600 ₹18,000 | 500 ₹15,000 | 330 ₹9,900 Lowest |
| 8.00 | Material and Labour for concealed modular type point wiring, complete with 1.5 sqmm nominal cross-sectional area FRLSH PVC insulated, unsheathed, multi-strand copper conductor cable, 1100 V grade (ISI marked), drawn through and including 20/25 mm dia rigid PVC conduit. The work shall include providing and fixing a modular metal flush-type sunken box of suitable size with a new white modular cover plate, frame, mounting switch, socket outlet, and fan regulator, as required, for one light point or one fan point controlled by a single switch. The cover plate shall be fixed with brass screws and cup washers. The work shall also include providing one continuous 1.5 sqmm FRLSH PVC insulated multi-strand copper conductor wire as the earth continuity conductor, properly drawn through the conduit and connected to the earth dolly. The item shall be complete in all respects, including all materials, labour, accessories, and fittings, as specified and directed by the Engineer-in-Charge. | 200 | Per Point | 450 ₹90,000 | 500 ₹1,00,000 | 500 ₹1,00,000 | 570 ₹1,14,000 | 350 ₹70,000 Lowest |
| 9.00 | All as per Item No. 08 hereinbefore, but for one 5-pin, 5/6 Amp modular socket outlet mounted on the same modular board, complete with all necessary modular accessories, wiring, connections, fittings, and fixing arrangements, complete in all respects, as specified and directed by the Engineer-in-Charge. | 25 | Per Point | 250 ₹6,250 | 250 ₹6,250 | 500 ₹12,500 | 300 ₹7,500 | 150 ₹3,750 Lowest |
| 10.00 | All as per Item No. 08 hereinbefore, but for one 5-pin, 5/6 Amp modular socket outlet mounted on an independent modular board, located not below the switchboard, complete with modular metal flush-type box, white modular cover plate, frame, socket outlet, wiring, connections, and all necessary accessories, complete in all respects, as specified and directed by the Engineer-in-Charge. | 30 | Per Point | 450 ₹13,500 | 500 ₹15,000 | 500 ₹15,000 | 570 ₹17,100 | 350 ₹10,500 Lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
31 Aug 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Jitender Singh IDSE
GE (N) Bathinda
REPAIR/ MAINT OF INTERNAL ELECTRIC POINT WIRING AND SUB MAIN WIRING IN MD ACCN UNDER GE (N) BATHINDA AT BATHINDA MIL STN
2026_MES_773775_2
8941/NIT-12/26-27/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Bathinda
Class D Category b(i)
8 documents required · 8 mandatory
₹500
GE (North) Bathinda
₹90,000
Yes
6 Nov 2026
8 Aug 2026
2 Sept 2026
8 Aug 2026
31 Aug 2026
17 Aug 2026
8 Aug 2026 - 14 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down carefully aluminium point wiring (light point, fan point, socket outlet or power point), complete with removal of all associated fittings such as hylam sheet, switches, ceiling rose, pendant holder, socket outlets, regulators, etc., including concealed conduit where ever required and sunken boxes wherever provided. The work shall also include making good all disturbed wall and floor surfaces to match the existing finish, complete in all respects, as specified and directed by the Engineer-in-Charge. | 1,655 | Per Point | - | - |
| 2 | Material and Labour for concealed modular type point wiring in existing PVC conduit, complete with 1.5 sqmm nominal cross-sectional area FRLSH PVC insulated, unsheathed, multi-strand copper conductor cable, 1100 V grade (ISI marked), drawn through the existing rigid PVC conduit. The work shall include providing and fixing a modular metal flush-type sunken box of suitable size with a new white modular cover plate, frame, mounting switches, socket outlet, and fan regulator, as required, for one light point or one fan point controlled by a single switch. The cover plate shall be fixed with brass screws and cup washers. The work shall also include providing one continuous 1.5 sqmm FRLSH PVC insulated multi-strand copper conductor wire as the earth continuity conductor, properly connected to the earth dolly, complete in all respects, as specified and directed by the Engineer-in-Charge. | 800 | Per Point | - | - |
| 3 | All as per Item No. 02 hereinbefore, but for one 5-pin, 5/6 Amp modular socket outlet mounted on the same modular board, complete with all necessary accessories, connections, and fittings, complete in all respects, as specified and directed by the Engineer-in-Charge. | 160 | Per Point | - | - |
| 4 | All as per Item No. 02 hereinbefore, but for one 5-pin, 5/6 Amp modular socket outlet mounted on an independent modular board, located not below the switchboard, complete with modular metal flush-type box, white modular cover plate, frame, socket outlet, wiring, connections, and all necessary accessories, complete in all respects, as specified and directed by the Engineer-in-Charge. | 180 | Per Point | - | - |
| 5 | All as per Item No. 02 hereinbefore, but for one 6-pin, 15/16 Amp, 2-in-1 multipurpose modular socket outlet mounted on an independent modular board, complete with 2.5 sqmm nominal cross-sectional area FRLSH PVC insulated, unsheathed, multi-strand copper conductor cable drawn through the existing PVC conduit. The work shall also include providing one continuous 2.5 sqmm single-core, multi-strand FRLSH insulated copper conductor as the earth continuity conductor, properly connected to the common earth, along with all necessary modular accessories, connections, fittings, and fixing arrangements, complete in all respects, as specified and directed by the Engineer-in-Charge. | 150 | Per Point | - | - |
| 6 | All as per Item No. 02 hereinbefore, but for one light point controlled by two 2-way modular switches, complete with all necessary wiring, interconnections, modular accessories, fittings, and fixing arrangements, complete in all respects, as specified and directed by the Engineer-in-Charge. | 40 | Per Point | - | - |
| 7 | All as per Item No. 02 hereinbefore, but for one bell/buzzer point, complete with all necessary modular accessories, wiring, connections, fittings, and fixing arrangements, complete in all respects, as specified and directed by the Engineer-in-Charge. | 30 | Per Point | - | - |
| 8 | Material and Labour for concealed modular type point wiring, complete with 1.5 sqmm nominal cross-sectional area FRLSH PVC insulated, unsheathed, multi-strand copper conductor cable, 1100 V grade (ISI marked), drawn through and including 20/25 mm dia rigid PVC conduit. The work shall include providing and fixing a modular metal flush-type sunken box of suitable size with a new white modular cover plate, frame, mounting switch, socket outlet, and fan regulator, as required, for one light point or one fan point controlled by a single switch. The cover plate shall be fixed with brass screws and cup washers. The work shall also include providing one continuous 1.5 sqmm FRLSH PVC insulated multi-strand copper conductor wire as the earth continuity conductor, properly drawn through the conduit and connected to the earth dolly. The item shall be complete in all respects, including all materials, labour, accessories, and fittings, as specified and directed by the Engineer-in-Charge. | 200 | Per Point | - | - |
| 9 | All as per Item No. 08 hereinbefore, but for one 5-pin, 5/6 Amp modular socket outlet mounted on the same modular board, complete with all necessary modular accessories, wiring, connections, fittings, and fixing arrangements, complete in all respects, as specified and directed by the Engineer-in-Charge. | 25 | Per Point | - | - |
| 10 | All as per Item No. 08 hereinbefore, but for one 5-pin, 5/6 Amp modular socket outlet mounted on an independent modular board, located not below the switchboard, complete with modular metal flush-type box, white modular cover plate, frame, socket outlet, wiring, connections, and all necessary accessories, complete in all respects, as specified and directed by the Engineer-in-Charge. | 30 | Per Point | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.98 MB
tenderdocuments12.pdf
Tender Documents • 0.84 MB
BOQ_877756.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .