Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹4.3 L+₹26,861 (6.63%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹4.4 L+₹31,206 (7.70%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹4.2 L
EMD Value
₹8,400
Closing Date
30 Sept 2019, 2:00 pmClosed
Executive Engineer University works department
Executive Engineer University works department
Exension or additional accommodation for the deptt of physiotherapy in Health centre Electric work
2019_UDJK_81981_1
enit 410 dated 12-9-19
Open Tender
Electrical Works
Item Rate
150 days
University of Jammu
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Executive Engineer University works department
₹8,400
24 Aug 2021
18 Sept 2019
3 Oct 2019
18 Sept 2019
30 Sept 2019
18 Sept 2019
Amount
Wiring for light point/fan point/ceiling fan point/exhaust fan point/call bell point with 1.5 Sq. mm FRLS PVC insulated, copper conductor cable in surface/recessed medium class PVC conduit, with piano type switch, phenolic, laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq mm. FRLS PVC insulated copper conductor single core cable etc. as required. (Wire Make ISI Marked Havells/Anchor/HPL/Shalimar/KEI/Polycab)(Conduit Make - ISI Marked Anchor/High Power /Finlox/National Gold/Shalimar /Ravindra) Group ‘C’
Wiring for circuit/sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.(Wire Make ISI Marked Havells/ Bonton/ Anchor/Grandley/ L&T/HPL/ Shalimar/ KEI/polycab) 2 x 1.5 + 1 x 1.5 Sqmm
--------------do-------------- 2 x 2.5 + 1 x 2.5 Sqmm
-------------do-------------- 2 x 6 + 1 x 6 Sqmm
-------------do-------------- 4 x 4 + 2 x 4 Sqmm
-------------do---------------- 4 x 6 + 2 x 6 Sqmm
Supplying and fixing of following sizes of medium class PVC conduit along with the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required- ISI Marked Anchor/High Power /Finlox/National Gold/Shalimar /Ravindra) 25 mm dia
Supplying and fixing 5 amp to 32 amps rating, 240/415 volts, 10 KA C curve miniature circuit breaker of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make Havells /Legrand /Anchor/ C&S/L&T /Siemen/ IA/HPL/Standard/Wipro) Single pole
Earthing with Copper earth plate 600mm x 600mm x 3mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/coke and salt as required.
Providing and fixing 4mm dia copper wire on surface or in recess for loop earthing as required.
Supply and fixing of metal Box of following size on the surface/recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 100mm x 100mm x 60mm deep
---------------do--------------- 200mm x 125mm x 60mm deep
--------------do---------------- 200mm x 150mm x 60mm deep
Supply & fixing 15/16 amp piano type switch on the existing switch box or cover including connection as required. (Make: Anchor/Havells /SSK/HPL)
Supply & fixing 6 pin 15/16 amp socket outlet on the existing switch box or cover including connection as required (Make: Havells/ HPL/ Anchor/SSK)
Supply & fixing 5/6 amp piano type switch on the existing switch box or cover including connection as required (Make :Havells/ HPL / Anchor /SSK )
Supply & fixing 3 pin 5/6 amp socket outlet on the existing switch box or cover including connection as required(Make: Havells/ HPL / Anchor /SSK)
Supplying and fixing following ways and poles, plain/horizontal sheet steel MCB Distribution Board on surface/in recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections including powder painted earthing etc. as required (But without MCB/RCCB/Isolators) (Indokapp, Havells/Anchor /I.A /Legrand/Standard) 8 way (4+24), 415 volts, three phase and neutral double door
Supply & fixing two module stepped type electronic fan regulator on the existing modular plate/switch box including connections but excluding modular plate etc. as required. (Make Havells/ HPL / Anchor /SSK/ C&S/Great White)
Supplying and fixing brass batten/Angle holder including connection etc. as required. (Make Havells/ HPL / Anchor /SSK/ C&S/Great White)
Supplying and fixing 3 pin, 5 A Ceiling Rose on the existing junction box/wooden block including connection etc. as required. (Make Havells/ HPL / Anchor /SSK/ C&S/Great White)
Providing and fixing following rating and breaking capacity MCCB with Thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Make Siemens/Schreinder/ L&T/ Hager /Havells/IA/HPL/ Standard/Crompton) 100 AMP 16KA TP
----------------do------------------ 200 Amp 36 KA FP
S/F piano type Telephone socket outlet on the existing Switch Box or cover including connection as required. required (Make Havells/HPL/Anchor/SSK /C&S)
Supplying & drawing 2 pair (0.50)sqmm FR PVC insulated annealed copper conductor un armoured telephone cables in the existing surface/recessed steel or PVC Conduit as required (Make ISI Marked Havells/ECKO/Anchor/ Grandley /L&T /Helicab/KEI/HPL)
Supply and drawing UTP 4 Pair Cat 6 LAN Cable in the existing surface/recessed steel/PVC conduit as required (Make Legrand /Havells / Anchor/D Link /HPL/L&T) 1 run of cable
Supplying and fixing following rating of Isolator/SPN in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Indokapp, Havells, anchor) 63 Amp 415 volts Four Pole Isolator
------------------do------------------ 32-63 Amp SPN
Supply & installation of CAT 6 2 module toll less information outlets complying fully or exceeding with category 6 connecting hardware specifications for all pair combinations upto 250 MHz. Outlets shall use lead frame technology, non PCB pyramid type complete as required.(Make Legrand/Delton/Systemax /Penuit/ Havells/HPL/Anchor)
Supply and installation of Singlex Face Plates along with clearly printed labels and holders complete as required(Make Legrand /Havells / Anchor/D Link /HPL/L&T/G.E)
S/F of 20mm dia G.I pipe for flood light bracket including bending to shape, (40x3)mm flat iron clamp and wiring with 1.5 sqmm PVC insulated wire complete wire complete as reqd.
Supply/Installation testing and commissioning of following type of surface mounted/recessed mounted decorative Indoor Linear with extruded Al. heat sink, environmental friendly energy efficient LED tube Light decorative energy efficient square moulded LED energy saving type. Make (Halonix/ Havells/ Syska/Bajaj/Eon/Greatwhite/ Philips/ HPL/Crompt-on/Wipro) 4 feet 18 to 22 watt, 230 volts LED batten type tube light fitting complete.
-----do---- 12 To 18 Watt LED recessed mounting down, 6500 K, 240 Volts as per cat: GARNET Slim Panel Light square/ Panel Light Round.
Supply/installation of the following type of outdoor decorative faced light, bollard light, flood light and Street lights luminaries complete with all accessories connection testing and commissioning as required including making the PCC foundation with nut and bolts where required as per following. Make (Bajaj/Legrand /Surya /Havells/Hager/ C&S/ HPL/wipro) 45 watt to 60 watt, 230 volts IP65/66 LED.
Design, manufacture, testing at works & supply, installation, testing & commissioning cubicle panel floor mounted (on base frame) totally enclosed and extensible type . The general construction shall comprise to IS 8623-93. The design shall include all provisions for safety of operating and maintenance personal. IP 42 for indoor and IP54 for outdoor, shall be compartmentalized type having space and arrangements for I/C. cable/bus ducting/incoming switch gears, bus couplers, insulated and properly supported compartmentalized switch gear, outgoing compartmentalized switch gear, bus bar support and terminations, interconnection between bus bars & switch gear with auxiliary bus bars/insulated conductors/strips etc. The panel shall be fabricated out of CRCA not less than 2.00 mm thick for the load bearing members and 1.6mm for doors of L.T Panels. The frame work may be Agle Iron/Channel/Bolted type construction should be arrangement for I/C/O/G. Cable termination with 2 Each. 20x5mm cu. Strip fixed all around the panel connected to 2 Each. earth bars cu-strips connected to incoming earth conductor. (Make Electric Field/ Bharti Engineers/Gupta & Friends/ Semon/ Jai maa/U.S.Electrical works) MAIN OUTDOOR /BUILDING CONTROL PANEL a. INCOMING Space for 1 No. 100 to 630 Amp TPN Al. Bus bar of equal cross section for Main Power connection to Main MCCB. Space for 1 No. 100 to 630 Amp 4 pole MCCB of 35 KA INDICATING PANEL The indicating panel of the incomer shall be provided with the following: i. Ammeter of required range with ASS, CT's. ii.Voltmeter of required range with VSS. c. OUTGOING Space for 1 No. 100 to 630 Amp TPN Al. Bus bar of equal cross section for power load/light load. Dimension of the Panel = 4’x3’x1’6”
Supply, testing and commissioning of PVC sheathed Aluminum conductor 1100 volts graded PVC AA Armoured/unarmoured XLPE Cable including end termination, crimping, cost of thimbles, nuts bolts, glands, connection, testing and commissioning complete job. (Make Havells /CCI/ Grandley /Finlox /Plaza / General/Polycab/Gloster) 2 core 16 sq mm armoured cable
------------------do--------------------- 3 ½ core 95 sq mm armoured cable
Supply, installation, testing, commissioning of 1200 mm sweep ceiling fans complete with blades (Make: Havells (Model: AEROKING hi -Speeed) Crompton (Model: Avancer prime Anti Dust)/ Anchor(Model: XL Premium Anti DUST)
Supply, installation, testing, commissioning of heavy duty 300 mm sweep Exhaust fan (Make Havells (Ventil Air DS), Usha (Fresh Air Deluxe), Orient (Freshee Air Deluxe), Anchor(flux Air 12”)
P/F following rating 230 volts energy saver LED Lamps. (MakePhilip /Havells/Bajaj/ Surya/ /Crompton/ Wipro) 8 to12 watt LED lamp
Providing and fixing of ding dong wall bell including connections as reqd. (Anchor/SSK/Klick)
Supply and fixing of following rating onload I-O-II Four pole with advanced neutral on load change over switch confirms to IS 13947 (Part-3) IEC:609473) (Make Legrand/ I.A/Havells /Siemen/HPL) 100 Amp
Harjeet Singh Electrical Contractor
S D SALES AND ENGENRING CONCEPTS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .