Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.5 LAccepted-AOC | L1 | Accepted-AOC Reasonable rate | |
| 2 | L2₹24.5 L+₹1.3 L (5.74%)Rejected-Finance | L2 | Rejected-Finance Quoted amount higher than L1 | |
| 3 | L3₹24.7 L+₹1.5 L (6.47%)Rejected-Finance | L3 | Rejected-Finance Quoted amount higher than L1 | |
| 4 | L4₹24.8 L+₹1.6 L (7.03%)Rejected-Finance | L4 | Rejected-Finance Quoted amount higher than L1 | |
| 5 | Rejected-Technical | - | Rejected-Technical Not fulfilled the NIT criteria |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
20 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col N K Chaudhary
HQ 137 WKS ENGR PIN 914137 CO 99 APO
REPAIR AND MAINT OF TRANSFORMER AND HT DISTRIBUTION SYSTEM AT MASIMPUR MIL STN UNDER GE SILCHAR
2023_MES_576559_1
8750/E8
Open Tender
Civil Works
Item Rate
180 days
Silchar
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE Silchar
₹44,000
Yes
30 Mar 2023
21 Jan 2023
27 Feb 2023
21 Jan 2023
20 Feb 2023
6 Feb 2023
Amount
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre depth for foundation of poles, laying of cables etc not exceeding 10 sqm on plan area and getting out in soft / loose soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 metre wide and exceeding 1.50 metre but not exceeding 3.00 metre depth for foundation of poles, laying of cables etc not exceeding 10 sqm on plan area and getting out in soft / loose soil complete all as specified and as directed.
Returning, filling in, of soil including spreading leveling, watering and well ramming in layers not exceeding 25 cm.thick complete all as specified and as directed .
Removing excavated material to a distance n.exc 50.00 metre and depositing/spreading where directed at a level n. exc 1.50 metre above the starting point complete all as specified and as directed .
Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of under ground cable including spreading and punning down complete all as specified and as directed. Note:- Punned down thickness shall be measured.
Materials and labour for brick protection cover to underground cables with sub class ‘B’ over burnt brick of size 23 X 11.5 X 7.5 cm, (locally available), laid dry and flat abutting each other with gaps not exceeding 10mm complete all as specified and as directed.
Dismantling old u/s RCC/Steel poles/struts of any size incl breaking up PCC foundation complete all as specified and directed by Engr-in-Charge.
Supply and fixing of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified, type 410 SP-55 (Over all length 11 metres long) conforming to IS-2713. Pole shall be painted with one coat of red oxide primer throughout internally and externally up to 1.9 mtr length from bottom and the remaining external portion shall be painted with two coats of aluminium paint over a coat of red oxide primer and numbering the pole with white paint alfa numeric letters on black patch complete all as specified and directed. (Note: Excavation, earth work and PCC shall be mersured and paid separatly)
Dismantling of corroded/ rusted/ defective cross-arms of MS. Channel or angle of any sections complete all as specified and directed
Material and labour for cross arm bracing, support, clamps and back plate fabrication from structural steel section including nuts., bolts, washers welding bending cold or hot drilling holes in any shape or size as indicated or directed by Engr-in-Charge and incl two coats of aluminium paint over a coat of zinc chrome primer complete all as specified and directed.
Dismantling of old unserviceable insulator, any type / size complete all as specified and directed.
Supply and fixing Pin type insulator, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade complete all as specified and directed by Engr-in-Charge
Supply and fixing Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green, Single disc assembly incl nuts and bolts of working pressure 11000 volts grade complete all as specified and directed by Engr-in-Charge
Dismantling of old unserviceable damaged stay assembly embedded in concrete including demolition of PCC complete all as specified and directed.
Supply and fixing stay assembly using 16 mm diameter of stay rod complete with accessories as shown in electrical plate No. 1 of SSR part -I all as specified and directed. Note: loop type insulator, stay strand with stay clamps, excavation and concrete shall be measured and paid separately
Supply and fixing loop type insulator, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, arge size, with overall dimensions 90mmx140mm, clearance of hole 25.5mm for 11000 volts grade complete all as specified and directed by Engr-in-Charge.
Materials and labour for galvanized stay strand of size 7/3.15mm incl securing with LT pole clamp and stay clamp complete all as specified and directed by Engr-in-Charge.
Dismantling old unserviceble air break gang operated switches vertical/horizontal mounted incl insulators and operating mechanism complete all as specified and as directed .
Supply and fixing triple pole mechanically operated air break isolator (GOD), vertical mounting, rotating type, mounted on insulators and steel frame with operating mechanism worked from ground level complete in all respect such as gun metal moving contacts and spring loaded gun metal fixed jaws, knife copper jumper strip etc, suitable for 11000 Volts grade, with 9 insulators of rating upto 200 Amps complete all as specified and as directed.
Taking down unserviceable /damaged XLPE HT cable of any size and any type from trenches /poles/wall etc after necessary electrical disconnectin complete all as specified and directed.
Supplying, Laying connecting & testing XLPE insulated, PVC sheathed, armoured HT electric power UG cable (heavy duty with stranded aluminum conductor) of size 95 Sqmm, 3 core, 11000 Volts(Earthed) grade, with FRLS PVC outer sheathed, conforming to IS-7098 (Part-II) laid through duct/ pipe / in trench etc. with cable glands and including suitable size of aluminium lugs complete all as specified and as directed. Note : Earth work, brick protection and sand cushioning and GI Pipe Shall be measured and paid separately under respective item.
Supply and laying un-reinforced precast concrete cable cover, class HV type 1, flat size 300mm x 180mm x 40mm laid flat and dry in trenches over the cable complete all as specified and directed.
S&F in replacement for cable jointing kit for 11KV (earthed) grade cable for straight through heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and as directed.
Supply and fixing end termination joint kit for HT cable, heat shrinkable, indoor type with jointing material & accessories suitable for voltage 11 kV (Earthed), 3 core 50 sqmm to 95 sqmm complete all as directed by Engr-in-charge.
Supply and fixing end termination joint kit for HT cable, heat shrinkable, outdoor type with jointing material & accessories suitable for voltage 11 kV (Earthed), 3 core 50 sqmm to 95 sqmm complete all as directed by Engr-in-charge.
Repair to HT 11 KV 4 pole structure of 11 metre height steel/RCC poles including replacement of all perished ACSR conductor (weasel) of horizontal bus bar and down conductor for 4 Nos/2 Nos GOD system on structure, jumpering and binding with aluminium conductor to the post insulators/pin insulators and providing PVC sleeve insulation Grade II suitable for 11 KV to the down conductor with colour code R, Y &B, replacing all rusted nuts and bolts complete all as specified and directed.
Repair to HT 11 KV 2 pole / 3 pole structure of 11 metre height steel/RCC poles including replacement of all perished ACSR conductor (weasel) of horizontal bus bar and down conductor for 4 Nos/2 Nos GOD system on structure, jumpering and binding with aluminium conductor to the post insulators/pin insulators and providing PVC sleeve insulation Grade II suitable for 11 KV to the down conductor with colour code R, Y &B, replacing all rusted nuts and bolts complete all as specified and directed.
Supply, install, testing and commissioning of lightening arrestor non-linear resistor type complete with all fittings, line discharge class - 3, nominal discharge current 10 KA (Peak), 12 KV rated system voltage peak value high current impulse of 4/10 micro sec, wave shape 100 KA (peak) assy suitable for 11 KV, long duration class-11 with insulation level 28/75 KV & insulated on hot dip galvanised steel structure incl all clamp, nuts, bolts & washers & connecting to earth complete on pole structure all as per IS-3070 Part-III (1993) and IEC 1994 including dismantling of existing unsv lightening arrestor complete all as specified and directed.
Supply and Laying 80mm bore GI tubing light grade with all fitting for passing of cable under road, on wall or on pole with and incl clams, nuts, bolts etc incl taking down old unserviceable GI tubing of any size incl cutting, chases to wall/ floor and making good surface complete all as directed by Engr-in-charge.
Disconnecting, taking down distribution transformer outdoor type 11 kV /415 volts having capacity upto 500 kVA, transportation to the workshop for repairs including opening of transformers cover, draining of oil, de-tanking of core and coil assembly, cleaning, washing of dust and dirt from all parts including core, tank and cooling tubes radiators etc., joint inspection for estimate, replacement of defective parts, assembly, stage inspection, re-tanking, oil filtration/ dehydration, filling of dehydrated oil and fresh oil and testing the repaired transformers for all the routine tests as per IS 2026 (Part 1): 2011 with latest amendments and refixing at its original position or position as indicated and connecting HT/LT cable properly including testing before and after installation complete all as specified and directed by Engr-in-charge. Note: - (a) Transformer oil shall be drained out by the contractor in suitable capacity mild steel drums to be arranged by the contractor. The said drained out transformer oil shall be refilled in the transformer duly dehydrated after repair and the cost thereof shall be included in unit rate quoted against the respective item of this schedule. Dehydration of oil shall be measured and paid separetely. (b) Rewinding of both HT & LT coil shall be measured and paid for separately under respective item of this schedule. (c) Transportation charges for transportation of transformer from site to workshop and after repair, workshop to site shall be borne by the contractor and cost thereof shall be deemed to be included in the unit rate quoted for this item. (e) The said transformer shall be repaired in reputed workshop as approved by the GE. (f) Testing of transformer after repair shall be carried out as per IS 2026 (Part 1): 2011 and the cost of testing shall be deemed to be included in unit rate quoted against this item. (g) The IR value of the dried winding before inserting the core in the shell shall be measured and recorded.
Shifting of transformer carefully from the existing 2/4 pole structure/plinth/storeyard to another location under GE Silchar including transportation and connecting/disconnecting from HT/LT side and reconnecting the same and testing complete all as specified and directed. Note: Required tools and plants, labour and transportation charges for shifting shall be deemed to be included in quoted rate.
Supply only of porcelain HT bushing vitreous, brown colour, 11 KV grade along with a set of oil seals & copper alloy stud, nuts, washers etc. including dismantling existing HT bushing with copper alloy rod and disconnection of electrical connection, of suitable size for primary side (HT side ) of outdoor type 11 KV for 63 kVA upto and including 500 kVA distribution transformer of any make complete all as specified and directed by Engr-in-charge.
Supply only HT brass stud with brass nuts, bolts and washers suitable for outdoor type transformer upto 500 KVA capacity complete all as specified and directed.
Supply only of porcelain LT bushing vitreous, brown colour, 440 V grade along with a set of oil seals & copper alloy stud, nuts, washers etc. including dismantling existing LT bushing with copper alloy rod and disconnection of electrical connection, of suitable size for Secondary side (LT side ) of outdoor type 440V for 63 kVA upto and including 500 kVA distribution transformer of any make complete all as specified and directed by Engr-in-charge.
Supply only LT brass stud with brass nuts, bolts and washers suitable for outdoor type transformer upto 500 KVA capacity complete all as specified and directed.
Material & Labour for rewinding of unsv burnt out copper winding wire for HT side of Transformer of capacity upto 500 KVA with copper conductor super enamelled/DPC impregnated paper insulated as per existing gauge and turns with necessary insulating materials, varnishing, heating backing complete all as specified and directed.
Material & Labour for rewinding of unsv burnt out copper winding wire for LT side of Transformer of capacity upto 500 KVA with copper conductor super enamelled/DPC impregnated paper insulated as per existing gauge and turns with necessary insulating materials, varnishing, heating backing complete all as specified and directed.
Supply and fixing drain plugs of suitable size for existing transformer including taking down of existing unserviceable drain plug complete all as specified and directed.
Supply only new transformer oil of dielectric strength not less than 50 KV and conforming to IS-335 of 1993 for filling/ topping up oil of transformer up to desired level complete all as specified and directed.
Dehydration and filtration of existing transformer/Servo Stablizer oil of transformer at different location with filtration machine and heating system to get the minimum di-electric strength of oil 50 KV at 2.5mm gap minimum without disturbing the power supply system and refilling/ topping up /replacement of unserviceable transformer oil conforming IS-335-1993 complete all as specified and as directed by Engr-in-charge. Note: (a) Transformer oil required extra for filling/topping up shall be measured and paid separately under the relevant items of this schedule (b) cost of oil testing shall be deemed to be included in the unit rate quoted for this item and T&P Shall be aranged by contractor.
Supply and fixing breather including silica gel, indicating type, 4 to 6 mm standard size of the particle, blue colour for transformer of capacity from 63 to 500 kVA including removing of old breather complete all as specified and directed.
Supply and fixing cork sheet gasket of 5mm thick best quality including arresting leakage of transformer oil by after draining out of transformer oil and refilling after replacement including disconnecting power supply complete all as specified and as directed for distribution transformer outdoor type 11 kV /415 volts having capacity upto 500 kVA complete all as specified and as directed by Engr-in-charge.
Materials and labour for spray painting of transformers (any type power or distribution)) of capacity upto and including 500 kVA ( in situ ) outdoor type, installed and located at different sites in scattered area under the AGE E/M including the following: - (a) preparation of old surfaces by cleaning, scrapping, rubbing/ polishing etc. complete. (b) painting with two coats of Duco paint (Grey) paint of approved make / quality all as directed at site. (c) Writing the SM MES No of transformer on MS body of transformer all as directed .
Supply only electrical insulation gloves, Type-4, test potential 25 KV, working voltage 17 KV as per IS 4770 complete all as specified and directed.
Supply only HT tape complete all as specified and as directed.
Material and labour for trimming of various sizes of tree branches which are touching / close to HT over head line at various place and clear the HT over head line upto 3.00 metre from conductor complete all as specified and directed. (Note: (a) All the safety equipments, cutting materials, ladder etc requirred for the work to be provided by the contractor. (b) The cutting shall be done two times during the contract period on as required basis. (c) Before and after photograph and video recording of the work will be done and kept on record.)
Clearing of the shrubs, vegetation grass, bushes, plants and saplings grown below HT line around the stay and all substation in the area and cleaning the rubbish materials and dumping at places as directed complete all as specified and directed.
Material and labour for pouring distilled water for battery bank of 33/11 KV MRS Sub Station complete all as specified and directed.
Supply & Fixing in replacment of 33 KV Outdoor Type CT, Ratio - 100-50A/5-5A, VA-15, Class - 0.5, 5P 10 solid earth rated frequency 50 HZ system failure -25 Kafor 3 Sec all as specified and directed. Make - APDCL approved quality with standard 7s 2099 (Indian Electricity Rule 2003) (a) Type 3 phase accuracy class 0.2S CT (b) Rated primary current upto 200-400 A and secondary 5/1 Amp in CT (c) Rated primary 33 KV secondary 110 PT (d) Rated burden - 5 VA (0.8 Lagging PF per phase in CT) (e) Rated burden 30 VA (0.8 Lagging PF per Phase in PT) (f) Current density 1.5 Amp/sqmm (g) Instrument security factor less then 5 (h) Max allowable temp rise 50 *C (CT & PT) (i) Winding of material sopper (CT & PT) (j) Dynamic current - 40 ka
Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced to earthing lead of 32mm x 6mm galvanised mild steel strip by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking out unserviceable earthing plate and accessories all as specified and as directed. (Note: Earth lead upto a length of 7.50 m from earthplate shall be deemed to be included in quoted rate.)
M&L for brick work with subclass "B" bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed.
Material and labour for rendering 15 mm thick plaster in cement mortar (1:4) on fair faces of brick work or concrete surfaces and finished the surface even and smooth without using extra cement complete all as specified and directed.
Materials and labour for PCC (1:2:4), type B1 (using 20mm graded stone aggregate), set in cement mortar (1:4) having 10cm thickness complete all as specified and directed.
Materials and labour for PCC 1:3:6 type C2 (using 40mm graded stones) as in PCC foundation complete all as specified and directed by Engr-in-Charge
Materials and labour for 100mm thick hardcore of broken stone/boulder, gauge n. exc. 63 mm, spreading, levelling and compacting to a true surface complete all as specified and directed.
Materials and labour for multifunctional meter of size 96 x 96mm, with RS485, Class 0.5, input voltage measurement range 50-520 VAC (P-P) complete with digital display & LCD back light showing electrical parameters such as VLL, VLN, A, F, PF, On Hrs, RPM, Apeak including dismnatling of old UNSV one complete all as specified and directed. Model: 4110 Series, Cat No WL411021OOOO of L&T
Supply and fixing jumper connection by using ACSR (MINK) including necessary lugs, nuts bolts and alkathline pipe with colour code (RYB) suitable for 11000 Volts complete all as specified and directed. Note: Jumper connections from HT bus bar to GOD, DO, LA connections for three phase will be measured as one job
Materials and labour in repair for replacing danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with mild steel clamps, bolts and nuts of approved size, for HT 11000 Volts, 250 mm X 200 mm complete all as specified and as directed by Engr-in-charge.
Materials and labour for preparation of old painted surfaces of HT 4/2 pole structure (11 metre long) by applying two coats black synthetic enamel paint (1st grade quality) upto a height of 1 mtr from the ground level and two coats of aluminium paint over the remaining portion of pole including crossarms, bracing etc complete all as specified and as directed. Note: Necessary T&P for painting the 4 pole structure has to be arranged by the contractor.
Materials and labour for preparation of old painted surfaces of HT 2 pole structure (11 metre long) by applying two coats black synthetic enamel paint (1st grade quality) upto a height of 1 mtr from the ground level and two coats of aluminium paint over the remaining portion of pole including crossarms, bracing etc complete all as specified and as directed. Note: Necessary T&P for painting the 4 pole structure has to be arranged by the contractor.
Supply only HT DO fuse element 11KV, 20 A rating. Make: Electro Comfort/L&T/C&S
Supply only HT DO fuse element 11KV, 30 A rating. Make: Electro Comfort/L&T/C&S
Supply only HT DO fuse element 11KV, 40 A rating. Make: Electro Comfort/L&T/C&S
Supply only HT DO fuse element 11KV, 60 A rating. Make: Electro Comfort/L&T/C&S
M/S Satish Chand Agarwal
APPLE CONSTRUCTION
M/S PIJUSH BHATTACHARJEE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .