Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.8 LAccepted-AOC 13 218 MASJID EXTEN SADAR BAZAR | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹19.8 L+₹1.0 L (5.47%)Rejected-Finance | L2 | Rejected-Finance Not the lowest tenderer | |
| 3 | L3₹20.3 L+₹1.5 L (8.10%)Rejected-Finance | L3 | Rejected-Finance Not the lowest tenderer | |
| 4 | L4₹20.3 L+₹1.5 L (8.16%)Rejected-Finance | L4 | Rejected-Finance Not the lowest tenderer | |
| 5 | L5₹21.1 L+₹2.3 L (12.0%)Rejected-Finance | L5 | Rejected-Finance Not the lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
4 Jan 2021, 6:00 pmClosed
Garrison Engineer South Delhi Cantt 110010
Delhi Cantt 110010
REPAIR/ REPLACEMENT OF DBs SUBMAIN WIRING BLDG SECURITY LIGHTS, EARTHING AND CONNECTED WKS IN OTM AND MD ACCN AT IHQ MOD (ARMY) CAMP HQ DGIS CAMS 1 CBPO/PLI 10 JAK LI KHYBER LINE AND VRC UNDER AGE E/M (S) OF GE (SOUTH) DELHI CANTT-10
2020_MES_401370_1
GE/DS-55/2020-21
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer South Delhi Cantt 110010
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer South Delhi Cantt 110010
₹50,000
Yes
19 Feb 2021
7 Dec 2020
6 Jan 2021
7 Dec 2020
4 Jan 2021
21 Dec 2020
8 Dec 2020 - 19 Dec 2020
Amount
S&F in replacement of distribution board triple pole and neutral 4 way for fixing MCCB up to 125 to 250 Amps as incomer and MCBs as out goings with metal door IP 43 Protections and connecting complete all as specified and directed by Engineer-in-charge. (Make : Benlo Cat Pt No : BEMD250T4 or its equivalent as Legrand/ABB/Siemens).
S&F in replacement of distribution board triple pole and neutral 8 way (VTPN) for fixing MCCB up to 125 to 250 Amps as incomer and MCBs as out goings with metal door IP 43 Protections and connecting complete all as specified and directed by Engineer-in-charge. (Make : Benlo Cat Pt No : BEMD250T8 or its equivalent as Legrand/ABB/Siemens)
S&F in replacement MCB DB SPN 12 Way double door type, (IP 43 Protection) flush mounting complete all as specified and directed by Engineer-in-charge. (Make : Legrand Cat part No. 607711 or its equivalent model of ABB/Benlo)
S&F in replacement MCB DB SPN 4 Way double door type, (IP 43 Protection) flush mounting complete all as specified and directed by Engineer-in-charge. (Make: Benlo Cat part No. BESDC04 or its equivalent : Legrand/Havells/Indoasian)
S&F in replacement MCB DB SPN 8 Way double door type,(IP 43 Protection) flush mounting complete all as specified and directed by Engineer-in-charge. (Make : Benlo Cat part No. BESDC08 or its equivalent as Legrand/Havells/Indoasian)
S&F in replacement single pole and neutral sheet metal enclosures with 2 pin earth plug and socket complete with one no MCB SP upto 20 Amps as per site requirement of existing type complete all as specified and directed by Engineer-in-charge.
S&F in replacement MCCB 3 Pole 415V, Adjustable type, 100/125 Amps with breaking capacity 25 KA complete all as specified and directed by Engineer-in-charge.. (Make of MCCB : Cat Pt No : F3125M3P of Benlo or its equivalent Legrand/Havells/Indoasian)
S&F in replacement MCCB 3 pole, 415V, Adjustable type,160 Amps with breaking capacity 35 KA complete all as specified and directed by Engineer-in-charge. (Make of MCCB : Cat Part No F3160H3P of Benlo or its equivalent Legrand/Havells/Indoasian)
S&F in replacement MCCB 3 pole 250 Amps 35 KA 415 Volts with breaking capacity 50 KA, complete all as specified and directed by Engineer-in-charge. (Make of MCCB : Cat Pt No : F3250L3P of Benlo or its equivalent Legrand/Havells/Indoasian)
S&F in replacement for MCB SP 10 to 40 Amps 240 Volts, 10 KA, `C' curve, all as per site requirement complete all as specified and directed by Engineer-in-charge.
S&F in replacement for MCB 40 Amps, 240 Volts, 10 KA, `C' curve, all as per site requirement complete all as specified and directed by Engineer-in-charge.
S&F in replacement MCB TPN/ Isolator 4P from 63 Amps 415 volts, 'C' Series 10 KA as per site requirement complete all as specified and directed by Engineer-in-charge.
M&L 'in replacement' submain wiring PVC insulated FRLS single core with stranded copper cable of size 6 Sqmm in 2 runs and 6 Sqmm one run for earth drawing through existing PVC conduit 25 mm dia complete all as specified and directed by Engineer-in-charge. Note:- Two runs of main cable and one run of earth cable all-together shall be considered as one length)
M&L 'in replacement' submain wiring PVC insulated FRLS single core with stranded copper cable of size 4 Sqmm in 2 runs and 4 Sqmm one run for earth drawing through existing concealed PVC conduit 20 mm dia complete all as specified and directed by Engineer-in-charge. Note:- Two runs of main cable and one run of earth cable all-toghter shall be considered as one length)
M&L 'in replacement' submain wiring PVC insulated FRLS single core with stranded copper cable of size 10 Sqmm in 2 runs and 6 Sqmm one run for earth drawing through existing PVC conduit 25 mm dia conduit complete all as specified and directed by Engineer-in-charge. Note:- Two runs of main cable and one run of earth cable all-toghter shall be considered as one length)
S&F in replacement MS fastner bolt 8mm dia and 100mm (Min.) long for fixing geyser/ Exhaust fan/Bldg security light etc with nut and washer complete all as specified and directed by Engineer-in-charge.
S&F in replacement LED post top lantern fitting with die cast aluminium spigot, spun aluminum powder coated top cover Aluminum PDC heat sink opal PC diffuser clear acrylic IP-65 with 25 Watt power including all accessories connecting up twisted flexible copper conductor cable of suitable size of 230 V, 50 Hz complete including making a hole in pillar/wall with light grade GI pipe of suitable size for fixing the post top lanter fitting complete all as specified and directed by Engineer-in-charge at site with Make:- Cat part No HLPT-04-25-CW of Halonix or its equivalent CG/Bajaj/Phillips).
S&F LED Building security light fitting 30W on existing bracket in replacement of old unsv existing security light fitting any type complete all as specified and directed by Engineer-in-charge.
M&L for GI pipe's bracket suitable for fixing of bldg security LED light fitting of 30/45 Watts including grouting and fixing the same on wall for installation of light fitting with necessary clamps, nut, bolts & washer and painting by synthetic enameled good quality paint in white/grey colour over one coat of red oxide primer until unless smoothness of bracket complete all as specified and directed by Engineer-in-charge. Note : GI pipe should be 40 mm bore dia with medium grade and the same to be moulded in 45 degree angle at the 1 Mtr height to fix the building security light fitting)
M&L for earthing complete with GI earth plate electrode 600 x 600 x 6mm thick burried directly in ground in ground (earth pit plate kess than 2.5 mtrs below ground level) with top edge of the plate not less than 1.5 mtrs deep below normal ground level, connected to galvanised earth wire 4mm by means of bolts, nuts check nuts to earth test point including necessary PCC 1:2:4 type B-1 pit, cover frame, GI pipe 15mm dia light grade with funnel and locking arrangement complete all as specified and directed by Engineer-in-charge.
M&L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicate dsituation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and directed by Engineer-in-charge.
Note:- The contract sum shall be after deducting the amount of Credit shown in Credit Schedule of this Tender.
M/s KUNDU CONSTRUCTION
Bluemax Associate
ramveer Singh
Microsys Controls India
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .