Supply installation and commissioning of 33kV and 11kV CTs and PTs indoor outdoor in all electrical circles of APDCL
2023_APDCL_33105_1
APDCL/CGM(PPD)/CTs-PTs/22-23/4
Open Tender
Electrical Works
Turn-key
180 days
All Electrical circles of APDCL
Please refer Tender documents.
3 documents required · 3 mandatory
₹9,000
₹10 L
Yes
Bijulee Bhawan Guwahati
30 Jul 2024
16 Oct 2023
30 Nov 2023
16 Oct 2023
29 Nov 2023
28 Oct 2023
16 Oct 2023 - 25 Oct 2023
25 Oct 2023
Supply, Installation and Commissioning of 33kV and 11 kV CTs and PTs (Indoor/Outdoor) in all Electrical Circles of APDCL
Description of Work / Item(s)
Supply,fitting and fixing of 11KV/√3/110V/√3 Accuracy Class:0.5, 1ph Indoor PT
Supply,fitting and fixing of 11KV/110V 1ph Outdoor PT with marshaling box & connector (Set comprising of three units), Accuracy class: 0.5
Supply,fitting and fixing of 11kV 0.5s Accuracy Class 1ph Indoor Wound type CT 600-300/5-5-5A, 25kA for 3 sec
Supply,fitting and fixing of 11kV 0.5s Accuracy Class 1ph Indoor Wound type CT 400-200/5-5A, 25kA for 3 sec
Supply,fitting and fixing of 11kV 0.5s Accuracy Class 1ph Indoor Wound type CT 300-150/5-5A, 25kA for 3 sec
Supply,fitting and fixing of 11kV 0.5s Accuracy Class 1ph Indoor Wound type CT 200-100/5-5A, 25kA for 3 sec
Supply,fitting and fixing of 11kV 0.5s Accuracy Class 1ph Outdoor CT with marshaling box & connector 600-300/5-5-5A, 25kA for 3 sec (Set comprising of three units)
Supply,fitting and fixing of 11kV 0.5s Accuracy Class 1ph Outdoor CT with marshaling box & connector 600-300/1-1-1A, 25kA for 3 sec (Set comprising of three units)
Supply,fitting and fixing of 11kV 0.5s Accuracy Class 1ph Outdoor CT with marshaling box & connector 400-200/5-5A, 25kA for 3sec (Set comprising of three units)
Supply,fitting and fixing of 11kV 0.5s Accuracy Class 1ph Outdoor CT with marshaling box & connector 300-150/5-5A, 25kA for 3sec (Set comprising of three units)
Supply,fitting and fixing of 11kV 0.5s Accuracy Class 1ph Outdoor CT with marshaling box & connector 200-100/5-5A, 25kA for 3sec (Set comprising of three units)
Supply,fitting and fixing of 33KV/√3/110V/√3 Accuracy Class:0.5 1ph Outdoor PT with marshaling box & connector (Set comprising of three units)
Supply,fitting and fixing of 33kV 0.5s Class 1ph Outdoor CT with marshaling Box (Set comprising of three units) 400-200/5-5-5A, 25kA for 3 sec
Supply,fitting and fixing of 33kV 0.5s Class 1ph Outdoor CT with marshaling Box (Set comprising of three units) 600-300/5-5A, 25kA for 3 sec
Supply,fitting and fixing of 33kV 0.5s Class 1ph Outdoor CT with marshaling Box (Set comprising of three units) 400-200/5-5 A, 25kA for 3 sec
Supply,fitting and fixing of 33kV 0.5s Class 1ph Outdoor CT with marshaling Box (Set comprising of three units) 200-100/5-5-5 A, 25kA for 3 sec
Supply,fitting and fixing of 33kV 3 Ph 4W Combined CT/PT Accuracy Class: 0.2, 400/5A, STC: 25kA for 1 Sec
Supply,fitting and fixing of 33kV 3 Ph 4W Combined CT/PT Accuracy Class: 0.2, 200/5A, STC: 25kA for 1 Sec
Purbanchal Enterprise
Purbanchal Enterprise
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .