Loading…
Loading…
Tender ID
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
17 Apr 2026, 12:00 pmClosed
THE DY. DIRECTOR OF HEALTH SERVICES (E AND S)
Central Medical Stores,141, A J C Bose Road, Kolkata- 700014
RE E-TENDER FOR PROCUREMENT OF CONSUMABLE ITEMS FOR TWO YEARS FROM THE DATE OF AWARD OF CONTRACT (AOC)
2026_HFW_1022398_1
WBHF/CMS/ HST/1P-153-2025/CI-RT (369)/2026/385
Open Tender
Equipments
Item Wise
730 days
KOLKATA
Please refer Tender documents.
3 documents required · 3 mandatory
₹1 L
Yes
30 Mar 2026
13 Mar 2026
17 Apr 2026
13 Mar 2026
17 Apr 2026
30 Mar 2026
TECHNICAL DATA SHEET
Tender NIT No. : HST/1P-153-2025/CI-RT (369)/2026/385 Dated: 13-03-2026
Tender inviting Authority : The Deputy Director of Health Services (E&S)
Bidder's Name :
Sl. No. Cat. No. Item Name with Specification , as provided in the Tender documents Accounting Unit Drug Item Item Specification, offered by the Bidder with documents Accounting Unit quoted by the Bidder in the BOQ Quoted as Manufacturer/ Importer for the item License No under which the item is endorsed. (BIS No. In case of items having IS Specification) Name of the folder & Page No. in which Drug Endorsement/F-10, submitted, Name of the folder & Page No. in which Market Standing/ Marketing Cetificate, submitted Remarks (page no of supportive Documents for non submission of any documents )
1 A24.01/C APD Cassette 4 Prong Specification : Automated PD set W/4 Prong cassette ; 4 inlets ; 1 outlet; 1 patient connect more than 5ft tube; compatible with APD cycler EACH Drug
2 B14.01/C Bone cement 40 gm Pack (Regular Viscosity & Low Viscosity) with Gentamycin : Methyl Methacrylate / Methyl acrylate copolymer blend Sterilised using ethylene oxide gas EACH Drug
3 B14.01/CI Bone currete (Small / Medium / Large) Each Drug
4 C1.01/C Cannula, Aortic Arch Cannula - Neonatal : Straight Tip, Soft Flexible bodyenables easy poioning yet resist kinking, 8Fr ( 2.7 mm), 1/4 Connector, CE / USFDA Certified. EACH Drug
5 C12.01/C Cannula, Vessel Cannula : Clear body, soft plastic tip, female luer lock. Size : 3 mm Blunt tip EACH
6 C3.01/C CANNULA, Cardiopledigia Cannula (Neontal) : Radiopaque tips attached to clear bodies , left heart venting long tip and standard introducer. Size : 14 ga (7 Fr.) EACH
7 C3.02/C CANNULA, Cardiopledigia Cannula (Paediatric) : Radiopaque tips attached to clear bodies with separate vent lines , include aortic root pressure monitoring and left heart venting. Size : 16 ga (5 Fr.) EACH
8 C41.01/C Diagnostic Glide catheter for Abdominal angiographiy Size: 5Fr & 6 Fr. • Should be Hydrophilic polymer coated catheter. • Should be soft tip is installed on distal end. • Should be available Different shape type. EACH
9 C41.02/C Diagnostic Glide catheter for Cerebral angiographiy Size: 5Fr & 6 Fr.• Should be Hydrophilic polymer coated catheter.• Should be soft tip is installed on distal end.• Should be available Different shape type. EACH
10 C44.01/C DISPOSABLE NEEDLES 18G Pack of 100 PCS
11 C45.01/C CA 250 Line Specification: CA 250 Line - Prismaflex Calcium line/ CA250 lines: Used with Regional Citrate Anticoagulation for compensating patients Calcium EACH
12 C5.01(a)/C Cannula, Long femoral arterial cannula of sizes (15 Fr/17 Fr/19 Fr/ 21 Fr/ 23 Fr) or ( 16 Fr/18 Fr/ 20 Fr/ 22 Fr/ 24 Fr) with multiple side holes, wire reinforced and Kink resistant, thin walled, smooth tip with radio opaque marker for easy percutaneous insertion along with insertion kit containing dilator set of various sizes, two trip guide wires ( 0.038 ‘’) 100 cm & 150 cm in length, 18G puncture needle & mini scalpes. EACH
13 C8.01/C Cannula, Retrograde Cardiopledgia Cannula : silicone bodies and auto inflate cuff with pressure monitoring lines . A variety of cuffs with stylets. EACH
14 C9.02/C CANNULA, SINGLE STAGE VENOUS CANNULA, MALLEABLE, WIRE REINFORCED PAEDIATRIC WITH MULTIPORT AND DIFFERENT TYPES OF TIPS EACH
15 D01.01/E DENTAL CHAIR SPECIFICATION AS PER NIT EACH
16 D12.01/C Disposable Convective warming Blanket, Should have wide range of disposable blankets for variety of patient sizes and positions.*Blankets must have 2 layers of non-woven polypropylene fabric bonded to a layer of polyethylene for durability and to prevent tearing and puncturing. EACH
17 D28.01/C Dental Probe with mirror set EACH
18 D29.01/C Double Layered (3 ply) Washable Green Mask. EACH
19 E24.01/C Examination lamp EACH
20 F16.01/C Forceps, Rat Tooth Retrieval Forceps 4fr, 65 cm EACH
21 F16.02/C Forceps, Rat Tooth Retrieval Forceps 3.3fr / 4fr, 115 cm / 210 cm EACH
22 L4.01/C LINT ABS. IN PKTS. OF 400 GMS NET Each
23 L5.01/C Long Guide wire Platinum micro guide wire 10, 14 and 16. EACH
24 M1.01/C MACKINTOSH DOUBLE COLOUR WATER PROOF, ROLL LENGTH NOT MORE THAN 30 MTR & WIDTH OF THE ROLL SHOULD BE 1 MTR, BIS 4135:1974 CERTIFIED PER METER
25 M25.01/C Metallic Suction Cannula - (Small / Medium / Large) Each
26 M5.01/C Micro Guiding catheter size • Distal Dia – 1.8Fr. & Proximal Dia – 2.6Fr. • Catheter length-130 & 150 cm.• Hydrophilic coating with PTFE inner layer.• Gold marker for enhanced distal tip visibility. EACH
27 M5.02/C Microcatheter: Microcatheter constructed with Nylon and available in 10 and 14 system coils. EACH
28 M31.01/C Manual PD Drain Bag 2 Lits Specification: CAPD Sample disconnect set for 2 Its compatible PD bags compatible with patient used transfer set EACH
29 O9.01/C Oximetry Cable for CCO Monitor (Reusable) Each
30 O21.01/C Oxiris Specification: Having three layers for removing Cytokines, Endotoxins and performing CRRT altogether. AN69 layer removes Cytokines, PEI layers remove Endotoxins and a Heparin graft is present for maintaining thrombogenecity. Applicable for more than 30kg patient. Filter surface area 1.5m2. Extracorporeal Blood Bolume: 193ml. Specifically indicated for Sepsis+AKI EACH
31 P84.01/C Peel apart Introducer for Tenckhoff catheter Each
32 P86.01/C Prismaflex HF20 Specification: Filter having PAES Membrane for more bio compatibility, Applicable for 8-11kg patient. Filter surface area 0.2 m2. Extracorporeal Blood Volume: 58ml. Each
33 P86.02/C Prismaflex M60 Specification: Filter having AN69 Membrane , Applicable for 11-30kg patient. Filter surface area 0.6m2. Extracorporeal Blood Bolume: 93ml. Each
34 P86.03/C Prismaflex M100 Specification : Filter having AN69 Membrane , Applicable for more than 30kg patient. Filter surface area 0.9m2. Extracorporeal Blood Bolume: 152 ml. Each
35 P86.04/C Prismaflex M150 Specification : Filter having AN69 Membrane , Applicable for more than 30kg patient. Filter surface area 1.5m2. Extracorporeal Blood Bolume: 189 ml. Each
36 P4.01/C Plasma Filter for Plasmapheresis EACH
37 P82.01/C Platinum Chromium Coronary Stent System EACH
38 S122.01/C Stadiometer EACH
39 S128.01/C Steriliser, Low Temperature Gas Plasma Sterilization System : Unit Dimension : 1) Height/Depth/Width: 840/840/560 mm 2) Door Width (Radius)/ Angle: 560 mm/100 deg 3) Unit Weight: 125 Kg Cart : 1) Cart Dimension (H/D/W): 560/735/610 mm 2) Cart Weight: 35 Kg Chamber: 1) Chamber Dimension (H/D/W): 200/610/330 mm 40 Liters (30 liters usable Volume) 2) Shelf Dimension (2 shelves) : 610/330 mm 3) Height Distance between shelf/chamber: 80 mm 4) Max weight per shelf: 11.3 kg Electrical : 1) Voltage/ Max Current: 99 – 132 VAC, 47-63 HZ, 16A 180 -264 VAC, 47 -63 Hz, 10A 2) Standard Plug Country Specific 3) 63Max. Power consumption: 2000W 4) Cycle Temparature: 50-55 deg C Total Cycle time : 28 min and 38 min Network : Interfce : Ethernet Each
40 S131.01/C STERILIZER, INSTRUMENT STERILIZER MADE OF STEEL, HOT AIR, WITH AUTOMATIC ADJUSTABLE TEMPERATURE REGULATOR FROM 120C-200C/ 220-AC/DC. INSIDE MEASUREMENT: 600MM. X 600MM. X 600 MM. (2 FT. X 2 FT. X 2 FT.)(Hot Air Sterilizers) Each
41 S144.01/C Stiff PD catheter (Paediatric) Specification : Stiff Tenckhoff-type catheter for peritoneal dialysis (PD), suitable for surgical, laparoscopic, or percutaneous insertion. Designed for optimal inflow/outflow, with biocompatible materials for temporary or permanent access. Material (• Medical-grade biocompatible silicone • Non-toxic, non-pyrogenic, latex-free, DEHP-free •Radiopaque for X-ray visibility)• Straight or curved configuration with double Dacron cuffs • Multiple side holes near tip for optimal dialysate flow • Includes removable/fixed stiffening wire or stylet. Outer Diameter (OD)-3.5–4.5 mm (10–12 Fr).Length - 30–36 cm. Cuff Position- Proximal: 1–2 cm from exit , Distal: 6–8 cm from tip.Two (double cuffed), Straight (preferred). Accessories(• Stylet or stiffening wire • Tunneler • Trocar (if applicable) • Transfer set connector/adaptor • End cap • Sterile pack with user manual)• ETO sterilized or equivalent • Shelf life: Minimum 3 years • SAL: 10⁻⁶. • CE marked / US FDA / CDSCO approved • Manufacturer must be ISO 13485 certified.• Individually sterile-packed • Label must include product code, size, expiry, batch number, manufacturer, sterilization method.• Supplier to provide user training/demo if needed • Certificate of Analysis (CoA) and sterility certificate with each batch • Warranty against manufacturing defects Each
42 V15.01/C Vp Shunt (Programmable/ Antibiotic Impregnated) Each
43 H5.05/C HEAD LIGHT WITH COLD LIGHT SOURCE WITH ALL ACCESSORIES 1. FIBRE OPTIC CABLE, 2. HEAD BAND, 3. LIGHT SOURCES, 4. SOLAR LAMP One complete Set
43.1 H5.01/C HEAD LIGHT WITH COLD LIGHT SOURCE - FIBRE OPTIC CABLE EACH
43.2 H5.02/C HEAD LIGHT WITH COLD LIGHT SOURCE - HEAD BAND EACH
43.3 H5.03/C HEAD LIGHT WITH COLD LIGHT SOURCE - LIGHT SOURCES EACH
43.4 H5.04/C HEAD LIGHT WITH COLD LIGHT SOURCE - SOLAR LAMP EACH
Select, Excess (+), Less (-)
Tender Inviting Authority: THE DEPUTY DIRECTOR OF HEALTH SERVICES (E&S), CENTRAL MEDICAL STORES, KOLKATA -700 014
Name of Work: RE E-TENDER FOR PROCUREMENT OF CONSUMABLE ITEMS FOR TWO YEARS FROM THE DATE OF AWARD OF CONTRACT (AOC)
Contract No: HST/1P-153-2025/CI-RT (369)/2026/385 Dated: 13-03-2026
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Item Name GROUP-I Cat. No. Tentative requirement for the period as per AU Accounting Unit Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency Basic Rate should be as per Clause No. 16(d). of the NIT, PG:12 Rs. P GST in % Excise Duty in % Cess in % Any Other Taxes/Duties/Levies in Rs. P Other Taxes 2in Rs. P IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax in Rs. P Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category in Rs. P
1 APD Cassette 4 Prong Specification : Automated PD set W/4 Prong cassette ; 4 inlets ; 1 outlet; 1 patient connect more than 5ft tube; compatible with APD cycler A24.01/C 324000 EACH Excess(+) Full Conversion INR
2 Bone cement 40 gm Pack (Regular Viscosity & Low Viscosity) with Gentamycin : Methyl Methacrylate / Methyl acrylate copolymer blend Sterilised using ethylene oxide gas B14.01/C 1000 EACH Excess(+) Full Conversion INR
3 Bone currete (Small / Medium / Large) B14.01/CI 100 Each Excess(+) Full Conversion INR
4 Cannula, Aortic Arch Cannula - Neonatal : Straight Tip, Soft Flexible bodyenables easy poioning yet resist kinking, 8Fr ( 2.7 mm), 1/4 Connector, CE / USFDA Certified. C1.01/C 70 EACH Excess(+) Full Conversion INR
5 Cannula, Vessel Cannula : Clear body, soft plastic tip, female luer lock. Size : 3 mm Blunt tip C12.01/C 150 EACH Excess(+) Full Conversion INR
6 CANNULA, Cardiopledigia Cannula (Neontal) : Radiopaque tips attached to clear bodies , left heart venting long tip and standard introducer. Size : 14 ga (7 Fr.) C3.01/C 15 EACH Excess(+) Full Conversion INR
7 CANNULA, Cardiopledigia Cannula (Paediatric) : Radiopaque tips attached to clear bodies with separate vent lines , include aortic root pressure monitoring and left heart venting. Size : 16 ga (5 Fr.) C3.02/C 180 EACH Excess(+) Full Conversion INR
8 Diagnostic Glide catheter for Abdominal angiographiy Size: 5Fr & 6 Fr. • Should be Hydrophilic polymer coated catheter. • Should be soft tip is installed on distal end. • Should be available Different shape type. C41.01/C 25 EACH Excess(+) Full Conversion INR
9 Diagnostic Glide catheter for Cerebral angiographiy Size: 5Fr & 6 Fr.• Should be Hydrophilic polymer coated catheter.• Should be soft tip is installed on distal end.• Should be available Different shape type. C41.02/C 200 EACH Excess(+) Full Conversion INR
10 DISPOSABLE NEEDLES 18G C44.01/C 4500 Pack of 100 PCS Excess(+) Full Conversion INR
11 CA 250 Line Specification: CA 250 Line - Prismaflex Calcium line/ CA250 lines: Used with Regional Citrate Anticoagulation for compensating patients Calcium C45.01/C 600 EACH Excess(+) Full Conversion INR
12 Cannula, Long femoral arterial cannula of sizes (15 Fr/17 Fr/19 Fr/ 21 Fr/ 23 Fr) or ( 16 Fr/18 Fr/ 20 Fr/ 22 Fr/ 24 Fr) with multiple side holes, wire reinforced and Kink resistant, thin walled, smooth tip with radio opaque marker for easy percutaneous insertion along with insertion kit containing dilator set of various sizes, two trip guide wires ( 0.038 ‘’) 100 cm & 150 cm in length, 18G puncture needle & mini scalpes. C5.01(a)/C 50 EACH Excess(+) Full Conversion INR
13 Cannula, Retrograde Cardiopledgia Cannula : silicone bodies and auto inflate cuff with pressure monitoring lines . A variety of cuffs with stylets. C8.01/C 60 EACH Excess(+) Full Conversion INR
14 CANNULA, SINGLE STAGE VENOUS CANNULA, MALLEABLE, WIRE REINFORCED PAEDIATRIC WITH MULTIPORT AND DIFFERENT TYPES OF TIPS C9.02/C 130 EACH Excess(+) Full Conversion INR
15 DENTAL CHAIR SPECIFICATION AS PER NIT D01.01/E 80 EACH Excess(+) Full Conversion INR
16 Disposable Convective warming Blanket, Should have wide range of disposable blankets for variety of patient sizes and positions.*Blankets must have 2 layers of non-woven polypropylene fabric bonded to a layer of polyethylene for durability and to prevent tearing and puncturing. D12.01/C 3000 EACH Excess(+) Full Conversion INR
17 Dental Probe with mirror set D28.01/C 2400 EACH Excess(+) Full Conversion INR
18 Double Layered (3 ply) Washable Green Mask. D29.01/C 100000 EACH Excess(+) Full Conversion INR
19 Examination lamp E24.01/C 1200 EACH Excess(+) Full Conversion INR
20 Forceps, Rat Tooth Retrieval Forceps 4fr, 65 cm F16.01/C 50 EACH Excess(+) Full Conversion INR
21 Forceps, Rat Tooth Retrieval Forceps 3.3fr / 4fr, 115 cm / 210 cm F16.02/C 100 EACH Excess(+) Full Conversion INR
22 LINT ABS. IN PKTS. OF 400 GMS NET L4.01/C 35000 Each Excess(+) Full Conversion INR
23 Long Guide wire Platinum micro guide wire 10, 14 and 16. L5.01/C 35 EACH Excess(+) Full Conversion INR
24 MACKINTOSH DOUBLE COLOUR WATER PROOF, ROLL LENGTH NOT MORE THAN 30 MTR & WIDTH OF THE ROLL SHOULD BE 1 MTR, BIS 4135:1974 CERTIFIED M1.01/C 70000 PER METER Excess(+) Full Conversion INR
25 Metallic Suction Cannula - (Small / Medium / Large) M25.01/C 2000 Each Excess(+) Full Conversion INR
26 Micro Guiding catheter size • Distal Dia – 1.8Fr. & Proximal Dia – 2.6Fr. • Catheter length-130 & 150 cm.• Hydrophilic coating with PTFE inner layer.• Gold marker for enhanced distal tip visibility. M5.01/C 80 EACH Excess(+) Full Conversion INR
27 Microcatheter: Microcatheter constructed with Nylon and available in 10 and 14 system coils. M5.02/C 160 EACH Excess(+) Full Conversion INR
28 Manual PD Drain Bag 2 Lits Specification: CAPD Sample disconnect set for 2 Its compatible PD bags compatible with patient used transfer set M31.01/C 648000 EACH Excess(+) Full Conversion INR
29 Oximetry Cable for CCO Monitor (Reusable) O9.01/C 60 Each Excess(+) Full Conversion INR
30 Oxiris Specification: Having three layers for removing Cytokines, Endotoxins and performing CRRT altogether. AN69 layer removes Cytokines, PEI layers remove Endotoxins and a Heparin graft is present for maintaining thrombogenecity. Applicable for more than 30kg patient. Filter surface area 1.5m2. Extracorporeal Blood Bolume: 193ml. Specifically indicated for Sepsis+AKI O21.01/C 200 EACH Excess(+) Full Conversion INR
31 Peel apart Introducer for Tenckhoff catheter P84.01/C 600 Each Excess(+) Full Conversion INR
32 Prismaflex HF20 Specification: Filter having PAES Membrane for more bio compatibility, Applicable for 8-11kg patient. Filter surface area 0.2 m2. Extracorporeal Blood Volume: 58ml. P86.01/C 250 Each Excess(+) Full Conversion INR
33 Prismaflex M60 Specification: Filter having AN69 Membrane , Applicable for 11-30kg patient. Filter surface area 0.6m2. Extracorporeal Blood Bolume: 93ml. P86.02/C 250 Each Excess(+) Full Conversion INR
34 Prismaflex M100 Specification : Filter having AN69 Membrane , Applicable for more than 30kg patient. Filter surface area 0.9m2. Extracorporeal Blood Bolume: 152 ml. P86.03/C 250 Each Excess(+) Full Conversion INR
35 Prismaflex M150 Specification : Filter having AN69 Membrane , Applicable for more than 30kg patient. Filter surface area 1.5m2. Extracorporeal Blood Bolume: 189 ml. P86.04/C 250 Each Excess(+) Full Conversion INR
36 Plasma Filter for Plasmapheresis P4.01/C 200 EACH Excess(+) Full Conversion INR
37 Platinum Chromium Coronary Stent System P82.01/C 100 EACH Excess(+) Full Conversion INR
38 Stadiometer S122.01/C 1800 EACH Excess(+) Full Conversion INR
39 Steriliser, Low Temperature Gas Plasma Sterilization System : Unit Dimension : 1) Height/Depth/Width: 840/840/560 mm 2) Door Width (Radius)/ Angle: 560 mm/100 deg 3) Unit Weight: 125 Kg Cart : 1) Cart Dimension (H/D/W): 560/735/610 mm 2) Cart Weight: 35 Kg Chamber: 1) Chamber Dimension (H/D/W): 200/610/330 mm 40 Liters (30 liters usable Volume) 2) Shelf Dimension (2 shelves) : 610/330 mm 3) Height Distance between shelf/chamber: 80 mm 4) Max weight per shelf: 11.3 kg Electrical : 1) Voltage/ Max Current: 99 – 132 VAC, 47-63 HZ, 16A 180 -264 VAC, 47 -63 Hz, 10A 2) Standard Plug Country Specific 3) 63Max. Power consumption: 2000W 4) Cycle Temparature: 50-55 deg C Total Cycle time : 28 min and 38 min Network : Interfce : Ethernet S128.01/C 10 Each Excess(+) Full Conversion INR
40 STERILIZER, INSTRUMENT STERILIZER MADE OF STEEL, HOT AIR, WITH AUTOMATIC ADJUSTABLE TEMPERATURE REGULATOR FROM 120C-200C/ 220-AC/DC. INSIDE MEASUREMENT: 600MM. X 600MM. X 600 MM. (2 FT. X 2 FT. X 2 FT.)(Hot Air Sterilizers) S131.01/C 200 Each Excess(+) Full Conversion INR
41 Stiff PD catheter (Paediatric) Specification : Stiff Tenckhoff-type catheter for peritoneal dialysis (PD), suitable for surgical, laparoscopic, or percutaneous insertion. Designed for optimal inflow/outflow, with biocompatible materials for temporary or permanent access. Material (• Medical-grade biocompatible silicone • Non-toxic, non-pyrogenic, latex-free, DEHP-free •Radiopaque for X-ray visibility)• Straight or curved configuration with double Dacron cuffs • Multiple side holes near tip for optimal dialysate flow • Includes removable/fixed stiffening wire or stylet. Outer Diameter (OD)-3.5–4.5 mm (10–12 Fr).Length - 30–36 cm. Cuff Position- Proximal: 1–2 cm from exit , Distal: 6–8 cm from tip.Two (double cuffed), Straight (preferred). Accessories(• Stylet or stiffening wire • Tunneler • Trocar (if applicable) • Transfer set connector/adaptor • End cap • Sterile pack with user manual)• ETO sterilized or equivalent • Shelf life: Minimum 3 years • SAL: 10⁻⁶. • CE marked / US FDA / CDSCO approved • Manufacturer must be ISO 13485 certified.• Individually sterile-packed • Label must include product code, size, expiry, batch number, manufacturer, sterilization method.• Supplier to provide user training/demo if needed • Certificate of Analysis (CoA) and sterility certificate with each batch • Warranty against manufacturing defects S144.01/C 720 Each Excess(+) Full Conversion INR
42 Vp Shunt (Programmable/ Antibiotic Impregnated) V15.01/C 40 Each Excess(+) Full Conversion INR
200 Important Note: 1. All prospective bidders are requested to quote the rate in BOQ AS PER ACCOUNTING UNIT (AU) REPEAT AS PER ACCOUNTING UNIT (AU) & item specifications as mentioned in the Table-1. WRONG QUOTING OF THE RATE in BOQ will be dealt with as per penal provisions of the T&C of the Tender. 2. Quality of the product supplied, may be ascertained by testing / physical examination by the experts at any stage of the tender period. 3. The equipment should be US FDA/ CE/ BIS/ CDSCO approved (US FDA/ CE requirements will be applicable only when the Indian Standards like BIS/ CDSCO is not available). 4. The prospective Bidders of the said Tender are requested to make a declaration in Affidavit under Annexure VI(b) in case of sole manufacturer/importer (i.e. proprietary in nature). 5. If the Item(s) under sole manufacturer / importer is (are) Proprietary in nature, quarterly intimation is solicited from the approved Bidders positively regarding the status of their Item(s) Proprietary in nature, otherwise their Item(s) will be blocked in the SMIS. 6. In case of Tie Bid, decision will be taken by the TIA as per G.O. No. 2320-F(Y), dated 07.06.2022 issued from Finance Department Audit Branch (Group T).
Total in Figures
Quoted Rate in Figures Select %
Please Enable Macros to View BoQ information
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.14 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.99 MB
Technical_Data_Sheet_385.xls
Tender Documents • 2.75 MB
BOQ_2512776.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .