| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹5.1 LAdmitted-Finance | +5.49% | ₹5.1 L | L1 | Admitted-Finance |
| 2 | L2₹5.2 L+₹5,029.26 (0.99%)Admitted-Finance | +6.53% | ₹5.2 L+₹5,029.26 (0.99%) | L2 | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | - | Not Admitted-Fee/PreQual/Technical Others-Disqualified due to Similar nature of work not attached as per NIT criteria |
Tender Value
₹4.8 L
EMD Value
₹9,672
Closing Date
4 May 2026, 3:30 pmClosed
Superintending Engineer
IWD IIT Kanpur
SITC of high wall fan coil units 7 x 2.0 TR 4 x 1.5 TR capacity with chilled water piping and associated works in MPAES lab at WL 116
2026_IITK_904452_2
02/AC/SE/2026/02
Open Tender
Electrical Works
Percentage
60 days
IIT Kanpur
As per tender
2 documents required · 2 mandatory
₹0
₹9,672
18 May 2026
23 Apr 2026
5 May 2026
23 Apr 2026
4 May 2026
23 Apr 2026
23 Apr 2026 - 30 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled/condenser water piping plumbing i/c fabrication of bends / elbows, tees, reducers etc) inside the building (with necessary clamps, wooden/puff support, vibration isolators, primer/ enamel paint, fittings but excluding valves, strainers, gauges etc.) as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes up to 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. | |||||
| 1.1 | 25 mm | - | Mtr | - | - |
| 1.2 | 32 mm | - | Mtr | - | - |
| 1.3 | 40 mm | - | Mtr | - | - |
| 1.4 | 50 mm | - | Mtr | - | - |
| 2Only Laying /fixing, testing and commissioning of MS Heavy 'C' class pipe ( IS :1239 up 150mm & IS :3589 above 150mm) of following sizes for chilled/ condenser water piping on surface / underground ( including fabrication of bends / elbows, tees, reducers, sockets, unions etc) with wooden / Puff block, masonry support / MS angle-clamp two coats primer/ enamel paint, vibration isolators and fittings as per standard specification complete as required. (Pipe will be provided by the institute free of cost). | |||||
| 2.1 | 25 mm | - | Mtr | - | - |
| 2.2 | 32 mm | - | Mtr | - | - |
| 2.3 | 40 mm | - | Mtr | - | - |
| 3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. | |||||
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
ContractDocuments.pdf
Tender Documents • 0.85 MB
BOQ_952628.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .