| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.7 LAccepted-AOC 36 137 THANGAMAPURIPATTINAM METTUR DAM 636 402 | SALEM | TAMIL NADU | 636402 | ₹11.7 L Quoted ₹10.9 L | L1 | Accepted-AOC L1 |
| 2 | L2₹11.4 LRejected-AOC 30 OPP ALOK PRESS GHATI BADBHUNJA CHAMELI ROAD BHOPAL BHOPAL MADHYA PRADESH 462001 UDYAM MP 10 0044621 | BHOPAL | MADHYA PRADESH | 462001 | ₹11.4 L | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | R K ELECTRICALS L2 | SRI V M A ENTERPRISES L1 |
|---|---|---|---|---|---|
| 1.00 | Charges for Leading the spare UAT from its position to a convenient location in Unit-III transformer yard and back. | 2 | Nos | 25,000 ₹50,000 | 22,150 ₹44,300 |
| 2.00 | Charges for leading 250 MVA/ 15.75 KV / 230 KV, 3 phase GT (Sl.No.6004685) from repair bay-I to Transformer yard-III for 330 mtr.as per data-I | 1 | Nos | 7,55,000 ₹7.5 L | 7,20,700 ₹7.2 L |
| 3.00 | Charges for Transportation of 1 No. filter machines from repair bay- III to Transformer yard-III, and return back to its original position. | 2 | Nos | 26,000 ₹52,000 | 24,620 ₹49,240 |
| 4.00 | Charges for providing three phase power connection and trial run of 1 No. filter machine. | 2 | Nos | 8,540 ₹17,080 | 8,200 ₹16,400 |
| 5.00 | Charges for Transportation of the 40KL oil storage tank from repair bay-II to transformer yard-III & return back to its original position. | 1 | Nos | 30,000 ₹30,000 | 27,120 ₹27,120 |
| 6.00 | Charges for Transportation of the 15KL oil storage tank from Repair bay-II to transformer yard-III & return back to it’s original position. | 1 | Nos | 14,100 ₹14,100 | 13,550 ₹13,550 |
| 7.00 | Charges for transporting of 50 KL new transformer oil barrels from Central Stores to GT-III yard. | 1 | Nos | 36,320 ₹36,320 | 37,790 ₹37,790 |
| 8.00 | Charges for filling of new transformer oil from 330 Nos. barrels in to 40 KL, 15 KL storage tanks, connecting hoses in 40 KL, 15 KL storage tanks, Circulation of oil within storage tanks and shifting of empty barrels to convenient location. (Transformer oil under TNPGCL scope) | 1 | Nos | 51,000 ₹51,000 | 48,890 ₹48,890 |
| 9.00 | Charges for filling of new transformer oil from storage tanks to the transformer main tank, radiator bank and conservator, vacuum pulling, transformer blanketing and hot oil circulation up to reaching parameters to the satisfactory level & Filling of N2 gas. | 1 | Nos | 76,300 ₹76,300 | 73,330 ₹73,330 |
| 10.00 | Charges for painting with 2 coats of Spare GT | 138.37 | sqmtr | 96 ₹13,283.52 | 92.5 ₹12,799.23 |
Tender Value
Refer Docs
EMD Value
₹10,500
Closing Date
16 Dec 2024, 2:00 pmClosed
CHIEF ENGINEER/MTPS-I
CHIEF ENGINEER MTPS-I METTUR DAM
MTPSI ES EMI Leading the 250MVA BHEL make spare generator Transformer Sl.No 6004685 from repair Bay-I to Transformer yard-III- Filling of new transformer oil up to core level as per OEM recommendation and leading and positioning back 16 MVA, HHE make
2024_EB_503919_1
CE-MTPS-I-SE-ES-EM-I-OT 60-2024-25
Open Tender
Electrical Works
45 days
MTPS-I/METTURDAM
AS PER TENDER SPECIFICATION
4 documents required · 4 mandatory
₹0
₹10,500
Yes
14 May 2026
22 Nov 2024
17 Dec 2024
22 Nov 2024
16 Dec 2024
22 Nov 2024
22 Nov 2024 - 16 Dec 2024
Amount
Charges for Leading the spare UAT from its position to a convenient location in Unit-III transformer yard and back.
Charges for leading 250 MVA/ 15.75 KV / 230 KV, 3 phase GT (Sl.No.6004685) from repair bay-I to Transformer yard-III for 330 mtr.as per data-I
Charges for Transportation of 1 No. filter machines from repair bay- III to Transformer yard-III, and return back to its original position.
Charges for providing three phase power connection and trial run of 1 No. filter machine.
Charges for Transportation of the 40KL oil storage tank from repair bay-II to transformer yard-III & return back to its original position.
Charges for Transportation of the 15KL oil storage tank from Repair bay-II to transformer yard-III & return back to it’s original position.
Charges for transporting of 50 KL new transformer oil barrels from Central Stores to GT-III yard.
Charges for filling of new transformer oil from 330 Nos. barrels in to 40 KL, 15 KL storage tanks, connecting hoses in 40 KL, 15 KL storage tanks, Circulation of oil within storage tanks and shifting of empty barrels to convenient location. (Transformer oil under TNPGCL scope)
Charges for filling of new transformer oil from storage tanks to the transformer main tank, radiator bank and conservator, vacuum pulling, transformer blanketing and hot oil circulation up to reaching parameters to the satisfactory level & Filling of N2 gas.
Charges for painting with 2 coats of Spare GT
Charges for providing breather arrangement from main Tank (as per drawing enclosed) including cutting & welding.(Breather pipe line and other materials under TNPGCL scope) (Lumsum)
Replacement of worn out ‘O’ rings, oil seals and Teflon washers , gaskets in Spare GT – (‘O’ rings, gaskets, oil seals and Teflon washers will be supplied by TNPGCL) (Lumsum)
Light Grey enamel paint
Thinner
Consumables (Lumsum)
R K ELECTRICALS (BID ID -1210895)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.76 MB
Tendernotice_2.pdf
PDF • 0.32 MB
BOQ_599270.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid