Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹15.7 L+₹69,480 (4.64%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹18.7 L+₹3.7 L (24.9%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹20.3 L+₹5.3 L (35.3%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹20.5 L+₹5.5 L (36.9%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
11 Sept 2023, 6:00 pmClosed
GE Satwari
GE Satwari Jammu
REPAIR MAINT OF LT PANELS AND ALLIED WORKS AT MH AND RAIPUR SATWARI UNDER AGE E/M OF GE SATWARI
2023_MES_612938_1
GEJM-45/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE Satwari
E Class Cat b i
9 documents required · 9 mandatory
₹500
GE Satwari
₹50,000
Yes
13 Nov 2023
12 Aug 2023
13 Sept 2023
12 Aug 2023
11 Sept 2023
28 Aug 2023
Amount
Dismantling PCC pole all as dirrected and making good surface
M & L for shifting of LT panel/ APFC panel incl necessary PCC foundation wk and necessary electric connection all as specified and directed.
Disconnecting all electric connections, taking down, lifting and transportation of unserviceable APFC panels of any capacity and make to workshop for repair. After repair lifting, transportation to site and making all electric connections all as specified and directed by Engg-in-Charge.
S&F in replacement of standard duty box capacitor with inbult MCB and LED indication of rating 25 KVAR with necessaru electrical connection all as specified and directed.
S&F in replacement of Digital multi functional meter which showing PF, Volts, Amps etc complete. (Make C&S, L&T, ABB)
S&F in replacement of Phase indicating lamps each backed up with suitable MCB including necessary cable connection. (Make C&S, L&T, ABB)
S & F in replacement of 01 KVAR APP based Box Series: LTBCP capacitor bank. (Make - Legrand, C&S, L&T, Havells)
S & F in replacement of 02 KVAR APP based Box Series: LTBCP capacitor bank. (Make - Legrand, C&S, L&T, Havells)
S & F in replacement of 03 KVAR APP based Box Series: LTBCP capacitor bank. (Make - Legrand, C&S, L&T, Havells)
S & F in replacement of 05 KVAR APP based Box Series: LTBCP capacitor bank. (Make - Legrand, C&S, L&T, Havells)
S & F in replacement of 10 KVAR APP based Box Series: LTBCP capacitor bank. (Make - Legrand, C&S, L&T, Havells)
S & F in replacement of 15 KVAR APP based Box Series: LTBCP capacitor bank. (Make - Legrand, C&S, L&T, Havells)
S & F in replacement of MCB 4 pole 32 Amp, 415 V 10 KA 'C' curve Make:- Legrand/ L&T/ Havells/ Indoasian
S&F in replacement of MCCB 3 pole 63-100 Amp, 16 KA fixed type 415 V Make:- Legrand/ L&T/ Havells/ Indoasian
S&F in replacement of MCCB 3 pole 125 Amp, 16 KA fixed type 415 V Make:- Legrand/ L&T/ Havells/ Indoasian
S & F in replacement of MCCB 3 pole 160 Amp, 36 KA Adjustable type 415 V Make:- Legrand/ L&T/ Havells/ Indoasian
S&F in replacement MCCB 3 pole 200 Amp, 36 KA fixed type 415 V Make:- Legrand/ L & T/ Havells/ Indoasian
S & F in replacement MCCB 3 pole 250 Amp, 36 KA Adjustable type 415 V Make:- Legrand/ L&T/ Havells/ Indoasian
S & F in replacement of MCCB 3 pole 320 Amp, 36 KA Adjustable type 415 V Make:- Legrand/ L&T/ Havells/ Indoasian
S & F in replacement of MCCB 3 pole 350 Amp, 36 KA Adjustable type 415 V Make:- Legrand/ L&T/ Havells/ Indoasian
S & F in replacement of MCCB 4 pole 100 Amp, 16 KA Adjustable type 415 V Make:- Legrand/ L&T/ Havells/ Indoasian
S & F in replacement of MCCB 4 pole 160 Amp, 36 KA Adjustable type 415 V Make:- Legrand/ L&T/ Havells/ Indoasian
S & F in replacement of MCCB 4 pole 250 Amp, 36 KA Adjustable type 415 V Make:- Legrand/ L&T/ Havells/ Indoasian
S & F in replacement of MCCB 4 pole 315/320 Amp, 36 KA Adjustable type 415 V Make:- Legrand/ L&T/ Havells/ Indoasian
S & F in replacement of MCCB 4 pole 350 Amp, 36 KA Adjustable type 415 V Make:- Legrand/ L&T/ Havells/ Indoasian
S & F in replacement of MCCB 4 pole 400 Amp, 36 KA Adjustable type 415 V Make:- Legrand/ L&T/ Havells/ Indoasian
S & F in replacement of MCCB 4 pole 500 Amp, 36 KA Adjustable type 415 V Make:- Legrand/ L&T/ Havells/ Indoasian
S & F in replacement of MCCB 4 pole 630 Amp, 50 KA Adjustable type 415 V Make:- Legrand/ L&T/ Havells/ Indoasian
S & F in replacement of MCCB 4 pole 800 Amp, 50 KA Adjustable type 415 V Make:- Legrand/ L&T/ Havells/ Indoasian
Servicing / routine maintenance of ACB of capacity 800 Amp checking of fastener,checking of shock absorber for leakage,checking of top and bottom trip free mechanisam,closing and tripping spring assy & spit pin,spring cut off micro switches.,earth fault relays ,under voltage relays all as specifed. Note: Replacement of any spare part will be measured and paid separately(under items No 34 to 41)
Servicing / routine maintenance of ACB of capacity 1000 Amp checking of fastener,checking of shock absorber for leakage,checking of top and bottom trip free mechanisam,closing and tripping spring assy & spit pin,spring cut off micro switches.,earth fault relays ,under voltage relays Note: Replacement of any spare part will be measured and paid separately(under items No 34 to 41)
Servicing / routine maintenance of ACB of capacity 1250 Amp checking of fastener,checking of shock absorber for leakage,checking of top and bottom trip free mechanisam,closing and tripping spring assy & spit pin,spring cut off micro switches.,earth fault relays ,under voltage relays Note: Replacement of any spare part will be measured and paid separately(under items No 34 to 41)
(a) Supply and fixing of Charging motors 220 V AC
(b) Earth fault relay for 6D-16D/08N-20S of Cat part No is EFR1164P C&S
(c) Closing coil (6D-16D/08N-206(AHA) Cat Part No CS-AVH-C-1 C&S
(d) Shunt Trip 6D-16/08N-20S(AHA) C&S
( e) Single phase polyester resin cast CTs for '' AH/AHA'' ACB for thermal release 8D/08N(AHA) 800/5A
(f) Compact UVT Coil 6D-16D/08N-20S(AHA) Cat part No is CS-AUH-V-A. C&S
(g) Auxiliary switch of type 14 way (7NO+7NC) 6D-16D/08N-20S(AHA) Cat part No is CS-AXH-7A7B-1 C&S
(i) Supply and fixing main moving contacts Assembly
Material and labour for double compression brass cable gland suitable for LT cable of size 25 to 95 sqmm 3.5 core
Material and labour for double compression brass cable gland suitable for LT cable of size 120 to 300 sqmm 3.5 core
Repairs to door shutters of out door/Indoor LT switch board panel,MCCB,s covers,Bus bar chamber covers etc fabricated with MS sheet 3.15mm thick complete including cutting to required size and shape fixing in position by bending, welding all as required for proper functioning of LT panel shutters including two coats of synthetic enamel paint over a coat of red oxide complete all as specified and as directed by the Engineer-in-Charge.
M&L for Painting of Bus bar chamber/ LT panel of any size outdoor pedestal type, factory made, powder coated complete including angle iron frame in all respect all as specified and directed.
M&L for Bus bar chamber of size 750 x 600 x 500 mm outdoor pedestal type, factory made, powder coated made out of 3.15 mm thick CRCA sheet dust and vermin proof complete with openable shutter in front and rear having proper locking arrangement, duly powder coated with 200 Amp 430 V 4 pole MCCB as incommer control and including 400 Amps, 4 pole Aluminium bus bar mounted on insulator, suitable for 3 phase, 415 volts, 50 Hz AC supply including control wiring to panel with suitable size of PVC insulated and sheathed copper cable, duly mounted on angle iron frame 50x50x6 mm including necessary PCC foundation work in all respect with phase indicator lamps (R, Y. B) – 01 Set. all as specified.
Supplying, installation, commissioning and testing of LT switch gear control panel board 440 volt AC 3 phase 4 wire for Indoor type installation "KIOSK TYPE" fabricated out of steel sections i.e CRCA sheet 3.15 mm thick , angle / channel and flat iron sections of suitable size with opening on front, and back door in two halves fitted with handle and bolts for pad lock. The panel door shutters fixed with stainless steel hinges, heavy duty and with door stoppers. The door opening shall not be less than 150 degree. The construction of panel board shall be dust, vermin proof, IP 54 standard, with phosphatised powder coating painting externally and internally to protect against corrosion: The panel shall be mounted on suitable size of channel section having ground clearance 60cms from grouting bolts, complete duly incorporated with following accessories: - (a) Bus bar chamber with electrolytic grade aluminum strip with heat shrikable sleeves with colour code supported on epoxy resin based insulators 4 strip of suitable length for current rating 400 amps
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with tope edge of the plate not less than 1.5 metres below normal ground level, connected to galvanized earth lead iron wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, GI light grade protection pipe 15mm dia, GI medium grade water pipe 20mm dia with funnel all as shown in electric plate No. 5 of SSR-1991 pt-I and testing complete including earth work in any type of soil PCC 1:2:4 as in earthing pit CI pit cover 5.5mm thick common salt charcoal all as specified.
M & L for earthing with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25M deep below ground level with top edge of the plate not less than 1.5M below normal ground level connected to galvanised strip 32x6mm by means of nuts, bolts, checknuts, washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part I connected to earthing test point including excavation/ earth work in any strata removal of surplus earth, GI pipe for watering and funnel, PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 in cover slab with 40mm dia light grade GI protection pipe and 20mm dia light grade GI pipe for watering all as specified and directed by Eng-in-charge.
M & L for cable jointing kit Indoor/outdoor type, heat shrinkable type including all jointing material & accessories suitable for 1100 Volt grade aluminium conductor cables of size 10 to 16 Sqmm 4/3.5 core cables all as directed and specified.
-ditto- but suitable for 25 Sqmm and upto 35 Sqmm x 4/3.5 core
-ditto- but suitable for 50 Sqmm x 3.5 core
-ditto- but suitable for 95 Sqmm x 3.5 core
-ditto- but suitable for 120 Sqmm and upto 185 Sqmm 3.5 core
-ditto- but suitable for 240 sq mm x 3.5 core
Supply & fixing in replacement of Off Load change over switch 415V AC, 4 pole, 50 Hz front openable type in sheet steel enclosure including fixing arrangements in existing panel/on wall, including provision of thimble, nut bolts etc of required capacity and of following cap:- (Make C&S/L&T/Havells/Indo-asian) (a). Change over switch 63 Amp
(b). Change over switch 100 Amp
(c). Change over switch 200 Amp
(d). Change over switch 250Amp
Supply & fixing in replacement of onload change over switch 415V AC, 4 pole front openable type in sheet steel enclosure including fixing arrangements in existing panel/on wall, including provision of thimble, nut bolts etc of required capacity and of following cap:- (Make C&S/L&T/Havells/Indo-asian) (a). Change over switch 63 Amp
(b). Change over switch 100 Amp
(c). Change over switch 160 Amp
(d). Change over switch 200 Amp
Supply and fixing of spreaders 4 pole 100 To 250 Amps fixing in MCCB of any make and models all as directed by Engr In Charge.
M/S RAJ ENGINEERS
vivek and co
Harsh Electricals
G C BUILDERS
M/S S K Electricals Regd
G M ENGINEERING SERVICES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .