EXECUTIVE ENGINEER UIT BHILWARA
EXECUTIVE ENGINEER UIT BHILWARA
Repair and maintenance work for street lights installed in the Trusts planned and non-planned areas on the western side of the railway line (ARC).
2026_UITBH_603996_2
NIT-19/2026-27 UIT BHILWARA
Open Tender
Electrical and Maintenance Works
Percentage
365 days
BHILWARA
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Secretary UIT, Bhilwara/MD RISL Jaipur
₹1.3 L
Yes
14 Oct 2026
14 Oct 2026
27 Oct 2026
14 Oct 2026
26 Oct 2026
14 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Maintain power supply (underground and overhead) from AVVNL energy meter to auto on off pannel to feeder. piller to pee/tubular pole to led ligt. Repair, Rectification, Replacement of defective component of the Existing Led light or entire led light if required so to run led light system. Replacement of old led light with new led light if led found broken/damage/stolen. Replacement of damage or burnt cab(e/overhead line/fuse box with new cable/overhead line/fuse box from from AVVNL energy meter to auto on off pannel to feeder piller to pcc/tubular pole junction in supervision of engineer for this work payment shall be extra . Repair of damage cable and overhead line from AVVNL energy meter to auto on off pannel to feeder pilfer to pee/tubular pole. Replacement and repair of damage /burnt /stolen cable, wire or jumper from junction box to-light and pee pole to light(20 watt/30/45/72/80/90/120/160/200 watts) on PCC/ Tubular poles with material including replacement of service wire, spd , driver, and LED etc (all related accesorries) (7585 Nos.*12 Months =91020 ) | 91,020 | Each | 54 | ₹49,15,080 |
| 2 | Regular operation and maintainance and repair of Timer and Contactor, MCB, Wires and all related items in Electrical Panel. Also maintainence of electrical system from Panel to LED light including overhead line and underground line. ( 101 Nos.*12 Months = 1212 ) | 1,212 | Each | 150 | ₹1,81,800 |
| 3Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | |||||
| 3.1 | 4 core*10 sqmm | 700 | mtr. | 192 | ₹1,34,400 |
| 3.2 | 3.5 core*25 sqm | 100 | mtr. | 256 | ₹25,600 |
| 4 | Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade direct in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) , with procedure as per following points:- (a) Make a river sand bed of height 125 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth | 700 | mtr. | 185 | ₹1,29,500 |
| 5Providing and fixing of IP 65 protected Polycarbonate / Polysterene fuse box moulded with inside knock outs of following size with hinged cover, transparent window, PU gasket, locking arrangement, duly holded with 2 nos. pole clamps of 20 mm x 3 mm flat with nut and bolts, The box shall be provided with Din rail, 4 / 8 way 10.0 / 16.0 sq.mm heavy duty connector, earth terminal, complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | |||||
| 5.1 | 125 mm X 200 mm X 122 mm | 80 | EACH | 1,827 | ₹1,46,160 |
| 6P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class 750 N, Externally corrugated and having smooth surface inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accrediated is to be submitted.(Excavation of Earth & Back filling with compaction is to be Paid Extra)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | |||||
| 6.1 | 50 mm | 800 | mtr. | 85 | ₹68,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.43 MB
Tendernotice_2.pdf
PDF • 0.48 MB
Tendernotice_3.pdf
PDF • 3.93 MB
Tendernotice_4.pdf
PDF • 0.66 MB
Tendernotice_5.pdf
PDF • 0.14 MB
Tendernotice_6.pdf
PDF • 2.25 MB
02-Condition.pdf
Tender Documents • 4.31 MB
BOQ_1071293.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .