Loading…
Loading…
Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical GAJANAN SOCIETY BALAPUR ROAD SHEGAON DIST BULDHANA | SHEGAON | BULDHANA | MAHARASHTRA | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
Tender Value
₹11.2 L
EMD Value
₹11,183
Closing Date
16 Mar 2026, 11:00 amClosed
EE RWS
zp kolhapur
PROVIDING 25KVA POLE MOUNTED DISTRIBUTION TRANSFORMER WITH H.T. OVERHEAD LINE FOR H.P, 1 NO. 3 PHASE POWER SUPPLY TO PWW G NO/M.No. AT VILLAGAE SHIVANGE TAL CHANDGAD DIST KOLAHPUR
2026_KOLHA_1283124_1
48/2025-26
Open Tender
Electrical Works
Percentage
180 days
KOLHAPUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
₹11,183
Yes
10 Mar 2026
2 Mar 2026
16 Mar 2026
2 Mar 2026
16 Mar 2026
2 Mar 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB (Convert 3 pole MCCB in to 4 pole MCCB as per Note below Item No.5-5-6 Note No.1) | 1 | Each | 6,689.34 | ₹6,689.34 |
| 2 | Supplying and erecting porcelain base iron clad cut out HC type 415V, 63A erected on polished wooden block. | 3 | Each | 400.05 | ₹1,200.15 |
| 3 | Supplying & erecting 415V, 32A porcelain base neutral link complete erected in provided M.S. box. | 1 | Each | 89.25 | ₹89.25 |
| 4 | Supplying and erecting plywood 12 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners supports, nuts bolts etc. complete. (0.4572X0.6096 = 0.278 SQ.Mtr plywood to fix DTC Mteter in CRCA sheet box Such 1 box So 0.278x1Nos.=0.278 sq.mtr.) | 0.28 | m2 | 834.75 | ₹232.06 |
| 5 | Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. For D.P structure of 25 KVA T/F (1) Channel 100X50X5mm Weight 9.2 Kgs./mtr. 2 Nos for A.B switch, 2 Nos for T/F base of length 2.8 Mtrs. Total length 2.8mtrs.x4 Nos.=11.20mtrs. So 11.20mtrs.x9.2Kgs.=103.04Kgs.(2) Channel 75x40 weight 6.8Kgs/mtr. 1 No for D.O fuse and 1 No for L.A Total length 2.8Mtrs+2.8Mtrs.= 5.60Mtrs. So 5.60Mtrs.X 6.8Kgs.=38.08Kgs. (3) Angle 50x50x6mm. weight 4.5Kg/mtr. 2 Nos. for D.B, length 2.8Mtrs.2.8mtrs.x2Nos.=5.60Mtrs. So 5.60Mtrs.x4.5Kgs.= 25.20Kgs. (4) For T/F belting, angle 50x50x6mm, length 2.8Mtrs.=2X2.80Mtrs. weight 5.6Mtrs.x4.5Kgs.=25.20Kgs..x(5) 14 SWG CRCA sheet for Dist. Box, 4.5 sq.mtrs. Weight 15.70Kgs./Sq.Mtr. So 4.5sq.mtrs.x15.70Kgs.=70.65Kgs. (6) On pole No.'0' channel 100x50, length 1.6 Mtrs. @9.2Kgs/mtr. So weight 1.6mtr.x9.2Kgs=14.72 Kgs.(7) stud angle 50x50x6 length 1.5mtrs.x2Nos. i.e 3 mtrs. in length So weight 3mtrs. @4.5Kg/mtrs. 3mtrs.x4.5Kgs.=13.50Kgs. 4 sq.mtrs.x15.70Kgs.=62.80Kgs. Total Weight 103.04Kgs+38.08Kgs.+25.20Kgs.+25.20Kgs.+70.65 Kgs. +13.50Kgs+14.72Kgs.=345.19 Kgs. | 345.19 | kg | 195.3 | ₹67,415.61 |
| 6 | Supplying and erecting LT CT multifunction DLMS compliance energy meter of accuracy of class 0.5 , 3x240V,50 Hz with optical & RS 232 port, backlit LCD, measure & display trivector energy, load survey, TOD, tamper detection & logging, power ON /OFF events, instantaneous parameters of rating 1/5 A with display in absence of power complete with zero adjustment & test certificate from manufacturer erected on provided M.S. box and connected to CTs. | 1 | Each | 11,267.55 | ₹11,267.55 |
| 7 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL | 30 | Mtr. | 221.55 | ₹6,646.5 |
| 8 | Supplying and erecting rolled steel joist (girder) pole 100 x 116 mm (23 kg/m) with base plate in provided foundation as per specification no. OH-PL/RSJ ( For 25 KVA T/F 10mtrs.x2poles=0 mtrs. +For H.T line 9 Mtrs. Hight, 02 pole i.e 9mtrs.x2 Nos = 18 mtrs&10mtrs 2pole i.e.10x2=00. and 8mtrs. 4Nos stud pole i,e 8mtr.x4Nos=00mtrs.11mtrs 2 pole i.e.11x10=110 Total ( 00Mtrs.+ 18mtr+000mtrs+00 Mtrs+110.= 138 Mtrs.) | 138 | Mtr. | 1,740.9 | ₹2,40,244.2 |
| 9 | Supplying and erecting V cross arm with ISM channel of 75x40x6mm for 11kV HT OH line with arrangement to fix insulator at 45mm from the end & horizontal distance between insulators 1220mm bent at angle of 60 degree keeping base 305mm and the total vertical height of V cross arm as 460mm, and fixed on pole with MS clamp of 80x10 mm, nut bolts, washers complete as per specification no. OH-PL/VCA | 10 | Each | 1,281 | ₹12,810 |
| 10 | Supplying and erecting 75x40 x6mm with 4.4mm thick web and 7.3mm thick flange channel (top pin) with clamp of suitable length so as to maintain vertical clearance of 1065mm for 11kV, 1320mm for 22kV between insulators for erection of top pin insulators complete as per specification no. OH-PL/VCA | 20 | Each | 601.65 | ₹12,033 |
stage.html
html • 0.02 MB
tech_bid_open.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.55 MB
NIT.pdf
Tender Documents • 1.53 MB
SBD.pdf
Other Document • 2.28 MB
BOQ_2206830.xls
BOQ • 0.37 MB
Corrigendum_13032026.pdf
PDF • 0.03 MB
Corrigendum_09032026.pdf
PDF • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .