Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹11.4 LAccepted-AOC SHOP NO 107 MOHAN SINGH PLACE NEW DELHI 110001 | NEW DELHI | DELHI | 110001 | ₹11.4 L | 1 | Accepted-AOC L-1 |
| 2 | 2₹11.9 LRejected-Finance UC I USHA PARK HARI NAGAR NEW DELHI 64 | NEW DELHI | DELHI | 110001 | ₹11.9 L | 2 | Rejected-Finance 2 |
| Sl No | Description | Qty | Unit | SRI BALAJI ELECTRICALS L2 | Aviadu energy and infra pvt ltd L1 |
|---|---|---|---|---|---|
| 1.00PART A - DSR Items | |||||
| 1.00 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm | 210 | metre | 84 ₹17,640 | 95 ₹19,950 |
| 1.00 | 2.12.2:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps | 2 | each | 536 ₹1,072 | 525 ₹1,050 |
| 1.00 | 2.14.3:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps | 1 | each | 2,774 ₹2,774 | 2,722 ₹2,722 |
| 1.00 | 5.1:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. | 10 | set | 5,474 ₹54,740 | 5,440 ₹54,400 |
| 1.00 | 5.18:Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. | 1,630 | metre | 34 ₹55,420 | 28 ₹45,640 |
| 1.01 | 7.6.1:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of
following size in the existing masonry open duct as required.Upto 35 sq. mm | 1,540 | metre | 22 ₹33,880 | 9 ₹13,860 |
| 1.01 | 11.1.3:Erection of RCC/ PCC pole of following length in brick ballast and ramming the foundation,
finishing with 150mm thick cement concrete (1:3:6) layer on top with including excavation and refilling etc as required.Above 8.0 metre and upto 11.0 metre | 45 | each | 7,558 ₹3.4 L | 7,550 ₹3.4 L |
| 1.01 | 12.1:Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm ), 7/ 4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required. | 4 | no | 5,668 ₹22,672 | 5,700 ₹22,800 |
| 1.01 | 12.13:Supplying and erection of galvanised 'D' iron clamps complete with shackle insulator (75 mm X 90 mm),G. I. bolts, nuts and washers, coach screws etc. as required. | 70 | set | 268 ₹18,760 | 270 ₹18,900 |
Tender Value
₹12.4 L
EMD Value
₹24,898
Closing Date
14 Mar 2024, 3:00 pmClosed
Executive Engineer-NZ
Office of the Executive Engineer,EE(Elec-I) Division, NZ
Installation of Street Lights at Phirni Road and Sirja Roads of Punjabkhore Village in Ward No.31 under Narela Zone.
2024_MCD_190416_1
MCD/TR/3121/2024_6_1_1/1
Open Tender
Electrical Works
120 days
Narela, NANGAL THAKRAN
4 documents required · 4 mandatory
₹590
₹24,898
17 Jun 2026
8 Mar 2024
14 Mar 2024
8 Mar 2024
14 Mar 2024
8 Mar 2024
Amount
PART A - DSR Items
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
2.12.2:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.14.3:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
5.1:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
5.18:Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
7.6.1:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm
11.1.3:Erection of RCC/ PCC pole of following length in brick ballast and ramming the foundation, finishing with 150mm thick cement concrete (1:3:6) layer on top with including excavation and refilling etc as required.Above 8.0 metre and upto 11.0 metre
12.1:Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm ), 7/ 4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
12.13:Supplying and erection of galvanised 'D' iron clamps complete with shackle insulator (75 mm X 90 mm),G. I. bolts, nuts and washers, coach screws etc. as required.
PART B - Approved Items
122.1.38:Supply of XLPE insulated PVC sheathed Al. Conductor Un-Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*16 sqmm
122.2.2: P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd. as reqd.
122.2.33:SITC of 60W LED Street Light luminaire fitted with lens, top opening driver cover made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =60 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
122.2.190:Supply and fixing of 32mm dia X 1 meter long G.I. Pipe (Medium Class) bracket for mounting of fluorescent/HPMV/HPSV Street Light fitting on pole including bending the pipe to the required shape , 2 nos 25mm X 6mm flat iron clamps with nuts, bolts and washer , painting the flat iron with primer and finish paint etc. as reqd.
OD29741/2023-2024:Supply of 9M Pre cast RCC Pole (PCC Pole)
SRI BALAJI ELECTRICALS
Bidder Name
SRI BALAJI ELECTRICALS
Aviadu energy and infra pvt ltd
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid