| 1 | L1₹25.7 LAccepted-AOC MALLICK JAYANTI BAGAN KUMAR BAGAN JHAPPUKUR POST SAHAGANJ DIST HOOGHLY HOOGHLY 712103 | HOOGHLY | HOOGHLY | WEST BENGAL | 712103 | L1 | Accepted-AOC LOWEST RATE QUOTED | |
| 2 | L2₹26.6 L+₹90,226.75 (3.51%)Rejected-Finance VILL P O TINNA P S PANDUA DIST HOOGHLY PIN 712149 | PANDUA | HOOGHLY | WEST BENGAL | 712149 | L2 | Rejected-Finance highest rate quoted | |
| 3 | L3₹27.3 L+₹1.6 L (6.23%)Rejected-Finance 55 1 CHARAKDANGA NATUNPUKUR ROAD BARASAT KOLKATA 700124 | KOLKATA | KOLKATA | WEST BENGAL | 700124 | L3 | Rejected-Finance highest rate quoted | |
| 4 | L4₹29.0 L+₹3.3 L (12.7%)Rejected-Finance 6 1 SERANG LANE KOLKATA 700014 BARASAT NORTH 24 PARGANAS | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700014 | L4 | Rejected-Finance highest rate quoted |
Tender Value
Refer Docs
EMD Value
₹55,000
Closing Date
18 Nov 2022, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive_Engineer_PWD_Hooghly_Electrical_Division
Office of The Executive Engineer, PWD, Hooghly Electrical Division , Purta Bhavan 3rd Floor , Sarat Sarani , Kodalia , Hooghly.
Restoration and renovation of the existing damaged defunct street lighting arrangement incl. improvement of illumination level over Ishwar Gupta Setu and allied Electrical Installation works.
2022_WBPWD_418847_1
WBPWD/EE/ HED / NIeT-14/3rdcall2022-23
Open Tender
Electrical Work/ Equipment
Item Rate
60 days
HOOGHLY
Please refer Tender documents.
3 documents required · 3 mandatory
₹55,000
HOOGHLY ELECTRICAL DIVISION
21 Dec 2022
2 Nov 2022
21 Nov 2022
2 Nov 2022
18 Nov 2022
2 Nov 2022
7 Nov 2022
Amount
Dismantling steel tubular/Rail/Strut embedded in CC foundation incl. excavation, filling of holes, restoring surface, loading at site and delivering, unloading, sorting, stacking properly at any place as per direction upto a lead of 1.6 km for re- arrangement Errection. [14 / I-2 ]
Supply & Delivery of 8 Mtr swan neck type GI Steel Tubular Pole [weight:- 83kg (approx.)] & having dimension are : outside dia & thickness of the Bottom section (114.3x4.5) mm; Middle section-(88 .9x4.05) mm, Top Section- (76.1x 3. 25 ) mm, Length of bottom and middle section of pole are 4.50Mtr and 1.75Mtr respectively. Effective overhang : 1.5 Mts, Tilt Angle : Five degree with fixing the base plate and GI earth bolt after making drilled holes etc. on pole as per direction of EIC [Make : Bajaj / Transrail/ Utkarsh/ Calcutta Pole.].
Supply & Delivery of MS 9 Mtr Steel Tubular Pole (steel mk Zindal/Bansal) pole manufacturer [Make : Bajaj / Transrail/ Utkarsh/ Calcutta Pole.] as per specification Type 410 SP -28 as overall length 9 mtr weight 113kg. & having dimension are : Out side dia & thickness of the Bottom section ( 13 9. 7x4 .5 0) mm; Middle;(11 4. 3x3 .6 5) mm ,Top Section (88 .9x 3. 25 ) mm with fixing the base plate and GI earth bolt after making drilled holes etc. on pole as per direction of EIC
Erection of swan neck type GI pole is required to be executed by following arrangements as per direction of EIC and as per actual site requirement. i) The GI pole is to be inserted inside the exsisting RCC pockets in crash barrier of the bridge by using necessary tools and tackles. The remaining portion of hole is to be filled with Ordinary cement concrete (mix 1:1.5:3) with graded stone chips (20 mm size) after inserting the pole in the hole. ii) A MS plate of length-300mm, breadth-300mm, thickness-12mm, PCD-250mm, having a central cutout of diameter 118 cm in it and four no of holes of dia 20mm at suitable points. The MS plate is to be welded around the pole at approximately 1mtr from pole base at site after pole erection and strengthened with 4 nos. stiffner by welding method as per direction of EIC. iii) Supply & fixing of 4 nos. foundation bolt [Make of foundation bolt : Bajaj / Transrail/ Utkarsh/ Skipper or equivalent make as approved by EIC] of 16mm dia and 300mm length is to be done by rebar anchoring process by using ETA approved for sesimic criteria in rebar connection, Including drilling hole to the required depth by rotary hammer drill,cleaning with brush & jet of clean air, filllng resin and hardener using serrated nozzle to eliminate mixing error and In a voldlessmanner Including supplying and application of chemical for rebar anchoring and chargesfor all tools & plants. iv) Installation of the above pole over foundation bolt and fixing with nuts, washer etc. is to be done as per direction of EIC using necessary tools and tackles.
Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts.above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly (ON ROAD)
Upto 9.0 mtr. Size 0.6x0.6x1.70 mts [1 (a)/ H- 1 ]
Extra on items above, for providing CC (6:3:1) base block (around the pole) dimension 0.60x0.60x0.76 mt. above ground level, as per GS [3 (b)(i)/ H- 1 ] (ON ROAD)
Supply & Fixing of 240V, 150 W LED, Street light luminarie with IP66 Protection, having inbuilt tilting angle arrangement (Make- Crompton Cat no. LSTN1-150-WW-A, with CKT-3000K, Magik- 150W, cat no SRBL with 120Lm/Watt or Wipro- 150W, cat no LRO2-182-xxx57-G2 with 120Lm/Watt or Phillips 150W, cat no BPR 340LED 175CW HOSLC with 120Lm/Watt equivalent make/model of Phili-ps/Bajaj/Wipro/Havells or equivalent make/model as approved by E.I.C) on ST Pole as per direction of E.I.C. The luminaries to have five years warranty and report to be submitted during execution of work.
Supply and laying of of flexible 3 core 1.5 Sqmm Cu cable [ Make- Finolex / Gloster/KEI/Havells] from loop box to fittings as per direction of EIC.
Supply of 4/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Nicco / Gloster/KEI/Havells as approved by E.I.C]
4 Core 16 Sq. mm
Laying of cable after cutting floor/pavement/ wall as per GS for the following Sizes.
2.5 to 35 Sq. mm [ 5(i)/ F- 3 ]
Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
2.5 to 35 Sq. mm [ 2(b)/ F- 1 ]
Laying of cable in underground trench as per GS for the following numbers of Cables.
Upto 35 Sq. mm [ 1(a)/ F- 2 ]
Laying of cable upto 150 sqmm through existing covered masonary trench incl. taking out RC covers, setting them in order, mending good damages filling the trench with fine dry sand incl. Supplying sand as per GS. [ 4(a)/ F- 3 ]
Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4 core
Upto 35 Sq. mm [ 1(a)/ F- 2 ]
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS.
4Core 16 Sq. mm [7(c)/F4 & 8(b- xiii) /F5]
S & F solderless Copper socket by crimping of Copper wires. a)1.5 sq mm
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings as per GS
40mm dia [11(d)/F-6]
Supply and laying of 40mm dia 3mm thick Polythene Pipe for cable and covering with exsisting cement concrete to hide with bridge structure for cable laying where existing cable has to be replaced with newer one, by opening the masking cement covering, and submitting the cables to PWD office .
Supply and fixing of swing damper for the above pole bracket, light assembly, as per direction of EIC, suitable for the specified LED Fittings and poles, bracket assembly.
S&F 50 mm. dia 1.5 mtr. long detachable type G.I. Single arm bracket, suitable for pole head. The arm bracket shall be properly welded with 15 mm. thick stifner plate of pole sleeve for strengthening incl. properly fixing arrangement with the pole by bolts, nuts and washer as per direction of EIC.
S/F of cast iron loop box with hinged door arrangement having locking with allenkey and cast iron cover of 200 x 250 x 100 dimension, and with one no (6-32A) SPMCB, one 63A 4 terminal STUD with stainless steel bolts, nuts, washers complete within foundation as per direction of EIC.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level [ By TATA-Medium GI pipe] [2(a)/G-1].
Excavation of soil for installation of Earth Electrode and filling & ramming. (For Soft Soil) [1(a)/G-1]
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement mortar (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [3(a)/G-2]
Supply & Fixing 7/10 SWG GI (Hot Dip) stranded wire for Horizontal run on the parapet/roof/wall with GI saddles spaced not exceeding 1100 mm apart incl. mending good the damages to building works Mtr [ 10 / J-1 ]
Supply of Aluminium Alloy Tiltable Tower Extension Trolly Ladder,(40 ft) square type Ladder made out of extruded, tested Quality ALUMINIUM LADDER Sections with alloys temper 6351(T)6 with steps made of Aluminium fluited pipes of 25mm (1”) dia approx. at a distance of 12” (300 mm) complete with a set of specially designed Rope pulleys and winch arrangements with suitable size steel wire rope for extending and closing the extended section of ladder to any required height fabricated on M.S. channel frames and Four M.S. Forged Solid Rubber Casted Special Wheels. Two no. winches will be provided onefor Extended purposes another for Tilting purpose. The Winch Gear of the Ladder are Provided with Locking Arrangement. The Platform of size 2‟ X 2‟ on the top guarded from three sides will be provided for safeworking. It should be with anchoring arrangement, with 4 nos anchoring and pulling arrangement for transportation, complete in all respect.
Design, Manufacture, testing, supply and commissioning of the following outdoor type Distribution Feeder Pillar box conforming to Indian Standard IS : 5039-1969 with latest amendments a. Suitable for use on 3 phase 4 wire, 400/440 Volts 50 Cycles A.C. Supply and shall be suitable for short circuit fault of 31 MVA at 415 Volts b. The dimension of the body is --1500 (H) X 1200 (W) X 550 (D) mm c.The body will be fabricated with 5mm thick MS plate, MS angle( 50X50X6 mm) & MS Flat ( 50X6 mm) d.The Base Plate will be made by 10 mm thick MS Plate e.The top of the box will be fitted with a sloping canopy made out of 5 mm thick sheet steel. f. It will have a set of water proof double hinged door at the front with suitable locking arrangement ( Godrej Type ) and provision for manual locking arrangement
g. Adequate ventilation by means of louvers with wire mesh shall be provided on both sides and at the top and bottom of both sides of LT pillars h. The inside will be painted by 1 coat of Redled / zinc chromate and the outside will be painted by 2 coats of synthetic enamel paint over 1 coat of Redled / zinc chromate. i. A hylam sheet of 10mm thick of suitable size will be fitted. j. The Enclosure shall provide Degree of protection IP -43 in accordance with IS : 2147 -1962 with its latest ammendment.
The Feeder box will contain the following switches and accessories - 1) S & F of 63A front operated SFU with 3 nos HRC fuse, complete fixed inside feeder piller box / room as per GS. [4(a)/D-3] - 1 No.
2) S & F 3 phase timer box Made of 14 SWG MS sheet (size approx– 400 X 350 X 175mm) with powder coated synthetic paint incl. hinged type MS door , inter locking system consisting the following materials : a) S & F 24 Hr. timer (L & T , J648B1/Legrand) – 1 no. b) S & F 440 Volt 32A (AC-3) 3P contactor (L & T, ML –2 , SS90701) – 1 no. c) 6 amp auto manual toggle switch – 1 no. (L &T) d) Indicating lamp B & G (L&T) – 2 nos. e) 440V, 32A, 10KA, C Series 4P MCB (legrand)on din rail for incoming-1no f) 100A capacity 4W Brass stud type connector on FRP chair for I/C & O/G- 2 nos. All control circuit wiring would be made by 1x1.5 sqmm stranded Cu wire(FRLS) and the I/G & O/G circuit with 1x10 sqmm copper wire maintaining colour code incl taping, socketing to complete the work. The box should be fixed inside the fedder pillar with suitable size of flush nut and necy. Connection as per direction of E.I.C. - 1 No.
3) (i) Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall as per GS( Make - Legrand ) 4 Way ( Up to 160 A ) Make - Legrand, Enclosure 607914 [15 / D- 11 ] (ii) Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connections per GS [ Make -Legrand ] (a) 32 A TP - 3 Nos. [ 7 / D- 6 ] (b) 16 A SP - 3 Nos. [ 7 / D- 6 ] (iii) Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA in existing Vertical DBs including necessary connection as per GS [ Make - Legrand ]. 63 A FP [10/ D- 8 ]
4) S&F Kit-Kat Rewirable (Porcelain Fuse carrier & Base) of 415 V 100A (Set of 3 nos.) [ Make - Havells/Anchor or equivalent make as approved by E.I.C]
Interconnection of the all I/C and O/G switches are to made with suitable size tinned copper bar with proper insulation with coloured sleeving as per direction of EIC
Installation of the above pillar box with brick foundation of size 1700 x1300 x 600mm with hard jhama cement morter soaling at bottom 300mm below GL & 450mm above GL neatly plastered & neat cemented finish incl. painting by best quality 2 coats of synthetic enamel paint over 1 coat of RO primer as per direction of the EIC.
2) S & F 3 phase timer box Made of 14 SWG MS sheet (size approx– 400 X 350 X 175mm) with powder coated synthetic paint incl. hinged type MS door , inter locking system consisting the following materials : 1) S & F 24 Hr.ASTRO timer (L & T , AUTS02AST00/Legrand) – 1 no. 2) S & F 440 Volt 32A (AC-3) 3P contactor (L & T, ML –2 , SS90701) – 1 no. 3) 6 amp auto manual toggle switch – 1 no. (L &T) 4) Indicating lamp B & G (L&T) – 2 nos. 5) 440V, 32A, 10KA, C Series 4P MCB (legrand)on din rail for incoming-1no 6) 63A capacity 4W Brass stud type connector on FRP chair for I/C & O/G- 2 nos. All control circuit wiring would be made by 1x1.5 sqmm stranded Cu wire(FRLS) and the I/G & O/G circuit with 1x10 sqmm copper wire maintaining colour code incl taping, socketing to complete the work. The box should be fixed inside the fidder piller with suitable size of flush nut and necy. Connection as per direction of E.I.C.
Ordinary cement concrete (mix 1:1.5:3) withgraded stone chips (20 mm size) including shuttering and reinforcement, if any, in ground floor as per relevant IS codes ( Pakur variety ) [Page 26, item no.10 of PWD Schedule for Building works with latest ammendment]
Add GST @12% Rs.
Add LWC @1% except item no.-2,3,9 & 26:- Rs.
ROYAL ENGINEERS CO-OPERATIVE SOCIETY LTD
CHANDA CONSTRUCTION
SHATABDI ENGINEERING AND CONSULTANCY
technical_826316.pdf
PDF • 0.60 MB
techsummary_826316.pdf
PDF • 0.60 MB
BOQ Comparative Chart
xlsx • 0.02 MB
finsummary_826316.pdf
PDF • 0.53 MB
NIT14-22-23.pdf
PDF • 0.09 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .