Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.8 LAccepted-AOC WARD NO 02 LAKHUWALI PO THE PILIBANGAN DISTT HANUMANGARH RAJASTHAN 335803 | HANUMANGARH | RAJASTHAN | 335803 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹28.1 L+₹2.3 L (8.72%)Rejected-Finance | L2 | Rejected-Finance Rejected in AOC | |
| 3 | L3₹29.7 L+₹3.8 L (14.8%)Rejected-Finance | L3 | Rejected-Finance Rejected in AOC | |
| 4 | L4₹30.6 L+₹4.7 L (18.4%)Rejected-Finance NEW ABADI KISHANPURA SURATGARH 335804 DISTT SRIGANGANGAR RAJ | GANGANAGAR | RAJASTHAN | 335804 | L4 | Rejected-Finance Rejected in AOC | |
| 5 | L5₹33.4 L+₹7.6 L (29.3%)Rejected-Finance BHAGAT SINGH CHOWK SURATGARH 335804 DISTT SRIGANGANAGAR RAJ | GANGANAGAR | RAJASTHAN | 335804 | L5 | Rejected-Finance Rejected in AOC |
Tender Value
₹37 L
EMD Value
₹74,000
Closing Date
29 Oct 2021, 6:00 pmClosed
GE ARMY SURATGARH
SURATGARH MIL STN
Special repair to Bldg No P-20, P-26, Provision of of Air conditioning system, false ceiling and sewage line connection for disposal of waste water under AGE B/R-II at Suratgarh Mil Stn
2021_MES_478425_1
GE (A) SOG - 43/21-22
Open Tender
Civil Works
Item Rate
180 days
SURATGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE ARMY SURATGARH
₹74,000
Yes
17 Dec 2021
28 Sept 2021
1 Nov 2021
28 Sept 2021
29 Oct 2021
12 Oct 2021
Amount
Demolition of plain cement concrete in ground floor and pavings not exc 15 cm thick (below or above ground level) including floor tiles of any description complete all as specified and directed by Engineer-in-charge.
Demolition of brick work, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-charge.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for ( reinforcement cut as required to facilitate demolition) complete all as specified and directed by Engineer-in-charge.
Dismantling bricks (laid flat or on edge) or brick tiles on roof terrace, in floors, channels, kerbs, aprons etc laid dry or laid dry and pointed and removing from site complete all as specified & directed by Engineer-in-charge.
Dismantling of timber scantling 40 sqcm and over in section unframed work and in any position complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster or cement lime plaster on stone surface/brick surfaces of walls including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed by Engineer-in-charge.
Taking down steel rolling shutters area exc 10 sqm but not exc 25 sqm each including all fitting and fixtures complete all as specified and directed by Engineer-in-charge.
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth, or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable and water supply / sewage pipe line etc. in soft / loose soil & getting out including taking out old brick or precast cable cover complete all as specified and directed by Engineer-in-Charge.
All as per serial item No. 8 here-in-above but depth exc 1.5 mtr & not exc 3mtr
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep in soft/ loose soil and getting out complete all as specified and directed by Engineer-in-Charge.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer-in-Charge.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc. complete all as specified and directed by Engineer-in-charge.
Supply only integral water proofing compound (ISI marked) complete all as specified and directed by Engineer-in-charge.
M&L for hardcore of broken stone / boulders gauge not exc. 63mm, deposited, spread and leveled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-charge.
M&L plain cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as in copings, kneelers, brackets, benching for manholes etc including chamfers, weathering, slightly rounded or chemfered roof kerb at the junction and parapet or other vertical surface etc, including neccessary form work complete all as specified and directed by Engineer-in-Charge.
M&L for pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate as in landing, cover slab for manholes, septic tanks, soakage wells, chullah hood, chajjas, water troughs, mangers, shelves and similar articles with plain fair faces including chamferred, weatherings, throating etc including necessary form work complete all as specified and directed by Engineer-in-Charge Note: - Reinforcement shall be measured and paid for separately.
M&L for Brick work with sub class ‘B’ old size burnt bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:4) complete all as specified and directed by Engineer-in-charge.
M&L for Brick work with fly ash bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:4) complete all as specified and directed by Engineer-in-charge.
M&L for continuous brick edging (sub class ‘B’) with width equal to the width of brick laid dry on end vertically including necessary earth work, embedding bricks at depth as indicated and temping around bricks and removal of surplus soil to a distance not exceeding 50 metre and depositing where directed complete all as specified. Note : Each row shall be measured and paid separately.
M&L for 2nd class hard wood scantling, clean sawn timber unframed work and fixed complete all as specified and directed by Engineer-in-Charge.
S&F aluminium (Die cast) body door closer hydraulically regulated, designation No. 3 universal type, suitable for door shutters of 851 to 1000mm in width and weight between 61 to 80kg (ISI marked) complete all as specified and directed by Engineer-in-Charge.
S&F double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made out of mild steel heavy duty & fixed (ISI marked) complete all as specified and directed by Engineer-in-Charge.
S&F mild steel TMT bars 6 to 8 mm dia cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by Engineer-in-charge.
S&F steel rolling shutters (Thickness of laths 1.25mm) with ball bearing, including mild steel high tension spring of required length,mild steel tubes of 32mm to 50mm dia,cleat,anchoring rod, hasp,staple,stays and one shop coat of primer; erected in position complete including top cover as directed with gear operated type with bevel gear box and crank handle with safety lever lock complete all as specified and directed by Engineer-in-Charge.
S&F anodised aluminium frames powder coated (thickness of powder coating shall not less than 50 micron) for doors, windows, ventilators with one or more rebates including jointing cleats for fixing etc complete all as specified and directed by Engineer-in-Charge.
S&F anodised aluminium doors shutters powder coated (thickness of powder coating shall not less than 50 micron) sliding / openable having aluminium sections weighting 0.55 Kg/RM including necessary jointing cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, 100mm size, 4 levers brass mortice lock vertical type (01 No), hinges, anodised aluminium snap beading, screws complete all as specified and directed by Engineer-in-Charge.
S&F Anodised aluminium snap grid frame work of size 605mm x 605mm for false ceiling including necessary notching. The snap grid shall consist of anodized aluminium main & cross Tee of size 36.5mm x 25mm x 1.4mm weighing 0.24 Kg/RM and 23.5mm x 26.4mm x1.40mm weighing 0.191Kg/RM respectively. The main and cross tee shall be jointed at junction crossing with anodized aluminium angle bracket of size 15mm x 15mm x 1.5mm weighing 0.12Kg /RM fixed with suitable MS bolts, nuts and washer. The snap grid (main /cross tee section) shall be supported at ends all along the wall with anodized aluminium angle of size 35mm x 25mm x 2mm weighing 0.36 Kg/RM fixed to wall with suitable arrangement duly suspended with 3mm dia GI wire length as required @ 600mm C/C with adjustable device including plugging in brick / concrete work with steel raw plugs including making good all the disturebed portion complete all as specified and directed by Engineer-in-Charge.
M&L for 4mm thick E board classic, fibre base cement boards, embosed texture, fixed to aluminium snap grid (size of grid 605mm x 605mm) in ceiling complete all as specified and directed by Engineer-in-charge. Note :- The aluminium snap grid frame work shall be measured & paid for separately.
Demolition of mud phuska in roof any thickness including plastering & leeping (whether full thickness removed or only part thereof) complete all as specified and directed by Engineer-in-charge.
M&L for cleaning of all loose dirt and dust from roof and priming the surface with one coat of cold applied bituminious primer @ 0.40 Kg/Sqm conforming to IS:3384 and applying a layer of APP based polymeric membrane not less than 3 mm thick, weighing not less than 3.5 Kg/Sqm, reinforced with polyester non woven fabric (weighing not less than 150 gms/Sqm) and upper side of membrane thermally insulated with white gravel finish uniformaly embedded during manufacturing process. It shall be laid by torch application having side over lap 75 mm and at the end 100 mm, all overlaps and joints shall be sealed by torch application. For parapet, membrane shall be taken to a height of minimum 60 cm and inserted inside the parapet in a groove to a depth of 65mm. The same shall be furnished by a membrane flashing. Note : The net area of water proofing treatment shall be measured without any extra allowance for laps & portion inserted in groove which shall be deemed included in the quoted rates.
M&L for wire brushing and cleaning concrete surface on top of roof providing 20mm thick screed in cement mortar (1:4) over and including applying evenly a tack coat of bitumen 85/25 @ 1.20 KG/Sqm over and including 80mm thick average consolidated thickness mud phuska including 25mm thick mud plaster on flat roofs complete all as specified and directed by Engineer-in-charge.
M&L for 40mm thick brick tiles laid on mud mortar and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement on mud phuska complete all as specified and directed by Engineer-in-charge.
M&L for 75 mm thick PCC (1:3:6) type C-2 using 40 mm graded crushed stone aggregate as in plinth protection, finished fair and even complete all as specified and directed by Engineer-in-charge. Note :- Plinth protection shall be laid to slope (1 in 30) in bays not exceeding 3 metre in length and joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with sealing compound grade B. Cost of ceiling compund is included in the unit rate of this item
M&L for 50mm thick PCC (1:2:4) type B1 using 20mm graded stone aggregate as in flooring, finished even and smooth without using extra cement cement complete all as specified and as directed by Engineer-in-charge.
M&L for 100 mm thick PCC (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in sub base, finished fair and even complete all as specified and directed by Engineer-in-charge.
M&L for 100mm thick PCC 1:2:4 type B2 using 40mm graded crushed stone aggregate as in floor, top surface finished fair & even including spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green complete all as specified and as directed. Note :- PCC shall be laid in alternate bays in panels of size not exc 2m x 1m and joints shall be filled with bitumen mastic (1:3). Quoted rate shall deemed inclusive for same.
Roughening surface of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc in bldg and brushing neat cement slurry with 3 Kg of cement per Square metre complete all as specified and directed by Engineer-in-Charge.
S&F glass dividing strips 3mm thick 38mm wide inserted in position conforming to design complete all as specified and directed by Engineer-in-charge.
M&L for scratch proof ceramic coloured time 10mm thick, 600mm x 600mm area of each tile as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar (1:6) complete all as specified and directed by Engineer-in-charge.
M&L for glazed ceramic tiles (coloured) 450mm x 350mm x 7mm thick on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering in cement & sand mortar (1:4) including necesary cutting as per site requirment complete all as specified and directed by Engineer-in-charge.
S&F factory casted 100mm thick precast concrete interlocking paving blocks M-50 having compressive strength not less than 400 Kg / Sqcm using grey cement and with pigment and of shape hexagon/ triangular / zigzag / I-shaped / Three-X etc as directed conforming to IS 15658-2006, laid dry over and including 25mm thick layer of local tibba sand cushining over complete all as specified and directed by Engineer-in-Charge.
M&L for 15mm thick rendering in cement mortar (1:4) on brick walls/concrete surfaces mixed with water proofing compound as per manufacturer’s instructions including finishing the surfaces even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge. Note : - Supply only water proofing compound shall be measured and paid for separately under respective item of BOQ.
M&L for 15mm thick rendering in cement mortar (1:4) on fair faced or on other than fair face surface of brick masonary or concrete surface of walls, finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for 10mm thick rendering in cement mortar (1:3) on brick or concrete surface of ceiling, finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for rough cast finish plaster with a mixture consisting of crushed stone or fine gravel aggregate mixed with coarse sand and cement in the ratio of 1:1:1 over & including 12mm thick rendering in cement mortar 1:3 on fair faces of brick masonry or concrete surfaces of walls complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered surface of walls & applying two coats of cement base paint of approved shade/tint and filling cement based putty in cracks complete all as specified and directed by Engineer-in-charge.
M&L for preparation of old decorated, plastered or pointed surfaces of wall by brooming down or steel wire brushing,scrapping down smoke soot moulds, moss and efflorescent, salts and treating oil & greasy spots etc and applying one coat of white wash complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of old decorated, plastered or pointed surfaces of ceiling by brooming down or steel wire brushing,scrapping down smoke soot moulds, moss and efflorescent, salts and treating oil & greasy spots etc and applying two coat of white wash complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of old decorated, plastered or pointed surfaces of wall by brooming down or steel wire brushing,scrapping down smoke soot moulds, moss and efflorescent, salts and treating oil & greasy spots etc and applying two coat of white wash complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of new plastered and unplastered surfaces of wall and applying two coats of exterior Acrylic emulsion paint over and including one coat of primer as per manufacturer instruction complete all as specified & directed by Engineer-in-Charge.
M&L for complete removal of existing treatment from old plastered surfaces of wall, preparation of surfaces and applying two coats of oil bound distemper (OBD) over a coat of appropirate primer over and including 3mm thick layer of wall putty (Make J K or Birla) complete all as specified & directed by Engineer-in-Charge.
M&L for complete removal of existing treatment including preparation of surfaces including filling of cracks and applying two coats of cement base paint shade/tint over a coat of white wash on walls complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
M&L for preparation of old painted steel and iron surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint of approved tint complete all as specified and directed by Engineer-in-charge.
S&F 4.8mm thick sheet glass ordinary quality and glazing with oil putty in square exc 0.5 sqm in each pane including painting / oiling to new putty to match with the existing/new surfaces, complete all as specified and as directed.
S&F 5.5mm thick sheet glass ordianary quality glazing with oil putty in squares, area exceeding 0.50 Sqm in each pane area complete all as specified and directed by Engineer-in-Charge .
Supplying, laying, jointing and testing 300 mm bore reinforced cement concrete pipes, class NP-3 with collars complete all as specified and directed by Engineer-in-Charge.
M & L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in bed to drain pipe including forming cradles for 300mm dia of pipes and tested complete complete all as specified and directed by Engineer-in-Charge.
M&L for cutting into existing manhole/Septic tank/Soak well for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B1, smooth finished and reforming benching as required for 150mm bore pipe complete all as specified and directed by Engineer-in-charge.
Taking down carefully or drawing out from conduit, existing copper / aluminium point wiring for light, fan, bell, socket, power point etc complete including fixture and fittings such as switches, sockets, ceiling rose, pendent holder, light fittings, top sheet covers, fan regulators etc (excluding MS sunken boxes) and making good the disturbed surfaces of wall/ceiling complete all as specified and as directed by Engineer-in-charge. Note : Taking down of serviceable fittings shall be measured and paid separately.
M&L for point wiring complete with 1.5 sqmm (nominal cross sectional area) FRLSH PVC insulated multistandard unsheathed copper conductor cable with colour coding drawn in and including new PVC rigid conduit medium grade 20mm dia and suitable fittings, fixed on surface of wall or concealed or above ceiling with accessories such as pipe hooks, elbows, junction box, terminated in existing sunken box and covered with new 3mm thick bakelite plastic laminated sheet top cover fixed flush with wall using brass screws & cup washers including cutting chases in wall for conduits and making good the disturbed surfaces of wall and including 1.5 sqmm PVC insulated unshethed multistandard copper conductor wire as earth continuity to common earth and connecting to earth dolly for one light point, fan point, bell point controlled by one switch complete all as specified and directed by Engineer-in- charge.
All as per serial item No. 65 here-in-before but for One 3 pin 5 Amp socket outlet on the same board with other switches.
All as per serial item No. 65 here-in-before but for One 3 pin 5 Amp socket outlet on independent board.
All as per Srl item No. 65 above, but wiring with cable of cross sectional area 2.5 Sqmm (nominal area) multi-stranded copper conductor FRLSH, PVC unsheathed cable 1100 Volts shade for one switch socket combination 6 pin, 5/15 Amps on independent board including 2.5 Sqmm PVC insulated multistandard unsheathed copper conductor wire as earth continuity to common earth dolly.
S&F switch piano flush button 5 Amps single pole, one way complete all as specified and directed by Engineer-in-charge.
S&F switch socket combination 3 pin, 5 Amps, 240 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F switch socket combination 6 pin, 5/15 Amps, 230 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F socket outlet 3 pin, 5 Amps 240 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F Lamp holder, insulated body with back plate etc complete all as specified and as directed by Engineer-in-Charge.
S&F ceiling rose surface bakelite 65mmx50mm with two or three terminal complete all as specified and directed by Engineer-in-charge.
S&F electronic fan regulator suitable for ceiling fan 1200mm/1400mm sweep, socket size, rotary type complete all as specified and directed by Engineer-in-charge.
S&F in replacement flush mounting factory made SPN DB 8 way, 240 Volt, Double door, IP-43 protection, IK-09 with metal door with 100 Amps copper bus bar, with neutral bar, earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 507611 or equivalent in ABB / C&S / L&T / Schneider / Havells
S&F flush mounting factory made VTPN DB 4 way, 240 Volt, Double door, IP-43 protection, IK-09 with metal door with 160 Amps copper bus bar, with 02 neutral bar, 02 earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No DPX³ 507750 or equivalent in ABB / C&S / L&T / Schneider / Havells
S&F in replacement MCB 6 to 32 Amps, Single Pole 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408587 to 408595 or equivalent in ABB / C&S / L&T / Schneider / Havells
S&F in replacement MCB 40 Amps, Single Pole & neutral 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408618 or equivalent in ABB / C&S / L&T / Schneider / Havells
S&F MCB 32 Amps, Single Pole & Neutral 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408617 or equivalent in ABB / C&S / L&T / Schneider / Havells
S&F MCCB 4 Pole 100 Amps, thermal magnetic release having, breaking capacity 25 KA, 415 Volt in the existing feeder pillar box including any addition / alteration to the panel to accommodate the new MCCB & making connections with 25x3 mm copper strip as required from main bus bars, making necessary welding work, metal work for fixing base plate etc and connections complete all as specified and as directed by Engineer-in-Charge. Make : Legrand Cat Part No. DPX³ 160 420055 or equivalent in ABB / C&S / L&T / Schneider / Havells
Supply and fixing in replacement LED lamp minimum 3 star rated 12W LED B-22 base complete all as specified and directed by Engr-in-Charge with following specifications (a) Lumen system efficacy of lamp should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.90 (e) CRI : Morethan 80
S&F sheet metal plug & socket DB, SP, with a two pin and earth plug with socket, 230 Volts with & including one MCB SP ‘C’ Curve 10 kA, 20 Amps complete all as specified and directed by Engineer-in-charge. Make of DB :- Legrand Cat part No 507811 or equivalent in ABB / C&S / L&T / Schneider / Havells Make of MCB :- Legrand Cat Part No 408593 or equivalent in ABB / C&S / L&T / Schneider / Havells
S&F Energy efficient decorative ultra slim, prewired, lumiline 18 watt LED light fitting (Day cool light), batten type with drive & polycarbonate housing including tube rod and all accessories prewired fixed on wall / hanging complete all as specified and as directed by Engineer-in-charge. Make :- Havells Cat part No LUMILINEBS18WLED865S PCWH / Syska Cat part No SSK-RA1801 Wipro cat part No LL20-221-XXX-65-NE / Philips cat part No 61009 BL CDL / Crompton
S&F wall mounted fan 450 mm sweep, 7500 CPM, single phase, 230 volts, 50 Hz with IP 55 protection and connecting up and including 3 core,1.5 sqmm PVC insulated if required & PVC sheathed copper conductor flexible cable drawn in flexible conduit fixed on wall complete all as specified & directed by Engr-in-charge. Make :- Havells Model Airbol-Hi Speed or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply, installation, testing and commissioning Split Type Air conditioner Electric driven (Single phase) 2 Ton, five Star rating capacity with remote control including complete assecories all as per manufacturer's instructions in all respect as directed by Engineer-in-charge. Note :- Voltage stabilizer of required capacity shall be measured and paid for separeltly in respective item of BOQ.
Supply, installing & testing Voltage Stabilizer of capacity 5 KVA copper wound for automatic operation , single phase naturally air cooled indoor type & designed for input variation between 170V to 280V output voltage 230 V with accuracy of + 5% complete all as specified and directed by Engineer in charge.
S&F Sub main wiring complete with 2 single core 6 Sqmm (Nominal area) multi stranded copper conductor PVC insulated unsheathed cable FRLSH drawn in and including heavy duty PVC conduit ISI marked not less than 25mm dia concealed including single core multistranded copper conductor 6 Sqmm size cable as earth continuity wire drawn in same conduit complete all as specified and directed by Engineer-in- charge Note : Two runs of 6 Sqmm single core cable and one run of 6 sqmm copper wire earth continuty conductor and conduit with fittings shall be measured as one length.
S&F Recess mounting LED 2x2 luminaire, 36 watt, CCT 6000 k with drive, connector block etc. complete with all accessories internally pre-wired and including connecting up 3 core sheathed copper flexible cable 1.5 sqmm up to light fitting & connecting and testing complete all as specified and as directed by Engineer-in-charge. Make :- Crompton Cat Part No LCTLSNE-36-FO-CD / Philips Cat part No RC383B LED 36S-6500 PSU OD WH PIR / Syska Cat part No SSK-TVP-6060-36W / Havells Cat part No VENUSNEOHE2X2R36WLED840PIRSENSOR / Wipro Note :- Warranty of 5 years or 50000 burning hours shall be given by the contractor.
S&F in repair street light bracket made out of 40mm dia GI pipe light grade 1.20m long , bent to shape at 120 degree angle from vertical fixed along pole with and dirlling holes including required number of clamp made out of Flat iron 25mm x 6mm with nuts, bolts ,washers etc. duly painted with two coats of aluminium paint including any addition / alteration (if required) for fixing street light complete all as specified and as directed by Engineer-in-charge.
Supply and fixing energy efficient in replacement LED street light fitting of 30W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver, including electric connection, complete fitting with all accessories and following specifications and all as directed by Engr-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) CRI : Morethan 80 and CCT : 5700 K. (g) IP rating : IP66. (h) IK rating : Minimum IK07 (j) Built in potted LED Driver of the make as of the luminaire. (k) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (l) Surge protection 10 kV (inbuilt + extended) (m) Lens - High Efficiency wide angle lens. (n) BIS Approved fixtures and driver (o) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily) Make :- Syska, Crompton, Havells, Wipro, Philips
Notes for srl Item No 91 :- (a) Tenderer shall submit test report of LED street light fitting from Government accredited test laboratory for LM - 79 and LM - 80 . (b) Contractor has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of CA. Contractor shall obtain warranty from the manufacturer of product on their letter head and submit the same to deparment alonwith his letter head. The product will be replaced free of cost in the following case :- (i) Manfacturing defects (ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (c) All LED light/luminare must meet the provision laid down in IS - 16101 , 16102 Part -I/II ,16103 Part -I , 16104 ,16105 ,16106 , 16108/2012 and 15885 Part -II / Section 13. (d) Scope of work shall include supply and fixing street light fittings on street light bracket fixed on poles, If street light fitting requires to fixed on existing street light bracket and any addition alterration required in bracket for fixing street light, In that case cost of additional / alteration is included in the unit rate of this item, which also includes needful T & P and required accessories such as 1.5 sqmm, 3 core PVC insulated stranded copper conductor cable for connection from pole box to light fitting etc complete including making connection, testing etc complete .No extra payment is admissible on this account. (e) Light fittings shall be provided with 10 KV surge protection as mentioned in description of item. If 10 KV surge protection is not provided in light fitting for which cat part is mentioned in BOQ. Contractor has to provide light fitting with 10 KV surge protection without any extra cost to department. (f) Contractor shall write CA No on street light fitting with synthetic enamel paint which should be visible from ground level. Cost of the same is included in the unit rate of this item nothing shall be extra paid on this account.
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade top of pipe with funnel & wiremesh, and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mm thick RCC cover, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 including taking down old earthing complete all as specified and directed by Engr-in-charge. Notes :- (i) GI wire upto DBs or upto earth test point is included in this item. (ii) Outer edge of earth pit chamber shall be 1.5 metre away from the outer edge of PCC chamber. (iii) Minimum weight of reinforcement for RCC cover shall be 1 KG.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron strip 32mm x 6mm thick as earth lead by means of bolts, nuts and washers of galvanised iron or steel and thimbles and other end of the earth strip connected to earthing test point/equipment and protected by galvanised iron pipe light grade 40mm dia upto earthing test point/equipment fixed with required number of mild steel clamp made out of 25mm x 3mm flat iron and perforated water pipe 20mm dia GI medium grade of length 2.25 metre and top with socket & plug and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mmthick pre-cast RCC (1:2:4) type B-0 cover with 40mm x 40mm x 3mm MS angle iron frame, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete all as specified and directed by Engineer-in-charge. Notes :- (i) GI strip upto earth test point/equipment is included in this item. (ii) Outer edge of earth pit shall be 1.5 metre away from the outer edge of PCC chamber. (iii) Minimum weight of reinforcement for earth pit cover shall be 1 kg .
Supplying, laying, jointing, commissioning and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 50 sq mm 3.5 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc complete all as specified and directed by Engineer-in-charge. Notes :- (i) Excavation, earth work, sand cushioning, cable protection and GI pipe shall be measured & paid for separately under respective items of BOQ (ii) Road cutting / floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall deemed to be inclusive of the above provisions.
All as per item No 94 above but cable of cross sectional area 16 sq mm 2 core including taking out old cable
M&L for dry sand (Tibba sand) and punning for cushioning to underground cable complete all as specified and directed by Engineer-in-charge Note: - For payment purpose thickness after punning shall be measured.
M & L for brick protection with old size sub class 'B' bricks laid flat, length of bricks across the route of underground cable all as specified and directed by Engineer-in-Charge.
M & L for brick protection with old size sub class 'B' bricks laid flat, length of bricks across the route of underground cable including taking out old bricks all as specified and directed by Engineer-in-Charge.
S&F in repair Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches / under road / drains, fixed to poles / walls with required numbers of clamps made out of 25x3mm flat iron, bolts, nuts and washers for protection of LT electric cable complete all as specified and as directed by Engineer-in-charge. Notes :- (i) Excavation & earthwork shall be measured & paid for separately under respective items of BOQ (ii) Cost of flat iron clamp if required is included in the unit rate of this item. Nothing extra shall be paid on this account..
S&F copper suction pipe line of suitable size and gauge as per manufacturers recommendation complete with cutting, brazing and insulation work including fittings required at site complete all as specified and directed by Engineer-in-Charge.
S&F copper discharge pipe line of suitable size and gauge as per manufacturers recommendation complete with cutting, brazing and insulation work including fittings required at site complete all as specified and directed by Engineer-in-Charge. Note : - Pipe to be measured other than the standard qty received with units. -------------------------------------------------------------------------- Note :- A sum of Rs. 28921/- will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 31 (Schedule of Credit) of Tender documents.
S.K BUILDERS AND ENGINEERS
Gupta Suppliers
M/s JUGAL KISHORE MISHRA AND SONS
M/S Shree Ram Enterprises
PAREEK AND COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .