Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.1 CrAccepted-AOC RAHA P O RAHA P S RAHA DIST NAGAON ASSAM PIN 782103 | MARIGAON | ASSAM | 782103 | ₹5.1 Cr | L1 | Accepted-AOC Awarded |
| 2 | L2₹6.1 Cr+₹1.0 Cr (19.8%)Rejected-AOC NAGAON ASSAM | BONGAIGAON | ASSAM | 783371 | ₹6.1 Cr+₹1.0 Cr (19.8%) | L2 | Rejected-AOC Rejected |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹5.7 Cr
EMD Value
₹11.3 L
Closing Date
12 Dec 2022, 2:00 pmClosed
Chief Engineer (Roads), PWRD, Assam
O/o the Chief Engineer Roads, PWRD, Assam, Chandmari, Guwahati, 781003.
SOPD_G_22_23_08 Construction of Heliport under( RCS UDAN-2 ) at Nagaon under SOPD-G for the year 2022-23
2022_PWD_27868_1
CE/DEV/TB/233/2022-23/3
Open Tender
Civil Works
Item Rate
270 days
Nagaon
Please refer Tender documents.
4 documents required · 4 mandatory
₹11,350
₹11.3 L
Yes
O/o the Chief Engineer Roads, PWRD, Assam
27 Jun 2023
22 Nov 2022
13 Dec 2022
22 Nov 2022
12 Dec 2022
7 Dec 2022
22 Nov 2022 - 6 Dec 2022
6 Dec 2022
Amount
( PASSENGER TERMINAL BUILDING) Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m. All kinds of soil.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil
Diluting and injecting chemical emulsion for PRE CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under floors and apron using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the Plinth level : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification work in doses by weight of cement as per manufacturer's specification.
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately) All works upto Plinth level
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately) All works above plinth level upto floor V level
Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars
Centering and shuttering including strutting, propping etc. and removal of form for : Foundation, footing, bases of columns etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form for : Shelves
Centering and shuttering including strutting, propping etc. and removal of form for : Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : a) Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab upto 0.50 sqm
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab over 0.50 sum.
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.
Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors,windows and clelestory windows ( Area of opening for panel inserts excluding portion inside grooves or rebates to be measured).Panelling for panelled or panelled and glazed shuuters 25 mm to 40 mm thick: Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side ,Grade I,Type II,IS:12823 marked
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete. 300x16 mm
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 300x10 mm
Providing and fixing aluminium handle ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 125 mm
Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in-charge
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 10 x 60 mm
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC ( Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing.
Providing and fixing Colour Coated Galvalume Trapezoidal Profiled sheeting of 0.50mm Thickness tolerance +/-5% Total Coated Thickness TCT of material 550 Mpa for roofing/ cladding application. The Trapezoidal Profiled Sheet shall be 28-32 mm in Crest height with 2 Stiffener Ribs with Subtle Square Fluting in the six pans at Nominal 200 mm centre- to-centre. The end crest shall be designed for anti - capillary action , to avoid any seepage of water through the lateral overlap. The profile shall have return leg for proper side lap. Coating Specification: Primer Coat: 5-7 microns epoxy primer on both side of sheet. Top Coat: Polyester Top coat 15 -18 microns. Color: as approved by Engineer-in-charge Tolerances: As per IS standards: IS: 15961, IS: 513, IS: 14264. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing Colour Coated Galvalume Trapezoidal Profiled sheeting of 0.50mm Thickness tolerance +/-5% Total Coated Thickness TCT of material 550 Mpa for roofing/ cladding application. The Trapezoidal Profiled Sheet shall be 28-32 mm in Crest height with 2 Stiffener Ribs with Subtle Square Fluting in the six pans at Nominal 200 mm centre- to-centre. The end crest shall be designed for anti - capillary action , to avoid any seepage of water through the lateral overlap. The profile shall have return leg for proper side lap. Coating Specification: Primer Coat: 5-7 microns epoxy primer on both side of sheet. Top Coat: Polyester Top coat 15 -18 microns. Color: as approved by Engineer-in-charge Tolerances: As per IS standards: IS: 15961, IS: 513, IS: 14264. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. For Ridges plain (500 - 600mm)
Providing and fixing Colour Coated Galvalume Trapezoidal Profiled sheeting of 0.50mm Thickness tolerance +/-5% Total Coated Thickness TCT of material 550 Mpa for roofing/ cladding application. The Trapezoidal Profiled Sheet shall be 28-32 mm in Crest height with 2 Stiffener Ribs with Subtle Square Fluting in the six pans at Nominal 200 mm centre- to-centre. The end crest shall be designed for anti - capillary action , to avoid any seepage of water through the lateral overlap. The profile shall have return leg for proper side lap. Coating Specification: Primer Coat: 5-7 microns epoxy primer on both side of sheet. Top Coat: Polyester Top coat 15 -18 microns. Color: as approved by Engineer-in-charge Tolerances: As per IS standards: IS: 15961, IS: 513, IS: 14264. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. For Gutter .(600 mm over all girth)
12 mm cement plaster of mix : 1:6 (1 cement : 6 coarse sand)
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand).
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. on steel work
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. TWO COATS
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete.
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With brass cover plate minimum 1.25 mm thickness
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.
Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge. Anodized (AC 15 ) aluminium tubular handle bar
Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 8 mm thickness
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings, the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)- cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, roviding suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid,installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and unctional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and rotection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance haracteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineerin-Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places. Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories ccreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable eparately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories Performance Laboratory Test for Air Leakage Test (-50pa to – 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr” Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331- 09 testing method for a range up to 2000 ml.” Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml” Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME- 330-10 testing method for a range upto 50 mm” Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test” Tests to be conducted on site 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml” Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.“(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2)“For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.“ Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I.brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps.
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and points of approved quality conforming to IS:8931 a) 15 mm nominal bore 15 mm nominal bore
Providing and fixing toilet paper holder : C.P. brass
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms
Providing and fixing of CP brass Health faucet with 8mm dia 1mtr. Long PVC tube and wall hook fixed to wall with rawl plug and CP brass screws complete. (Make: Jaquar Cat. No.ALD-CHR-583 or equivalent make as approved by Engineer-in-Charge)
Prividing and Fixing 1.5 feet long connecting hose with nuts at both ends complete.(Make: Jaquar Cat.No.ALD-803B or equivalent make as approved by Engineer-in-Charge) for health faucet
Providing and fixing polyethylene-Aluminium- Polyethylene (PE-ALPE) composite pressure pipe IS confirming 15450-UV atablized with corbon black having thermal stability for hot&cold water supply, capable to with stand temperature upto 80*c including all special fittings of composite material (Engineering plastic blend and brass inserts wherever required ) e.g. elbows, tees, reducer, coupler & connectors etc.with clamps at 1 metre spacing. This includes the cost of cutting chases and including testing of joints compelete as per the direction of engineer in charge. Expose wall work. including cutting chases and making good the wall etc. 32 mm nominal outer dia Pipes
Providing and fixing polyethylene-Aluminium- Polyethylene (PE-ALPE) composite pressure pipe IS confirming 15450-UV atablized with corbon black having thermal stability for hot&cold water supply, capable to with stand temperature upto 80*c including all special fittings of composite material (Engineering plastic blend and brass inserts wherever required ) e.g. elbows, tees, reducer, coupler & connectors etc.with clamps at 1 metre spacing. This includes the cost of cutting chases and including testing of joints compelete as per the direction of engineer in charge. Expose wall work. including cutting chases and making good the wall etc. 40 mm nominal outer dia Pipes
Providing and fixing polyethylene-Aluminium- Polyethylene (PE-ALPE) composite pressure pipe IS confirming 15450-UV atablized with corbon black having thermal stability for hot&cold water supply, capable to with stand temperature upto 80*c including all special fittings of composite material (Engineering plastic blend and brass inserts wherever required ) e.g. elbows, tees, reducer, coupler & connectors etc.with clamps at 1 metre spacing. This includes the cost of cutting chases and including testing of joints compelete as per the direction of engineer in charge. Concealed work. including cutting chases and making good the wall etc. 20 mm nominal outer dia Pipes
Providing and fixing polyethylene-Aluminium- Polyethylene (PE-ALPE) composite pressure pipe IS confirming 15450-UV atablized with corbon black having thermal stability for hot&cold water supply, capable to with stand temperature upto 80*c including all special fittings of composite material (Engineering plastic blend and brass inserts wherever required ) e.g. elbows, tees, reducer, coupler & connectors etc.with clamps at 1 metre spacing. This includes the cost of cutting chases and including testing of joints compelete as per the direction of engineer in charge. Concealed work. including cutting chases and making good the wall etc. 25 mm nominal outer dia Pipes
Providing and fixing polyethylene-Aluminium- Polyethylene (PE-ALPE) composite pressure pipe IS confirming 15450-UV atablized with corbon black having thermal stability for hot&cold water supply, capable to with stand temperature upto 80*c including all special fittings of composite material (Engineering plastic blend and brass inserts wherever required ) e.g. elbows, tees, reducer, coupler & connectors etc.with clamps at 1 metre spacing. This includes the cost of cutting chases and including testing of joints compelete as per the direction of engineer in charge. Concealed work. including cutting chases and making good the wall etc. 32 mm nominal outer dia Pipes
Providing and fixing Polyethelene-Aluminium- Polyethelene (PE-AL-PE) Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with trenching, refilling and testing of joints complete as per direction of the engineer in charge. 2532 (32 mm OD ) pipe
Providing and fixing Polyethelene-Aluminium- Polyethelene (PE-AL-PE) Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with trenching, refilling and testing of joints complete as per direction of the engineer in charge. 3240 (40 mm OD ) pipe
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 20 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm dia
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 25 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 40 mm dia nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Circular tank
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing in position uPVC SWR floor trap conforming to IS:13592 including providing necessary steel support and as per Specification. Making proper connection cutting chase / hole in floors / slabs and bringing the same in proper condition and shape after placing the trap in right position complete as required. The hopper and trap shall be set in cement concrete mix 1:2:4 complete as required. (P/S trap) Make: Supreme/Ashirvad/Prince or equivalent as approved by engineer-in-charge. (110X110mm)
Providing and fixing uPVC SWR Pipes class B (IS:13592) with all injection moulded fittings complete including jointing with solvent cement including cutting and making good the walls wherever required. (For soil & waste pipes). Nothing extra will be paid for supports.(Inside Toilets, Kitchen).Make: Make: Supreme/Ashirvad/Prince or equivalent as approved by engineer-in-charge. 160 mm outer dia
Providing and fixing uPVC SWR Pipes class B (IS:13592) with all injection moulded fittings complete including jointing with solvent cement including cutting and making good the walls wherever required. (For soil & waste pipes). Nothing extra will be paid for supports.(Inside Toilets, Kitchen).Make: Make: Supreme/Ashirvad/Prince or equivalent as approved by engineer-in-charge. 110 mm outer dia
Providing and fixing uPVC SWR Pipes class B (IS:13592) with all injection moulded fittings complete including jointing with solvent cement including cutting and making good the walls wherever required. (For soil & waste pipes). Nothing extra will be paid for supports.(Inside Toilets, Kitchen).Make: Supreme, Ashirvad & Prince 75 mm outer dia
Providing and fixing 100% stainless steel grating of approved make and quality grade 304 on top of floor trap. The rate includes the cost of all ancillary works and material as required to complete the works. 127mm (Cat No.-SKSH5,Hilti & chili)
Providing, laying & jointing in position uPVC pipe conforming to IS:4985:1988 and suitable for the respective working pressures with all fittings and accessories e.g. couplings, tees, bends, reducers, clamps, screwed adapters, flanged tail pieces etc. jointing as per manufacturers' instructions and making good the wall and floor as reuired.Make: Make: Supreme/Ashirvad/Prince or equivalent as approved by engineer-in-charge. PVC pipe 110mm-6 kg/cm2
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. Cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
Extra for depth of manholes: Size 90 x 80 cm With Sewer bricks conforming to IS : 4885
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 100x100 mm size P type. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Supplying and Fixing First Aid Hose Reel, wall mounting swinging type complete with drum & bracket of MS construction, spray painted in Post office Red, confirming to IS 884/1995 with upto date amendments, complete with the following as required. 36 Meter long 20 mm dia water hose Thermoplastic (Textile reinforced) Type - 2 as per IS : 12585 25 mm dia ball valve & nozzle. Pressure guage Drum and brackets for fixing the equipments on wall. Connection from riser with stop valve (gun metal) & M.S. Pipe
Providing and fixing M.S. cabinet fabricated from 16 g sheet with full front glass door and locking arrangement duly painted with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade and suitably mounted on a raised platform as required (Approx.0.6 m x 0.6 M x 0.45 M ).
SUPPLY, INSTALLATION, TESTING & COMMISSIONING Mild Steel black pipe (IS: 1239 Part-1) heavy class including cutting, screwing, welding etc. complete with fitting viz. tees elbow, bends, flanges, dead flange,reducers. etc including excavation (upto 1.5M deep). Rubble soling, sand filling upto 3 " above the pipe, back-filling with excavated earth, removal of surplus soil and providing anti-corrosive treatment (coating and wrapping) with 4 mm thick tape and holiday test check as per IS: 10221complete as required. Note : Pipes upto and 40 mm dia shall be standard threaded forged steel fittings joints, above 40mm shall be standard M.S. fittings with welded joints.Jindal Hissar/TATA 100mm dia
SUPPLY, INSTALLATION, TESTING & COMMISSIONING Mild Steel black pipe (IS: 1239 Part-1) heavy class including cutting, screwing, welding etc. complete with fitting viz. tees elbow, bends, flanges, dead flange,reducers. etc including excavation (upto 1.5M deep). Rubble soling, sand filling upto 3 " above the pipe, back-filling with excavated earth, removal of surplus soil and providing anti-corrosive treatment (coating and wrapping) with 4 mm thick tape and holiday test check as per IS: 10221complete as required. Note : Pipes upto and 40 mm dia shall be standard threaded forged steel fittings joints, above 40mm shall be standard M.S. fittings with welded joints.Jindal Hissar/TATA 80mm dia
SUPPLY, INSTALLATION, TESTING & COMMISSIONING Mild Steel black pipe (IS: 1239 Part-1) heavy class including cutting, screwing, welding etc. complete with fitting viz. tees elbow, bends, flanges, dead flange,reducers. etc including excavation (upto 1.5M deep). Rubble soling, sand filling upto 3 " above the pipe, back-filling with excavated earth, removal of surplus soil and providing anti-corrosive treatment (coating and wrapping) with 4 mm thick tape and holiday test check as per IS: 10221complete as required. Note : Pipes upto and 40 mm dia shall be standard threaded forged steel fittings joints, above 40mm shall be standard M.S. fittings with welded joints.Jindal Hissar/TATA 50mm dia
SUPPLY, INSTALLATION, TESTING & COMMISSIONING Mild Steel black pipe (IS: 1239 Part-1) heavy class including cutting, screwing, welding etc. complete with fitting viz. tees elbow, bends, flanges, dead flange,reducers. etc including excavation (upto 1.5M deep). Rubble soling, sand filling upto 3 " above the pipe, back-filling with excavated earth, removal of surplus soil and providing anti-corrosive treatment (coating and wrapping) with 4 mm thick tape and holiday test check as per IS: 10221complete as required. Note : Pipes upto and 40 mm dia shall be standard threaded forged steel fittings joints, above 40mm shall be standard M.S. fittings with welded joints.Jindal Hissar/TATA 25mm dia
SUPPLY, INSTALLATION, TESTING & COMMISSIONING Mild Steel black pipe (IS: 1239 Part-1) heavy class including cutting, screwing, welding etc. complete with fitting viz. tees elbow, bends, flanges, dead flange,reducers. etc including excavation (upto 1.5M deep). Rubble soling, sand filling upto 3 " above the pipe, back-filling with excavated earth, removal of surplus soil and providing anti-corrosive treatment (coating and wrapping) with 4 mm thick tape and holiday test check as per IS: 10221complete as required. Note : Pipes upto and 40 mm dia shall be standard threaded forged steel fittings joints, above 40mm shall be standard M.S. fittings with welded joints.Jindal Hissar/TATA 20mm dia
Providing and fixing cast iron double flanged non return valves of PN1.6 including nuts, bolts, 3mm thick compressed asbestos gasket, Gunmetal seat, Drilling as per IS:1538, matching flanges as per table "E" complete as per IS:5312 swing type.(For Pumps Only) Makes:ZOLOTO/NVR/DEEPAK. 100 MM
Providing and fixing C.I. butterfly valves PN 1.6 complete with Nitrile liner, SS disc, SS stem, bolts, nuts 1.5mm thick compressed asbestos gasket companion flanges as per table "E" complete as per IS:13095. Makes:ZOLOTO/NVR/DEEPAK or equivalent as approved by engineer-in-charge. 100mm dia
Providing and fixing C.I. butterfly valves PN 1.6 complete with Nitrile liner, SS disc, SS stem, bolts, nuts 1.5mm thick compressed asbestos gasket companion flanges as per table "E" complete as per IS:13095. Makes:ZOLOTO/NVR/DEEPAK or equivalent as approved by engineer-in-charge. 80mm dia
SUPPLY & FIXING OF ISI (IS:15683) marked Portable fire Extinguisher Water type stored pressure (stored pressure) capacity 9 ltrs. with gun-metal cap and nozzle and complete in all respects including initial fill and wall suspension bracket. Capacity 9 ltrs.
SUPPLY & FIXING OF ISI marked (IS:15683) Portable fire Extinguisher, Carbon-dioxide type flat base including valve, discnarge hose of not less than 10 mm dia. 1m long & complete in all respects including initial fill with C02 gas confirming to IS:307-1966 filled to a filling ratio of not more than 0.667of not more than 0.667and wall suspension bracket.
Supply and fixing Powder Fire Extinguisher (Stored Pressure type-6 kg weight) duly ISI marked conforming to IS:15683:20006,with IS 14609,ISI marked ABC powder complete with squeeze grip release valve,discharge pipe,locking arrangement,pressure gauge,opeartion manual and bracket.Opearting Temperature:- 10°C to 55 °C.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group – C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 10 sq. mm + 1 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing of call bell / buzzer suitable for single phase,230 volt complete as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 25 amps modular socket outlet and 25 amps modular SP MCB ''C" curve including connection, penting etc as required. (for Geyser & AC)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair (4 core) unarmoured cable from Tag block to LV box
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 20mm dia conduit pipe
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 25mm dia conduit pipe
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Supplying and fixing M.S. box with modular type telephone (RJ-11) outlet for Telephone/Intercom complete as required.
Supplying and fixing of 1 or 2 module (75mm x75mm) size GI boxes with modular base and cover plate for modular switches in recess etc complete as required
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way, Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way Double door
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required.
Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required.
Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required.
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Supplying, installation, testing & commissioning of digital audio amplifier 50 Watt, 25V rms operating at 240 volt AC supply complete as required.
Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required.
Supplly, laying connecting and testing of multi-core telephone armoured/ unarmoured cable of conductor size 0.6mm dia annealed copper conductor PVC insulated PVC sheathed jelly filled (as per DOT specification) cable as required 20 Pair telephone armoured cable
Supplly, fixing connecting and testing of under noted size of solderless telephone tag block Krone make in surface/recess in wall required size of M.S. box with hinged lockable cover duly stove enamel painted. 20 pair tag block
Supplying and fixing M.S. box with modular type (RJ-45) outlet for LAN complete as required.
Supplly, installation testing and commissioning of pure server based IP-PBX with 24 Analog extension with CLI facilities System complete as required
Supply installation testing and commissioning of Brodband Lan connection complete as required with 10MBPS Speed.
Supply installation testing and commissioning of 24 port L2 Managed switch having port density 24 Nos of 10M/100M/1G RJ45 Port POE /POE+ ports , 2 Nos of GbE RJ45/SFP Combo Port , 1X console port , Available POE power 370 W , 52 Gbps switching bandwidth , 8K MAC address support , Support L2 feature STP, RSTP ,MSTP . Support 802.1Q VLAN , port based VLAN , 4K VLAN entries , MAC based VLAN , IP subnet based VLAN . Support IEEE 802.3ad LACP . L3 features - static routing , DHCP feature , Device Management system - topology view , floor view , map view , dashboard , traffic monitoring , cable diagnostics.CE,FCC certified. (Approved make - Cisco/Juniper/Axis/Impulse/Mobotix/Avigilon)
Design, manufacture, supply, installation, testing and commissioning of 2 mm thick MS sheet steel fabricated cubicle type Panel dust and vermin proof complete with hinged and lockable doors . The Sheet Steel shall under go minimum eight tank treatment followed by finishing treatment of powder coating with 70 micron minimum thickness. All the panels shall be floor mounted and dead front construction complete with interconnections. Note:- The panels shall be FRONT operated, with cable entry from the top bottom. Earth bus shall be part of the panel.) (All MCB to be "C" Curve) The following provisions shall be required to be made in the Distribution Panel as detailed below: All live accessible parts shall be shrouded with 1mm thick polycarbonate/3 mm thick FRP sheet and all equipment shall be finger touch proof. The busbar insulation shall be with heat shrinkable sleeves according to the colour code. SMC shrouds and busbar supports shall be used. All MCCB door handle shall be interlocked and lockable in OFF position. Galvanised hardware with zinc passivation shall be used in fabrication of Switchboards. Suitable Aluminium earth bus to be provided throughout the length of Switchboards. All indication lamps / illuminated push buttons shall be LED type. Coil of all motor starters shall be fed from 440 V / 230 V Control Transformer. 2A SP MCBs shall be used as backup protections. All MCCBs shall be variable plug setting type with thermal magnetic Ics = 100% Icu & rotary handle. All control& power wiring shall be broughtout upto the cable alley in the terminal blocks.An approval shall be taken for each panel before manufacturing. Provision of one 6/16 amp socket & compartment lighting for each vertical section of main panel.All breaking Capacity for MCCB to be Ics=100%Icu. All MCB to be C Curve MDB-1 Incoming: 1 no. of 250 Amp FP MCCB of 16 KA breaking capacity & Trip setting as required. Metering for incoming: Digital Multifunction meter (MFM-4) with RS-485 communication port for measurement of PF, V, A & Hz , equivalent to EM6459, with CT as required. Phase indicating lamps RYB with 2 Amps SP MCB back up. BUSBAR Electrolytic high conductivity aluminium three phase and neutral busbars rated at 300 amps, 16KA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. Current density of Bus Bar to be 1.2 sq.mm / amp. OUTGOINGS 3 nos. 63 Amps 10 kA 440 volt FP MCB .1 nos. 100 Amps 16 kA 440 volt FP MCCB along with 100A FP Contactor. 1 nos. 63 Amps 16 kA 440 volt FP MCCB. 3 nos. 40 Amps 10 kA 440 volt FP MCB . 1 nos. 40 Amps 10 kA 440 volt DP MCB . MDB describe as avove complete in all repect.
Supply and fixing of 2mm thick CRCA sheet steel powder coated Raceway of following sizes complete with bend/tee joints, coupling plate & nuts bolts etc. including providing and fixing of M.S. painted hanger etc. as required. 150mm wide 50 mm depth
Supplying, fixing, testing and commissioning of recessed mounted luminaire of 34W LED 600x600mm of 5700K suitable for operation on 230 volt 50 Hz,Single Phase AC supply with all accessories complete for ceiling. Havells Cat No: LHEWEBP6IN1W034 or equivalent make.
Supply, Installation, testing & Commissioning of recessed Mounted circular 12W LED downlighter with CRCA / pressure diecast aluminimum heat sink & white finish polycarbonate diffuser , complete with electronic LED driver, efficacy better than 90 lumens / watt with CRI> 80 including making suitable arrangement for fixing on false ceiling & connection complete as required.
Supplying, fixing, testing and commissioning of Flood light of 70W LED light suitable for operation on 230 volt 50 Hz,Single Phase AC supply with all accessories complete as required
Supply, Installation, testing & Commissioning of 8W LED Mirror Light complete as required.
Supplying, fixing, testing and commissioning of following size exhaust/ fresh air fan complete with gravity louver and connection with 3 core flexible wire as required. 300mm 1400 RPM Heavy duty Metal exhaust fan Havells make model: Turbo Force SP or equivalent preferred makes.
Supply and installation of wall bracket fan of 400mm,sweep complete with fan motor, blades etc. with all accessories etc. of approved make as required.
Supplying, erection, connecting, testing and commissioning of 1200mm sweep ceiling fan complete with GI Fan Box, blades, down rod, shackle insulator, canopy etc. including providing of electronic step regulator with faceplate matching the existing modular switches as required. (Similar to Havells-Pacer)
Supply, unloading, installation at Ground Floor, testing & commissiong of micro processor / DSP controlled 5 KVA UPS, IGBT based rectifier to achieve THDI < 5% and input power factor of greater than 0.95 at 50% loading. True Online Double Conversion (VFI as per IEC 62040-3) UPS using PWM IGBT technology , 1 Phase input and 1 phase 230 V output UPS system; and each comprising of the following:125% rated Rectifier cum charger unit +100% rated Invertor, Integrated in UPS module100% rated External Galvanic isolation transformers of K-13 Delta/Zigzag type for isolation of input neutral with output neutral ,to be installed after UPS as shown in drawing enclosed 100% rated Inbuilt static switch at the invertor output + 2 Nos. 100% rated Inbuilt static switches at the static bypass line 100% rated Inbuilt Maintenance Bypass. 100% rated moulded case battery circuit breaker having Ithermal, Imagnetic and Automatic U/V trip mechanics.Web-enabled Monitoring and Management through SNMP protocols for multi-OS environments.Supplying, unloading, installation at basement, testing and commissioning of Lead Acid sealed maintenance free batteries for 5 KVA UPS system, for providing 15 minutes backup to 5 KVA UPS for full load. The bank of batteries shall comprise required Nos of batteries complete as required. Battery sizing calculation are to be submitted for approval Supply, unloading, installation at basement, testing & commissioning of matching cabinet/open racks to house SMF batteries for 5 KVA UPS system along with interconnecting links, MCB etc. complete as required & as per specifications. Supply, laying, testing & commissioning of flexible single core copper cable of Finolex / Skyline / Havell's / Nyvin make for interconnections between UPS to UPS, UPS to batteries, UPS to Isolation Transformer, complete as required for 5 KVA UPS,including providing Battery circuit breakers as required.Supply, installation, testing and commissioning of UPS monitoring software suitable for RJ-45 communication and capable of giving pop up messages for all alarms received from UPS. It shall be capable of the following:-Giving notifications like e-mail, paging notification, broadcast notification, battery replacement notification, run event-based scripts.Event logging, data logging and action logging (with date, time, description of fault and event). Run the battery diagnostic test.Automated unattended shutdown of computers. Local notification through audible alarm.Software should support Microsoft Windows NT / 2000 / Server, 2003/XP, AIX, HP-UX, Sun Solaris, Linux, Novell Netware UPS describe as avove complete in all repect.
Providing and fixing of self illuminated / auto glow "EXIT" signs printed on photoluminescent sheet containing self illuminated base chemical, of appropriate size not less than 400 x 150 mm, suspended from ceiling or fixed to the walls with accessories as required and as directed at site.
Supply, installation, testing and commissioning of colour Dome camera with 2 Megapixel along with suitable lens, stainles steel brush finish plate etc. complete as required & as per specifications. (For Basement Lift Lobby and Entrance Hall & Terrace Lobby)
Supply, installation, testing and commissioning of C/CS - Metal body colour Day and Night High Resolution 540 lines with autoiris lens including weather proof housing IP-66, suitable mounting bracket with approved finish & colour complete as required as per specification. (For Main Gate Entry / Exit )
Supply, installation, testing and commissioning of 1Professional DVR with 16 Video Inputs, H.264 Compression - D1 Display Resolution with 2.5TB HDD, Expandable up to 8 TB. Total recording frames @ 400 fps. Recording based on Continuous, Motion, Scheduled or alarm, Remote backup through TCP/IP,HTTP Networkable, backup by USB/DVDWR, Client software included, POS Transaction data recording with image. Supplied with Licensed OS, keyboard & mouse. complete as required and as per specifications. The DVR shall be integrated with Access control system. (Along with 2 nos. 4 TB.)
40" Full HD LED Professional Display for Monitoring with mounting accessories.
Supply, installation, testing and commissioning of Hi-wall Split Unit (5 Star Rating) with rotary compressor & cordless control of following capacity with wall/floor mounted outdoor unit stand. 1.5 TR Air-Cooled Split Unit ( Heating + Cooling)
Supply, installation, testing and commissioning of Hi-wall Split Unit (5 Star Rating) with rotary compressor & cordless control of following capacity with wall/floor mounted outdoor unit stand. 2.0 TR Air-Cooled Split Unit ( Heating + Cooling)
Supply, installation, testing and commissioning of additional refrigerant piping (two lengths) duly insulated with 25 mm for indoor application and 38 mm for outdoor application closed cell nitrile rubber of density 60+/-10% Kg/m3 to interconnect indoor & outdoor units for each circuit. For 1.5 TR Unit
Supply, installation, testing and commissioning of additional refrigerant piping (two lengths) duly insulated with 25 mm for indoor application and 38 mm for outdoor application closed cell nitrile rubber of density 60+/-10% Kg/m3 to interconnect indoor & outdoor units for each circuit. For 2.0 TR Unit
Supply, installation, testing & commissioning of PVC Hard drain piping with fittings, valves & insulation with 13 mm for indoor application closed cell nitrile rubber of density 60+/-10% Kg/m3. 25 mm Dia. of pipe, PVC Hard Pipe
Supply, installation, testing & commissioning of PVC Hard drain piping with fittings, valves & insulation with 13 mm for indoor application closed cell nitrile rubber of density 60+/-10% Kg/m3. 32 mm Dia. of pipe, PVC Hard Pipe
( PAVEMENT & DRAIN )Removal of unsuitable soil including excavation, loading and disposal upto 1000 m lead but excluding compaction ground supporting embankment subgrade replacement by suitable soil, which shall be paid separately as per Clause 303.5.2 as per Technical Specification Clause 302.3.11
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting p g to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade ‘A’ sealing compound.
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-III (size range 26.5 mm to 0.075 mm ) having CBR Value-20
Construction of dry lean cement concrete sub base over a prepared sub-grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications, cement content not to be less than 150 Kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc. complete as per direction of Engineerin- charge.
Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge, i/c cleaning the surface of ail dirt, scales, oil, grease and other foreign material etc. and lining out complete. New work (Two or more coats)
Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
Pavement Quality Concrete:- Construction of reinforced M-40 Grade pavement quality concrete of flexural strengthe 45 kg/cm2 over a prepared sub-base with 43 grade cement, with minimum cement content of 390 kg per cum or as per mix design (whichever is more), coarse and fine aggregate conforming to IS:383 with 20 mm nominal size of aggregate, mixing in a batching and mixing plant as per approved mix design (As per IRC-44), transported to site, laid with a fixed form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction, longitudinal & tranverse joints, joint cutting, joint filler, backer rod conforming to ASTMC:%249-95 or ASTMD:3575, separation membrane (400 micron HDPE Sheet), sealent primer, polyurethene joint sealant with min MAF+30, reinforcement, admixtures as approved, curing compount, finishing to lines and grades as per drawing and direction of Engineer-in-charge. Note:- 1) Details of HDPE Sheet:- 400 micron HDPE Sheet over tack coat of 2.5 Kg/10mtr2 of VGRO HDPE with minimum width of 8 m without joints, 400 micron manufactureres by multilayer technology using 100% virgin raw material, conforming to IS 10889:2004 (or latest) with company logo & IS Code & batch number on at least very 2 metres. 2) Manufacturer Test certificate for every sonsignment.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All works upto plinth level
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster
(WATCH TOWER )Surface dressing of the ground including removing vegetation and in- equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. All works upto plinth level
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing Colour Coated Galvalume Trapezoidal profiled sheeting of 0.50 mm Thickness tolerance +/-5% Total Coated Thickness TCT of material 550 Mpa for roofing / cladding application. The Trapezoidal Profiled sheet shall be 28-32 mm in Crest heigfht with 2 Stiffener Ribs with Subtale Square Fluting in the six pans at Nominal 200 mm centre-to-centre. The end crest shall be designed for anti - capillary action, to avoid any seepage of water through the lateral overlap. The profile shall have return leg for proper side lap. Coating Specification: Primer Coat: 5-7 microns epoxy primer on both side of sheet. Top Coat: Polyester Top coat 15-18 microns. Color: as approved by Engineer-in-charge Tolerances: As per IS standards: IS: 15961, IS:513, IS:14264 The sheet shall be fixed using self drilling / self tapping screws of size (5.5 x 55 mm) with EPDM seal, complete upto any pitch in horizontal / vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing Colour Coated Galvalume Trapezoidal profiled sheeting of 0.50 mm Thickness tolerance +/-5% Total Coated Thickness TCT of material 550 Mpa for roofing / cladding application. The Trapezoidal Profiled sheet shall be 28-32 mm in Crest heigfht with 2 Stiffener Ribs with Subtale Square Fluting in the six pans at Nominal 200 mm centre-to-centre. The end crest shall be designed for anti - capillary action, to avoid any seepage of water through the lateral overlap. The profile shall have return leg for proper side lap. Coating Specification: Primer Coat: 5-7 microns epoxy primer on both side of sheet. Top Coat: Polyester Top coat 15-18 microns. Color: as approved by Engineer-in-charge Tolerances: As per IS standards: IS: 15961, IS:513, IS:14264 The sheet shall be fixed using self drilling / self tapping screws of size (5.5 x 55 mm) with EPDM seal, complete upto any pitch in horizontal / vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. For Ridges plain (500-600 mm)
Providing and fixing Colour Coated Galvalume Trapezoidal profiled sheeting of 0.50 mm Thickness tolerance +/-5% Total Coated Thickness TCT of material 550 Mpa for roofing / cladding application. The Trapezoidal Profiled sheet shall be 28-32 mm in Crest heigfht with 2 Stiffener Ribs with Subtale Square Fluting in the six pans at Nominal 200 mm centre-to-centre. The end crest shall be designed for anti - capillary action, to avoid any seepage of water through the lateral overlap. The profile shall have return leg for proper side lap. Coating Specification: Primer Coat: 5-7 microns epoxy primer on both side of sheet. Top Coat: Polyester Top coat 15-18 microns. Color: as approved by Engineer-in-charge Tolerances: As per IS standards: IS: 15961, IS:513, IS:14264 The sheet shall be fixed using self drilling / self tapping screws of size (5.5 x 55 mm) with EPDM seal, complete upto any pitch in horizontal / vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. For Gutter (600 mm overall girth)
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work
Supplying and stacking at site. Good earth
(SECURITY HUT) Surface dressing of the ground including removing vegetation and in- equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for PRE-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under floors and apron using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the plinth level: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification.
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). All works upto plinth level
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). All works above plinth level upto floor V level
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form for : Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab upto 0.50 sqm
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 300x10 mm
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper
Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in-charge.
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.5 mm thick
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 10 x 120 mm
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing and fixing Colour Coated Galvalume Trapezoidal profiled sheeting of 0.50 mm Thickness tolerance +/-5% Total Coated Thickness TCT of material 550 Mpa for roofing / cladding application. The Trapezoidal Profiled sheet shall be 28-32 mm in Crest heigfht with 2 Stiffener Ribs with Subtale Square Fluting in the six pans at Nominal 200 mm centre-to-centre. The end crest shall be designed for anti - capillary action, to avoid any seepage of water through the lateral overlap. The profile shall have return leg for proper side lap. Coating Specification: Primer Coat: 5-7 microns epoxy primer on both side of sheet. Top Coat: Polyester Top coat 15-18 microns. Color: as approved by Engineer-in-charge Tolerances: As per IS standards: IS: 15961, IS:513, IS:14264 The sheet shall be fixed using self drilling / self tapping screws of size (5.5 x 55 mm) with EPDM seal, complete upto any pitch in horizontal / vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing Colour Coated Galvalume Trapezoidal profiled sheeting of 0.50 mm Thickness tolerance +/-5% Total Coated Thickness TCT of material 550 Mpa for roofing / cladding application. The Trapezoidal Profiled sheet shall be 28-32 mm in Crest heigfht with 2 Stiffener Ribs with Subtale Square Fluting in the six pans at Nominal 200 mm centre-to-centre. The end crest shall be designed for anti - capillary action, to avoid any seepage of water through the lateral overlap. The profile shall have return leg for proper side lap. Coating Specification: Primer Coat: 5-7 microns epoxy primer on both side of sheet. Top Coat: Polyester Top coat 15-18 microns. Color: as approved by Engineer-in-charge Tolerances: As per IS standards: IS: 15961, IS:513, IS:14264 The sheet shall be fixed using self drilling / self tapping screws of size (5.5 x 55 mm) with EPDM seal, complete upto any pitch in horizontal / vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. For Ridges plain (500-600 mm)
Providing and fixing Colour Coated Galvalume Trapezoidal profiled sheeting of 0.50 mm Thickness tolerance +/-5% Total Coated Thickness TCT of material 550 Mpa for roofing / cladding application. The Trapezoidal Profiled sheet shall be 28-32 mm in Crest heigfht with 2 Stiffener Ribs with Subtale Square Fluting in the six pans at Nominal 200 mm centre-to-centre. The end crest shall be designed for anti - capillary action, to avoid any seepage of water through the lateral overlap. The profile shall have return leg for proper side lap. Coating Specification: Primer Coat: 5-7 microns epoxy primer on both side of sheet. Top Coat: Polyester Top coat 15-18 microns. Color: as approved by Engineer-in-charge Tolerances: As per IS standards: IS: 15961, IS:513, IS:14264 The sheet shall be fixed using self drilling / self tapping screws of size (5.5 x 55 mm) with EPDM seal, complete upto any pitch in horizontal / vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. For Gutter (600 mm overall girth)
12 mm cement plaster of mix : 13.4.2 1:6 (1 cement: 6 coarse sand)
20 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work
Supplying and stacking at site. Good earth
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittingsshall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications,drawings and direction of Engineer-in-charge complete.
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width
( FIRE AND OPS BUILDING )Surface dressing of the ground including removing vegetation and in- equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for PRE-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under floors and apron using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the plinth level: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification.
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. All works upto plinth level
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. All works above plinth level upto floor V level
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form for : Shelves (Cast in situ)
Centering and shuttering including strutting, propping etc. and removal of form for : Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like
Centering and shuttering including strutting, propping etc. and removal of form for : Edges of slabs and breaks in floors and walls Under 20 cm wide
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with common burnt clay Fof class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab upto 0.50 sqm
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab over 0.50 sqm
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 300x10 mm
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 10 x 120 mm
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover
Providing and fixing ball bearing for rolling shutters.
Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer-in- charge, (area of grill to be measured).
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
Providing and fixing Colour Coated Galvalume Trapezoidal profiled sheeting of 0.50 mm Thickness tolerance +/-5% Total Coated Thickness TCT of material 550 Mpa for roofing / cladding application. The Trapezoidal Profiled sheet shall be 28-32 mm in Crest heigfht with 2 Stiffener Ribs with Subtale Square Fluting in the six pans at Nominal 200 mm centre-to-centre. The end crest shall be designed for anti - capillary action, to avoid any seepage of water through the lateral overlap. The profile shall have return leg for proper side lap. Coating Specification: Primer Coat: 5-7 microns epoxy primer on both side of sheet. Top Coat: Polyester Top coat 15-18 microns. Color: as approved by Engineer-in-charge Tolerances: As per IS standards: IS: 15961, IS:513, IS:14264 The sheet shall be fixed using self drilling / self tapping screws of size (5.5 x 55 mm) with EPDM seal, complete upto any pitch in horizontal / vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing Colour Coated Galvalume Trapezoidal profiled sheeting of 0.50 mm Thickness tolerance +/-5% Total Coated Thickness TCT of material 550 Mpa for roofing / cladding application. The Trapezoidal Profiled sheet shall be 28-32 mm in Crest heigfht with 2 Stiffener Ribs with Subtale Square Fluting in the six pans at Nominal 200 mm centre-to-centre. The end crest shall be designed for anti - capillary action, to avoid any seepage of water through the lateral overlap. The profile shall have return leg for proper side lap. Coating Specification: Primer Coat: 5-7 microns epoxy primer on both side of sheet. Top Coat: Polyester Top coat 15-18 microns. Color: as approved by Engineer-in-charge Tolerances: As per IS standards: IS: 15961, IS:513, IS:14264 The sheet shall be fixed using self drilling / self tapping screws of size (5.5 x 55 mm) with EPDM seal, complete upto any pitch in horizontal / vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. For Ridges plain (500-600 mm)
Providing and fixing Colour Coated Galvalume Trapezoidal profiled sheeting of 0.50 mm Thickness tolerance +/-5% Total Coated Thickness TCT of material 550 Mpa for roofing / cladding application. The Trapezoidal Profiled sheet shall be 28-32 mm in Crest heigfht with 2 Stiffener Ribs with Subtale Square Fluting in the six pans at Nominal 200 mm centre-to-centre. The end crest shall be designed for anti - capillary action, to avoid any seepage of water through the lateral overlap. The profile shall have return leg for proper side lap. Coating Specification: Primer Coat: 5-7 microns epoxy primer on both side of sheet. Top Coat: Polyester Top coat 15-18 microns. Color: as approved by Engineer-in-charge Tolerances: As per IS standards: IS: 15961, IS:513, IS:14264 The sheet shall be fixed using self drilling / self tapping screws of size (5.5 x 55 mm) with EPDM seal, complete upto any pitch in horizontal / vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. For Gutter (600 mm overall girth)
12 mm cement plaster of mix : 13.4.2 1:6 (1 cement: 6 coarse sand)
20 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittingsshall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications,drawings and direction of Engineer-in-charge complete.
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin-charge. Pre-laminated particle board with decorative lamination on both sides
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness
Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width
Supplying and stacking at site. Good earth
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore
Providing and fixing toilet paper holder : C.P. brass
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
Providing and fixing of CP brass Health faucet with 8 mm dia 1 mtr. Long PVC tube and wall hook fixed to wall with rawl plug and CP brass screws complete. (Make: Jaquar Cat. No.ALD-CHR-583, Hindware & CERA)
Providing and fixing 1.5 feet long connecting hose with nuts at both ends complete. (Make: Jaquar Cat. No.ALD-803B, Hindware & CERA) for health faucet
Providing and fixing Polyethelene-Aluminium-Polyethelene PE-AL- PE Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes testing of joints complete as per direction of the Engineer-in-charge. INTERNAL WORK - EXPOSED ON WALL 2532 (32 mm OD) pipe
Providing and fixing Polyethelene-Aluminium-Polyethelene PE-AL- PE Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes testing of joints complete as per direction of the Engineer-in-charge. INTERNAL WORK - EXPOSED ON WALL 3240 (40 mm OD) pipe
Providing and fixing Polyethelene-Aluminium- Polyethelene PE-ALPE Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes the costs of cutting chases and including testing of joints complete as per direction of the engineer in charge. Concealed work, including cutting chases and making good the wall etc. 1620 (20 mm OD) pipe
Providing and fixing Polyethelene-Aluminium- Polyethelene PE-ALPE Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes the costs of cutting chases and including testing of joints complete as per direction of the engineer in charge. Concealed work, including cutting chases and making good the wall etc. 2025 (25 mm OD) pipe
Providing and fixing Polyethelene-Aluminium- Polyethelene PE-ALPE Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes the costs of cutting chases and including testing of joints complete as per direction of the engineer in charge. Concealed work, including cutting chases and making good the wall etc. 2532 (32 mm OD) pipe
Providing and fixing Polyethelene-Aluminium- Polyethelene PE-ALPE Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with trenching, refilling and testing of joints complete as per direction of the engineer in charge. External work 2532 (32 mm OD ) pipe
Providing and fixing Polyethelene-Aluminium- Polyethelene PE-ALPE Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with trenching, refilling and testing of joints complete as per direction of the engineer in charge. External work 3240 (40 mm OD ) pipe
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 20 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore
Providing and fixing in position uPVC SWR floor trap conforming to IS:13592 including providing necessary steel support and as per Specification. Making proper connection cutting chase / hole in floors / slabs and bringing the same in proper condition and shape alter placing the trap in right position complete as required. The hopper and trap shall be set in cement concrete mix 1:2:4 complete as required. (P/S trap) Make: Supreme, Ashirvad & Prince (110 x 10 mm)
Providing and fixing uPVC SWR Pipes class B (IS:13592) with all injection moulded fittings complete including jointing with solvent cement including cutting and making good the walls wherever required. (For soil & waste pipes). Nothing extra will be paid for supports (Inside Toilets, Kitchen). Make: Supreme, Ashirvad & Prince 160 mm outer dia
Providing and fixing uPVC SWR Pipes class B (IS:13592) with all injection moulded fittings complete including jointing with solvent cement including cutting and making good the walls wherever required. (For soil & waste pipes). Nothing extra will be paid for supports (Inside Toilets, Kitchen). Make: Supreme, Ashirvad & Prince 110 mm outer dia
Providing and fixing uPVC SWR Pipes class B (IS:13592) with all injection moulded fittings complete including jointing with solvent cement including cutting and making good the walls wherever required. (For soil & waste pipes). Nothing extra will be paid for supports (Inside Toilets, Kitchen). Make: Supreme, Ashirvad & Prince 75 mm outer dia
Providing and fixing 100% stainless steel grating of approved make and quality grade 304 on top of floor trap. The rate includes the cost of all ancillary works and material as required to complete the works. 127 mm (Cat No.-SKSH5,Chilli & Hilti)
Providing, laying & jointing in position uPVC pipe conforming to IS:49851:1988 and suitable for the respective working pressures with all fittings and accessories e.g. couplings, tees, bends, reducers, clamps, screwed adapters, flanged tail pieces etc. jointing as per manufacturers' instructions and making good the wall and floor as required. Make: Supreme, Ashirvad & Prince PVC pipe 110 mm - 6 kg/cm2
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With Sewer bricks conforming to IS : 4885
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 100x100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Supplying and fixing First Aid Hose Reel Reel, wall mounting swinging type complete with drum & bracket of MS construction, spray painted in Post office Red, confirming to IS 884 / 1995 with upto date amendments, complete with the following as required. 36 Meter long 20 mm dia water hose Thermoplastic (Textile reinforced) Type -2 as per IS:12585 25 mm dia ball valve & nozzle Pressure guage Drum and brackets for fixing the equipments on wall. Connection from riser with stop valve (gun metal) & M.S. Pipe.
Providing and fixing M.S. cabinet fabricated from 16 g sheet with full front glass door and locking arrangement duly painted with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade and suitably mounted on a raised platform as required (Approx. 0.6 m x 0.6 M x 0.45 M)
Supply, installation, testing & commissioning Mild Steel black pipe (IS:1239 Part-1) heavy class including cutting, screwing, welding etc. complete with fitting viz. tees elbow, bends, flanges, dead flange, reducers etc. including excavation (upto 1.5 M deep). Rubble soling, sand filling upto 3" above the pipe, back-filling with excavated earth, removal of surplus soil and providing anti-corrosive treatment (coating and wrapping) with 4 mm thick tape and holiday test check as per IS:10221 complete as required. Note: Pipes upto and 40 mm dia shall be standard threaded forged steel fittings joints, above 40 mm shall be standard M.S. fittings with welded joints. Jindal Hissar / TATA 100 mm dia
Supply, installation, testing & commissioning Mild Steel black pipe (IS:1239 Part-1) heavy class including cutting, screwing, welding etc. complete with fitting viz. tees elbow, bends, flanges, dead flange, reducers etc. including excavation (upto 1.5 M deep). Rubble soling, sand filling upto 3" above the pipe, back-filling with excavated earth, removal of surplus soil and providing anti-corrosive treatment (coating and wrapping) with 4 mm thick tape and holiday test check as per IS:10221 complete as required. Note: Pipes upto and 40 mm dia shall be standard threaded forged steel fittings joints, above 40 mm shall be standard M.S. fittings with welded joints. Jindal Hissar / TATA 80 mm dia
Supply, installation, testing & commissioning Mild Steel black pipe (IS:1239 Part-1) heavy class including cutting, screwing, welding etc. complete with fitting viz. tees elbow, bends, flanges, dead flange, reducers etc. including excavation (upto 1.5 M deep). Rubble soling, sand filling upto 3" above the pipe, back-filling with excavated earth, removal of surplus soil and providing anti-corrosive treatment (coating and wrapping) with 4 mm thick tape and holiday test check as per IS:10221 complete as required. Note: Pipes upto and 40 mm dia shall be standard threaded forged steel fittings joints, above 40 mm shall be standard M.S. fittings with welded joints. Jindal Hissar / TATA 25 mm dia
Providing and fixing C.I. butterfly valves PN 1.6 complete with Nitrile liner, SS disc, SS stem, bolts, nuts 1.5 mm thick compressed asbestos gasket companion flanges as per table "E" complete as per IS:13095. Makes: ZOLOTO /NVR/ DEEPAK 100 mm dia
Supply & fixing of ISI (IS:15683) marked Water type stored pressure (stored pressure) type capacity 9 ltrs. With gun-metal cap and nozzle and compete in all respects including initial fill and wall suspension bracket, capacity 9 ltr.
Supply & fixing of ISI marked (IS:15683) Portable fire extinguisher, carbon-dioxide type flat base including valve, discnarge hose of not less than 10 mm dia 1 m long & complete in all respects including initial fill with C02 gas confirming to IS:307-1966 filled to a filling ratio of not more than 0.667 and wall suspension bracket.
Providing and fixing single gunmetal suction collecting heas as per IS:904-1983, hose coupling (draw in / out connection) with female outlet as per 903 complete with 150 mm dia. G.I. Suction pipe (with puddle flange) with a foot valve with strainer complete as per drawings.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group – C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class steel conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class steel conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class steel conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class steel conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class steel conduit as required. 2 X 10 sq. mm + 1 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class steel conduit as required. 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class steel conduit as required. 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 20 mm dia conduit pipe
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 25mm dia conduit pipe
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 32mm dia conduit pipe
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing of call bell / buzzer suitable for single phase,230 volt complete as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 25 amps modular socket outlet and 25 amps modular SP MCB ''C" curve including connection, penting etc as required. (for Geyser & AC)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
Supply and fixing of perforated 2mm thick CRCA sheet steel powder coated cable tray of following sizes complete with bend/tee joints, coupling plate & nuts bolts etc. including providing and fixing of M.S. painted hanger etc. as required. 150mm wide 50 mm depth
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Providing, laying connecting and testing of multi-core telephone armoured/ unarmoured cable of conductor size 0.6mm dia annealed copper conductor PVC insulated PVC sheathed jelly filled (as per DOT specification) cable as required 2 Pair (4 core) unarmoured cable from Tag block to LV box
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable
Supplying and fixing M.S. box with modular type telephone (RJ-11) outlet for Telephone/Intercom complete as required.
Supplying and fixing of 1 or 2 module (75mm x75mm) size GI boxes with modular base and cover plate for modular switches in recess etc complete as required
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way, Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4way Double door
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections,testing and commissioning etc. as required. 40 amps
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 95 sq. Mm and upto 185 Sqmm.
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 95 sq. Mm and upto 185 Sqmm.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 95 sq. Mm and upto 185 Sqmm.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 95 sq. mm and upto 185 sq. mm (clamped with 25/ 40x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 95 sq. mm and upto 185 sq. mm (clamped with 25/ 40x3mm MS flat clamp)
Supply and making end termination with brass double compression gland including providing and crimping of aluminium solderless lugs / ferrules for XLPE armoured power aluminium conductor cable 1.1 KV grade of following sizes:- 4 X 35 sq. mm (32mm)
Supply and making end termination with brass double compression gland including providing and crimping of aluminium solderless lugs / ferrules for XLPE armoured power aluminium conductor cable 1.1 KV grade of following sizes:- 3½ X 120 sq. mm (45mm)
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required.
Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Supplying, installation, testing & commissioning of digital audio amplifier 50 Watt, 25V rms operating at 240 volt AC supply complete as required.
Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required.
Supplly, laying connecting and testing of multi-core telephone armoured/ unarmoured cable of conductor size 0.6mm dia annealed copper conductor PVC insulated PVC sheathed jelly filled (as per DOT specification) cable as required 10 Pair telephone armoured cable
Supplly, fixing connecting and testing of under noted size of solderless telephone tag block Krone make in surface/recess in wall required size of M.S. box with hinged lockable cover duly stove enamel painted. 10 pair tag block
Supplying and fixing M.S. box with modular type (RJ-45) outlet for LAN complete as required.
Supply installation testing and commissioning of Brodband Lan connection complete as required with 10MBPS Speed.
Design, manufacture, supply, installation, testing and commissioning of 2 mm thick MS sheet steel fabricated cubicle type Panel dust and vermin proof complete with hinged and lockable doors . The Sheet Steel shall under go minimum eight tank treatment followed by finishing treatment of powder coating with 70 micron minimum thickness. All the panels shall be floor mounted and dead front construction complete with interconnections. Note:- The panels shall be FRONT operated, with cable entry from the top bottom. Earth bus shall be part of the panel.) (All MCB to be "C" Curve) The following provisions shall be required to be made in the Distribution Panel as detailed below: All live accessible parts shall be shrouded with 1mm thick polycarbonate/3 mm thick FRP sheet and all equipment shall be finger touch proof. The busbar insulation shall be with heat shrinkable sleeves according to the colour code. SMC shrouds and busbar supports shall be used. All MCCB door handle shall be interlocked and lockable in OFF position. Galvanised hardware with zinc passivation shall be used in fabrication of Switchboards. Suitable Aluminium earth bus to be provided throughout the length of Switchboards. All indication lamps / illuminated push buttons shall be LED type. Coil of all motor starters shall be fed from 440 V / 230 V Control Transformer. 2A SP MCBs shall be used as backup protections. All MCCBs shall be variable plug setting type with thermal magnetic Ics = 100% Icu & rotary handle. All control& power wiring shall be broughtout upto the cable alley in the terminal blocks.An approval shall be taken for each panel before manufacturing. Provision of one 6/16 amp socket & compartment lighting for each vertical section of main panel.All breaking Capacity for MCCB to be Ics=100%Icu. All MCB to be C Curve MDB-1 Incoming: 1 no. of 250 Amp FP MCCB of 16 KA breaking capacity & Trip setting as required. Metering for incoming: Digital Multifunction meter (MFM-4) with RS-485 communication port for measurement of PF, V, A & Hz , equivalent to EM6459, with CT as required. Phase indicating lamps RYB with 2 Amps SP MCB back up. BUSBAR Electrolytic high conductivity aluminium three phase and neutral busbars rated at 300 amps, 16KA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. Current density of Bus Bar to be 1.2 sq.mm / amp. OUTGOINGS 3 nos. 63 Amps 10 kA 440 volt FP MCB .1 nos. 100 Amps 16 kA 440 volt FP MCCB along with 100A FP Contactor. 1 nos. 63 Amps 16 kA 440 volt FP MCCB. 3 nos. 40 Amps 10 kA 440 volt FP MCB . 1 nos. 40 Amps 10 kA 440 volt DP MCB . MDB describe as avove complete in all repect.
Supply and fixing of 2mm thick CRCA sheet steel powder coated Raceway of following sizes complete with bend/tee joints, coupling plate & nuts bolts etc. including providing and fixing of M.S. painted hanger etc. as required. 150mm wide 50 mm depth
Supplying, fixing, testing and commissioning of surface mounted luminaire of 34W LED 600x600mm of 5700K suitable for operation on 230 volt 50 Hz,Single Phase AC supply with all accessories complete for ceiling. Havells Cat No: LHEWEBP6IN1W034 or equivalent make.
Supply, Installation, testing & Commissioning of recessed Mounted circular 12W LED downlighter with CRCA / pressure diecast aluminimum heat sink & white finish polycarbonate diffuser , complete with electronic LED driver, efficacy better than 90 lumens / watt with CRI> 80 including making suitable arrangement for fixing on false ceiling & connection complete as required.
Supply, Installation, testing & Commissioning of 8W LED Mirror Light complete as required.
Supplying, fixing, testing and commissioning of wall/ ceiling mounted luminaire of 21W LED, 1200mm Batten light suitable for operation on 230 volt 50 Hz,Single Phase AC supply with all accessories complete as required
Supplying, fixing, testing and commissioning of following size exhaust/ fresh air fan complete with gravity louver and connection with 3 core flexible wire as required. 300mm 1400 RPM Heavy duty Metal exhaust fan Havells make model: Turbo Force SP or equivalent preferred makes.
Supplying, erection, connecting, testing and commissioning of 1200mm sweep ceiling fan complete with GI Fan Box, blades, down rod, shackle insulator, canopy etc. including providing of electronic step regulator with faceplate matching the existing modular switches as required. (Similar to Havells-Pacer)
Supply, unloading, installation at Ground Floor, testing & commissiong of micro processor / DSP controlled 5 KVA UPS, IGBT based rectifier to achieve THDI < 5% and input power factor of greater than 0.95 at 50% loading. True Online Double Conversion (VFI as per IEC 62040-3) UPS using PWM IGBT technology , 1 Phase input and 1 phase 230 V output UPS system; and each comprising of the following:125% rated Rectifier cum charger unit +100% rated Invertor, Integrated in UPS module100% rated External Galvanic isolation transformers of K-13 Delta/Zigzag type for isolation of input neutral with output neutral ,to be installed after UPS as shown in drawing enclosed 100% rated Inbuilt static switch at the invertor output + 2 Nos. 100% rated Inbuilt static switches at the static bypass line 100% rated Inbuilt Maintenance Bypass. 100% rated moulded case battery circuit breaker having Ithermal, Imagnetic and Automatic U/V trip mechanics.Web-enabled Monitoring and Management through SNMP protocols for multi-OS environments.Supplying, unloading, installation at basement, testing and commissioning of Lead Acid sealed maintenance free batteries for 5 KVA UPS system, for providing 15 minutes backup to 5 KVA UPS for full load. The bank of batteries shall comprise required Nos of batteries complete as required. Battery sizing calculation are to be submitted for approval Supply, unloading, installation at basement, testing & commissioning of matching cabinet/open racks to house SMF batteries for 5 KVA UPS system along with interconnecting links, MCB etc. complete as required & as per specifications. Supply, laying, testing & commissioning of flexible single core copper cable of Finolex / Skyline / Havell's / Nyvin make for interconnections between UPS to UPS, UPS to batteries, UPS to Isolation Transformer, complete as required for 5 KVA UPS,including providing Battery circuit breakers as required.Supply, installation, testing and commissioning of UPS monitoring software suitable for RJ-45 communication and capable of giving pop up messages for all alarms received from UPS. It shall be capable of the following:-Giving notifications like e-mail, paging notification, broadcast notification, battery replacement notification, run event-based scripts.Event logging, data logging and action logging (with date, time, description of fault and event). Run the battery diagnostic test.Automated unattended shutdown of computers. Local notification through audible alarm.Software should support Microsoft Windows NT / 2000 / Server, 2003/XP, AIX, HP-UX, Sun Solaris, Linux, Novell Netware UPS describe as avove complete in all repect.
Providing and fixing of self illuminated / auto glow "EXIT" signs printed on photoluminescent sheet containing self illuminated base chemical, of appropriate size not less than 400 x 150 mm, suspended from ceiling or fixed to the walls with accessories as required and as directed at site.
Supply testing of under noted sizes of Aluminium conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables conforming to relevant IS code. 3 x 2.5 sq.mm Al. Armoured
Supply testing of under noted sizes of Aluminium conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables conforming to relevant IS code. 4 x 35 sq.mm Al. Armoured
Supply testing of under noted sizes of Aluminium conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables conforming to relevant IS code. 3.5 x 120 sq.mm Al. Armoured
Supply testing of under noted sizes of Aluminium conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables conforming to relevant IS code. 2C x 10 sq.mm Al. Armoured
Supply, installation, testing and commissioning of colour Dome camera with 2 Megapixel along with suitable lens, stainles steel brush finish plate etc. complete as required & as per specifications. (For Basement Lift Lobby and Entrance Hall & Terrace Lobby)
Supply, installation, testing and commissioning of 1Professional DVR with 16 Video Inputs, H.264 Compression - D1 Display Resolution with 2.5TB HDD, Expandable up to 8 TB. Total recording frames @ 400 fps. Recording based on Continuous, Motion, Scheduled or alarm, Remote backup through TCP/IP,HTTP Networkable, backup by USB/DVDWR, Client software included, POS Transaction data recording with image. Supplied with Licensed OS, keyboard & mouse. complete as required and as per specifications. The DVR shall be integrated with Access control system. (Along with 2 nos. 4 TB.)
40" Full HD LED Professional Display for Monitoring with mounting accessories.
Supply, installation, testing and commissioning of ISI mark Water Cooler of 150Ltr. Tank and 150Ltr. Cooling capacity per hour in fully stainless steel body complete as required.
Supplying, errection, testing & commissioning of submersible centrifugal pump set suitable to give discharge of 7.5 cubic mtr/hr. (1HP) at a head of 15 mtr complete with Auto starter and 10 meter suitable size of B class GI pipe along with submersible cable of 3x2.5sq.mm size 15mtr in length from starter to motor , link chain with hook of suitable size for hanging the pump in underground reservoir and complete as required.
Supply, installation, testing and commissioning of Hi-wall Split Unit (5 Star Rating) with rotary compressor & cordless control of following capacity with wall/floor mounted outdoor unit stand. 2.0 TR Air-Cooled Split Unit ( Heating + Cooling)
Supply, installation, testing and commissioning of additional refrigerant piping (two lengths) duly insulated with 25 mm for indoor application and 38 mm for outdoor application closed cell nitrile rubber of density 60+/-10% Kg/m3 to interconnect indoor & outdoor units for each circuit. For 2.0 TR Unit
Supply, installation, testing & commissioning of PVC Hard drain piping with fittings, valves & insulation with 13 mm for indoor application closed cell nitrile rubber of density 60+/-10% Kg/m3. 32 mm Dia. of pipe, PVC Hard Pipe
(UG TANK) Surface dressing of the ground including removing vegetation and in- equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. All works upto plinth level
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Extra for providing richer mixes at all floor levels. Providing M-30 grade concrete instead of M-25 grade BMC/ RMC. (Note:- Cement content considered in M-30 is @340 kg/cum)
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform
Edges of slabs and breaks in floors and walls Under 20 cm wide
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc.,complete.
12 mm cement plaster of mix : 13.4.2 1:6 (1 cement: 6 coarse sand)
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats
Supplying and stacking at site. Good earth
Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of : (i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. (ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions. (iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer. Using rough kota stone.
Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge : Using rough Kota stone
Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete : Dumb bell with central bulb (180 mm wide, 8 mm thick)
Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
Supplying and Fixing of Padler Flanges of 100 mm Dia as per Approved Design as directed by Engineer-in-charge:
(SEPTIC TANK AND SOAK PIT )Surface dressing of the ground including removing vegetation and in- equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. All works upto plinth level
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form for : Edges of slabs and breaks in floors and walls Under 20 cm wide
Supplying and stacking at site. Good earth
Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of : (i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. (ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions. (iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer. Using rough kota stone.
Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge : Using rough Kota stone
Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete : Dumb bell with central bulb (180 mm wide, 8 mm thick)
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
( PERIMETER FENCING) Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All works upto plinth level: 1:2:4 (1 cement : 2 coarse sand (Zone III) : 4 graded stone aggregate 20 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All works upto plinth level: 1:4:8 (1 cement : 4 coarse sand (Zone III) : 8 graded stone aggregate 40 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form for all height Foundation,footing,bases of columns, etc. for mass concrete
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed red oxide zinc chromatic on steel/ iron works having VOC content less than 250 grams/litre.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. Complete.
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia 4 mm
(CHAIN LINK FENCING AND GATE) Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed red oxide-zinc chromatic on steel / iron works having VOC content less than 50 grams / litre.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 13.61.1 Two or more coats on new work
Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete.
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All works upto plinth level
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All works above plinth level upto floor V level
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts
Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
( EXTERNAL ELECTRICAL WORK/CCTV/SECURITY INSTALLATION) Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 95 sq. Mm and upto 185 Sqmm.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 95 sq. Mm and upto 185 Sqmm.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 95 sq. mm and upto 185 sq. mm (clamped with 25/ 40x3mm MS flat clamp)
Supply and making end termination with brass double compression gland including providing and crimping of aluminium solderless lugs / ferrules for XLPE armoured power aluminium conductor cable 1.1 KV grade of following sizes:- 2C x 10 sq.mm
Supply and making end termination with brass double compression gland including providing and crimping of aluminium solderless lugs / ferrules for XLPE armoured power aluminium conductor cable 1.1 KV grade of following sizes:- 2C x 16 sq.mm
Supply and making end termination with brass double compression gland including providing and crimping of aluminium solderless lugs / ferrules for XLPE armoured power aluminium conductor cable 1.1 KV grade of following sizes:- 4 x 10 sq.mm
Supply and making end termination with brass double compression gland including providing and crimping of aluminium solderless lugs / ferrules for XLPE armoured power aluminium conductor cable 1.1 KV grade of following sizes:- 4C x 25 sq.mm
Supply and making end termination with brass double compression gland including providing and crimping of aluminium solderless lugs / ferrules for XLPE armoured power aluminium conductor cable 1.1 KV grade of following sizes:- 3.5 x 70 sq.mm
Supply and making end termination with brass double compression gland including providing and crimping of aluminium solderless lugs / ferrules for XLPE armoured power aluminium conductor cable 1.1 KV grade of following sizes:- 3½ X 120 sq. mm (45mm)
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required 100 mm dia
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required 150 mm dia
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 120 sq. mm
supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 3Cx120 Sq.mm.
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 3Cx120 Sq.mm.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Supply testing of under noted sizes of Aluminium conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables conforming to relevant IS code. 4 x 10 sq.mm Al. Armoured
Supply testing of under noted sizes of Aluminium conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables conforming to relevant IS code. 2C x 10 sq.mm Al. Armoured
Supply testing of under noted sizes of Aluminium conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables conforming to relevant IS code. 2C x 16 sq.mm Al. Armoured
Supply testing of under noted sizes of Aluminium conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables conforming to relevant IS code. 4C x 25 sq.mm Al. Armoured
Supply testing of under noted sizes of Aluminium conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables conforming to relevant IS code. 3.5C x 50 sq.mm Al. Armoured
Supply testing of under noted sizes of Aluminium conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables conforming to relevant IS code. 3.5C x 70 sq.mm Al. Armoured
Supplying & Testing of following sizes XLPE, 11 KV earthed armoured cable confirming to relevent IS code. 3Cx120 Sq.mm.
Supply, Installation, Testing and Commissioning of 4 MP bullet camera , ONVIF profile S & G ,UL , CE , FCC Certified ,1/2.8” Progressive Scan CMOS ,2.8 mm to 12 mm motorized varifocal lens ,min illumination : 0.05 Lux @ (F1.2,AGC ON), 0 Lux with IR , Shutter speed : 1 / 5s ~ 1 / 100,000 s , 90 dB WDR , SD card support , Alarm trigger - 1 input / 1 output , Video Compression : H.265 ,H.264 , frame rate : 30fps @ 3MP ,Edge analytics : line crossing , perimeter intrusion ,Face detection , cross counting , stationary object , In built IR LED , IR Distance upto 60 meters , IP 66 , POE.
Supply, installation, testing and commissioning of 1Professional DVR with 16 Video Inputs, H.264 Compression - D1 Display Resolution with 2.5TB HDD, Expandable up to 8 TB. Total recording frames @ 400 fps. Recording based on Continuous, Motion, Scheduled or alarm, Remote backup through TCP/IP,HTTP Networkable, backup by USB/DVDWR, Client software included, POS Transaction data recording with image. Supplied with Licensed OS, keyboard & mouse. complete as required and as per specifications. The DVR shall be integrated with Access control system. (Along with 2 nos. 4 TB.)
1. Supply, Installation, Testing and Commissioning of 16M high mast shaft in two section suitable for 47 m/sec wind speed along with head frame, luminaires carriage suitable for 08 luminaires in symmetrical arrangement and other accessories manufactured in factory. Including raising lowering system comprising double drum winch, 5mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightning finial. (Wiring material from JB to individual luminaire Included) and with foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template including suitable foundation with provision of cable entryalso with LED type single dome aviation obstruction light.
Supply, Installation, Testing and Commissioning of LED flood light of 200W LED suitable for high Mast Operation complete as required.
Supply, Installation, Testing and Commissioning of outdoor stand mounted feeder pillar with 32A TPN MCB incomer, single dial time switch, 25A TP contactor for the automatic switching of luminaries, power tool control with 2 no 9A contactors and raise lower push button, Incoming 4X10 sq. mm and out going 2.5 sq. mm terminals.
Supply, Installation, Testing and Commissioning of 4mtr high hot dip galvanised octagonal poles with 130mm bottom A/F & 70mm top A/F made up of 3mm thk. HT sheet alongwith base plate of size 200X200X12mm thk. (Without Bracket)
Supply, Installation, Testing and Commissioning of 4Nos of M16X450 long 'J' type EN 8 grade foundation bolts along with template
Supply, Installation, Testing and Commissioning of 7mtr high hot dip galvanised octagonal poles with 130mm bottom A/F & 70mm top A/F made up of 3mm thk. HT sheet alongwith base plate of size 200X200X12mm thk. (Without Bracket)
Supply, Installation, Testing and Commissioning of 4 Nos of M20X600 long 'J' type EN 8 grade foundation bolts along with template
Supply, Installation, Testing and Commissioning of 1mtr long hot dip galvanised Single arm special bracket (Model: Type-5) cross arm made up of GI pipe suitable to mount on pole having top 70mm A/F. Model: Type 5
Supply, Installation, Testing and Commissioning of LED Street Light of 30 W Light Fixture.
Supply, Installation, Testing and Commissioning of 25 W Gate LED Light suitable for Coloumn Mount and suitable for 220Volt opetration complete with wiring etc as required.
SUPPLY OF 160 KVA UNITISED SUB-STATION 1. Design, manufacture, testing at works, supply of Compact unitized Substation, outdoor plinth mounted type, comprising following components interconnected with one another, including required interconnection with cable/ busbar and internal earthing connections complete as required and as per specifications. 11KV Compact secondary substation outdoor type designed for natural cooling having type tested equipment comprising distribution transformer and SF6 insulated compact switchgear enclosed in robotically sealed laser sealed/welded stainless steel tank,low voltage switchboard,interconnection between HT switchgear and transformer using cables and transformer to LT switchgear using Al busbars/cables,factory built ready for connection type,internal earthing factory completed and other associated equipment etc. complete as required conforming to detailed specifications. The enclosure shall have modular construction using G.I sheets and shall be painted with polyurethane paint from the exterior.The enclosure for HT & LT switchgear shall be provided with IP54 ingress protection.The transformer compartment will have IP23 ingress protection.The transformer used shall be specially designed for low losses and hermatically sealed with corrugated tank.The components of Compact substation shall be as per details below: I. H.T. PANEL (11KV) 1 way 11KV,(V+M)3 Phase ,50Hz,3 wire,floor mounted ,non extensible, having hinged arc proof cable doors,breaking capacity 21KA SF6 insulated compact switchgear enclosed in stainless steel tank having IP67 degree of protection consisting of following:- i. 1 No. 11KV, 630Amps. Tee-off spring assisted type Vacuum circuit breaker unit with self-actuating electronic over current and earth fault relay ,fitted with fixed type voltage indicator device as per IEC 61958 and ring core type protection current transformer along with LV compartment with A ,PF ,Bucholtz Relay,auxiliary realys for WTI (Winding Temperature Indication), 4 window annunciation panel and TVM. ii. Air insulated metering panel connected along with above unit, 20KA, 630A having potential transformer,connected jumpers/busbars ,LV compartment to incorporate voltmeter as per requirement, including providing Voltmeter, Ammeter, Electronic Trivector Meter with MDI, space Heater with Thermostat. II. TRANSFORMER (Dry Type) WITH OFF LOAD TAP CHANGER 1No. 11KV/433V, 160 KVA three phase, 50Hz, DYn11, Off load tap changer +5% to -10% in steps of 2.5%, mounted inside compact substation enclosure, hermetically sealed,corrugated wall design transformer with Cu winding and standard fittings. As per IS-2026 As Amended up to date expect losses III. BUS BARS: Electrolytic high conductivity Aluminium three phase and neutral busbars rated at 400 Amps, 25KA. Bus bars shall be colour coded and insulated by heat shrinkable sleaves & clip on shrouds for joints. The current density of Bus bar shall be 1.2 sq.mm./amp. IV. LT OUTGOINGS Two Incomer with 433V LT feeder panel having 320A 4P manually operated MCCB, 36KA with microprocessor based O/L, S/C and E/F protection along with phase indication lamps & protection MCB, space Heater & Thermostat including 1 No. 45 KVAR (1 Nos. 20Kvar, 2 Nos. 10Kvar & 1No. 5Kvar), MPPH Capacitor Bank, with 125A TP MCCB, 25 KA service breaking capacity, for direct operation, along with MFM & Phase Indication lamp. Unit Substation comprising I, II, III & IV as described above and as per specifications.
EXTERNAL LIGHTING PANEL INCOMER : 1Nos. 80A, 415V, Ics= 16kA, FP MCCB with variable E/F, O/L and S/C releases with set of cast resin C.T.'s of 80A along with 1 set of timer switch with suitable rating of contactor for Automatic Operation. BUS BARS: Electrolytic high conductivity aluminium three phase and neutral busbars rated at 100 amps, 16KA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. OUT GOING: 2 Nos. 32A, FP MCB of 10kA Breaking Capacity 3 Nos. 20A, DP MCB of 10kA Breaking Capacity Complete panel described as above
Supply, Installation, testing and commissioning of 100 AH capacity, 24V DC maintenance free SMF Batteries in fully charged condition, including painted MS stand & spill proof plastic trays etc. complete as required as per specifications. Along with ii) & Battery Charger Unit with provisions of "Boost Charging" and "Float Charging", suitable for 240V, single phase, AC, 50Hz supply system & 24V DC including providing required MCB for DC supply distribution to panel complete as required.
Supply and fixing in position the approved "shock treatment charts" framed in teak wood frame and covered with glass in front as required in two languages (Hindi & English)
Supply & Laying of non skid Electro mat 1 mtr wide and 3.0 mm thick 11 KV grade conforming to IS 15652 as required including cutting to required length complete as required. (for HT Panel)
Supply of fire buckets 5 nos. 15 litre capacity duly filled with fine sand and fixed on an angle iron frame as per requirement of local authorities. The fire buckets shall be painted red from outside and white from inside, including lettered as FIRE with white colour with extra handle at bottom.
Supply & Laying of non skid Electro mat 1mtr wide and 2.0 mm thick 1.1KV grade IS 15652 as required including cutting to required length complete as required.
Supply of standard first aid box as approved by Indian red cross society/ St.John Ambulance Brigade and conforming to IS 2217-1963.
Design, supply at site, installation, testing & commissioning of 3-phase, 415 volt, 1500 RPM, 50 HZ, Diesel generator set of 82.5 KVA at 0.8 pf lagging diesel engine alternator set mounted on common base frame in outdoor type acoustic enclosure with built in fuel tank of required capacity along with additional day tank capacity of 990 litres including fuel piping, level indicator and valves as required, with AMF Panel, battery, batter charger, return fuel cooler, anti vibration mounting pads including residential silencer, engine alternator, pcc based auto start & synchronization set, safeties with accessories and control cabling for AMF panel up to 50mtr. length as per specification complete as required. Diesel engine shall conform to IS:10000 and alternator shall be self excited complete with AVR to IS:4722.
Supplying and fixing of undernoted 'B' class MS pipe for DG exhaust complete with bends, elbow, flanges etc. as required. 125 mm dia pipe
Supply and fixing of 50mm thick compressed mineral wool insulation (Rock wool) for D.G. exhaust pipe with 22 gauge aluminium sheet cladding etc. as required for the under mentioned dia pipe. 125 mm dia pipe
Fabrication of supports for exhaust pipe, fuel pipe or for any other purpose out of M.S. structural steel including supplying and applying of enamel paint of approved shade after one coat of steel primer of reputed company.
Supply installation Testing & Commissioning of Boom Barrier of 4 Mtr. length of Boom arms. Galvanised and RAL Painted with buil in control panel with intensive use. Manual open / close buttons and automatic closing IR device complete with ground loop detection board (for entrance and exit to the main building),100% duty cycle.High intensive use DC barrier. 180-200Nm Operating Torque for. 2 sec Open/close time . Motor current draw : 12A. Max Motor Power: 300W.Max Opening : 90 degree.IP54. Inter-changeable barrier( left to right and vice versa). Ampereomatic feature for high safety in case of failure of safety device. complete as required as per given technical specification.
Supply installation testing & commissioning of portable spike barieer Tyre /Killer suitable to work on manual operation .The main frame is made of 6mm thick flat aluminum strip which made it corrosion resistant,strong and light in weight for easy portability & long durability. Other details are as below, a. Portable Tyre Killer - 4 Mtr. b. Edge of Spike - 10mm, c. Height of Spike - 60mm, d. No. of Spikes - 85 Nos. e. Total Weight : 7 Kg. (Approx.) f. No. of Wheels in Packing Box - Two etc.
Ramesh Kr. Agarwalla
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .