Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.9 LAccepted-AOC 1260 GANGAPUR GROUND FLOOR MANDIRTALA DUTTAPUKUR NORTH 24 PARGANAS WEST BENGAL 743248 UDYAM WB 14 0074262 | 24 PARAGANAS NORTH | WEST BENGAL | 743248 | ₹10.9 L | L1 | Accepted-AOC AOC ISSUED |
| 2 | L2₹11.7 LRejected-Finance KANKARDANGA | ₹11.7 L | L2 | Rejected-Finance That the bid
is not L1 |
| 3 | L3₹11.8 LRejected-Finance 197 4 KANTADANGA ROAD P O FINGAPARA KANKINARA NORTH 24 PARGANAS PIN 743129 | KANKINARA | NORTH 24 PARGANAS | WEST BENGAL | 743129 | ₹11.8 L | L3 | Rejected-Finance That the bid
is not L1 |
Tender Value
₹11.8 L
EMD Value
₹23,660
Closing Date
25 Sept 2024, 3:00 pmClosed
EE-II KNHED PWDte.
Office of The Executive Engineer Kolkata North Health Electrical Division, P.W.Dte. KIT Annex Building, 4th Floor, India Exch. Place Extn., Kolkata 700073
Repair Renovation of Compound Light (CB Building, DHB Building, NOPD Building, Cobalt Building Premices) Repair Renovation of Central Garden, Beside of CB Building for overall Safety Security improvement at MCH, Kolkata-EI and AC Work
2024_WBPWD_752004_1
WBPWD/EE-II/KNHED/NIQ-73/24-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
10 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹23,660
5 Nov 2024
16 Sept 2024
27 Sept 2024
16 Sept 2024
25 Sept 2024
16 Sept 2024
Amount
E.I work Dismentling the existing light fittings including necy. Itner connections with PVC insulated copper wire.
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Make: R.R Kable / Polycab / Havells/Glostar/KEI) in 20mm/25mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required Vide page no E 14 Item no 1.a a. 2 x 2.5 sqmm + 1 x 1.5sqmm
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. as per G S Vide page no F5 Item no 9 a. 2.5sqmm
b. 4.0sqmm
c. 6.0 sqmm
d. 10.0sqmm
e. 16.0sqmm
VTPNDB,HTPNDB,SPNDB & others Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Make-Legrand/LK/Schneider/ABB/Siemens) 2+12 way as to GS Vide page no D-9 item no 13
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Make-Legrand/LK/Schneider/ABB/Siemens) , 6 way, as to GS Vide page no D-10 item no 14
Supplying and fixing 240/415 V Isolator on din rail of existing DBs and necessary connection (Make-Legrand/LK/Schneider/ ABB/Siemens) , as to GS. Vide page no D-5 item no 6 a. 415V,63A FP for PBDB
b. 240 V, 40A DP for LBDB
Supplying and fixing 240/415V, MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Make-Legrand/LK/Schneider/ABB/Siemens) , as to GS. Vide page no D-6 item no 7 a. 6A - 32A SP MCB for PBDB & LBDB
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment (Make-Legrand/LK/Schneider/ ABB/Siemens) as to GS Vide page no D-12 item no 16 a. 6 way HTPNDB
Supply of cables :--- Supplying and Delivery of following sizes Al. armoured PVC/XLPE cable (make-- Havells/Gloster/KEI/Polycab/RR kable) as mentioned below : a. 4 core 25 sqmm (from VTPN to PDB)
b. 4 core 6 sqmm
c. 2 core 6 sqmm
Laying of cables :--- Laying of cable of following sizes on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting as mentioned below as to GS:- Vide page no F 1 Item no 2 a. 4 core 25 sqmm
b. 4 core 6 sqmm
c. 2 core 6 sqmm
Laying of cable of following sizes on existing cable tray and binding with suitable size GI wire incl. with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, as mentioned below as to GS:- Vide page no F 3 Item no 6 a. 4 core 25 sqmm
Laying of one no cables upto 35 sqmm in underground trench in single tier formation (horizontal), the trench size : 460 mm x 760 mm average depth, with brick protection on the top of each cable 8 (eight) Nos. bricks per Mtr including filling the space between the bricks and cables and also trench to be filled up with shifted soil, levelling up and restoring surface duly rammed, as per GS. Vide page no F 2 Item no 1a a. 4 core 6 sqmm
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below:(Vide page no F-4 item no 7) a. 4 core 25 sqmm cable
b. 4 core 6 sqmm cable
c. 2 core 6 sqmm cable
Finishing the end of following XLPE/PVC armoured cable by crimping method including supplying and fixing solderless socket(Dowels make),tapes,anticorrosive paste and jointing materials as per GS. (Vide page no F-5 item no 8b) a. 4 core 25 sqmm cable
b. 4 core 6 sqmm cable
c. 2 core 6 sqmm cable
S&F 40 mm dia medium gauge GI Pipe (ISI-Medium) Protection with necessary fittings and jointing metarials as reqd, as per GS. (Vide page no F-6 item no 11)
Supply of Light fittings Compound Lighting Arrangement :: Supply of 230V 5700 K 21000lm Luminous Efficacy (rated) (Nom) 140 lm/W Aluminum die cast IP66 [Dust penetration-protected, jet-proof]LED Street Light Luminaries complete with all accessories. (corrosponding to Mk. Philips, Cat No. BRP504 LED 210 CW R3C PSU S1/ equivalent of Havells/ Wipro).
Supply & fixing 20-24W outdoor type LED luminaire with pressure dia cast aluminium housing with IP 65 protection (Make- Philips/equivalent of Havells/ Wipro) incl 20 W LED lamp incl interction as per direction of EIC. [NS]
Supply & fixing 40-45W outdoor type LED luminaire with pressure dia cast aluminium housing with IP 65 protection (Make- Philips/equivalent of Havells/ Wipro) incl 20 W LED lamp incl interction as per direction of EIC. [NS]
Supply & fixing of 230 Volt 45 watt LED outdoor type light fittings ( Make - Crompton Greaves/, Cat No. TRP-417-45-57-SL-LM-NBK/ equivalent of PHILIPS/Havells/ Wipro ) [NS]
Supply & fixing outdoor type LED luminaire with pressure dia cast aluminium housing with IP 65 protection (Make- CROMPTON 10W-LBLSN-10-CDL/WW LIARA/equivalent of PHILIPS/Havells/ Wipro) incl 10 W LED lamp incl interction as per direction of EIC. [NS]
Earthing :--- Supplying & fixing earth busbar including connecting the equipments of galvanized ( hot dip) MS flat 25 mm * 6 mm on wall as per G.S. [G-2/4(a)]
Earthing with 50 mm dia GI pipe 3.64mm thick * 3.04 mts long with ISI Medium GI pipe as per GS. [ G-1/2(b)]
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. a. Solid GI wire 6 SWG [G-2/5(a)]
Excavation of soil for installation of Earth Electrode and filling & ramming.For Morrum Soil. [ 1(b)/G-1 ]
Miscelleneous :--- Providing CC (6:3:1) muffing 450x450x600 mm in size or equivalent size of cylindrical muffing above ground level around the pole base complete with 3 mm thick neatly finished cement plaster all round after dismantling the unserviceable muffing if any incl. fixing only loop box if necessary. [I-1/13] a. Without Loop Box
Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting. [I-2/16a] a. 200 x 150 x 100mm
S & Erection of PVC water proof loop Box (Mk. Syntex code; GSMB 2520) of size 8" x 10" with 100A, 4 pole stud type terminal block, 15A kitkat fuse & NL, to be fixed on bakelite/porcelin insulator, having hinged PVC cover 4mm thick, rubber gasket lining, mechanical locking arrangement to be concealed in wall as per direction of EIC.
Supply & Installation 3 Ph timer unit for Compound Light consisting of the following ; 1. Double door SPNDB Box (2+14 Way) with door locking arrangement (LK / ABB) ----------------- 1 no. 2. 22A, 230V, 3 Pole Contactor Unit (Make - ABB / LK) - 1 no. 3. Digital (RTC) time switch ( Make - ABB / LK) - 1 no. 4. TP MCB (20 Amp, "C" Curve) (Make - ABB/LK) - 1 no. 5. By pass Toggle Switch - 1 no. 6. Proper interconnection arrangement with 4 (for Ph) & 2.5 (for N & E) sq.mm. PVC FR copper wire (Make- Havells / Polycab) with proper socketing
Supplying and fixing Sheet steel Main Switches on angle iron frame on wall a. 60/63 A (LK/Schneider/ABB/Siemens) [D-1/1(b)]
Supplying and fixing 415V, FP Change over (LK/Schneider/ABB/Siemens) with sheet steel enclosure on angle iron frame on wall with nuts bolts etc as per rating as per GS Vide page no D 2 Item no 3.a a. 63A (For Dual source provision)
(Rate should be quotated including all taxes and duties and GST)
SASTIK ENTERPRISE (BID ID -5630623)
M/S R. K. ENTERPRISE (BID ID -5630610)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].