Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹37.5 L
EMD Value
₹75,100
Closing Date
3 Nov 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (South) Meerut Cantt
Garrison Engineer (South) Meerut Cantt The Mall Road Meerut Cantt Distt Meerut-250001(UP)
SPL REPAIR OF BLDG NO E-57 OR LIVING ACCN AT 22 RAPID (S) ORD UNIT UNDER AGE B/R-IV AND AGE E/M-II OF GE (SOUTH) MEERUT CANTT
2025_MES_733153_1
GE/MRT/S/8275/2025-2026
Open Tender
Civil Works
Item Rate
180 days
Meerut Cantt
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (South) Meerut
₹75,100
Yes
Garrison Engineer (South) Meerut Cantt
30 Sept 2025
30 Sept 2025
10 Nov 2025
30 Sept 2025
3 Nov 2025
15 Oct 2025
8 Oct 2025
Demolition of brick work or stone/boulder masonary built in cement mortar incl all quoins arches pillars etc complete all as specified & directed.
M & L brick work with sub class fly ash bricks straight or curved on plan exc 6 m mean radis built in CM 1:6 complete all as specified & directed.
Demolition of cement concrete (unreinforced) in ground floor and pavings n exc 15 cm thick ( above or below GL) complete all as specified & directed.
S & F Steel window box type using ERW 'P' section comprising double frame for gauged and glazed skeleton shutter jointed internally with flat iron 40x3mm complete including hinges, handle tower bolts stops, lugs etc of suitable size as directed by Engineer-in-Charge. Note (i) For the purpose of measurement and payment double shutter with frame shall be considered as one unit (ii) Unit rate quoted against this item shall also include the iron mangries shown on drgs (iii) guard bars, glazing and wire mesh shall be measured and paid for separately complete all as specified & directed.
Per 1000 No's
M&L preparation of new or previously untreated steel surface of any description over 10cm width or girth and applying two coat of synthetic enamel (by spraying) complete all as specified & directed.
Taking down of cement plaster of any description from brick or stone wall etc. including raking out of joints, hacking for key, scrubbing down with water etc complete all as specified & directed.
M & L 15 mm thick rendering in CM 1:6 on fair faces of brick or concrete surfaces finished even and fair complete all as specified & directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded stone agg) 25 mm thick for Sub base flooring complete all as specified & directed.
M&L PCC 1:3:6 type C-0 (using 12.5 mm greded agg) for hold fast pressed steel frame etc complete all as specified & directed.
M&L Framed work such as grills, angle grating etc. with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, railings and similar work confirming to Fe-410-O or Fe-310-O, complete all as specified & directed.
S&F in repair rolled mild steel as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc including notching, drilling, fittings, reveting and / or welding or connecting with bolts and nuts (including revets or bolts and nuts), providing fittings angle cleats, fish plates, gusset plates etc, also for wedging, plumbing, truing up and fixing conf to Fe-410-W (Gde-E-250) quality A complete all as specified and directed
M&L 75mm thick PCC 1:3:6 type C-2 ( 40 mm graded aggrgate) as in plinth protection, path etc finished the surface even & fair complete all as specified & directed.
M&L for demolition of RCC as in Roofs, floors (other than ground floors), beams, staircases, landing,chajjas and similar suspended work complete all as specified and directed
S&F Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) including neccesaary bolts,nuts and securing screws complete all as speficied and directed
Dismantling asbestos cement (Corrugated or Semi corrugated ) sheet including ridge as in roof covering complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding/ridges to wall, fixed with self tapping screws in ridges including taking down old shee complete all as specified & directed.
S&F Mild steel flat iron as in wind ties including cutting drilling holes and securing bolts confirming to FE 410-0 of 310-0 complete all as specified & directed.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding/ridges to wall, fixed with self tapping screws in ridges including taking down old sheet complete all as specified & directed.
Supply & fix galvanized mild steel wire cloth with 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanized wire staples complete all as specified & directed.
Materials & labour for prepration of newely plastered surface and finishing the surfaces of wall with wall putty and applying two coat of Oil Bound distemper over one coat of wall putty of, any colour, complete all as specified & directed.
Material and labour for preparation of old surfaces finishing of walls and applying two coats of oil bound distemper over a coat of putty complete all as specified & directed.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons laid and pointed in any mortor etc complete all as specified & directed.
M&L Machine cut kota stone slab flooring 15-20mm thick over incl 20mm thick cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified & directed.
Supply & fix steel windows or ventilators fixed type, complete all as specified & directed.
Supply & fix 3mm thick sheet glass, ordinary quality, and glazing with oil putty/beading in square not exceeding 0.50sqm each pane complete all as specified & directed.
Surface excavation n.exc (not exceeding) 30cm deep and averaging 15 deep and getting out in soft /loose soil complete all as specified & directed.
M/L 75 mm thick cement concrete 1:3:6 type C-2 using (40 mm graded stone agg) as in sub base complete all as specified & directed.
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade coloured , set, jointed and pointed in neat cement slurry in floors With Grey Cement complete all as specified and directed.
Taking down carefully any type of battens or conduit point wiring with or except conduit (light, fan, socket or power) complete including fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, pendent light fittings, MCBs / isolators, fan regulators, tube light fittings etc removing material from site complete all as specified and directed.
Supply & fixing switch piano flush type, 05 / 06 Amps single pole, one way 240 volts complete all as specified and directed.
Material and labour for contineous brick edging with width equal to the depth of the brick of whole sub class 'B' bricks laid on edge complete all as specified and directed.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.48 MB
TenderdocumentsBR-EM.pdf
Tender Documents • 2.09 MB
BOQ_821063.xls
BOQ • 0.55 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .