Construction Installation of Prefabricated Kitchen Cum Staff shelter for Police Transit Camp Type B and Construction Installation of Prefabricated Police Booth Type D in District Leh
2022_PWD_7077_1
02 of SEL Leh of 2022-23
Open Tender
Civil Works - Buildings
Item Rate
180 days
Leh
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,000
Yes
DSE PWD Circle Leh
₹4 L
Yes
24 Sept 2022
21 Jul 2022
1 Aug 2022
21 Jul 2022
30 Jul 2022
21 Jul 2022
Amount
A= Korzok near Tsomoriri and Anlay= Rs. 87.00 Lacs
Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth upto 50 meter beyond 1m from cutting edge and disposal of surplus excavated earth asdirected: All kinds of soil.
Dumping stone including cost of stone on horiontal level, hand packed and compacted with hand roller including carriage complete job.
CEMENT CONCRETE (CAST-IN-SITU) Providing and laying in position cement concrete of specified grade including curing butexcluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) (Including Carriage and cost of materials)
CEMENT CONCRETE (CAST-IN-SITU) Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) ( Including Carriage and cost of materials)
Centering and shuttering including strutting, propping etc. and removal of form work for: a) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete.
15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 6 ( 1 cement : 6 fine sand) ( Including carriage and cost of material)
Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) ( Including carriage and cost of material)
Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stoneaggregate) finished with a floating coat of neat cement including cementslurry and curing complete, but excluding the cost of nosing of steps etc complete. 50 mm thick with 20mm nominal size stone aggregate. ( Including carriage and cost of material)
Providing and fixing strips in joints of terrazzo/ cement concrete floors. 40 mm wide and 6 mm thick
Technical specification for pre-fab structure made up of steel and puf panells in walls with attached toilet. Prefabricated shelter made up of steel structure and PUF Panels, colour profile sheets etc with Technical specification as given below :- 1. Design Parameter. a) Seismic = Zone V b) Wind /Snow load as per relecant IS codes for the region c) Temperature Range = () 40 to (+) 50 C d) Roof slope = 1:2 e) Dimension all as indicated in the reference drqwing to be provided as site are as directed by EIC at site. Technical specifications as per annexure "A" of NIT ...
Providing and fixing plain lining tongued and grooved, including wooden plugs complete with necessary screws and priming coat on unexposed surface Second class Teak Wood 12 mm thick Wall Paneling
Polishing on wood work with ready mixed wax polish on approved brand and manufacture on New work
Providing and fixing in position laminated Bamboo wood flooring with planks 12 mm thick with standard size, in appd colour, texture and finish having performance appraisal certificate. The flooring shall be fixed with tongued and groove interlocking system, with underlayment of 4 mm thick expanded polyethylene foadm sheets haveing density 40 kg /Cum over prepared surface with necessary quarter rond planks and door reducer of standard size wher3ever requried. The bamboo wood planks shall have minimum density of 1000 kgf all complete as per direction of the Engineer in charge flooring
Providing and fixing in position of PVC false ceiling panels of standard size 250 mm X 6mm thick with profiles (L,U&T) sections ) and GI Strips ( 50 mm X 3000 mmX3mm) of frame work complete job specification as approved by the Engineer - in - charge.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
3 X 10 sq. mm + 1 X 6.0 sq. mm earth wire
4 X 10 sq. mm + 2 X 6.0 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1 x 1.5 sq. mm
1 x 2.5 sq. mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Bell Push
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required
Supply and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 amps modular switch, connection
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 amps & 15/16 amps. Modular socket outlet and 15/16 amps modular switch
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recesses, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnection, powder painted including earthing etc. as required 4 way (4 +12) Double Door
6 way (4 +18) Double Door
8 way (4+18) Double Door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 6/16 amp
Supply and fixing of following sizes of PVC conduit alongwith accessories in surface/recessed including cutting the wall and making good the same in case of recessed conduit as required 25 mm
Supply, installation, testing & commissioning of GI Electrode Earthing with 84mm dia and 3 meter length, with 40mmx5mm thick the electrode should be hot-dip galvinised. The GI Electrode shall be pre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact between the electrode and compound should be eco-friendly GI Electrode Earthing should be maintinance free and does not require regular manual addition of water. The earthing pit should be covered with PVC cover.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. MCCB FP 200 Amp KA
On Load Change over Switch FP 100 Amp
Fabrication, supplying, installation testing and ciommissioning of following pannel made out of 2mm thick M.S. sheet, floor mounted, vermin and dust proof, outdoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly painted with providion for fixing of 1no incomer MCCB, 2 Nos outgoing MCCB'S MCCB type change over switch. 1 No including supply and fixing 3 sets of Aluminium Bus Bar, and 3 Nos strip 2 No strips for housing MCB's 24 Nos, MF Digital Meters and other allied accessories etc. as rquired (Make as per annexure).
Supplying and fixing of following rating 240/415 Volt's "C" Series miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning(Above to 32 Amp.) SPN 63 Amp
TPN 63 Amp
Supplying and fixing following luminaries as required LL20-111-XXX-65NE3
20watt LED tube light fitting. Wipro LL20-221-XXX-65NE3 or equivalent approved make.
Supplying and fixing LED type down lighter 12 watt
Supplying and fixing of 120 watt LED Street Light complete with GI pipe bracket duly embided along the parapet/ wall .Wipro LR02-132-XXX-57-G2 or equivalent approved make
Supplying and fixing of ehhaust fan 300mm size including connection etc as required (Heavyduty) CG transair or equivalent approved make
Supplying and fixing of exhaust fan 225 mm size shautter type including connection etc as required
Providing and fixing call Bell Ding Dong
Supply and fixing of 1.1 KV PVC insulated and PVC shaethed XLPE at power cable of following sizes on surface/ surface cables tray/0.50 mtr below ground level etc as required including carriage upto annexure enclosed) 70 sqmm 3.5 core Armoured
Providing and fixing water closet squattig pan (providing Indian type W.C pan with 100mm sand cast iron P or S trap 10 litre low level P.V.C flushing cistern incl. flush pipe of app. Make manually controlles device handle lever conforming to IS: 7231 woth all fittings and fixtures complete, incl cutting and making good the walls and floor whereover required. (580x440mm)
Providing and Fixing White vitreous peaestai type water coset (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern including flush pipe with manually controlled device (handle lever ) conforming to IS: 7231, with all fittings and fixtures, complete icluding cuttig and making good the walls and floors wherever required (580x440mm).
Providing and fixing wash basin with C.I./M.S. brackets, 15mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets,
Providing and fixing PVC Waste pipe for sink or wash basin including PVC waste fittings complete flexible pipe 32mm dia.
Providing and fixing mirror of superior glass of approved quality ) and of required shaped and size with plastic moulded frame of approved make and shade with 6mm thick hard board backing Rectangular shape.(1500x350mm)
Providing and fixing toilet paper holder C.P brass.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangements of approvd quality and colour. 600mm long towwl rail with total length of 645mm, 78mm wide and effective height of 88mm, weighing not less than 190gms.
Providing and fixing PTMT liquid soap container 109 mm wide, 125mm high and 112mm distance fom wall of standard shape with brackets of the same materials with snap fittings of approved quality and colour weighing not less than 105gms.
Providing and fixing PVC waste pipe of required disa including bends, Tee door bend, L bend trap jointed with addisive material ISI marked like prince, vector or vector or equivalent brand all complete job. 110mm dia bore
90mm dia bore
Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge. PN-16 pipe , 32mm OD(SDR-7.4)
PN-16 pipe , 25mm OD(SDR-7.4)
Providing and placing on terrace water storage tank with suitable locking arrangement and hole for inlet, outlet and overflow pipe like sintex, Electroplast, star etc or equivalent having ISI Licence.
Providing and fixing brass bib cock of approved quality (20mm nominal bore)
Providing and Fixing of C.P brass mixer of approved quality.
Providing and fixing C.P brass long nose bib cock ofapproved quality conforming to is standards and weigheing not less than 810gmx 20mm nominal bore.
Providing and fixing of gysers of approved brand and quality including all necessary fittings, cost and carriage complete job.(50ltr each)
P/F of 2 H.P water pump of standard quality with all necessary fittings complete job.
Insulation to water storage tank by way of using 25mm thick nitrile sheet glass wool, chicken mesh polythene and aluminium sheet.
Providing and fixing of PPR fixtures of standard quality. 25mm ball value
32mm ball value
25mm Tank Nipple
32mm Tank Nipple
32mm FTA
25mm FTA
Angle valve
Floor Grating (100mm dia)
Shower (100mm dia)
Const. of brick masonry chamber for underground C.I inspection chamber and bend with common burnt bricks in cement mortar 1:4 (1 Cement:4 coarse sand) incl RCC top slab and internal plaster complete as per standard design (internal dimension 455mmx610mmx45cm depth
B=Panamik Nubra and Shayok Rs. 37.00 Lacs
Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth upto 50 meter beyond 1m from cutting edge and disposal of surplus excavated earth asdirected: All kinds of soil.
Dumping stone including cost of stone on horiontal level, hand packed and compacted with hand roller including carriage complete job. All kinds of soil.
CEMENT CONCRETE (CAST-IN-SITU) Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) (Including Carriage and cost of materials)
CEMENT CONCRETE (CAST-IN-SITU) Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) ( Including Carriage and cost of materials)
Centering and shuttering including strutting, propping etc. and removal of form work for: a) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete.
15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 6 ( 1 cement : 6 fine sand) ( Including carriage and cost of material)
Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) ( Including carriage and cost of material)
Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stoneaggregate) finished with a floating coat of neat cement including cementslurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate. ( Including carriage and cost of material)
Providing and fixing strips in joints of terrazzo/ cement concrete floors. 40 mm wide and 6 mm thick
Technical specification for pre-fab structure made up of steel and puf panells in walls with attached toilet. Prefabricated shelter made up of steel structure and PUF Panels, colour profile sheets etc with Technical specification as given below :- 1. Design Parameter. a) Seismic = Zone V b) Wind /Snow load as per relecant IS codes for the region c) Temperature Range = () 40 to (+) 50 C d) Roof slope = 1:2 e) Dimension all as indicated in the reference drqwing to be provided as site are as directed by EIC at site. Technical specifications as per annexure "A" of NIT ...
Providing and fixing plain lining tongued and grooved, including wooden plugs complete with necessary screws and priming coat on unexposed surface Second class Teak Wood 12 mm thick Wall Paneling
Polishing on wood work with ready mixed wax polish on approved brand and manufacture on New work
Providing and fixing in position laminated Bamboo wood flooring with planks 12 mm thick with standard size, in appd colour, texture and finish having performance appraisal certificate. The flooring shall be fixed with tongued and groove interlocking system, with underlayment of 4 mm thick expanded polyethylene foadm sheets haveing density 40 kg /Cum over prepared surface with necessary quarter rond planks and door reducer of standard size wher3ever requried. The bamboo wood planks shall have minimum density of 1000 kgf all complete as per direction of the Engineer in charge flooring
Providing and fixing in position of PVC false ceiling panels of standard size 250 mm X 6mm thick with profiles (L,U&T) sections ) and GI Strips ( 50 mm X 3000 mmX3mm) of frame work complete job specification as approved by the Engineer - in - charge.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
3 X 10 sq. mm + 1 X 6.0 sq. mm earth wire
4 X 10 sq. mm + 2 X 6.0 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1 x 1.5 sq. mm
1 x 2.5 sq. mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Bell Push
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required
Supply and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 amps modular switch, connection
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 amps & 15/16 amps. Modular socket outlet and 15/16 amps modular switch
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recesses, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnection, powder painted including earthing etc. as required 4 way (4 +12) Double Door
6 way (4 +18) Double Door
8 way (4+18) Double Door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 6/16 amp
Supply and fixing of following sizes of PVC conduit alongwith accessories in surface/recessed including cutting the wall and making good the same in case of recessed conduit as required 25 mm
Supply, installation, testing & commissioning of GI Electrode Earthing with 84mm dia and 3 meter length, with 40mmx5mm thick the electrode should be hot-dip galvinised. The GI Electrode shall be pre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact between the electrode and compound should be eco-friendly GI Electrode Earthing should be maintinance free and does not require regular manual addition of water. The earthing pit should be covered with PVC cover.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. MCCB FP 200 Amp KA
On Load Change over Switch FP 100 Amp
Fabrication, supplying, installation testing and ciommissioning of following pannel made out of 2mm thick M.S. sheet, floor mounted, vermin and dust proof, outdoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly painted with providion for fixing of 1no incomer MCCB, 2 Nos outgoing MCCB'S MCCB type change over switch. 1 No including supply and fixing 3 sets of Aluminium Bus Bar, and 3 Nos strip 2 No strips for housing MCB's 24 Nos, MF Digital Meters and other allied accessories etc. as rquired (Make as per annexure).
Supplying and fixing of following rating 240/415 Volt's "C" Series miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning(Above to 32 Amp.) SPN 63 Amp
TPN 63 Amp
Supplying and fixing following luminaries as required LL20-111-XXX-65NE3
20watt LED tube light fitting. Wipro LL20-221-XXX-65NE3 or equivalent approved make.
Supplying and fixing LED type down lighter 12 watt
Supplying and fixing of 120 watt LED Street Light complete with GI pipe bracket duly embided along the parapet/ wall .Wipro LR02-132-XXX-57-G2 or equivalent approved make
Supplying and fixing of ehhaust fan 300mm size including connection etc as required (Heavyduty) CG transair or equivalent approved make
Supplying and fixing of exhaust fan 225 mm size shautter type including connection etc as required
Providing and fixing call Bell Ding Dong
Supply and fixing of 1.1 KV PVC insulated and PVC shaethed XLPE at power cable of following sizes on surface/ surface cables tray/0.50 mtr below ground level etc as required including carriage upto annexure enclosed) 70 sqmm 3.5 core Armoured
Providing and fixing water closet squattig pan (providing Indian type W.C pan with 100mm sand cast iron P or S trap 10 litre low level P.V.C flushing cistern incl. flush pipe of app. Make manually controlles device handle lever conforming to IS: 7231 woth all fittings and fixtures complete, incl cutting and making good the walls and floor whereover required. (580x440mm)
Providing and fixing wash basin with C.I./M.S. brackets, 15mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets,
Providing and fixing PVC Waste pipe for sink or wash basin including PVC waste fittings complete flexible pipe 32mm dia.
Providing and fixing mirror of superior glass of approved quality ) and of required shaped and size with plastic moulded frame of approved make and shade with 6mm thick hard board backing Rectangular shape.(1500x350mm)
Providing and fixing toilet paper holder C.P brass.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangements of approvd quality and colour. 600mm long towwl rail with total length of 645mm, 78mm wide and effective height of 88mm, weighing not less than 190gms.
Providing and fixing PTMT liquid soap container 109 mm wide, 125mm high and 112mm distance fom wall of standard shape with brackets of the same materials with snap fittings of approved quality and colour weighing not less than 105gms.
Providing and fixing PVC waste pipe of required disa including bends, Tee door bend, L bend trap jointed with addisive material ISI marked like prince, vector or vector or equivalent brand all complete job. 110mm dia bore
90mm dia bore
Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge. PN-16 pipe , 32mm OD(SDR-7.4)
PN-16 pipe , 25mm OD(SDR-7.4)
Providing and placing on terrace water storage tank with suitable locking arrangement and hole for inlet, outlet and overflow pipe like sintex, Electroplast, star etc or equivalent having ISI Licence.
Providing and fixing brass bib cock of approved quality (20mm nominal bore)
Providing and Fixing of C.P brass mixer of approved quality.
Providing and fixing C.P brass long nose bib cock ofapproved quality conforming to is standards and weigheing not less than 810gmx 20mm nominal bore.
Providing and fixing of gysers of approved brand and quality including all necessary fittings, cost and carriage complete job.(50ltr each)
P/F of 2 H.P water pump of standard quality with all necessary fittings complete job.
Insulation to water storage tank by way of using 25mm thick nitrile sheet glass wool, chicken mesh polythene and aluminium sheet.
Providing and fixing of PPR fixtures of standard quality. 25mm ball value
32mm ball value
25mm Tank Nipple
32mm Tank Nipple
32mm FTA
25mm FTA
Angle valve
Floor Grating (100mm dia)
Shower (100mm dia)
Const. of brick masonry chamber for underground C.I inspection chamber and bend with common burnt bricks in cement mortar 1:4 (1 Cement:4 coarse sand) incl RCC top slab and internal plaster complete as per standard design (internal dimension 455mmx610mmx45cm depth
C= Kharu, Upshi Tiari-Rong , Saboo crossing diversion near Sindhu Ghat and Mahabodhi crossing = Rs. 12.75 Lacs
Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth upto 50 meter beyond 1m from cutting edge and disposal of surplus excavated earth asdirected: All kinds of soil.
Dumping stone including cost of stone on horiontal level, hand packed and compacted with hand roller including carriage complete job. All kinds of soil.
CEMENT CONCRETE (CAST-IN-SITU) Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) (Including Carriage and cost of materials)
CEMENT CONCRETE (CAST-IN-SITU) Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) ( Including Carriage and cost of materials)
Centering and shuttering including strutting, propping etc. and removal of form work for: a) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete.
15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 6 ( 1 cement : 6 fine sand) ( Including carriage and cost of material)
Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) ( Including carriage and cost of material)
Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stoneaggregate) finished with a floating coat of neat cement including cementslurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate. ( Including carriage and cost of material)
Providing and fixing strips in joints of terrazzo/ cement concrete floors. 40 mm wide and 6 mm thick
Technical specification for pre-fab structure made up of steel and puf panells in walls with attached toilet. Prefabricated shelter made up of steel structure and PUF Panels, colour profile sheets etc with Technical specification as given below :- 1. Design Parameter. a) Seismic = Zone V b) Wind /Snow load as per relecant IS codes for the region c) Temperature Range = () 40 to (+) 50 C d) Roof slope = 1:2 e) Dimension all as indicated in the reference drqwing to be provided as site are as directed by EIC at site. Technical specifications as per annexure "A" of NIT ...
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
3 X 10 sq. mm + 1 X 6.0 sq. mm earth wire
4 X 10 sq. mm + 2 X 6.0 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1 x 1.5 sq. mm
1 x 2.5 sq. mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Bell Push
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required
Supply and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 amps modular switch, connection
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 amps & 15/16 amps. Modular socket outlet and 15/16 amps modular switch
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recesses, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnection, powder painted including earthing etc. as required 4 way (4 +12) Double Door
6 way (4 +18) Double Door
8 way (4+18) Double Door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 6/16 amp
Supply and fixing of following sizes of PVC conduit alongwith accessories in surface/recessed including cutting the wall and making good the same in case of recessed conduit as required 25 mm
Supply, installation, testing & commissioning of GI Electrode Earthing with 84mm dia and 3 meter length, with 40mmx5mm thick the electrode should be hot-dip galvinised. The GI Electrode shall be pre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact between the electrode and compound should be eco-friendly GI Electrode Earthing should be maintinance free and does not require regular manual addition of water. The earthing pit should be covered with PVC cover.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. MCCB FP 200 Amp KA
On Load Change over Switch FP 100 Amp
Fabrication, supplying, installation testing and ciommissioning of following pannel made out of 2mm thick M.S. sheet, floor mounted, vermin and dust proof, outdoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly painted with providion for fixing of 1no incomer MCCB, 2 Nos outgoing MCCB'S MCCB type change over switch. 1 No including supply and fixing 3 sets of Aluminium Bus Bar, and 3 Nos strip 2 No strips for housing MCB's 24 Nos, MF Digital Meters and other allied accessories etc. as rquired (Make as per annexure).
Supplying and fixing of following rating 240/415 Volt's "C" Series miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning(Above to 32 Amp.) SPN 63 Amp
TPN 63 Amp
Supplying and fixing following luminaries as required LL20-111-XXX-65NE3
20watt LED tube light fitting. Wipro LL20-221-XXX-65NE3 or equivalent approved make.
Supplying and fixing LED type down lighter 12 watt
Supplying and fixing of 120 watt LED Street Light complete with GI pipe bracket duly embided along the parapet/ wall .Wipro LR02-132-XXX-57-G2 or equivalent approved make
Supplying and fixing of ehhaust fan 300mm size including connection etc as required (Heavyduty) CG transair or equivalent approved make
Supplying and fixing of exhaust fan 225 mm size shautter type including connection etc as required
Providing and fixing call Bell Ding Dong
Supply and fixing of 1.1 KV PVC insulated and PVC shaethed XLPE at power cable of following sizes on surface/ surface cables tray/0.50 mtr below ground level etc as required including carriage upto annexure enclosed) 70 sqmm 3.5 core Armoured
D= Khaltsi =RS. 3.70
Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth upto 50 meter beyond 1m from cutting edge and disposal of surplus excavated earth asdirected: All kinds of soil.
Dumping stone including cost of stone on horiontal level, hand packed and compacted with hand roller including carriage complete job. All kinds of soil.
CEMENT CONCRETE (CAST-IN-SITU) Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) (Including Carriage and cost of materials)
CEMENT CONCRETE (CAST-IN-SITU) Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) ( Including Carriage and cost of materials)
Centering and shuttering including strutting, propping etc. and removal of form work for: a) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete.
15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 6 ( 1 cement : 6 fine sand) ( Including carriage and cost of material)
Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) ( Including carriage and cost of material)
Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stoneaggregate) finished with a floating coat of neat cement including cementslurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate. ( Including carriage and cost of material)
Providing and fixing strips in joints of terrazzo/ cement concrete floors. 40 mm wide and 6 mm thick
Technical specification for pre-fab structure made up of steel and puf panells in walls with attached toilet. Prefabricated shelter made up of steel structure and PUF Panels, colour profile sheets etc with Technical specification as given below :- 1. Design Parameter. a) Seismic = Zone V b) Wind /Snow load as per relecant IS codes for the region c) Temperature Range = () 40 to (+) 50 C d) Roof slope = 1:2 e) Dimension all as indicated in the reference drqwing to be provided as site are as directed by EIC at site. Technical specifications as per annexure "A" of NIT ...
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
3 X 10 sq. mm + 1 X 6.0 sq. mm earth wire
4 X 10 sq. mm + 2 X 6.0 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1 x 1.5 sq. mm
1 x 2.5 sq. mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Bell Push
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required
Supply and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 amps modular switch, connection
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 amps & 15/16 amps. Modular socket outlet and 15/16 amps modular switch
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recesses, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnection, powder painted including earthing etc. as required 4 way (4 +12) Double Door
6 way (4 +18) Double Door
8 way (4+18) Double Door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 6/16 amp
Supply and fixing of following sizes of PVC conduit alongwith accessories in surface/recessed including cutting the wall and making good the same in case of recessed conduit as required 25 mm
Supply, installation, testing & commissioning of GI Electrode Earthing with 84mm dia and 3 meter length, with 40mmx5mm thick the electrode should be hot-dip galvinised. The GI Electrode shall be pre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact between the electrode and compound should be eco-friendly GI Electrode Earthing should be maintinance free and does not require regular manual addition of water. The earthing pit should be covered with PVC cover.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. MCCB FP 200 Amp KA
On Load Change over Switch FP 100 Amp
Fabrication, supplying, installation testing and ciommissioning of following pannel made out of 2mm thick M.S. sheet, floor mounted, vermin and dust proof, outdoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly painted with providion for fixing of 1no incomer MCCB, 2 Nos outgoing MCCB'S MCCB type change over switch. 1 No including supply and fixing 3 sets of Aluminium Bus Bar, and 3 Nos strip 2 No strips for housing MCB's 24 Nos, MF Digital Meters and other allied accessories etc. as rquired (Make as per annexure).
Supplying and fixing of following rating 240/415 Volt's "C" Series miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning(Above to 32 Amp.) SPN 63 Amp
TPN 63 Amp
Supplying and fixing following luminaries as required LL20-111-XXX-65NE3
20watt LED tube light fitting. Wipro LL20-221-XXX-65NE3 or equivalent approved make.
Supplying and fixing LED type down lighter 12 watt
Supplying and fixing of 120 watt LED Street Light complete with GI pipe bracket duly embided along the parapet/ wall .Wipro LR02-132-XXX-57-G2 or equivalent approved make
Supplying and fixing of ehhaust fan 300mm size including connection etc as required (Heavyduty) CG transair or equivalent approved make
Supplying and fixing of exhaust fan 225 mm size shautter type including connection etc as required
Providing and fixing call Bell Ding Dong
Supply and fixing of 1.1 KV PVC insulated and PVC shaethed XLPE at power cable of following sizes on surface/ surface cables tray/0.50 mtr below ground level etc as required including carriage upto annexure enclosed) 70 sqmm 3.5 core Armoured
E= Spangmik near Pangong Lake, Tangtse, Southpullu , Changspa Crossing below ShantiStupa, Changspa crossing near Morviean Charge, MES Point,near Hotel Yak Tail, skara market = Rs. 59.00 Lacs RS. 64.96 Lacs .
Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth upto 50 meter beyond 1m from cutting edge and disposal of surplus excavated earth asdirected: All kinds of soil.
Dumping stone including cost of stone on horiontal level, hand packed and compacted with hand roller including carriage complete job. All kinds of soil.
CEMENT CONCRETE (CAST-IN-SITU) Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) (Including Carriage and cost of materials)
CEMENT CONCRETE (CAST-IN-SITU) Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) ( Including Carriage and cost of materials)
Centering and shuttering including strutting, propping etc. and removal of form work for: a) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete.
15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 6 ( 1 cement : 6 fine sand) ( Including carriage and cost of material)
Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) ( Including carriage and cost of material)
Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stoneaggregate) finished with a floating coat of neat cement including cementslurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate. ( Including carriage and cost of material)
Providing and fixing strips in joints of terrazzo/ cement concrete floors. 40 mm wide and 6 mm thick
Technical specification for pre-fab structure made up of steel and puf panells in walls with attached toilet. Prefabricated shelter made up of steel structure and PUF Panels, colour profile sheets etc with Technical specification as given below :- 1. Design Parameter. a) Seismic = Zone V b) Wind /Snow load as per relecant IS codes for the region c) Temperature Range = () 40 to (+) 50 C d) Roof slope = 1:2 e) Dimension all as indicated in the reference drqwing to be provided as site are as directed by EIC at site. Technical specifications as per annexure "A" of NIT ...
Providing and fixing plain lining tongued and grooved, including wooden plugs complete with necessary screws and priming coat on unexposed surface Second class Teak Wood 12 mm thick Wall Paneling
Polishing on wood work with ready mixed wax polish on approved brand and manufacture on New work
Providing and fixing in position laminated Bamboo wood flooring with planks 12 mm thick with standard size, in appd colour, texture and finish having performance appraisal certificate. The flooring shall be fixed with tongued and groove interlocking system, with underlayment of 4 mm thick expanded polyethylene foadm sheets haveing density 40 kg /Cum over prepared surface with necessary quarter rond planks and door reducer of standard size wher3ever requried. The bamboo wood planks shall have minimum density of 1000 kgf all complete as per direction of the Engineer in charge flooring
Providing and fixing in position of PVC false ceiling panels of standard size 250 mm X 6mm thick with profiles (L,U&T) sections ) and GI Strips ( 50 mm X 3000 mmX3mm) of frame work complete job specification as approved by the Engineer - in - charge.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
3 X 10 sq. mm + 1 X 6.0 sq. mm earth wire
4 X 10 sq. mm + 2 X 6.0 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1 x 1.5 sq. mm
1 x 2.5 sq. mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Bell Push
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required
Supply and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 amps modular switch, connection
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 amps & 15/16 amps. Modular socket outlet and 15/16 amps modular switch
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recesses, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnection, powder painted including earthing etc. as required 4 way (4 +12) Double Door
6 way (4 +18) Double Door
8 way (4+18) Double Door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 6/16 amp
Supply and fixing of following sizes of PVC conduit alongwith accessories in surface/recessed including cutting the wall and making good the same in case of recessed conduit as required 25 mm
Supply, installation, testing & commissioning of GI Electrode Earthing with 84mm dia and 3 meter length, with 40mmx5mm thick the electrode should be hot-dip galvinised. The GI Electrode shall be pre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact between the electrode and compound should be eco-friendly GI Electrode Earthing should be maintinance free and does not require regular manual addition of water. The earthing pit should be covered with PVC cover.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. MCCB FP 200 Amp KA
On Load Change over Switch FP 100 Amp
Fabrication, supplying, installation testing and ciommissioning of following pannel made out of 2mm thick M.S. sheet, floor mounted, vermin and dust proof, outdoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly painted with providion for fixing of 1no incomer MCCB, 2 Nos outgoing MCCB'S MCCB type change over switch. 1 No including supply and fixing 3 sets of Aluminium Bus Bar, and 3 Nos strip 2 No strips for housing MCB's 24 Nos, MF Digital Meters and other allied accessories etc. as rquired (Make as per annexure).
Supplying and fixing of following rating 240/415 Volt's "C" Series miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning(Above to 32 Amp.) SPN 63 Amp
TPN 63 Amp
Supplying and fixing following luminaries as required LL20-111-XXX-65NE3
20watt LED tube light fitting. Wipro LL20-221-XXX-65NE3 or equivalent approved make.
Supplying and fixing LED type down lighter 12 watt
Supplying and fixing of 120 watt LED Street Light complete with GI pipe bracket duly embided along the parapet/ wall .Wipro LR02-132-XXX-57-G2 or equivalent approved make
Supplying and fixing of ehhaust fan 300mm size including connection etc as required (Heavyduty) CG transair or equivalent approved make
Supplying and fixing of exhaust fan 225 mm size shautter type including connection etc as required
Providing and fixing call Bell Ding Dong
Supply and fixing of 1.1 KV PVC insulated and PVC shaethed XLPE at power cable of following sizes on surface/ surface cables tray/0.50 mtr below ground level etc as required including carriage upto annexure enclosed) 70 sqmm 3.5 core Armoured
Providing and fixing water closet squattig pan (providing Indian type W.C pan with 100mm sand cast iron P or S trap 10 litre low level P.V.C flushing cistern incl. flush pipe of app. Make manually controlles device handle lever conforming to IS: 7231 woth all fittings and fixtures complete, incl cutting and making good the walls and floor whereover required. (580x440mm)
Providing and fixing wash basin with C.I./M.S. brackets, 15mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets,
Providing and fixing PVC Waste pipe for sink or wash basin including PVC waste fittings complete flexible pipe 32mm dia.
Providing and fixing mirror of superior glass of approved quality ) and of required shaped and size with plastic moulded frame of approved make and shade with 6mm thick hard board backing Rectangular shape.(1500x350mm)
Providing and fixing toilet paper holder C.P brass.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangements of approvd quality and colour. 600mm long towwl rail with total length of 645mm, 78mm wide and effective height of 88mm, weighing not less than 190gms.
Providing and fixing PTMT liquid soap container 109 mm wide, 125mm high and 112mm distance fom wall of standard shape with brackets of the same materials with snap fittings of approved quality and colour weighing not less than 105gms.
Providing and fixing PVC waste pipe of required disa including bends, Tee door bend, L bend trap jointed with addisive material ISI marked like prince, vector or vector or equivalent brand all complete job. 110mm dia bore
90mm dia bore
Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge. PN-16 pipe , 32mm OD(SDR-7.4)
PN-16 pipe , 25mm OD(SDR-7.4)
Providing and placing on terrace water storage tank with suitable locking arrangement and hole for inlet, outlet and overflow pipe like sintex, Electroplast, star etc or equivalent having ISI Licence.
Providing and fixing brass bib cock of approved quality (20mm nominal bore)
Providing and Fixing of C.P brass mixer of approved quality.
Providing and fixing C.P brass long nose bib cock ofapproved quality conforming to is standards and weigheing not less than 810gmx 20mm nominal bore.
Providing and fixing of gysers of approved brand and quality including all necessary fittings, cost and carriage complete job.(50ltr each)
P/F of 2 H.P water pump of standard quality with all necessary fittings complete job.
Insulation to water storage tank by way of using 25mm thick nitrile sheet glass wool, chicken mesh polythene and aluminium sheet.
Providing and fixing of PPR fixtures of standard quality. 25mm ball value
32mm ball value
25mm Tank Nipple
32mm Tank Nipple
32mm FTA
25mm FTA
Angle valve
Floor Grating (100mm dia)
Shower (100mm dia)
Const. of brick masonry chamber for underground C.I inspection chamber and bend with common burnt bricks in cement mortar 1:4 (1 Cement:4 coarse sand) incl RCC top slab and internal plaster complete as per standard design (internal dimension 455mmx610mmx45cm depth
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .