Tender Value
₹19.4 L
EMD Value
₹38,720
Closing Date
29 Jun 2026, 2:00 pmClosed
EXECUTIVE ENGINEER PHED DIVISION KOLAYAT
EXECUTIVE ENGINEER PHED DIVISION KOLAYAT
Replacement of old and inefficient Monoblock motor pump set under sub dn kolayat
2026_PHCJA_567156_1
30/2026-27
Open Tender
Civil Works
Percentage
Kolayat
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Executive Engineer PHED Dn Kolayat
₹38,720
Yes
7 Jul 2026
11 Jun 2026
29 Jun 2026
11 Jun 2026
29 Jun 2026
11 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Part A :- | - | - | - | - |
| - | Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at synchronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected on C.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. Centrifugal Monoblock Pump set (Single Stage) | - | - | - | - |
| - | 5.5 KW (7.5 HP) | 1 | Each | 55,225 | ₹55,225 |
| - | 7.5 KW (10 HP) | 1 | Each | 67,514 | ₹67,514 |
| - | 11.0 KW (15 HP) | 1 | Each | 83,148 | ₹83,148 |
| - | Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves straight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - AISI- 410 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel Insertion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge.
Note: Rates are exclusive of tail piece/ dismantling joints and earth work. Manually Operated CI Sluice valve of Class PN-1.0 | - | - | - | - |
| - | 80 mm HW | 3 | Each | 6,301 | ₹18,903 |
| - | 100 mm HW | 3 | Each | 8,649 | ₹25,947 |
| - | 125 mm HW | 1 | Each | 11,173 | ₹11,173 |
| - | 150 mm HW | 1 | Each | 13,595 | ₹13,595 |
stage.html
html • 0.03 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.52 MB
TD_30.pdf
Tender Documents • 1.19 MB
BOQ_1008851.xls
BOQ • 0.34 MB
Corri2630U.pdf
PDF • 0.10 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .