Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹13.8 LAccepted-AOC | 1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | 2₹15.6 L+₹1.4 L (9.82%)Rejected-Finance H O WANI HOUSE II SHOWPORA SRINAGAR J K | 2 | Rejected-Finance BEING NOT LOWEST BIDDER | |
| 3 | 3₹15.9 L+₹1.7 L (12.0%)Rejected-Finance | 3 | Rejected-Finance BEING NOT LOWEST BIDDER | |
| 4 | 4₹16.1 L+₹2.0 L (13.9%)Rejected-Finance | 4 | Rejected-Finance BEING NOT LOWEST BIDDER | |
| 5 | 5₹16.8 L+₹2.6 L (18.5%)Rejected-Finance | 5 | Rejected-Finance BEING NOT LOWEST BIDDER |
Tender Value
₹15.3 L
EMD Value
₹30,700
Closing Date
25 Jun 2025, 6:00 pmClosed
AGE (I) NIMU
AGE (I) NIMU PIN 901312 C/O 56 APO
SPECIAL REPAIR OF BLDG NO NP-135, 10 X TOILETS BLOCKS OF 17 RAJPUT AT NIMU MIL STN UNDER AGE (I) NIMU
2025_MES_711323_1
AGE(I)/NIT-20/2025-26
Open Tender
Civil Works
Item Rate
180 days
AGE (I) NIMU
Please refer tender documetns
9 documents required · 9 mandatory
₹500
AGE (I) NIMU
₹30,700
25 Jul 2025
30 May 2025
2 Jul 2025
30 May 2025
25 Jun 2025
13 Jun 2025
Amount
Taking down chowkhats or frames n.exc 1.5 sqm each with shutters (without taking off shutters from the frame) and removing from site complete all as directed.
Taking down chowkhats or frames exc 1.5 sqm but n exc 4 sq.m each with shutters (without taking off shutters from the frame) and removing from site complete all as directed.
M&L for 2nd class Hardwood Plain, solid, straight chowkats and frames, wrought, rebated on the solid,, rounded or chamfered, put together with glue pinned at joints,
M&L for 30mm thick shutter, 2nd class Hardwood, Glazed and skeleton shutters, open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for ecuring glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, SSR Part I, Section 8 clause 8.24(b) as in ventilators;
M&L for 35mm thick 2nd class Hardwood, Plain, framed, Panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats
S&F for 3.0mm thick Sheet glass, ordinary quality and glazing with beads in square n. exc 0.5 sq. m in each pane
S&F 75 mm long Butt hinges, medium weight, cold rolled mild steel
S&F 100 mm long Butt hinges, medium weight, cold rolled mild steel
S&F for exruded aluminium alloy handles, 150mm size, fabricated type, anodised
S&F for exruded aluminium alloy handles, 100mm size, fabricated type, anodised
S&F 125 mm long, Aluminium anodised, barrel tower bolts of extruded section
S&F 200mm long, Aluminium anodised, barrel tower bolts of extruded section
S&F 250mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy
M&L for preparation of new wooden surfaces of any description over 10cm in width or girth and applying two coats of S/E paint over a coat of pink primer.
Dismantling floor, hearth or wall tiling including cement mortor bedding (but not baking), removing servicable tiles to store and rubbish off the permises.
Taking down cement or cement lime plaster any description on brick or stone wall surfaces, racking out joints and hacking out for key, scrubing down with water etc,
Demolition of cement concrete (Unreinforced) Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level)
Demoltion of reinforced cement Concrete Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work in sock well
M&L for 25mm thick cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) as in sub base for tiles
M&L for Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bedding layer in CM 1:4 complete all as specified and directed by Engr-in-charge.
M&L for Glazed ceramic coloured tiles in vertical surface such as skirting, dado 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles incl 10mm thick plastering in CM 1:6 complete all as specifed and directed by Engr-in-charge.
M&L 10mm thick cement plaster in CM (1:6) on fair faces of brick walls surface or concete surface, finished even and smooth w/o using extra cement complete all as specified and directed by Engr-in-Charge.
M&L 15mm thick cement plaster in CM (1:4) on fair faces of brick walls surface or concete surface, finished even and smooth w/o using extra cement and using water proofing compound (external surface) complete all as specified and directed by Engr-in-Charge.
M&L preparing new plastered surfaces of walls and applying two coat of cement base paint over a coat of primer all as specified and directed by Engr-in-charge.
M&L preparing new plastered surfaces of walls and applying two coat of dry distemper white or tinted over a coat of Chalk whiting, on plastered surfaces, prepara-tory to distempering all as specified and directed by Engr-in-charge.
M&L painting on steel surface over 10 cm width or girth including preparation of old painted surface of any description and applying two coats of synthetic enamel paint complete all as specified and directed by Engr-in-Charge.
Demolition of precast concrete block walling, built in cement mortar including all quoins, arches, pillars,etc, including ashlar facings,dressed stonework,precast concrete articles and precast concrete block walling
M & L Cement concrete 1:4:8 type D2 (40 mm graded crushed stone aggregate ) in foundations, filling and mass concrete complete all as specified. and directed by Engr-in-Charge.
M&L for Pre-cast cement concrete 1:3:6 type C1 (using 20mm graded agg) block masonry with solid blocks, exc. 10 cm in width and setting in mortar (1:4), complete
M&L for Reinforced cement concrete 1:2:4 type B1 (using 20mm graded agg ) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
M&L for Pre-cast Reinforced cement concrete 1:2:4 type B1 (using 20mm graded agg) as in Manhole cover slab and setting in mortar (1:4), complete
M&L for Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide..
M&L for Soakage well of 3M dia X 4.5M effective depth, excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and as per CESZ/TD/1078/2011
Dismantling water tanks of capacity exc 250 ltrs & n exc 500 ltrs and removing to stores
S&F for 1000 Ltrs Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I
Taking down 15mm bore steel tubing and connectionss, including cleaning for re-fixing or removal to stores
S&F for 25mm dia 3-layer PP-R P o l y p r o p y l e n e random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded p o l y p r o p y l e n e random fittings fixed complete to walls, ceilings or in floors etc.
S&F 25mm Nipple suitable for HDPE water tank. (Minimum weight 15 mm-38gms/20mm-
S&F in repairs, 15mm bore Bib taps fancy type chromium plated, crutch of butterfly handle, screwed down, screwed for iron pipes or for brass ferrule and fixed
S&F, PVC connections 15mm size with PTMT nuts of length 600mm
S&f in repairs, Stop valves15mm, fancy type ,chromium plated with long shank and cup (concealed type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed.
S&F in repairs, 15mm bore dia Pillar taps, fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed
S&F in repairs, vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe)
S&F in repairs PVC valveless 10 litres capacity, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including bracket
Supply only, Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern
S&F in repair vitreous china WHB white, flat back, size 550 x 400mm including brackets, 32mm Brass CP waste fitting, PVC waste pipe & 450mm connection.
M & L PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or floor of 110mm bore pipe complete all as specified and directed by Engr-in-charge
S&F for 110 mm bore PVC (SWR) bends any radius ®
S&F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors
M&L for 75mm ,PVC (SWR) floor trap, plain with grating including jointing with solvent cement
S&F, 110mm PVC (SWR) 'P' trap
M&L for 100mm thick cement concrete 1:3:6 type C2 bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested;
M&L for Chequered cement concrete tiles 20cm x 20cm x25mm thick, set, jointed and pointed in neat cement slurry with grey cement and no pigment in floors over screed bed or bedding layer of mortar 15mm thick in CM 1:4 over complete all as spd and directed byEngr-in-charge.
M&L for 75mm thick Cement concrete 1:4:8 type D- 2, (40mm graded aggregate) as in sub base to bring the coarse in proper levelling.
Dismantling Plain or corrugated steel sheeting,any gauge, thickness, including Nainital or similar pattern roof coverings
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as specified
Excavation in trenches n exc 1.5 mtr wide and n. exc 1.5 mtr in depth in hard / dense soil for laying of GI/CI pipes and getting out in any type of soil complete all as specified and directed.
Returning filling in, including spreading ,levelling watering and well ramming in layer not exceeding 25cm in soft /loose soil including making good of disturbed surfaces complete all as specified and directed .
Removing excavated soil to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed .
Supply & laying of 50 mm , 3 - Layers PP-R Polypropylene random copolymer) pipes SDR 7.4 & SDR 11 UV stablised antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fitting fixed complete all as specified and directed by Engr in charge.
Supply & laying of 25 mm , 3 - Layers PP-R Polypropylene random copolymer) pipes SDR 7.4 & SDR 11 UV stablised antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fitting fixed complete all as specified and directed by Engr in charge.
Supply and fixing PP-R ball valves ( brass insert ) for 25mm dia pipe as per requirement of the site all as specified and directed.
Supply and fixing PP-R ball valves ( brass insert ) for 50 mm dia pipe as per requirement of the site all as specified and directed.
M&L for cutting existing GI pipes and insertion of new Tee branches of suitable size to take branch connection of 50mm dia PP-R.
Construction of stone masonary valve pit chamber of size 90cm x 90 cm x 90 cm (internal dimension) including all necessary excavation and earth work in hard / dense soil and disposal of surplus soil to a distance not exceeding 50 meters & deposting the same as directed including PCC in foundation of the mixture (1:4:8) D-2 stone masonary in cement motor 1:4 rendering 15mm thick in cement mortar 1:4 internally finished even and fair and pointing flush externally as the work proceeds in the same mortar as of stone masonary including mild steel frame (made out of angle in 40x40x6mm) MS steel cover 3.15 mm thick with handle and locking arrangement with ginges angle iron flat as required at site including painting of all posed MS work with two coat of synthetic enamel paint over a coat of red oxide primer and painting all the steel surfaces embedded in PCC with two coats of black bituminuos paint and all other relevant work complete .
Taking out old unserviceable underground cable of any size/ make/ type etc from excavated trenches/ on poles/ passing through pipes etc from different locations complete all as spd.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3½ core
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for taking out pipe line etc for repairs / laying cables etc and getting out in soft / loose soil complete all as specified and as directed by the Engineer - in - Charge.
Excavation in trenches by cutting of road crossing/PCC hard standing, under boundary wall for laying of pipe/cable including making good the existing surface with same finish to match the original finish complete all as specified and directed by Engr-in-charge.
Material and labour for un reinforced pre cast concrete cable cover class LV type I, flat size 250 mm x 150 mm x 40 mm.
Sand cushioning to under ground cable complete all as specified in clause 19.75 of SSR Part - I.
Supply and fix or laying in trenches/on wall/poles/structures as in repairs GI tubing light grade for road crossing/for cable protection/fixing of pigmi lights etc,of 50 mm dia sizes including necessary provision for cable entry if reqd in pigmi lights pole, fixing screws complete as required complete all as specified and directed by Engr-in-charge.
Dismantling and Taking down LT U/S panels incl all outgoing and incoming connections and making good the disturbed area from site all as specified and directed by Engineer-in-Charge.
M&L for Busbar chambers with 4 aluminium busbar strip of rating 400 Amp 6 way fixed on angle iron of size 40mm x40mm x5mm Including provision of MCCB 4 pole 160 Amp capacity with connected to busbar complete all as specified and directed by Engineer in Charge. Note : Cost of MCCB measured and paid separatly .
S&F in repaire of MCCB 160 Amps 25 KA, 4 Pole complete all as specified and directed by Engr-in-Charge.
M & L for Earthing complete with galvanised steel earth plate electrode of size (600 x 600 x 6.3) mm thick buried directly into ground vertically to depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, surrounded on all sides by alternate layers of 150 mm thick charcoal and common salt, connected to MS galvanized earh strip of size 32 x 6 mm by means of lugs, bolts, nuts, washer, check nuts of galvanised iron or steel all as shown in Electrical plate No. 3, wire protected by dia 15 mm bore light grade GI Pipe laid in floor and fixed to wall with proper size of clamps and watering pipe of bore 20 mm dia GI light grade including wire mesh funnel, PCC, earth chamber pit with PCC 1:2:4 type B-1 using 20 mm grade stone aggreate including form work cement mortar including CI Pit cover with frame necessary excavation and earth work in any type of soil including testing on completion for desired result all as specified.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc
M & L Point wiring with 1.5 Sqmm (nominal area) FRLS PVC insulated unsheathed multistranded copper conductor cable in and including PVC concealed conduit 20 mm dia medium grade ISI marked including fittings and accessories with continues PVC insulated copper cable with copper conductor of same size as in phase/neutral/earth cable connecting to common earth dolly including metal flush box and white cover plate with frame complete One light point/one fan point controlled by one switch
M & L Point wiring with 1.5 Sqmm (nominal area) FRLS PVC insulated unsheathed multistranded copper conductor cable in and including PVC concealed conduit 20 mm dia medium grade ISI marked including fittings and accessories with continues PVC insulated copper cable with copper conductor of same size as in phase/neutral/earth cable connecting to common earth dolly including metal flush box and white cover plate with frame complete One 3 pin 5 amps socket outlet independent with cables 1.5 sqmm size
M & L Point wiring with 1.5 Sqmm (nominal area) FRLS PVC insulated unsheathed multistranded copper conductor cable in and including PVC concealed conduit 20 mm dia medium grade ISI marked including fittings and accessories with continues PVC insulated copper cable with copper conductor of same size as in phase/neutral/earth cable connecting to common earth dolly including metal flush box and white cover plate with frame complete One 3 pin 5 Amp socket outlet on same board.
M & L point wiring with FRLS cable size 2.5 Sq mm nominal area PVC insulated and unsheathed cable single core multistranded, copper conductor in PVC concealed conduit for one 3 pin, 15 Amps socket out let on independent board and multistrand insulated copper earth continuity conductor of size 2.5 sqmm all as specified and directed by Engr-in-Charge.Make(cable) - Havells/Plaza/Finolex
S & F repair Socket, 6A - 2/3 pin combined 2 module Same Board, all as directed.
S&F repair Modular switch 1 way 6A, 1 module all as directed.
S&f repair Socket, 6A - 2/3 pin combined 2 module Independet board, all as directed.
S&F in Repair Socket 6A/16A - 2/3 pin combined 2 module, all as directed.
M&L in repair for ceiling rose surface Bakelite 65x50mm two to three terminal complete all as specified and as directed by Engr-in-Charge.
S&F in repair basic all purpose surface and wall mounted LED batten with polycarbonate housing and integreted electronic driver of cap 20 watt, 4 feet long, with all accessories complete all as per specified and as directed by Engr-in-Charge.
Supply and fixing LED lights fittings 10/12 watt, 220 v, AC decorative box type with driver , holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
S & F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.
S&F in repair sheet metal powder coated versatile Double door SPN distribution board, 12 way suitable for MCB's fitted with copper bus bar rated 200amps, neutral link , earth bar and din rail suitable for use on 240 Volt, 50Hz .
M&L in repair for MCB SPN 63 Amp, 240V with 10KA breaking capacity of 'C' series in distribution boards all as specified and directed.
S&F in repairs to MCB SP 6-32 Amp with 10KA breaking capacity of 'C' series in distribution boards all as specified and directed.
Supply and fix in repair exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz,RPM 1200,Copper winding of sweep 250mm.
Earthing complete with galvanised steel earth plate electrode of size (600 x 600 x 6.3) mm thick buried directly into ground vertically to depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, surrounded on all sides by alternate layers of 150 mm thick charcoal and common salt, connected to galvanized earh lead wire of size 4.0 mm dia by means of lugs, bolts, nuts, washer, check nuts of galvanised iron or steel all as shown in Electrical plate No. 3, wire protected by dia 15 mm bore light grade GI Pipe laid in floor and fixed to wall with proper size of clamps and watering pipe of bore 20 mm dia GI light grade including wire mesh funnel, PCC, earth chamber pit with PCC 1:2:4 type B-1 using 20 mm grade stone aggreate including form work cement mortar including CI Pit cover with frame necessary excavation and earth work in any type of soil including testing on completion for desired result all as specified.
M/S WEB COMPNAY (BID ID -3327253)
RISING SUN ENGG WORKS (BID ID -3327306)
M/S LIBE & CO (BID ID -3327544)
M/S OSHO TRADERS (BID ID -3327718)
M/S UNITED CONSTRUCTION CO. (BID ID -3327350)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .