Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹87.3 LAccepted-AOC HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹96.3 L+₹8.9 L (10.2%)Rejected-Finance 403 GH MANSADEVI COMPLEX PANCHKULA 134109 HARYANA | PANCHKULA | HARYANA | 134109 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹99.9 L+₹12.5 L (14.4%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹1.0 Cr+₹16.4 L (18.7%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹1.2 Cr+₹34.8 L (39.8%)Rejected-Finance RSD STREET HALL BAZAR AMRITSAR 143001 PUNJAB | AMRITSAR | AMRITSAR | PUNJAB | 143001 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹1.7 L
Closing Date
10 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col S S Babu
Headquarters 138 Works Engineers Pin-914138 C/o 56 APO
PROVN OF ONSITE OXYGEN GENERATION PLANT FOR COVID-19 AND OTHER PATIENTS IN 153 GH (UNDER GE 865 EWS AT LEH
2021_MES_440911_1
138WE/L-14/2021-22
Open Tender
Industrial/Medical GAS
Item Rate
90 days
GE 865 EWS
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
Yes
GE 865 EWS
₹1.7 L
Yes
20 Jul 2021
6 May 2021
12 Jun 2021
6 May 2021
10 Jun 2021
27 May 2021
60 days
Amount
Supply installation testing and commissioning of Medical gaseous Oxygen Plant (pressure swing absorption type plant) of flow capacity 88320 ltrs per day (3.68 Sm3/hrs), 5.0 to 6.0 pressure Bar and 93+3% purity including 3 years comprehensive maintenance (Defect liability period) which consists of subsystems- PSA Oxygen generator, Air compressor with suction filter, Refrigeration dryer system, Air bufer storage system, Air filteration system, Medical/ Food upgradation equipment, Oxygen buffer tank, Final pressure regulation device, Booster compressor, Oxygen cylinder filling manifold, Electrical items etc & all other components as per site condition/ design requirement and fully satisfaction to users complete all as specified and directed by Engr-in-charge.
Note :- The Entire plant has been under warranty period up to 36 months from the date of installation. The Plant Specification are as follows :- Plant Specification 1. PSA Oxygen Generator - 01 No (i) Plant type PSA (Pressure Swing Absorption) (ii) Installation :Indoor with temperature 5 to 35 deg C. (iii) Max Out side temp at 35 Degree and min-35 Degree and min - 35 Degree Celeius (Sub Zero) (iv) Site Elevation from Main Sea level - 3524 mtrs above msl. (v) Area classification : Non hazadous (vi) Duty : Continious (vii) PLC controlled Oxygen generating plant to produce 3.68 SM3/hrs of medical grade Oxygen at 93+3% purity and pressure of 5 to 6 Barg. (viii) Must have online oxygen analyser supplied by generator supplier. Generator Make - Oxair/Oxymat/RIFRAIR or equivalent Make of critical components Switching valves - Mesto/Omal/Asco or equivalent Molecular sieve-Uop/Tosho or equivalent PLC-Siemens/Uninonies or equivalent Oxygen Analyser - Nutron/Servomax or equivalent Qualification of Generator Supplier (i) Should be approved as per medical device directive MDD93/42/EEC (ii) Should have CE Mark meeting ISO 10083 standard. (iii) ISO certification.
2. Air Compressor with suction filter - 01 No (i) FAD of Compressor : 0.91 M3/min (ii) Discharge Pressure : 8 Barg (iii) Compressor type : Lubricated Screw Compressor (iv) Power Supply : 415V, 50 Hz (v) Type of Cooling : Air Cooling (vi) Discharge Temperature : Room Temperature +-15 degree centgrade (vii) Canapoy : Provided (viii) Oil Removal : Cyclone filter included Make : Kaesar/ Altas Copco/Elgi or equivalent
3. Refrigeration dryer System - 01 No (i) Processing capacity: 0.91 m3/min FAD (ii) Maximum working pressure : 8 Barg (iii) Type : Refrigerated (iv) Power Supply : 230V, Single phase. 50Hz (v) Type of Cooling : Air Cooling Make - Altascopos/Summits or equivalent
4. Air Buffer Storage System - 01 No (i) Size : Approx 150 liters water volume (ii) Design pressure : 10 Barg (iii) Material of construction : Carbon Steel
5. Air Filtration System Typically filters of 01 micron rating and 0.1 micron with drain valve is provided
6. Medical/Food upgradation equipment (i) Coal tower (ii) Activated carbon filter (iii) Bacterial filter
7. Oxygen buffer Tank - 01 No (i) Size - 150 ltrs water volume (ii) Design Pressure - 10 Barg (iii) Material of construction - carbon steel
8. Final Pressure Regulation device Desired set pressure of 4.4 bar
9. Booster Compressor - 01 No (i) 12.2 Cylinder per day capacity non lubricated type booster compressor (ii) Air cooled and electric motor driven compressor (iii) Filling capacity - 150 Bar (iv) Make Rix /Burckhardt/SIAD or equivalent
10. Oxygen Cylinder filling manifold - 01 No An Oxygen Cylinder filling manifold of Size 2x4 Cylinders shall be provided alongwith bank isolation valves. Pressure gauges and safety vaves, Typically, in a shift on bank consisting of 4D type cylinders can be filled up.
11. Electrical items (i) Electrical switch gear to be mouted near plant (Purchaser shall connected power supply to it. (ii) Power/Control cabling from switchgear to equipment Note :- Since Oxygen is very critical for operation of hospital the supplier of te plant should ensure following :- (i) The Plant and equipment should be high quality. (ii) Plant supplier should provide minimum 20 days training to the Hospitals Operation & Maintenance team during installation and commissioning of plant. This will include class room lecture on plant training and safety procedure required to be followed. (iii) Plant supplier should monitor performance of plant by asking plant operating staff to provide status of running plants performance in a week by email followed by review the same via phone, Plant supplier should advise plant operator for any remedial action required to address concerns remotely during entire CMC period. (iv) Plant supplier shall conduct once in a month refreshment training of minimum one hour via video call to provide training to operating staff.
Supply, laying and testing cable XLPE insulated screened PVC beded, galvanised steel strip or wire armoured, electric Power cables (Heave Duty) 1100 Volts grade with Stranded aluminium conductor of Size 30 sqmm 3.5 Core complete all as specified and directed by Engr-in-charge.
M&L for point wiring with copper conductor cable Multistrand, single core 1.5 Sqmm size for one light point or bell point / Ex : fan point controlled by one switch including one run of 1.5 Sqmm multistand PVC copper conductor cable for earth continuity in and including PVC casing and capping of approved size and quality fixed on walls/ceiling including rectangular PVC board / Wooden board heavy duty type for mounting switches/ sockets etc complete all as specified and directed by Engr-in-charge.
(a) One light point controlled by one-one way switch complete all as specified and directed by Engr-in-charge.
(b) One 3 pin socket out let 5 AMP on independent board complete all as specified and directed.
All as per item No 2 above but for power point 3 pin switch socket 15 AMP with PVC copper conductor cable multistrand unsheathed 2.5 Sqmm on independent board incl one run 1.5 Sqmm multistanded PVC copper conductor cable for earth continuity and including PVC casing and capping fixed on wall including PVC board/Wooden board heavy duty type for mounting / switches/ sockets etc complete all as specified and as directed by Engr-in-charge.
S&F ceiling rose surface bakelite three terminal type complete all as specified and directed by Engr-in-charge.
S&F Switch socket combination 2 in 1.3 pin 5 AMP flush type complete all as specified and directed by Engr-in-charge.
S&F Switch socket combination 2 in 1.3 pin 5 and 15 AMP flush type complete all as specified and directed by Engr-in-charge.
S&F in replacement of old unserviceable MCB DB double door 12 way SPN with suitable AMP rated busbar 240 Volt complete all as specified and directed by Engr-in-charge.
S&F in replacement of old unserviceable MCB 04 Pole 415 Volts 63 Amp complete all as specified and directed by Engr-in-charge.
S&F in replacement of old unserviceable MCB single pole 240 volts 6 to 32 Amps complete all as specified and directed by Engr-in-charge.
S&F in repairs decorative ultra slim square profile linear LED lighting fixtures with extruded polycarbonate, enviromental friendly energy efficient ready to use pack of Delite LED of capacity 18W LED 6000K, 4 feet long (white colour) having driver connector block etc complete with all accessories prewired and connecting electrically to ceiling rose using PVC insultated and overall sheathed flexible copper conductor cable of size 0.75 Sqmm 3 core all as required at site complete all as specified and directed by Engr-in-charge.
Supply and installation of electric convector heat panel with over heat protection thermo statically controlled detachable wall mounting (digital LED dispaly, digital room temperature sensor, totally silent operations of heater & thermostat of size width 1200mm, height 450mm, depth 90mm of rated capacity 2600 watts 230 volts 50 Hz complete with all other acceesories complete all as specified and directed by Engr-in-charge.
Earthing complete with galvanised iron earth plate electrode 600x600x6mm burried directly in ground (earth pit not less thatn 2.25mtr deep below ground level) with top as earth plate not less than 1.5 mtr below normal ground level, connected with 25x4mm size GI strip as earthled, by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 40mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15, type B1 in pit with precast RCC M-15 (1:2:4), type B-1 (using 20mm graded crushed stone aggreates) in cover reinforced with XPM not less than 4.0 kg per Sqm, test point etc., all as shown in electric plate No 3 of SSR Part-I (2009), complete with necessary earth work in any type of soil, removal to a distance not exceeding 50mtr, including testing on completion, complete all as specified and directed by Engr-in-charge. Note :- Earth pit chamber and RCC pit cover shall be painted with two coats of red synthetic enamel paint over one coat of primer including preparing of surface.
M&L for comprehensive maintenance for the 1st year after exipry of defect liability period and attending any breakdown or maintenance work/ checking the serviceablity of Oxygen generation plant for having continous serviceablity of plant for any number of time as desired by Engr-in-Chrage including replacement of all defective /unservciable parts of the entire plants as per OEM Manual including routine maintenance for smooth functioning of the plant, complete all as specified and directed by Engr-in-charge.
M&L for comprehensive maintenance for the 2nd year after exipry of defect liability period and attending any breakdown or maintenance work/ checking the serviceablity of Oxygen generation plant for having continous serviceablity of plant for any number of time as desired by Engr-in-Chrage including replacement of all defective /unservciable parts of the entire plants as per OEM Manual including routine maintenance for smooth functioning of the plant, complete all as specified and directed by Engr-in-charge.
M&L for screed bed or bedding layer of mortar 15mm thick for laying floor finishes etc in cement mortar 1:6 complete all as specified and directed by Engr-in-charge.
M&L for Non-skid ceramic tiles 7 to 8mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match joint free complete all as specified and directed by Engr-in-charge.
M&L for precast cement concrete block masonary (1:3:6) type C-1 using crushed stone 20mm graded aggregates) set and jointed in cement mortar 1:6 complete all as specified and directed by Engr-in-charge.
M&L for rendering 10mm thick in cement mortar 1:6 on internal brick wall/ concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed by Engr-in-charge.
Preparation of new decorated surface of wall by washing rubbing down and stopping of old surface and applying two coats of oil bounds distemper complete all as specified and directed by Engr-in-charge.
Preparation of old decorated surface of wall by washing rubbing down and stopping of old surface and applying two coats of oil bounds distemper complete all as specified and directed by Engr-in-charge.
M&L for cutting holes into or through brick walls built in cement mortar or cement lime mortar and stone walls built in time mortar or walls of lime concerete inserting GI tubing 15mm dia exc half brick n exc one brick area N exc 150 Sq cm and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required cutting holes in brick walls in cement mortar for complete all as specified and directed by Engr-in-charge.
S&F anodised aluminium snap grid of size 605 x 605 mm frame work of false ceiling including hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5 dia 40mm long complete all as specified and directed by Engr-in-charge.
M&L Perforated particle boards 12mm thick or tiles for insulation and accoustic purposes, 60cm x 60cm in size complete all as specified and directed by Engr-in-charge.
S&F anodised aluminium frames or door, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed by Engr-in-charge.
S&F anodised aluminium door shutters, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, anodised alumimium snap beading screws etc. complete all as specified and directed by Engr-in-charge.
S&F for mild steel frame of grade Fe-410 W (Gde E-250) Quality B work in roof trusse purlins, cranes grantries rails and fasterning (beam, tee angle channel or flat sections), wind ties etc including distance pieces and cleats etc complete all as specified and directed by Engr-in-charge.
M&L for 2nd class soft wood clean sawn as in scantling fixed with nails exceeding 13 Sqcm and n exc 25 Sqcm in section complete all as specified and directed by Engr-in-charge.
M&L for 9mm thick prelaminated particle board interior grade, prelaminated one side with decorated choice lamination and other side balancing white fixed with screws/nails to timber frame work as in wall pannelling/ceiling /cup board shutters complete all as specified and directed by Engr-in-charge.
M&L for 50mm thick for wall wood wool building slabs, light weight, type 1 fixed with nails to timber framework complete all as specified and directed.
M&L for 50mm thick for ceiling wood wool building slabs, light weight, type 1, fixed with nails to timber framework complete all as specified and directed by Engr-in-charge.
M&L for wooden floor tiles 7mm thick with dove tailed joints laid over 150 micron polythene film and 3mm thick foam as per manufactures instructions and fixed with decorative wooden beadings as per site requirement complete all as specified and directed by Engr-in-charge. Make: ActionTessa/ Asian/ VTC Vinyl/Standard/ As approved by GE.
M&L for (1:2:4) type B1 (20mm graded aggregated) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughts and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed by Engr-in-charge.
EESSI
Airgases Projects Pvt Ltd
M/S MALIK CHAND SIRI RAM
Intrernational Engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .