Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.2 LAccepted-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹16.2 L+₹98,800 (6.51%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹16.5 L+₹1.4 L (8.98%)Rejected-Finance ASTBAL MOHALLA BANASAR BAGH ROAD PATIALA GATE SANGRUR 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | L3 | Rejected-Finance Being L3 |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
3 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh Anup Gupta,IDSE CWE Patiala
HQ CWE Patiala Bldg No 26 New Lal Bagh Patiala 147001
REPAIR REPLACEMENT AND MAINTENANCE OF HT CABLES HT OH LINES HT POLES AND CONNECTED ITEMS IMPROVEMENT TO EXISTING HT OH LINES AT MIL STN SANGRUR UNDER GE SOUTH PATIALA
2021_MES_495707_1
CWE/PAT/T-73/2021-22
Open Tender
Civil Works
Item Rate
180 days
PATIALA
As per cover 1
6 documents required · 6 mandatory
₹500
Yes
GE SOUTH PATIALA
₹36,000
Yes
24 Jan 2022
17 Dec 2021
5 Jan 2022
17 Dec 2021
3 Jan 2022
29 Dec 2021
17 Dec 2021 - 24 Dec 2021
60 days
Amount
Dismantling and taking out RCC/Steel poles/struts in any location and of any size including anticlimbing device & insulators of any size and type complete all as specified and as directed.
Taking down old aluminium conductor of any size and GI wire/ cradles etc from poles in any location complete all as specified and as directed.
Dismantling cross arms of MS channel or angle section etc. from poles/ 2 pole/ 4 pole structure complete all as specified and as directed.
Dismantling stay assembly complete with accessories complete all as specified and as directed.
Supply and errecting in replacement prestressed concrete pole 11 mtr long 152mmx152mm at top and 152mmx260mm at bottom, class 9, including painting with one coat of synthetic enamel paint in alternate strips of black and yelow colour 30 cm height each total 05 Nos commencing form the top of PCC coping and numbering of pole complete all as specified and as directed.
Pin type porcelain vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height,150 mm dia for 11000 volts grade complete all as specified and as directed.
Disc type insulator, porcelain,vitreous 145mm high and 255mm dia ball and socket type white brown or green single disc assembly for tension with tension clamps for conductors working pressure 11000 volts complete all as specified and as directed.
S&F in repairs stay assembly complete with accessories as shown in electrical plate No 1 with 20 mm dia stay rod, stay wire etc complete all as specified and as directed. (Note : Earth work and PCC shall be measured and paid separately)
S&F in repairs High tension lightning arrestor expulsion type complete with all fittings transmission class discharge capacity 65 Kilo Amps complete all as specified and as directed.
S&F in repairs switch air break Gang Operated, triple pole mechanically operated, mounted on 12 insulators and steel frame with operating mechanism worked from ground level of 11000 volt grade for current rating 200 Amps with DP fuse including complete all as specified and as directed.
Supply laying & testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts earthed grade, of 95 Sq mm 3 core including taking out old cable complete all as specified and as directed. (Earth work and cable protection will be measured and paid separately).
Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm complete all as specified and as directed.
Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm complete all as specified and as directed.
Anti climbing device, spikes type fabricated out of MS bars(round,square an flat) including nuts, bolts washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and as directed.
Danger notice plate of 1.6 mm thick mild steel sheet vitreous enamelled white with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for HT 25x20cm size complete all as specified and as directed.
M&L for supply, stringing and fixing on poles, ACSR conductor including jointing with and including aluminium binding wire of 14 SWG on insulators complete all as specified and as directed. (Unit quoted rate includes for cutting of branches of trees coming across the overhead line)
M&L for cross arms, bracings, supports clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated inclusive of one primer coat one under coat and one finishing coat of synthetic enamel paint complete all as specified and as directed.
Galvanised steel wire 4 mm dia for continuos earth, cradles, hexagonal/ rectangular complete all as specified and as directed.
Painting to existing of PCC poles 11m long long with one coat of synthetic enamel paint in alternate strips of black and yelow colours 30 cm height each total 05 Nos commencing form the top of PCC coping incuding painting of cross arms, nut bolts, clamps etc as fixed on pole with two coats of aluminium paint and marking pole No with paint as per approved pattern, complete all as specified and as directed. Numbring shall be hand written only, size of letter 100X10mm (Heightxwidth)
Servicing incl calibration/setting of all parameters and repairs of HT VCBs 11 KV of Crompton Greaves make complete incl cleaning and greasing including replacing of unserviceable parts as per existing and testing for satiafactory operation as per manufacturer standards complete all as specified and as directed. Note : Spares shall be measured and paid seperately.
Supply only of VCB indicator lamp LED type as per existing colour code (as required) and making all connections as per existing complete all as specified and as directed.
Supply only of tripping and closing coil of VCB (Crompton Greaves makes) trolly as per existing complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm buried directly in ground (earthpit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level , connected to galvanised earth strip 32x6 mm thick by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No -4 connected to machinary /panel complete including PCC pit in PCC (1:3:6) type C-1, pre cast RCC (1: 1 1/2:3) nominal mix cover slab reinforced with 8 mm dia mild steel deformed bar 15cm centre to centre and suitable handle of 10 mm dia round bar including necesary excavation earth work in soft/loose soil and disposal of soil to a distance n.exc 50m complete all as specified and as directed.
Scretching cleaning and preparation of old painted external surfaces to transformer of any size with two coats of synthetic enamel paint and writing SM/MES Nos complete all as specified and as directed.
Disconnecting and taking down the defective transformers indoor/outdoor type 11 KV/433 Volts of capacity 75 KVA to 315 KVA from any position transporting to auth workshop for repairs, shifting back to site after repairs and installing at original position. Repairs to transformers connecting up, commissioning and testing. Note: Unit quoted rate includes for draining out transformer oil, opening up transformer core and HV and LV windings to detect faults, reassembling the transformer after necessary repairs incl replacement of top rubberised / fiber gasket and worn out fastners such as nuts ,bolts, and washers for fixing of top covers complete all as specified and as directed. Note : Supply only of any parts to be replaced shall be measured and paid separately.
Supply only of HV copper winding 3 limbs with the existing size and gauge of copper winding wire of weight as per original complete all as specified and as directed.
Supply only of LV copper winding 3 limbs with the existing size and gauge of copper winding wire of weight as per original complete all as specified and as directed.
Supply only of HV brass rods with porcelian bushing, nuts, bolts, washers gaskets suitable for 100 kva to 250 KVA transformer of any type complete all as specified and as directed.
Supply only of LV brass rods with porcelain bushing , nuts, bolts, washers gaskets suitable for 100 kva to 250 KVA transformer of any type complete all as specified and as directed.
Supply only of air breathers suitable for transformers 11 KV / 433 volts of capacity up to 250 KVA complete all as specified and as directed.
Supply and replacement of Silica gel of breathers of transformers of type, any capacity and in any location complete all as specified and as directed.
Servicing of Transformer by arresting leakages by tightning nuts, bolts, repalcement of worn out washer of top cover and LV bushings , HV bushings complete all as specified and as directed.
De-hydration and filteration of transformer oil of transformer any capacity indoor/ outdoor type with dehydration machine incl checking of dielect strength of transformer oil before and after dehydration complete all as specified and as directed.
Supply and topping up the insulating oil for transformer of appropriate grade confirming to IS- 335 suitable for 11 kV/433 volts step down transformser complete all as specified and as directed.
Excavation in trenches n.exc 1.5 m deep and n.exc 1.5 m wide getting out in soft/ loose soil complete all as specified and as directed.
All as per item No 35 here-in-before but depth exceeding 1.5m and not exceeding 3m complete all as specified and as directed.
Returning filling in including spreading leveling, watering and well ramming in layers n exc25cm in soft/ loose soil complete all as specified and as directed.
Removing excavated soil to a distance not exc. 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed.
M&L for sand cushioning with dry and clean over and under the cable, 80 mm under and 150 mm over the cable complete all as specified and as directed.
Supply and laying un-reinforced pre cast concrete cable covers conforming to IS-5820-1970, class HV, type 2 flat of size 450mm x 180mm x 40mm laid in trenches as protection to cables complete all as specified and as directed.
GI tube light grade 80 mm bore complete all as specified and as directed.
M&L for PCC 1:3:6 type C2 (40 mm graded aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in platform, filling and mass concrete, coping to pole etc., including necessary form work if required and applying two coats of white wash to exposed surfaces coping/ platform complete all as specified and as directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts etc., including provision of binding wire complete all as specified and as directed.
Supply only chain link MS Glvanized fencing any size or type complete all as specified and as directed.
S&F of framed brackets of angles, flat iron strips or tees with web and flanges cut to shape, drillied and conunterssunk for screw, including bending and welding angles, as necessary gusset plated riverting etc., not exceeding 10 Kgs each bracket conforming to Fe 290 Gde-165 complete all as specified and as directed.
Supplying and laying synthetic Rubber insulated mats 16 mm thick for voltage upto 11 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of size 2mx1m complete all as specified and as directed.
Periodical cutting of all branches along above/under the over head lines with clearance of 2m in Cantt area. (Approx length of HT/LT over head lines - 10.00 Kms) Note : (i) Periodical (Quarterly as per schedule fixed by the GE/Engr-in-Charge and approved by the Stn HQ.(ii) Payment shall be made at the end the of each qtr.(iii) Cutting/Trimming record register sign by contracrt to be maintained Quarterly basis.
AR CONSTRUCTIONS
NARINDER KUMAR SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .