| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹58.9 LAccepted-AOC | ₹58.9 L Quoted ₹60.5 L | L1 | Accepted-AOC Being L1 bidder |
| 2 | L2₹63.4 L+₹2.9 L (4.72%)Rejected-Finance | ₹63.4 L+₹2.9 L (4.72%) | L2 | Rejected-Finance Not being L1 bidder |
| 3 | L3₹63.9 L+₹3.3 L (5.50%)Rejected-Finance | ₹63.9 L+₹3.3 L (5.50%) | L3 | Rejected-Finance Not being L1 bidder |
| 4 | L4₹65.3 L+₹4.8 L (7.93%)Rejected-Finance OFFICE 4 9 SWARG ASHRAM NANAK RAM COLONY PARMANAND CHOWK DELHI 110009 | DELHI | DELHI | DELHI | 110009 | ₹65.3 L+₹4.8 L (7.93%) | L4 | Rejected-Finance Not being L1 bidder |
| 5 | L5₹72.4 L+₹11.9 L (19.6%)Rejected-Finance | ₹72.4 L+₹11.9 L (19.6%) | L5 | Rejected-Finance Not being L1 bidder |
Tender Value
₹84.7 L
EMD Value
₹1.5 L
Closing Date
7 Apr 2025, 6:00 pmClosed
Chief Engineer (RnD) Delhi
HQ CE (RnD) Delhi, Probyn Road Delhi-54
SPECIAL REPAIR OF BUILDING NO P-46 (PROTECTIVE DEVICE DIVISION) OF DRDE GWALIOR UNDER GE (I) RnD DELHI
2024_MES_683603_2
CE RnD/DLI-26/GWL/2024-25
Open Tender
Civil Works
Item Rate
180 days
Gwaliorr
As per tender documents
7 documents required · 7 mandatory
₹1,000
GE (I) RnD Delhi
₹1.5 L
Yes
11 Jun 2025
10 Mar 2025
14 Apr 2025
10 Mar 2025
7 Apr 2025
24 Mar 2025
Amount
Dismantling of wall and ceiling board (fiber pulp, insulation, etc) or insulation board/brackets, any thickness including framework and disposal of unserviceable material complete all as directed by Engr-in-Charge.
Dismantiling of wall ceiling board (fiber pulp, insulation, etc) or insulation board/brackets, any thickness without frame and disposal of unserviceable materials complete all as per directions of Engr-in-Charge.
M&L for providing and fixing mineral fibre 16 mm thick beveled tegular mineral fibre Anti microbial false ceiling tile confirming to ISO 5 (Class 100) specifications false ceiling tiles at all heights of size 595 x 595 mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance 85%, Thermal Conductivity k=0.052 0.057 w/m K, Fire Performace as per (BS 476 pt 6 & 7) in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @ 120 gsm) comprising of main T runners of 15 x 32 mm of length 3000 mm, cross T of size 15 x 32 mm of length 1200 mm and secondary intermediate cross T of size 15 x 32 mm of length 600 mm to form grid module of size 600 x 600 mm suspended from ceiling using galvanized mild steel item (galvanised @ 80 gsm) 50 mm long 8 mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod upto 1000 mm length and L-shape level adjsuter of size 85 x 25 x 2 mm, spaced at 1200 mm centre to centre along main 'T'. The system should rest on periphery walls/partitions with the help of GI perimeter wall angle of size 24 x 24 x 3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall SS screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions fo the Engineer-in-Charge.
Supply and fixing 12.5mm thick gypsum ceiling boards of size 595mm X 595mm, fully perforated made from plaster board having glass fiber confirming to IS 2095 Part-I, having perfortions of 9.7mm X 9.7mm at 19.4mm c/c backed with non woven tissues having an NCR of 0.79 with 50mm resin bonded glass wool backing in true horizontal level suspended on existing interlocking metal.
M&L Painting ceiling boards with two coats of premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour over priming coat with water thinnable cement primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content less than 50 grams/ litre.
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, of area 3 sqm and below architrave, holdfasts etc. and disposal of unserviceable material complete all as directed by Engr-in-Charge.
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, of area 3 sqm architrave, holdfasts etc. and disposal of unserviceable material complete all as directed by Engr-in-Charge.
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material complete all as directed by Engr-in-Charge.
M&L for providing and fixing powder coated aluminium section (minimum thickness of powder coating 50 micron) for fixed portion aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately).
M&L for providing and fixing powder coated aluminium (minimum thickness of powder coating 50 micron) work for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately).
M&L for providing and fixing 12 mm thick prelaminated particle board with decorative lamination on both sides flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.
M&L for providing and fixing float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the directions of engineer-in-charge. (Cost of aluminium snap beading is deemed to be included in quoted rates).
M&L for providing and fixing double action hydraulic floor spring with stainless steel cover plate minimum 1.25 mm thickness of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.
M&L for providing and fixing 100mm of size Brass mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
M&L for providing and fixing powder coated (minimum thickness of powder coating of 50 micron) aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-charge.
M&L for providing and fixing factory made PVC door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and jointed with 2 Nos of 150 mm long brackets of 15x15 mm MS square tube, the vertical door frame profiles to be reinforced with 19x19 mm MS square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using MS screws of 65/ 100 mm size, complete as per manufacturer’s specification and direction of Engineer-in-Charge.
M&L for providing and fixing 30 mm thick factory made plain panel PVC door shutter consisting of frame made out of MS tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. MS frame shall have a coat of steel primers of approved make and manufacture. MS frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the MS frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer's specification & drawing.
M&L for providing and fixing 200x10 mm aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete.
M&L for providing and fixing 150x10 mm aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete.
M&L for providing and fixing 300x16 mm aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete.
M&L for providing and fixing 100x63x3.2 mm ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete.
M&L for providing and fixing 125 mm aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete.
M&L for providing and fixing 100 mm aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete.
Demolishing lime concrete manually/ by mechanical means and disposal of material outside MOD land as per direction of Engineer-in-charge.
M&L for providing and laying in position Cement concrete 1:4:8 type D-2 (40mm graded stone aggregate) as in foundation filling or mass concrete.
M&L providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 Kg per square metre for damp proofing after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
Taking down water proofing treatment including plaster from roof of any discription including lose surface, scraping of surface with wire brush or any other method, sweeping, clean & whasing down with water to remove dust etc and removing scraped materials outside of MOD land.
M & L for Brushing neat cement slurry with 3.0 Kg of cement per Sqm complete all as specified and directed Engr-in-Charge.
M&L for 15mm thick screed bed or bedding layer in CM 1:3 mixed with liquid water proofing compound as per manufacturar instructions. Roof surface finished fair and even to maintain the proper slope of roof surface etc complete all as specified or directed. (Note : Liquid WPC shall be measured and paid seperately)
M&L for Waterproofing on roof and parapets including flashing and junctions of parapet, kerb wall etc. as under :- (a) Applying bituminous primer on cleaned and dried surface @ 0.40 litre/Sqm. (b) Laying of 3mm thick APP based polymeric water proofing membrane (weighing not less than 3kg/sqm) reinforced with polyster non wove fabric. (wt. not less than 150 gms/sqm) by thermo fusion using butance torch with 10cm longitudinal and 15cm end overlaps firmly bonded and levelled by heating with butane torch complete all as specified and directed by Engr-in-Charge. (c) Painting the expose APP membrane surface with bituminous aluminium paint @0.15 Kg/Sqm.
Supply of liquid water proofing compound ISI marked complete all as specified and directed.
Demolishing cement concrete manually/ by mechanical means including and disposal of unserviceable material out side MOD land as per direction of Engineer-in-charge.
Demolishing RCC work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material outside MOD land as per direction of Engineer-in-charge.
Dismantling tile work of thickness of tiles 10 mm to 25 mm in floors and roofs laid in cement mortar including disposal of unserviceable material outside MOD land as per direction of Engineer-in-charge.
M&L for providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over and including 12 mm thick rendering in cement Mortar 1 : 3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete all as specified and directed Engr-in-charge.
M&L for providing and laying rectified glazed ceramic floor tiles of size 300x300mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid over and including 20 mm thick screed bed in Cement Mortar 1 : 4 (1 Cement : 4 Coarse sand) bed, jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete all as specified and directed Engr-in-charge. .
M&L for providing and laying vitrified floor tiles size 600x600 mm and 8 to 10 mm thick with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid over and including 20mm thick screed bed in cement mortar 1 : 4 (1 cement : 4 coarse sand) bed, jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc, complete all as specified and directed Engr-in-charge.
M&L for providing and laying vitrified tiles size 600x600 mm and 8 to 10 mm thick, with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over and including 12 mm thick rendering in cement mortar 1 : 3 (1 cement : 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.
Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material outside MOD land as per direction of Engineer-in-charge.
M&L for providing and fixing 18 mm thick Granite stone slab colour and texture black, cherry/ ruby red, area of any size fixed as whole not partially, prepolished mirror finished, premoulded and prepolished, machine cut for kitchen platforms, window cills, facias and similar locations of required size, approved shade, colour and texture laid over and including 20 mm thick base cement mortar 1 : 4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish complete at all levels.
M&L for 20 to 25 mm thick Kota stone prepolished (mirror finish) Kota stone slab flooring on 20 mm thick bed or cement mortar 1 : 4 (1 cement : 4 coarse sand) Drak shade pigment using ordinary cement area of any size complete all as specified and directed. Note :- Kota Stone in steps as tread to be provide in single piece and edgs should be rounded and complete all as specified and directed by Engr-in-Charge.
M&L for prepolished (mirror finish) Kota Stone slabs 18-20 mm thick in risers of steps, skirting, dado and pillars, area of any size to be provided in single piece laid over and including 12 mm thick rendering in CM 1 : 3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs complete all as specified and directed.
M&L for Chequered precast cement concrete tiles 20 to 22mm thick (Dark Shade) in footpath & courtyard, laid over 20mm thick screed bed of cement mortar 1:4 with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete all as specified and directed.
Demolishing brick work In cement mortar, manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material as per direction of Engineer-in-charge.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan to any redius in half brick thick wall built in CM 1:4 complete all as specified and directed.
Taking down cement plaster, any description on brick or stone wall etc, including raking out joint, hacking for key, scrubbing down with water complete all as specified and directed.
M&L for 15 mm thick cement plaster of mix 1 : 6 (1 cement : 6 fine sand) on brick or concrete surface complete all as specified and directed.
M&L for 15 mm thick cement plaster of mix 1 : 4 (1 cement : 4 fine sand) on brick or concrete surface complete all as specified and directed.
M&L for providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed.
M&L for white cement based putty of average thickness 1mm, of approved brand and manufacture, over the plastered wall surface to prepare the surface even and smooth complete.
M&L for distempering two coats on new work with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/ litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification.
M&L for distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying two coats, to achieve even shade and colour.
M&L for one coat of plastic emulsion paint on old decorated surface wall of approved brand and manufacture to give an even shade complete all as specified and directed.
Taking up or down 15mm dia steel tubing and connections including cleaning and refixing or removal to store complete all as specified and directed.
All as per srl item No 55 above but 20mm dia of pipe.
All as per srl item No 55 above but 25mm dia of pipe.
Disconnecting damaged overhead/ terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge.
M&L for providing and placing on terrace (at all floor levels) polyethylene water storage tank of capacity 1000 Ltr triple layered, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank complete all as specified and directed.
M&L for providing and fixing 15 mm dia nominal bore GI pipe medium grade concealed pipe complete with GI fittings and clamps, making good the walls etc., including painting with anti corrosive bitumastic paint, cutting chases and making good the wall.
M&L for providing and fixing 15 mm dia nominal bore GI pipes medium grade exposed on wall complete with GI fittings and clamps, including cutting and making good the walls etc complete all as specified and directed.
M&L for providing and fixing 20 mm dia nominal bore GI pipes medium grade exposed on wall/floor complete with GI fittings and clamps, including cutting and making good the walls etc complete all as specified and directed.
M&L for providing and fixing 25 mm dia nominal bore GI pipes medium grade exposed on wall complete with GI fittings and clamps, including cutting and making good the walls etc complete all as specified and directed.
M&L for providing and fixing 15 mm nominal bore CP brass long nose bib cock of approved quality conforming to IS : 8931 standards and weighing not less than 810 gms.
M&L for providing and fixing 20 mm nominal bore brass stop cock of approved quality confirming to IS : 8931.
M&L for providing and fixing 15mm nominal bore CP brass angle valve of approved quality conforming to IS : 8931.
M&L for providing and fixing 15 mm nominal bore CP brass stop cock (concealed) of standard design and of approved make conforming to IS : 8931.
M&L for providing and fixing PTMT Ball cock 20 mm nominal bore, 120 mm long, weighing not less than 198 gms; of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball.
M&L for providing and fixing white vitreous China flat back wash basin size 550x400 mm with single 15 mm CP brass pillar tap with CI brackets, 32 mm CP brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required.
M&L for providing and fixing 15 mm nominal bore with 45 cm length unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.
M&L for providing and fixing 100 mm diameter CP brass shower rose with 15 or 20 mm inlet.
M&L for providing and fixing in PTMT towel rail 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gmscomplete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
M&L for providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively with 5 litre white P.V.C. automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including cutting and making good the walls and floors wherever required.
Dismantling 75 to 80 mm dia CI, PVC or asbestos rain water pipe with fittings and clamps including disposal of unserviceable material as per direction of Engr-in-Charge.
Dismantling 100 mm dia CI, PVC or asbestos rain water pipe with fittings and clamps including disposal of unserviceable material as per direction of Engr-in-Charge.
M&L for providing and fixing 75 mm dia Sand cast iron S&S waste and vent pipes as per IS : 1729.
M&L for providing and fixing 100 mm dia Sand cast iron S&S waste and vent pipes as per IS : 1729.
M&L for providing and fixing 75 mm dia sand cast iron S&S plain bend of required degree as per IS - 1729.
M&L for providing and fixing 100 mm dia sand cast iron S&S plain bend of required degree as per IS - 1729.
M&L for providing and fixing 75 mm dia sand cast iron S&S bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete as per IS - 1729.
M&L for providing and fixing 100x100x100 mm Sand cast iron S&S single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete as per IS - 1729.
M&L for providing and fixing 75x75x75 mm Sand cast iron S&S single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete as per IS - 1729.
M&L for Sand cast iron S&S Slotted cowl (terminal guard) 100 mm dia.
M&L for providing and fixing on wall face 110 mm diameter unplasticised Rigid PVC Single socketed rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
M&L for providing and fixing on wall face 75 mm diameter unplasticised Rigid PVC Single socketed rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
M&L for providing and fixing on wall face unplasticised - PVC moulded 87.5° Bend 75 mm dia for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
M&L for providing and fixing on wall face unplasticised - PVC moulded 87.5° Bend 110 mm dia for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
M&L for providing and fixing 100 mm sand cast iron, trap with 100 mm inlet and 75 mm outlet complete all as specified and directed by Engr-in-Charge.
M&L for providing and fixing white vitreous China Orissa pattern WC pan of size 580x440 mm with integral type foot rests with 100 mm dia sand cast iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls fixed in repairs.
Fixing only in repairs stainless steel kitchen sink with CI brackets and stainless steel plug 40 mm, Flexible (coil shaped) PVC waste pipe 32mm dia with length not less than 700 mm including PVC waste fittings including painting of fittings and brackets, cutting and making good the walls wherever required.
M&L for providing and fixing in repairs stainless steel A ISI 304 (18/ 8) kitchen sink 510x1040 mm bowl depth 250 mm as per IS : 13983 with CI brackets and stainless steel plug 40 mm, Flexible (coil shaped) PVC waste pipe 32mm dia with length not less than 700 mm including painting of fittings and brackets, cutting and making good the walls wherever required.
M&L for providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with CP brass screws and washers complete.
M&L for Diluting and injecting chemical emulsion for POST- CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. with Chlorpyriphos/ Lindane E.C. 20% with 1% concentration.
M&L for Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 : 2 (1 cement : 2 Coarse sand) to match the existing floor with Chlorpyriphos/ Lindane E.C. 20% with 1% concentration.
Supply only chemical emulsion Chlorpyriphos/ Lindane emulsifiable concentrate of 20% in sealed containers including delivery as specified.
Dismantling G.S. Sheet roofing including ridges, hips, valleys and gutters etc.,and stacking the material within 50 metres lead and disposal of unserviceable materials complete all as directed by Engr-in-Charge.
Supply and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer?in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.
M&L for Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete all as specified and directed by Engr-in-Charge.
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. complete all as specified and directed.
S&F Venitian blinds (Designer pattern) of washable fabric material, with aluminium channels, operating arrangements etc complete all as specified and as directed.
M&L for Providing and fixing precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc upto fifth flooor level including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required Centering complete precast cement concrete shall be of 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources)
M&L for Thermo-mechanically treated steel reinforcement bars of grade Fe-500D or more for RCC work including straightening, cutting, bending, placing in position and binding all complete upto or above plinth level.
M&L for Finishing walls with Acrylic Smooth exterior paint of required shade : 13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Taking up or down 40mm dia steel tubing and connections all as specified and directed.
Supply and fixing GI pipe medium grade of 40 mm dia with all fittings complete on walls/floor etc complete all as specified and direcetd.
Excavation in trenches in soft/loose soil not exceeding 1.5 metre deep and not exceeding 1.5 metre width and getting out including forming bottom surface to required slope/gradient for laying cables/protection pipes etc complete all as specified and directed by Engineer-in-Charge including removing cable covers carefully & stacking properly for re-use all as directed. Note : Excavation shall be made carefully in order to avoid damage of existing cable and protection cover.
Returning, filling in, including spreading, levelling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed & tested complete all as specified and directed.
Removal of surplus excavated spoil not exceeding 50 metre distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 metre above the starting point complete all as specified.
Supply and Fix Gun metal gate valve of size 40 mm dia, with iron wheel heads , screwed both ends for iron pipe and fixed.
Supply and fix Gun metal gate valve of size 20 mm dia, with iron wheel heads , screwed both ends for iron pipe and fixed.
M&L for Cutting existing pipe line for alterations or additions necessarily done in position without taking down and inserting Tee of size 80x80 x 40mm for tapping all as specified and directed.
M&L for valve chamber of internal size 750x750x750mm comprising of 50mm thick PCC 1:5:10 type E2 foundation, 230mm thick brick wall in CM 1:6, 15mm thick plastering in CM 1:4 internally and externally up to 50mm be;ow GL,100mm thick PCC 1:3:6 type B1 as in copings,3mm thick MS sheet cover with suitable hinges and locking arrangement, painting steel surfaces with two coats of synthetic enamel paint over a coat of primerincluding necessary earth work and excavation in any type of soil complete all as directed.
Taking down copper/aluminium point wiring (light, fan, socket or power ) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors etc.
M&L for Point Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium grade PVC conduit 20mm dia,and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
M&L for point wiring independent with 1.5 sqmm multi stranded PVC insulated unsheathed copper conductor cable (FRLS) in and including PVC Concealed conduit 20 mm dia medium garde for modular switch socket 5 Amps of suitable size module including PVC insulated unsheathed 1.5 sqmm copper conductor continuous earth wire and connecting with earth dolly including necessary cutting chasing for concealing of conduit and making good the distrubed surfaces matching with existing specification complete all as specified and directed
All as per srl item No 116 above but 5 Amp three pin socket outlet on same board.
M&L for Wiring for twin control light point with 1.5 Sqmm FRLS PVC insulated copper conductor single core cable in surface / recessed medium grade PVC conduit 20mm dia, 2 way modular switch, modular plate, suitable GI box and earthing with 1.5 Sqmm FRLS PVC insulated copper conductor single core cable etc. as required
M&L for point wiring with 2.5 sqmm multi stranded PVC insulated unsheathed copper conductor cable (FRLS) in and including PVC concealed conduit ISI marked 20 mm dia medium grade for 3 pin 15 amp module socket outlet independent controlled by one swich including PVC insulated unsheathed 2.5 sqmm copper conductor continuous earth wire and connecting with earth dolly including necessary cutting chasing for concealing of conduit and making good the disturbed surfaces matching with existing specifications complete all as specified and directed
S&F in replacement of Modular switch 1 Way 6 Amp , 1 Module AC 230 volt complete all as specified and as directed.
S&F in replacement of Modular Bell push 6 Amp 1 Module AC 230 Volts.
S&F in replacement of door bell , AC 230V ding dong single phase complete all as specified
S&F in replacement of Modular switch 2 Way 6 Amp , 1 Module AC 230 volt complete all as specified and as directed.
S&F in replacement of Modular switch 1 Way 16 Amp , 1 Module AC 230 volt complete all as specified and as directed.
S&F in replacement of Modular socket , 6 A - 2/3 pin combined , 2 Module AC 230 volt complete all as specified and as directed.
S&F in replacement of Modular socket , 6 A/16 Amp - 5/6 pin combined , 2 Module AC 230 volt complete all as specified and as directed.
S&F Modular GI box alongwith modular base & cover plate for modular switches in recess etc. for 2 module (75mmx75mm) complete all as specified and as directed.
S&F Modular GI box alongwith modular base & cover plate for modular switches in recess etc. for 3 module (100mmx75mm) complete all as specified and as directed.
S&F Modular GI box alongwith modular base & cover plate for modular switches in recess etc. for 4 module (125mmx75mm) complete all as specified and as directed.
S&F Modular metal flush box alongwith white cover plate with frame but 8 module (125mmx125mm) complete all as specified and as directed.
S&F in replacement of ceiling rose 65 x 50mm 3 terminal AC 230 volt complete all as specified and directed
Supplying and fixing two module modular stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
S&F surface and wall mounted 20Watt LED tube light fitting extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver input voltage AC 230 V, 50 HZ complete all as specified and directed.
S&F energy saving decorative wall mounting LED Lighting fixtures as mirror light made out of poly corbonate with high output diffuser, 2 feet , 10 watt LED and making connections complete all as specified and directed by Engineer in charge.
S&F Decorative recess mounted 36 watt LED lumaire , full output luminaire for modern offices with CRCA powder coated body and new generation high effciency diffuser to provide soft glare free light complete with driver,holders & LED Lamps suitable for 600 x 600 mm modular grid ceiling complete all as specified.
S&F recessed mounted LED downlighter 9 W with pressure die cast aluminium heat sink, & PC diffuser in white powder coated finish with integrated driver complete all as specified.
Supplying and fixing 125A rating and breaking capacity 16 KA 3 pole MCCB 'C' curve with thermo magnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
S&F in replacement of MCB TPN 63 Amps 10 KA, 'C' series all as specified and directed.
S&F in replacement of MCB TPN 40 Amps 10 KA, 'C' series all as specified and directed.
S&F in replacement of MCB SPN 32 Amps 10 KA, 'C' series all as specified and directed.
S&Fin replacement of MCB SP 6 to 32 Amps 10 KA , "C' series all as specified and directed.
S&F in replacement of sheet metal enclosures single phase industrial box single pole and neutral with two pin earth plug and socket with plug top including single pole MCB 20 Amps, 230V, 50 Hz 'C' series complete all as specified and directed.
S&F in replacement of sheet metal enclosures single phase industrial box double pole and neutral with two pin earth plug and socket with plug top including double pole MCB 32 Amps, 230V, 50 Hz 'C' series complete all as specified and directed.
Supplying and fixing 32 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing of surface mounting, vertical type, 415 Volt, TPN 8 way MCCB distribution board doble door (MCCB as incomer) of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCCBs as required .
S&F in replacement of sheet metal enclosures for DBs when MCB to used TPN 8 way double door powder coated factory made IP 43 protection, IP 09 and provision of four pole, MCB/isolator/RCCB as incommer and SP/DP MCBs as outgoing fixed on wall/metal board/ wooden board complete all as specified and as directed.
S&F in replacement of sheet metal enclosures for DBs when MCB to used TPN 4 way double door powder coated factory made IP 43 protection, IP 09 and provision of four pole, MCB/isolator/RCCB as incommer and SP/DP MCBs as outgoing fixed on wall/metal board/ wooden board complete all as specified and as directed.
Supplying and fixing 8 way, single pole and neutral, sheet steel, MCB distribution board double door, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.
M&L for Sub main wiring with two single core PVC insulated cable (FRLS) 2X6 Sqmm + 1X6 Sqmm earth wire (Nominal dia) copper conductor multistrand and drawing in and including PVC concealed conduit ISI marked 32 mm dia, medium grade 6 sqmm multistrand copper conductor PVC green unsheathed cable for earth continuity including necessary cutting and chasing complete all as specified and directed. Note : 3 run of 6 Sqmm wire and one run of PVC conduit shall be measured as one unit.
M&L for Sub main wiring with four single core PVC insulated cable (FRLS) 4X16 Sqmm + 2X6 Sqmm earth wire (Nominal dia) copper conductor multistrand and drawing in and including PVC concealed conduit ISI marked 32 mm dia, medium grade 6 sqmm multistrand copper conductor PVC green unsheathed cable for earth continuity including necessary cutting and chasing complete all as specified and directed. Note : 4 run of 16 Sqmm wire and 2 run of 6 Sqmm wire and one run of PVC conduit shall be measured as one unit.
M&L for Sub main wiring with two single core PVC insulated cable (FRLS) 2X4 Sqmm + 1X4 Sqmm Earthwire (Nominal dia) copper conductor multistrand and drawing in and including S&F PVC concealed conduit ISI marked medium grade, 1x4 sqmm multistrand copper conductor PVC green unsheathed cable for earth continuity complete all as specified and directed. (for single phase industrial socket box) Note : 3 run of 4 Sqmm wire and one run of PVC conduit shall be measured as one unit.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate . Earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt upto 1.5 meter depth all around the earth plate and connected to earth lead of GI strip 25x5 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel and thimbles and other end of the earth lead connected to Plant/equipment and protected by galvanized iron or steel pipe of size 32mm dia, light grade and water pipe 20mm bore GI medium grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Part I of 2009 and also including making test point for testing of earthing made out of gun metal or phosphorous bronze size 75x75x25 mm complete. Note : On testing after completion of earthing if desired earth resistance below 5 ohms is not achieved, the earthing will be redone at no extra .cost.
M&L for providing & fixing/laying of 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer including excavation and re-filling etc. as required.
S & F installation , testing and commissioning pressure die-cast aluminium housing with high power LED bldg security light fitting with IP-66 , 1x 25 Watt , fixed in position with existing 40 mm dia light grade GI Pipe duly painted MS FI 40 x6mm clamps with nut and bolts , washers making electrical connection with and including three core 16/0.20 mm copper conductor flexible cable from connector to fitting complete all as specified and directed.
Supply and fixing PVC conduit 20mm dia, medium grade, ISI marked for telephone cable
Taking down DBs/industrial socket with MCBs all as directed by Engineer-in-Charge.
Taking down Submain wiring of any size all as directed by Engineer-in-Charge.
Taking down ceiling fan/exhaust fan of any size/sweep complete all as directed by Engineer-in-Charge.
Hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan complete all as directed by Engineer-in-Charge.
Hanging only exhaust and connecting up including provision of cable from ceiling rose or connector to fan complete all as directed by Engineer-in-Charge.
Taking Out old unserviceable electric panel of any size including electric connections and Supply, installation, Commissioning and testing LT panel board of size 1800 x 1200 x 300mm (Approx) for 3 phase, 4 wire, 415 Volts, AC, 50 Hz supply, Outdoor cubical type, dust and vermin proof, pedestal mounting type suitable for Outdoor applications having suitable shape/ size canopy on top, made out of 3.15 mm thick MS sheet with using 40mm x 40mm x 5mm angle iron frame and supports, duly finished with powder coated of approved colour over a coat of red oxide primer all over steel surfaces complete with separate compartment of suitable shape and size with shutter and locking arrangement for each switchgear and including PCC work for fixing panel legs 45 cm above ground level and bus bar of copper conductor suitable shape and size of 950 Amps rating including taking out end connections of the existing cables and fixing the cable with the panel using new lugs and glands of suitable size including following switchgear & controls.
Supply, laying, jointing and testing XLPE/ P.V.C insulated, armoured, heavy duty, aluminium conductor cable 1100 volts grade of any description and any make laid in trenches/ducts, floors, fixed to walls etc size of 70 sqmm 3.5 core complete all as specified and directed
M & L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed . NOTE: - Punned thickness shall be measurement & paid.
Supplying & Laying Sub Class `B’ bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection all as specified and directed
M & L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate . Earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt upto 1.5 meter depth all around the earth plate and connected to earth lead of GI strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel and thimbles and other end of the earth lead connected to Plant/equipment and protected by galvanized iron or steel pipe of size 40mm dia, light grade and water pipe 20mm bore GI medium grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of 2009 and also including making test point for testing of earthing made out of gun metal or phosphorous bronze size 75x75x25 mm complete. Note : On testing after completion of earthing if desired earth resistance below 5 ohms is not achieved, the earthing will be redone at no extra cost.
M/S YOGANSH CONSTRUCTION CO. (BID ID -3276018)
Allied Agencies (BID ID -3277898)
M/s Himgiri construction (BID ID -3274048)
NAKSHA ENTERPRISES (BID ID -3277729)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .