Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹19.7 L+₹87,466 (4.66%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹21.8 L+₹3.0 L (16.0%)Rejected-Finance 93 61 AGARWAL FARM MANSAROVER JAIPUR 302020 | JAIPUR | JAIPUR | RAJASTHAN | 302020 | L3 | Rejected-Finance L3 | |
| 4 | L4₹23.3 L+₹4.6 L (24.3%)Rejected-Finance | L4 | Rejected-Finance L4 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
19 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE JAIPUR
Military Engineer Services, HQ Commander Works Engineer, Kalyan Marg, Banipark, Jaipur-06
REPAIR AND MAINT OF HT 11 KV AND 33 KV NETWORK INCLUDING MAINT OF BREAKER PANELS, RMUs, VCBs AND OTHER ACCESSORIES AT ZONE-III AREA UNDER GE (S) JAIPUR
2024_MES_666743_1
CWE/JPR(S)/82323/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
JAIPUR
As per NIT
8 documents required · 8 mandatory
₹0
₹50,000
Yes
1 Feb 2025
19 Jul 2024
21 Sept 2024
19 Jul 2024
19 Sept 2024
3 Aug 2024
19 Jul 2024 - 2 Aug 2024
Amount
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation etc or for shafts, wells, cess pits, manholes, pier holes, laying cables erection of poles / struts/stays etc not exceeding 10 Sqm on plan, not exceeding 1.5 metre in depth and getting out in any type of soil complete all as specified and directed.
M&L for sand cushioning to PVC underground cable with tibba sand and punning to provide a required cover complete all as specified and directed. Note:- Punned thickness shall be considered for payment purpose
Supplying and laying un-reinforced precast cable covers class HV, type I, peak, size 300mm x 180mm x 40mm complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm in any type of soil complete all as specified and directed.
Removing of excavated material (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50metre above the starting point complete all as specified and directed
M&L for Surface Dressing/ Cleaning of various 11/33 KV sub-stations free from vegetation of any type including trimming of tree branches, bushes, creepers, etc. also on fencing complete all as specified & directed. Note: The frequency of surface dressing shall not be less than 1 months
S&F in repair post insulator with GI post for holding fixed /moving contact assembly suitable for Air break gang operated switch 200 Amps, 11000 volts grade complete all as specified and directed
S&F in repairs lightening arrestor expulsion type complete with all fittings transmission class discharge capacity 65 KA suitable for 11000 volts complete all as specified and directed
S&F in repairs lightening arrestor expulsion type complete with all fittings transmission class discharge capacity 65 KA suitable for 33000 volts complete all as specified and directed
Supply & Fix in repair Air break switch 200 amp, for HT 11 KV, 50 Hz AC, Gang Operated, triple pole, outdoor, horizonal / vertical mounting type (ISI marked), mounted on insulators and MS frame work, with fuse carriers & HT fuses, manually operated from ground level with locking arrangment including 65 mm pad lock with two keys, necessary electric connections, etc complete all as specified and directed
S&F in repair of metallic (brass/alloy steel) fixed contact set single pole including fixing screwed nuts and washers suitable for air break gang operated switch of cap 200/400 amp 3 pole 11000 volts grade complete all as specified and directed
S&F in repair of metallic (brass/ alloy steel) moving contact set single pole including screws, nuts and washers suitable for air break gang operated switch of capacity 200/400 Amp 11000 volts including taking down complete all as specified and directed
S&F in repair of flexible copper straps including fixing screws, nuts and washers suitable for air break gang operated switch 200/400 amps 11000 volts for single phase complete all as specified and directed
M&L for shifting of trolley mounted transformer of any capacity any location within the station to location of defective transformer and connecting to HT cable 11000 volt in coming from existing source and LT outgoing cables complete all as specified and directed NOTE: T&P required for loading, unloading, shifting transporting the trolley mounted transformer back to E/M yard is deemed to be inclusive of the quoted rate.
M&L for disconnecting of defective transformer (indoor/outdoor type) 11KV/433 volts copper/ Aluminium wound from power mains and dismantling the same from 2/4 pole structure/ platform mounted and transporting the same to authorised workshop and opening the transformer cover, draining out of transformer oil and keep safely for reuse after filtration, assembling, removing of the burnt parts ie tape, paper insulating strings etc gently and carefully, washing of the dust, rust and dirt from all parts including taking out HT/LT leg coil core tank and cooling tubes, painting the inner side tank by zinc chromate paint and preparing the same for re-assembling after carrying out required repair and installation on existing 2/4 pole structure/ platform with necessary fixing arrangement including connecting up electrically, commissioning and testing all as directed by Engineer-in-Charge and specified in particular specification of the following capacity :-
(a) 63 KVA to 125 KVA capacity
(b) 150 KVA to 250 KVA capacity
(c) 315 KVA to 400 KVA capacity
NOTE for item No 15.01 to 15.03 (i) Repair cost is deemed to be included in the quoted rate; and Unserviceable items required to be replaced shall be measured and paid separately. (ii) The burnt transformer oil shall be contractor property & any new oil shall be measured and paid separately under respective item. (iii) The coils and the oil shall be inspected for repair/replacement by department rep.
Supply only HT coil with suitable insulation for copper wound transformer of any type / capacity complete all as specified and directed.
Supply only LT coil with suitable insulation for copper wound transformer of any type / capacity complete all as specified and directed.
Supply only HT porcelain bushing complete with brass/tinned copper rod with nuts and gasket set complete all as specified and directed for following capacity transformer :-
(a) 63 KVA to 125 KVA capacity
(b) 150 KVA to 250 KVA capacity
(c) 315 KVA to 400 KVA capacity
Supply only LT porcelain bushing complete with brass/tinned copper rod with nuts and gasket set complete all as specified and directed for following capacity transformer :-
(a) 63 KVA to 125 KVA capacity
(b) 150 KVA to 250 KVA capacity
(c) 315 KVA to 400 KVA capacity
S&F in repair breather with silica gel in replacement (for transformer of any type/cap) with end fitting complete all as specified and directed
M&L for painting two coat of paint on steel structural members of HT 2/4 pole structure over one coat of red oxide with brush/spray at site including scrapping/ removing paint from old surfaces and preparation of surface complete all as specified and directed.
M&L for preparation of old surfaces, removing, cleaning of oil, grease etc. and painting with two coats of synthetic enamel paint of grey colour by spray complete all as specified and directed of following capacity transformer :-
(a) 63 KVA to 125 KVA capacity
(b) 150 KVA to 250 KVA capacity
(c) 315 KVA to 400 KVA capacity
M&L for refilling fresh Silica Gel into the breather including removal of unserviceable item complete all as specified and directed.
Supply and laying, stone aggregate of 40-80mm size, upto thickness of 20 cm laid over & including 15cm thick sand cushioning (river sand) at sub-stations/electric yards including levelling etc. The aggregate and sand should be supported by the curved stone duly coloured in white respectively at the edge of the perimeter of cable duct of switchyard/installation etc. complete all as specified and directed. Note:-(i) It should be ensured that before laying stone aggregate and sand the grass or unwanted bushes shall be treated checmically to remove the unwanted vegetation and surface of the switchyard/installation should be made totally free from the existing stone aggregates without destroying the cable, earthpit etc at the installation.
M&L for disconnecting of defective transformer of any type of capacity 25 KVA, 33 KV/433 volts copper/ Aluminium wound from power mains and dismantling the same from 2/4 pole structure/ platform mounted and transporting the same to authorised workshop and opening the transformer cover, draining out of transformer oil and keep safely for reuse after filtration, assembling, removing of the burnt parts ie tape, paper insulating strings etc gently and carefully, washing of the dust, rust and dirt from all parts including taking out HT/LT leg coil core tank and cooling tubes, painting the inner side tank by zinc chromate paint and preparing the same for re-assembling after carrying out required repair and installation on existing 2/4 pole structure/ platform with necessary fixing arrangement including connecting up electrically, commissioning and testing all as directed by Engineer-in-Charge and specified in particular specification. NOTE (i) Repair cost is deemed to be included in the quoted rate; and Unserviceable items required to be replaced shall be measured and paid separately. (ii) The burnt transformer oil shall be contractor property & any new oil shall be measured and paid separately under respective item. (iii) The coils and the oil shall be inspected for repair/replacement by department rep.
M&L for calibration and tetting of protection relay of any make or type fitted on 33 KV breakers panels (IDMT relay, transformer Buccholz relay, WTI, OTT, PRV, control panel at MRS, 61 Cav, Ajaymeru S/Y and certain other locations as per IS and code of practice to ensure NO ERROR including setting for earth fault, over current with trip time delay in accordance to feeder load and other parameters of site including time grading of the same with JVVNL setting to ensure that fault shall not travel to nearest source feeder; including minor repairs, replacement of wiring etc & submit test certificate of above relay testing and calibration etc complete all as specified and directed. (a) Control and Relay panel of 33 KV breaker - 04 Nos. (b) 33/11 KV, 5 MVA transformer relay control panel -04 Nos Note:- The frequecny of testing and calibration shall be done twice as change of season between winter to summer and vice versa.
M&L for calibration and testing of protection relay of any make or type fitted on 11 KV VCBs (details given below) as per IS and code of practice to insure NO ERROR including setting for each fault over current with trip time delay in accordance to feeder load and other parameters of site including grading with incomer panels at MRS etc complete all as specified and directed. Out going / Incoming 11KV - 12 Nos
M&L for calibration and testing of protection relay of any make or type fitted on 11 KV 4 Way RMU as per IS and code of practice to insure NO ERROR including setting for each fault over current with trip time delay in accordance to feeder load and other parameters of site including grading with incomer panels at MRS etc complete all as specified and directed.
M&L for calibration and testing of protection relay of any make or type fitted on 11 KV 6 Way RMU as per IS and code of practice to ensure NO ERROR including setting for each fault over current with trip time delay in accordance to feeder load and other parameters of site including grading with incomer panels at MRS etc complete all as specified and directed.
M&L for calibration and testing of protection relay of any make or type fitted on 33 KV 3 Way RMU as per IS and code of practice to ensure NO ERROR including setting for each fault over current with trip time delay in accordance to feeder load and other parameters of site including grading with incomer panels at MRS etc complete all as specified and directed.
NOTE FOR ITEM NO. 26 to 30 (i) The calibration and setting must be completed within 30 days from the date of commencement to avoid any major break down. (ii) The calibration and setting shall be carried out by only qualified and experienced engineer. (iii) The relay setting shall be carried out once in a three month as per load and site conditions to avoid and any fault travel to next adjacent source breaker and shall be monitored regularly. (iv) For payment purpose the payment for calibration of relay once in 06 months & setting of relay twice in 06 months is considered as each job. The cost of monitoring is also included in the item rate. (v) Certificate of rep of authorised person should be submitted before calibration / setting the VCBs. The record of calibration / setting of relays shall be submitted by the contractor.
M&L for Disconnecting of HT supply from 11 KV VCB of capacity upto 1250 Amp -12 Nos. for overhauling of trolly mechanism and carry out repair works, servicing complete with decarbonizing the contact points, cleaning with CRC solution etc. All indicating lamp of the panel replaced if necessary, breaker control switch, digital Amp meter, Volt meter should be replaced if in case found defective, testing after repair complete all as directed Note:- Servicing will be done twice at the interval of 3 months and this will be considered as one job.
M&L for Disconnecting of HT supply from 11 KV 4 way RMU of capacity upto 1250 Amp -1 Nos. for overhauling of trolly mechanism and carry out repair works, servicing complete with decarbonizing the contact points, cleaning with CRC solution etc. All indicating lamp of the panel replaced if necessary, breaker control switch, digital Amp meter, Volt meter should be replaced if in case found defective, testing after repair complete all as directed Note:- Servicing will be done twice at the duration of 3 months and this will be considered as one job.
M&L for Disconnecting of HT supply from 11 KV 6 way RMU of capacity upto 1250 Amp -1 Nos. for overhauling of trolly mechanism and carry out repair works, servicing complete with decarbonizing the contact points, cleaning with CRC solution etc. All indicating lamp of the panel replaced if necessary, breaker control switch, digital Amp meter, Volt meter should be replaced if in case found defective, testing after repair complete all as directed. Note:- Servicing will be done twice at the interval of 3 months and this will be considered as one job.
M&L for Disconnecting of HT supply from 33 KV VCB/SF 6 CB-4 Nos with panel capacity of 1250 Amp outdoor type for overhauling of mechanism and carry out repair works, servicing complete with decarburizing the contact points, cleaning with CRC solution etc testing after repair complete all as specified and directed Note:- Servicing will be done twice at the interval of 3 months and this will be considered as one job. Note:- Parts replaced of VCB shall be measured and paid separately under respective items.
Replacement of following parts for Srl item Nos 31 & 34 above :-
Supply only Shunt Trip Coil & closing Coil, operating voltage 24 Volts DC suitable for 11 KV VCB/ SF6 gas breaker make CG / Alstom & ABB
Supply only TNC switch suitable for 11 KV VCB.
Supply only digital type Ammeter/Volt Meter for 11 KV VCB.
S&F PT fuse 3.15 Amp for 11 KV, VCB.
S&F in replacement of spring charge motor assembly operating voltage 220 V AC/ DC suitable for 11 KV VCB of Areva/CG complete with required fixing and wiring arrangements complete and all as directed by Engr-in-charge.
S&F in replacement LED/Neon Lamps with holder size 22.5 mm of different colour RED / GREEN / AMBER / WHITE / BLUE / (24 V to 220 V AC/DC).
M&L for rectification, detection of gas leakage & refilling of the same in compatible to the pressure marked by the OEM complete all as specified and directed.
M&L and T&P for tightening of jumbers and busbar and and greasing of GOD at four/two pole structures and tightening of cable at HT and LT at both end of transformers complete of all as specified and directed.
Supply only VCB interuptor for 11KV VCBs or RMUs complete of all as specified and directed.
Supply only numerical relay having overcurrent, earth fault protection, three phase symmetrical fault etc. all as specified and directed. Make:- CG Cat part :-CGI 14 N / Schneider or equivalent as approved by GE Note : After repair of HT equipments i.e. transformer. VCBs, RMUs, Relays shall got tested from authorised agency or testing officer detailed by accepting officer and complete test report will be enclosed with the final bill.
S&F HT/LT cable route indicators of cast iron of suitable size along the cable trench including painted and grouted in ground in PCC 1:2:4 type B1 using 20 mm graded aggregate complete all as specified and directed by Engr in Charge.
Supply, laying and commissioning XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 11000 volts grade IS-7098 marked, suitable for HT 11 KV (E) System laid in trenches/ ducts/ encased in GI pipe/ fixed to poles including jointing & testing complete all as specified and directed of following cross sectional area :-
(a) 95 Sqmm, 3 core cable
(b) 185 Sqmm, 3 core cable
M&L for cable end termination, jointing kit, HT 11 KV grade, heat shrinkable, outdoor type complete with jointing material suitable for HT XLPE cable 3 core 11 KV grade complete all as specified and directed of following sizes :-
(a) 95 Sqmm, 3 core cable
(b) 120 to 185 Sqmm x 3 core
M&L for cable straight through, jointing kit, HT 11 KV grade, heat shrinkable, complete with jointing material suitable for HT XLPE cable 3 core 11 KV grade complete all as specified and directed of following sizes :-
(a) 95 Sqmm, 3 core cable
(b) 120 to 185 Sqmm x 3 core
M&L for cable end termination, jointing kit, HT 11 KV grade, heat shrinkable, indoor type complete with jointing material suitable for HT XLPE cable 3 core 11 KV grade complete all as specified and directed of following sizes:-
(a) 95 Sqmm, 3 core cable
(b) 120 to 185 Sqmm x 3 core
M&L for cable end termination, jointing kit, HT 33 KV grade, heat shrinkable, outdoor type complete with jointing material suitable for HT XLPE cable 3 core 33 KV grade for cable size 300 sqmm 3 core complete all as specified and directed.
M&L for cable, jointing kit, HT 33 KV grade, heat shrinkable, straight through type complete with jointing material suitable for HT XLPE cable 3 core 33 KV grade for cable size 300 sqmm 3 core complete all as specified and directed.
Supply & filling of transformer oil in transformer installed in situ at site for toping up the level of oil having dielectric strength >65 KV during filling after initial filtration conforming to IS-335 complete all as specified and directed. MAKE- POWER / INSOLE / UNIVERSAL / SAVITA NOTE: Transformer oil shall be supplied in sealed container and empty barrel of transformer oil will be deposited by contractor in E/M store yard.
M&L for Dehydration /filtration of transformer oil existing transformer installed at site with portable plant to improve the dielectric strength 65 KV including testing of dielectric strength after dehydration and filtration at site complete all as specified and directed. NOTE: Pre-heated oil shall be topped up as required at site before the process; oil will be measured and paid separately under respective item.
M&L for fault finding in U/G cable using fault locating machine on requirement for 33/11 KV HT cables of any type/size complete all as specified and directed.
S&F insulated single core aluminium unarmoured cable for HT jumpering of size 50-70 sqmm complete all as specified and directed.
S&F insulating rubber mats of size (1x2) mtr at substaions of 33KV of 25mm of die electric strength not less than 40 KV according to IS 5424:1969 etc complete all as specified and directed.
M&L for testing of CT and PT and its oil level of any make or type fitted in 33 KV switchyard (details given below) as per IS and code in accordance to feeder load and other parameters of site including grading with incomer panels at MRS (a) Out going / Incoming 33 KV- 05 Nos (b) Testing and tightening of bus bar of 33KV switchyard alongwith testing of insulators of 33kV from Incomer to the VCBS of 11KV (c) Checking and testing of insulators of 33 KV swithcyard complete. NOTE: (i) The testing and setting must be completed with in 3 weeks from the date of commencement placed to avoid major break down. (ii) The testing and setting shall be carried out by only qualified and experienced engineer. (ii) The testing includes comprehensive testing from the supply received at Combined CT PT to the incomer of the Power transformers (v) Certificate/report of rep of authorised person should be submitted after testing the CT and PT. The record of testing/ setting of CT and PT and Switchyard of 33KV shall be submitted by the Contractor.
Schedule of Credit
M/s Prakash Enterprises (BID ID -3092720)
M/S Anil Enterprises (BID ID -3094677)
S.R.Enterprises (BID ID -3100792)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .