Loading…
Loading…
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
28 Aug 2026, 6:00 pm4d left
Garrison Engineer
Garrison Engineer (U) Chandimandir Pin Code 134107
REPAIR AND MAINTENANCE OF LT DISTRIBUTION SYSTEM AND CONNECTED ITEMS OF WORKS AT E/M INSTALLATION AT COMD HOSP (WC) UNDER GE (U) CHM
2026_MES_781678_1
GE(U)/CHM-36/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE (U) Chandimandir
Please refer to tender documents
5 documents required · 5 mandatory
₹500
GE (U) Chandimandir
₹40,000
Yes
28 Aug 2026
30 Jul 2026
1 Sept 2026
30 Jul 2026
28 Aug 2026
14 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, laying, connecting, testing & commissioning as in replacement of Power Cables, Aluminium Stranded Conductor 50 sqmm, 3.5 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098 (Part 1) complete laid in trenches / floors / ducts/ fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings/LT OH Line and testing on completion complete all as specified and directed by Engineer-in-Charge. | 80 | RM | - | - |
| 2 | Supply, laying, connecting, testing & commissioning as in replacement of Power Cables, Aluminium Stranded Conductor 70 sqmm, 3.5 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098 (Part 0) complete laid in trenches / floors / ducts/ fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings/LT OH Line and testing on completion complete all as specified and directed by Engineer-in-Charge. | 100 | RM | - | - |
| 3 | Supply, laying, connecting, testing & commissioning as in replacement of Power Cables, Aluminium Stranded Conductor 95 sqmm, 3.5 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098 (Part 1) complete laid in trenches / floors / ducts/ fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings/LT OH Line and testing on completion complete all as specified and directed by Engineer-in-Charge. | 150 | RM | - | - |
| 4 | Supply, laying, connecting, testing & commissioning as in replacement of Power Cables, Aluminium Stranded Conductor 120 sqmm, 3.5 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098 (Part 0) complete laid in trenches / floors / ducts/ fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings/LT OH Line and testing on completion complete all as specified and directed by Engineer-in-Charge. | 250 | RM | - | - |
| 5 | Supply, laying, connecting, testing & commissioning as in replacement of Power Cables, Aluminium Stranded Conductor 185 sqmm, 3.5 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098 (Part 0) complete laid in trenches / floors / ducts/ fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings/LT OH Line and testing on completion complete all as specified and directed by Engineer-in-Charge. | 500 | RM | - | - |
| 6 | Excavation in trenches not exceeding 1.5 M wide and not exceeding 1.5 M deep and getting out in soft / Loose soil for laying/removing of cable complete all as specified and directed by Engr-in-Charge. | 250 | Cum | - | - |
| 7 | Returning filling in including spreading, levelling, watering and well ramming, in layers not exceeding 25cm in soil obtained from excavation complete all as specified and directed by Engr-in-Charge. | 157 | Cum | - | - |
| 8 | Removal of surplus soil to a distance not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above starting point. Complete all as specified and directed by Engr-in-Charge. | 93 | Cum | - | - |
| 9 | M&L sand cushioning for underground cable 8cm below and 15cm above the cable with clean dry river sand in trenches including spreading, levelling etc. complete all as specified and directed by Engr-in-Charge. Note:- Punned thickness only will be measured for the purpose of payment. | 70 | Cum | - | - |
| 10 | Supply and laying reinforced precast concrete cable cover class LV type-1 flat, size 250mmx150mmx40mm as protection to LT cable complete all as specified and as directed. | 5,800 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.23 MB
Tenderdocuments36.pdf
Tender Documents • 0.83 MB
BOQ_875667.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].