Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.0 CrAccepted-AOC | ₹12.0 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹14.3 CrRejected-AOC | ₹14.3 Cr | L2 | Rejected-AOC L2 |
| 3 | Rejected-Technical PLOT NO 35 S NO 55 2B GAYATRI NAGAR DEOPUR DHULE | - | - | Rejected-Technical Section 2- 4.4B (a) (ii), 4.2(g) |
| 4 | Rejected-Technical | - | - | Rejected-Technical Section 2- 4.1.1, 4.2(g) |
Tender Value
₹14.7 Cr
EMD Value
₹13.9 L
Closing Date
16 Dec 2021, 5:00 pmClosed
CHIEF ENGINEER, JSRRDA
3RD FLOOR FFP BUILDING DHURWA, RANCHI JHARKHAND 834004
Construction and Maintenance of Roads under PMGSY (RCPLWEA) Scheme
2021_CEJHR_114845_84
e-Tender No.- 01 /2021 RCPLWEA
Open Tender
Civil - Roads and Bridges
455 days
SARAIKELA KHARSAWAN
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
₹13.9 L
11 May 2022
1 Dec 2021
17 Dec 2021
1 Dec 2021
16 Dec 2021
1 Dec 2021
Amount
Details
ROAD-1 Baruhatu to Gomiadih to Meromjanga to Pandadih , BLOCK-Kuchai, DIST - Saraikela Kharsawan, LENGTH- 17.239 KM. Setting out(i) Construction of Reference & Working Benchmark = 18 Nos. & 69 Nos. RespectivelySOR Item No.-1.16
(ii) Construction of Reference Pillars/Burjees = 690 NosSOR Item No.-1.16
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201.SOR Item No.-2.2
Dismantling Brick Soling/Tile Work Dismantling of existing structures like culverts, bridges, retaining walls and other structures comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202.SOR Item No.-2.6
Scarifying the existing bituminous road surface and disposal of scarified material with a lift upto 3 m and lead upto 1000 m as per Technical Specification Clause 301.4.SOR Item No.-3.2
Excavation for roadway in soil using manual means for carrying of out earth to embankment site with a lift up to 1.5 m and lead up to 50m as per Technical Specification Clause 302.3.SOR Item No.-3.5 (I)
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5.SOR Item No.-3.3
Construction of Embankment with Material Obtained from Borrow Pits Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 250m as per Technical Specification Clause 301.5SOR Item No.-3.4 (B)
Construction of embankment with approved material obtained from borrow pits with a lift up to 1.5m transporting to site, spreading grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead up to 100 m as per Technical Specification Clause 301.5SOR Item No.-3.5 (ii)
Construction of Subgrade and Earthen Shoulders Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead from 250 m to 500 m as per Technical Specification Clause 303.1.Subgrade (Earthen to BT) Subgrade (Earthen to PCC) SOR Item No.-3.14 (C)
Construction of granular sub-base by providing well graded material (Grading II) , spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with three wheel 80-100 kN static roller capacity to achieve the desired density, complete as per Technical Specification Clause 401SOR Item No.-4.1.401(Aii)
Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406.SOR Item No.-4.9
Prime Coat Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502SOR Item No.-5.1 (i)
Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 50SOR Item No.-5.2 (iii) 503
Semi-Dense Bituminous Concrete(5.7 of RCD) (I) Grading I: 13 mm (Nominal Size) Providing and laying semi dense bituminous concrete with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 4.5 to 5 per cent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 508 complete in all respects.SOR Item No.-5.2 (iii) 503
Construction of un-reinforced, dowel jointed at expansion and construction joint only, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge/culvert and construction joints, admixtures as approved, curing of concrete slabs for 14-days, using curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification Clause 1501SOR Item No.-6.4
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 15 SOR Item No.-11.4 (II)
Providing hard shoulder with localy available GSB material.......as per specification and direction of E.I. SOR Item No.-4.11
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.SOR Item No.-11.1
Plain Cement Concrete M10 (1:3:6 nominal mix) in levelling course below open foundation of head wall as per drawing & Technical Specification Clause 1109SOR Item No.-11.4 (i)
Stone masonry work in cement motar in foundation complete as per drawing and technical specifications clauses 702, 704, 1202 & 1203 Random Rubble Masonry In 1:4 cement mortar SOR Item No.-11.6 III (ii)
Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 Random rubble masonry In 1:4 cement mortar SOR Item No.-12.4 III (ii)
Providing Concrete (M20) for plain/reinforced concrete in head wall comp;ete as per drawings and techical sepecifications clause 802,803, 1202 & 1203SOR Item No.-11.4 (iii)
Providing Cover Slabe icluding rainforcement on top of drain as per specifications and direction of E/I.
Construction of granular sub-base by providing well graded material (Grading II) , spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401
Stone masonry in cement mortar (1:4) random rubble masonry for foundation complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapaets clause 1106. 1000 mm dia (Single row)SOR Item No.-9.3 (B)
Type B (First Class) Bedding laying (first Class) bedding on well compacted sand, moorum or approved granular material as per clause 1005 (ii)SOR Item No.-11.2 (i)
Boulder soaling work in cement motar in foundation complete as per drawing and technical specifications clauses 702, 704, 1202 & 1203SOR Item No.-11.6 (ii)
Plastering with Cement Mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification.SOR Item No.-12.3
Backfilling in Foundation trenches as per drawing and technical specification clause 1108.SOR Item No.-11.2 (II)
Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfacesSOR Item No.-10.5
Providing and laying boulder Solaing for bed protection with stone boulders of minimum size and weight as per Table 1300.1, no fragment weighing less than 25 kg laid dry complete as per drawing and technical specifications Clause 1301SOR Item No.-14.1
RCC M-25 Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5SOR Item No.-13.1 (II)
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specificationsSOR Item No.-13.2
Pointing with cement mortar (1:3) on stone work as per drawing and technical specification Clauses 613.3 and 1204 SOR Item No.-12.2
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification.SOR Item No.-12.11
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7SOR Item No.-12.9
RCC GRADE M-25 Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1204SOR Item No.-11.4 (V)
Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 @ @ 100 kg/cum of RCC + 80 kg/cum of PCC of cutoff wallSOR Item No.-12.6
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8SOR Item No.-12.1
Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3SOR Item No.-13.6
Drainage spouts complete as per drawing and technical specifications Clause 1209SOR Item No.-13.1
Providing pressure relief pipes 100 mm dia in bottom slab of box cell on a filter media base of 500 mm x 500 mm as per drawing and technical specification Clause 1205.5.7SOR Item No.-12.14
Providing PCC M20 Architectural Coping on the top of wing wall, return wall etc. complete as per drawing and technical specification Clause 615.SOR Item No.-12.5
Backfillling in foundation trenches as per drawing and technical specification Clause 1108SOR Item No.-11.2 (I)
Dismantling of Structures Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. By Manual Means Plain Cement Concrete SOR Item No.-2.5 I (B)
Dismantling of Structures Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. By Manual Means Reinforced Cement Concrete SOR Item No.-2.5 I (C)
Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works as per Technical Specification Clause 202. Above 600 mm to 900 mm dia Hume pipeSOR Item No.-2.13 B
Repairing of old damaged Hume pipe Culvert by way of Clearing, Cleaning, Erosion repair, repairs to cracks, parapet wall and protection work as per drawing and technical specification Clause 1908 SOR Item No.-15.7 (I)
Repairing of old damaged Slab Culverts by way of clearing, Cleaning, Erosion repair, repairs to cracks, parapet walls and Protection works as per drawing and technical specification Clasue 1908SOR Item No.-15.7 (II)
Repairing of old damaged RCC Bridge by way of clearing, Cleaning, Erosion repair, repairs to cracks, parapet walls and Protection works as per drawing and technical specification Clasue 1908SOR Item No.-
Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 1204SOR Item No.-12.3
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 17035th Kilometre Stone (Pre-cast) SOR Item No.-10.1(III)
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703Ordinary Kilometer Stone (Pre-cast) SOR Item No.-10.1(III)
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703200m Stone (Pre-cast) SOR Item No.-10.1(III)
Boundary Pillar Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704At outer side of H-Curve & @ 1.50m c/c both side at heigh embankment SOR Item No.-10.11
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 SOR Item No.-10.16
PMGSY Logo Board
Maintenance Board
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 SOR Item No.-10.2 A (1)(ii) 600 mm equilateral triangle Left Hand & Right Hand Curve
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 SOR Item No.-10.2 A (1)(vii) 900 mm side octagon Stop Sign
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 SOR Item No.-10.2 A (1)(vii) Speed Limit (600 MM Circular) Speed Limit (600 MM Circular)
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 SOR Item No.-10.2 A (1) Hectometer Post
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 SOR Item No.-10.2 A (1)(v) 600 mm x 450 mm rectangular
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 . The finished surface to be level , uniform and free from streaks and holes. SOR Item No.-8.13
Metal Beam Crash Barrier Metal Beam Crash BarrierType-A "W" : Metal Beam Crash Barrier Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick comugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process all fittings to conform to IS : 1367 and IS : 1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810 (Rate taken from SOR of RCD, Jharkhand 2018)SOR Item No.-8.23 (A) 810
Maintainance for 1st year
Maintainance for 2nd year
Maintainance for 3rd year
Maintainance for 4th year
Maintainance for 5th year
Labour Cess @ 1%
saptsatee construction
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf