Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 LAccepted-Finance 30 OPP ALOK PRESS GHATI BADBHUNJA CHAMELI ROAD BHOPAL BHOPAL MADHYA PRADESH 462001 UDYAM MP 10 0044621 | BHOPAL | MADHYA PRADESH | 462001 | ₹1.1 L | L1 | Accepted-Finance L1 |
| 2 | L2₹1.4 LAccepted-Finance D NO 17 143 APOLLO GARDEN MADANADAR KUDIERUPPU NEAR KUMARAPURAM JN TIRUNELVELI 627 133 | TIRUNELVELI | TAMIL NADU | 627133 | ₹1.4 L | L2 | Accepted-Finance L2 |
| 3 | L3₹5.8 LAccepted-Finance SALEM | SALEM | ₹5.8 L | L3 | Accepted-Finance L3 |
| Rank | Bidder | Total Amount |
|---|---|---|
| L2 | APOLLO TRANSFORMERS AND FILTERS Bid ID 1604167 | ₹1,39,163 |
| L3 | Delta Roto Tech Private LimitedV Bid ID 1604196 | ₹5,85,000 |
| L1 | R K ELECTRICALS Bid ID 1600738 | ₹1,13,887 |
| Sl No | Description | Qty | Unit | APOLLO TRANSFORMERS AND FILTERS L2 | Delta Roto Tech Private LimitedV L3 | R K ELECTRICALS L1 |
|---|---|---|---|---|---|---|
| 1.00 | Charges for disconnection of HV / LV Power cables, earth flats and releasing the old transformer oil from the tank, Dismantling the top cover of the transformer and Reconnecting the same. | 1 | Nos | 7,401 ₹7,401 | 65,000 ₹65,000 | 6,056 ₹6,056 |
| 2.00 | Charges for complete cleaning of the Transformer Core, Winding , Conservator tank and Sludge removing, Complete cleaning of the tank and removing the old gasket, Complete cleaning of the Tap switch and attending defects if any | 1 | Nos | 15,330 ₹15,330 | 42,500 ₹42,500 | 12,543 ₹12,543 |
| 3.00 | Charges for dismantling of HV/LV Bushings, Providing New Gasket at top cover, HV/LV Bushing, Buchholz Relay and conservator tank & Re-erection of HV/LV Bushings & Fixing up the top cover | 1 | Nos | 6,789 ₹6,789 | 48,500 ₹48,500 | 5,554 ₹5,554 |
| 4.00 | Charges for cleaning, servicing of Buchholz relay, MOG relay, oil level gauge. | 1 | Nos | 7,062 ₹7,062 | 28,500 ₹28,500 | 5,778 ₹5,778 |
| 5.00 | Charges for refilling the new transformer oil in the transformer tank through oil filter machine. | 1 | Nos | 2,244 ₹2,244 | 18,500 ₹18,500 | 1,836 ₹1,836 |
| 6.00 | Charges for hot oil circulation till the IR value of the transformer winding & breakdown value of the oil reaches the required level and attending to the connected & related works. | 3 | DAYS | 10,856 ₹32,568 | 45,000 ₹1,35,000 | 8,882 ₹26,646 |
| 7.00 | Charges for transporting of new transformer oil and Filter machine. | 1 | Nos | 10,074 ₹10,074 | 8,500 ₹8,500 | 8,243 ₹8,243 |
| 8.00 | Charges for painting the Entire Transformer with two coats of standard Grey enamel paint. | 45 | SQ.MM | 96 ₹4,320 | 2,250 ₹1,01,250 | 79 ₹3,555 |
| 9.00 | Lorry rental charges towards the transporting of the New Transformer oil from Central stores to Transformer yard and old Transformer oil from Transformer yard to Central stores. | 1 | Nos | 10,560 ₹10,560 | 25,000 ₹25,000 | 8,640 ₹8,640 |
| 10.00 | Crane rental charges towards loading and unloading, lifting of New and old Transformer oil drum from Central stores to Transformer yard and Transformer yard to Central stores. | 1 | Nos | 7,920 ₹7,920 | 9,500 ₹9,500 | 6,480 ₹6,480 |
Tender Value
Refer Docs
EMD Value
₹1,300
Closing Date
17 Feb 2026, 2:00 pmClosed
CHIEF ENGINEER/MTPS-I
CHIEF ENGINEER MTPS-I METTUR DAM
MTPS-I ES Circle EM-II SD-IIEmergency overhauling of 1 No Indo Tech Andrew yule make 1000 KVA 6.6KV 433V of CWPH area service Transformer
2026_EB_654639_1
CE-MTPSI-SE-ES-EM2-OT138-25-26
Open Tender
Electrical Works
7 days
MTPS-I/METTURDAM
AS PER TENDER SPECIFICATION
4 documents required · 4 mandatory
₹0
₹1,300
Yes
18 Feb 2026
11 Feb 2026
17 Feb 2026
11 Feb 2026
17 Feb 2026
11 Feb 2026
Charges for disconnection of HV / LV Power cables, earth flats and releasing the old transformer oil from the tank, Dismantling the top cover of the transformer and Reconnecting the same.
Charges for complete cleaning of the Transformer Core, Winding , Conservator tank and Sludge removing, Complete cleaning of the tank and removing the old gasket, Complete cleaning of the Tap switch and attending defects if any
Charges for dismantling of HV/LV Bushings, Providing New Gasket at top cover, HV/LV Bushing, Buchholz Relay and conservator tank & Re-erection of HV/LV Bushings & Fixing up the top cover
Charges for cleaning, servicing of Buchholz relay, MOG relay, oil level gauge.
Charges for refilling the new transformer oil in the transformer tank through oil filter machine.
Charges for hot oil circulation till the IR value of the transformer winding & breakdown value of the oil reaches the required level and attending to the connected & related works.
Charges for transporting of new transformer oil and Filter machine.
Charges for painting the Entire Transformer with two coats of standard Grey enamel paint.
Lorry rental charges towards the transporting of the New Transformer oil from Central stores to Transformer yard and old Transformer oil from Transformer yard to Central stores.
Crane rental charges towards loading and unloading, lifting of New and old Transformer oil drum from Central stores to Transformer yard and Transformer yard to Central stores.
Material cost a) 10 mm thick RC 70C 900 x 900 mm size
b) 8 mm thick RC 70C 900 x 900 mm size
c) 6 mm thick RC 70C 900 x 900 mm size
d) DA Grey paint
e) Rubber bushes for HV / LV Bushings
f) HT side bushing rod
g) Bold and nut
h) 20mm Brass valve
i) Breather 1KG
Consumables such as Cotton waste, Gada cloth, Thinner, Shellac, Teflon Tape, Emery sheet and Cleaning Brush
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.77 MB
BOQ_785118.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid