Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC OPPOSITE J K BANK BAROO NH1 HAIDERY COMPLEX BAROO KARGIL BAROO KARGIL LADAKH 194103 | KARGIL | LADAKH | 194103 | ₹1.4 Cr | L1 | Accepted-AOC ACCEPTED BEING L1 BIDDER |
| 2 | L2₹1.4 Cr+₹1.6 L (1.13%)Rejected-AOC NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | ₹1.4 Cr+₹1.6 L (1.13%) | L2 | Rejected-AOC NOT ACCEPTED |
| 3 | L3₹1.5 Cr+₹8.6 L (6.01%)Rejected-AOC POST BOX NO 539 JUNGLIGHAT P O SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | ₹1.5 Cr+₹8.6 L (6.01%) | L3 | Rejected-AOC NOT ACCEPTED |
| 4 | L4₹1.6 Cr+₹14.3 L (9.97%)Rejected-AOC 9 EZRA STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | ₹1.6 Cr+₹14.3 L (9.97%) | L4 | Rejected-AOC NOT ACCEPTED |
| 5 | L5₹1.6 Cr+₹18.0 L (12.6%)Rejected-AOC 84 B LOWER BURDWAN COMPOUND RANCHI 834001 JHARKHAND | RANCHI | JHARKHAND | 834001 | ₹1.6 Cr+₹18.0 L (12.6%) | L5 | Rejected-AOC NOT ACCEPTED |
Tender Value
₹1.4 Cr
EMD Value
₹2.1 L
Closing Date
20 Aug 2022, 6:00 pmClosed
CWE PANAGARH
HQ CWE PANAGARH, MES, PO - PANAGARH, DIST - BURDWAN, WB, PIN - 713420
ADDN/ALTN TO EXTERNAL ELECTRIC SUPPLY FOR SBI LINE MD ACCN AT PMS UNDER GE PANAGARH
2022_MES_537397_1
8794/E8
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
PANAGARH
Pl refer Tender Documents
7 documents required · 7 mandatory
₹1,000
GE PANAGARH
₹2.1 L
Yes
15 Sept 2022
12 Jul 2022
22 Aug 2022
12 Jul 2022
20 Aug 2022
6 Aug 2022
Amount
Supply and install, testing and commissioning of step down outdoor type copper wound, Oil immersed transformer of capacity 500 KVA (Level-2) complete (Platform mounted) with standard, fitting HT 11KV, 3 Phase, LT 433 volts, 3 phase 4 wire (Dyn11) with off load changer with range +7.5 to -7.5% in steps of 2.5% on HT side to vary secondary voltage all as per IS 1180 ,complete all as specified and as directed by Engrs-in-Charge. (1) Technical Details : (a) No load Voltage Ratio (Normal Tap) - 11000/433 V (b) Number of phases : Three (c) Frequency : 50 Hz (d) Type of Cooling : ONAN (e) Winding connections : The primary winding (HV) shall be connected in delta and secondary winding ( LV) shall be connected in star. (f) Vector Group : Windings shall be connected as per Vector symbol : Dyn11 (g) Neutral Earthing : The neutral point of Secondary (LV) winding shall be brought out to a separate insulated terminal and shall be solidly earthed. (h) Off Load Tap Changer of the transformer : Voltage tapping range on H.V. side will be (+7.5%) to (-7.5%) insteps of 2.5%. The tap changing switch shall be located in a convenient position so that it can be operated from ground level. The switch handle shall be provided with a locking arrangement along with tap position, enabling the switch to be locked in position. The tap position marking should increase in clockwise direction and there should be a back stopper in between tap position 1(+7.5%) & 7(-7.5%). (j) The percentage impedance at 75 °C & 50 Hz refer to the (normal) principal Tapping shall be 4.5%. (k) Losses : Minimum losses as per manufacturer. (l) Buchholz Relay (Double float type) (Having contacts for Alarm & Trip)
Item No 1 contd.... (2) Structural Details : The transformer shall be comprising of the following items :- (a) Externally hand operated off-circuit Tap Changer switch with position indicator and locking device. (b) Conservator with Oil gauge, filling Hole with plug and drain hole with plug. (c) undercarriage with four plain rollers. (d) Oil filling hole cum air release plug. (e) Drain Valve cum sampling valve. (f) Filter valve with Plug. (g) Lifting Lugs for Transformers. (h) Lifting lugs for Lid. (j) Earthing Terminals. (k) Thermometer Pocket (l) Silicagel Breather (m) Inspection Cover. (n) Explosion Vent. (o) 6 inches Dial type Thermometer with alarm, trip contacts and maximum temperature indicator with Metal Guard. (p) Rating Plate and Diagram Plate.
M & L for Steel tubular swaged poles complete with cast iron/MS base plate , finial taper plug , bolts , nuts & screws as specified type 410 SP-55 , 11 meter long complete including PCC (1:3:6) type C2 (using 40 mm stone graded stone aggregate in foundation and copying with PCC (1:3:6) type C1 (using 20mm stone aggregate), complete all as specified and as directed. Note : PCC anti climbing device, cross arms insulator, ACSR conductor and earth work measure and paid separately)
M&L for cross arms,bracings,supports,clamps and back plates fabricated from structural steel sections including nuts,bolts washers,welding ,bending cold or hot drilling holes for bolts,in any shape or size as indicated or directed and inclusive of one primer coat one under coat and one finishing coat of paint, complete all as specified and as directed.
M& L for Aluminium conductor steel reinforced for making busbar on 3 pole and 4 pole structures, complete all as specified and as directed.
Supply and fix HT 11KV,outdoor type gang operated air break switch suitable for horizontal or vertical mounting fixed type complete with 9 insulators of rating upto 400 amps, complete all as specified and as directed.
Material, Laying and testing 11000 volts (E) grade, heavy duty XLPE insulated cable, Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, XLPE Insulated, Insulation Screening with extruded Semi Conducting Compound in combination with Copper Tape, cores laid up, Pressure extruded PVC innersheath, galvanised flat steel strip armoured and overall PVC Sheathed Cable conforming to IS 7098 / (PART-II) 1985 with latest amendments of aluminium conductor cross sectional area 120 Sqmm 3 core, complete all as specified and as directed.
Material, Laying and testing 11000 volts (E) grade, heavy duty XLPE insulated cable, Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, XLPE Insulated, Insulation Screening with extruded Semi Conducting Compound in combination with Copper Tape, cores laid up, Pressure extruded PVC innersheath, galvanised flat steel strip armoured and overall PVC Sheathed Cable conforming to IS 7098 / (PART-II) 1985 with latest amendments of aluminium conductor cross sectional area 95 Sqmm 3 core, complete all as specified and as directed.
Supply and fix cable jointing kit for 11 KV grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 120 Sqmm to 185 Sqmm, complete all as specified and as directed.
Supply and fix cable jointing kit for 11 KV grade cable for out door termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 50 Sqmm to 95 Sqmm, complete all as specified and as directed.
Supply and fix cable jointing kit for 11 KV grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 50 sqmm to 95 sqmm, complete all as specified and as directed.
Dismantling of LT UG cable of size 10 sqmm 4 core to 16 sqmm 4 core, complete all as spcified and as directed.
Dismantling of LT UG cable of size 25 sqmm 3.5 core to 70 sqmm 3.5 core, complete all as spcified and as directed.
Dismantling of LT UG cable of size 95 sqmm 3.5 core to 240 sqmm 3.5 core, complete all as spcified and as directed.
Dismantling of Old bricks from trenches of old cable and staking aside, complete all as spcified and as directed.
Dismantling of Old LT feeder pillar boxes including demolishing PCC of base and filing the exvcavated area for making flat surface, complete all as spcified and as directed.
M&L for brickwork in CM (1:4) using sub class B bricks straight or curved on plan exceeding 6 Mtr mean radius ,complete all as specified and as directed by Engrs-in-Charge.
M&L for 15mm thick in cm (1:4) rendering on fair face of brick work finished even & smooth without using extra cement ,complete all as specified and as directed by Engrs-in-Charge.
M&L for 32x6mm galvanised iron strip including connection from earthing in continuation to end point, complete all as specified and as directed by Engrs-in-Charge.
Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x 600mm x 6mm thick buried directly in ground with earth pit not less than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized strip of 32 mm x 6 mm earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanized iron pipe 40 mm bore (light grade) including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting made out of 8 mm dia MS bar funnel wire mesh 20 mm bore galvanized iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR part 1 including testing on completion after demolition to existing one, complete all as specified and as directed.
S&F 100 mm bore GI tube, medium grade, ISI marked for protection of cable including necessary joint, complete all as specified and as directed.
S&F 40 mm bore GI tube, medium grade, ISI marked for protection of cable including necessary joint, complete all as specified and as directed.
Supply, laying and testing in trenches or passing through pipe 1100 volts grade, heavy duty XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor cross sectional area 500 Sqmm 3.5 core, complete all as specified and as directed. Note : (i) Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid separately under relevant item.
All as per item No 28 here-in-before but of size 240 sqmm 3.5 core, complete all as specified and as directed.
All as per item No 28 here-in-before but of size 185 sqmm 3.5 core, complete all as specified and as directed.
All as per item No 28 here-in-before but of size 95 sqmm 3.5 core, complete all as specified and as directed.
All as per item No 28 here-in-before but of size 70 sqmm 3.5 core, complete all as specified and as directed.
All as per item No 28 here-in-before but of size 25 sqmm 4 core, complete all as specified and as directed.
Excavation in trenches in any type of soil not exceeding 1.5 m wide and n.exe 1.5 m depth in foundation of pole/ laying of under ground cable and including getting out of any type of soft/loose soil, complete all as specified and as directed.
Returning filling in including spreading, leveling ,and well ramming, in layers not exceeding 25 cm each layer of any kind of soil, complete all as specified and as directed.
Removing surplus excavated material from site not exceeding 50 m from starting point and depositing where directed at level not exceeding 1.5 m above the starting point, complete all as specified and as directed.
Supply & laying Sand coarse dry as in cushioning of underground electric cable in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable) and gently punned down to 18cm thickness, complete all as specified and as directed. Note : Only punned down sand shall be measured.
M&L for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable, complete all as specified and as directed.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4 mpa working pressure, complete all as specified and as directed.
M&L for Hardcore of Broken Stone or Boulders of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface, complete all as specified and as directed.
M&L for PCC (1:3:6) type C2 using 40mm graded stone aggregate as in foundation for stay set /Pole/ FPB etc including fair finish even and fir to exposed surfaces without using extra cement, complete all as specified and as directed.
M&L for PCC (1:2:4) type B-1 (with using 20 mm graded stone aggregate) as coping of pole including necessary form work as required, complete all as specified and as directed.
Schedule of Credit
PURBANCHAL BUILDERS
BHARAT MULTITECH INDUSTRIES PVT LTD
Prasur Electricals & Engineering Co.
UNITED BUILDERS
KR POWER INFRA INDIA PVT LTD.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .