| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹10.5 L+₹11,190 (1.07%)Rejected-AOC | L2 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 3 | L3₹11.4 L+₹93,390 (8.95%)Rejected-AOC 397 JASPREET SALUJA INDORE VISHNUPURI ANNEX INDORE MADHYA PRADESH 452001 | INDORE | MADHYA PRADESH | 452001 | L3 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 4 | L4₹12.3 L+₹1.9 L (17.9%)Rejected-AOC 135 CHAKRANA TIWARI CHAKA NAINI PRAYAGRAJ 211008 UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211008 | L4 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 5 | L5₹12.5 L+₹2.0 L (19.5%)Rejected-AOC C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L5 | Rejected-AOC OTHER THAN LOWEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
7 May 2020, 6:00 pmClosed
GE of GE (SOUTH) AKHNOOR
GE (SOUTH) AKHNOOR C/O 56 APO PIN- 900234
PROVN OF DESERT COOLERS FOR BLDG NO P-39 (DINNING HALL) AND SPECIAL REPAIR FOR REPLACEMENT OF BER CEILING FANS AND STORAGE WATER HEATERS AT VARIOUS LOCATIONS UNDER GE (SOUTH) AKHNOOR.
2020_MES_338970_1
NIT-28
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (SOUTH) AKHNOOR
Class E and category b(i)
8 documents required · 8 mandatory
₹500
GE SOUTH AKHNOOR
₹30,000
Yes
29 Jul 2020
15 Apr 2020
9 May 2020
15 Apr 2020
7 May 2020
25 Apr 2020
Amount
SCHEDULE 'A' PART-I : BOQ OF WORKS FOR E/M WORKS.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc, complete all as specified and as directed by Engineer-In-Charge.
Point wiring (in existing concealed conduits to surfaces) for one light/ fan/ bell point controlled by one switch with 1.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, 1100 Volts, using colour coding, drawn in exisiting any type of conduit, of any dia including all accessories concealed in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint and with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 1.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge.
Switch piano, flush type, single pole, one way, 5 Amps, complete all as specified and as directed by Engineer-In-Charge.
Ceiling rose, three phase/ PVC/ polycarbonate, isolated body, complete all as specified and as directed by Engineer-In-Charge.
Taking down carefully existing ceiling fans, of any make and size from existing positions after disconnecting electric connections, including minors items, complete all as specified and as directed by Engineer-In-Charge.
Ceiling fan, mettalic, sweep 1400mm, high rating for energy saving, mettalic blades, copper wounded motor complete with hanging accessories i.e. U-clamp, down rod, canopy and nut bolts, washers, including fixing at site, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- FHCSSSTWHT56 (SS 390)/ Crompton Greaves/ Usha/ Orient.
Stepped type (multi-steps) electronic regulator for ceiling fan, 240 volts, 100 Watts, single pole, including connecting, complete all as specified and as directed by Engineer-In-Charge.
Hanging arrangement for ceiling fan, where ever required, made of mild steel hook, 15/ 16mm bore/ dia, 600mm long, hollow pipe as down rod, including flat iron clamps, nuts bolts and washers at upper end, complete all as specified and as directed by Engineer-In-Charge.
Taking down the existing geyser, of any capacity and any make/ design (Vertical or horizontal) by disconnecting the electric and water supply connections including cable connections, socket and plug top, complete all as specified and as directed by Engineer-In-Charge.
Non return valve, as per ISI specifications, suitable for geysers of 25/ 35/ 50 liters capacity, complete all as specified and directed by Engineer-In-Charge.
Water heater storage type (geyser), wall hanging, capacity 25 Litres, energy saving, having copper storage tank, high density PUF insulation, BEE high ratings, 230 Volts, single-phase, 50 Hz AC, rated power input not less than 1000Watt, complete all as specified. Make: Havells cat part No- Monza DX (GHWAMGSIB025)/ Bajaj cat part No-Calenta/ Jaquar cat part No- EPM-WHT-V025 (Elena Prime)
PVC connections steel wire spirally reinforced, 15mm size, 450mm long with brass union at both ends, for outlet water supply, complete all as specified and directed by Engineer-In-Charge.
PVC connections steel wire spirally reinforced, 15mm size, 600mm long with brass union at both ends, for outlet water supply, complete all as specified and directed by Engineer-In-Charge.
Point wiring (in existing concealed conduits to surfaces) for 3-pin, 15 Amps, switch socket combination on independent board with 2.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, FRLS, 1100 Volts, using colour coding, drawn in and including any type of conduit, any dia including all accessories concealed by chasing/ cutting in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 2.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge.
Plug and socket board, metal enclosure with 2-pole and earth, including MCB 20 Amps Single Pole and Neutral and all internal wiring with copper wire, making necessary connections, complete all as specified. Make: Havells cat part No- DHDPUSN020/DHDPUDP020 or equivalent in ABB/ Legrand/ L&T.
Earthing complete with galvanised iron earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected with 4.0mm dia GI wire as earth lead, by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 20mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15, type B-1 in pit with precast RCC M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates) in cover reinforced with XPM not less than 4.0 Kg per Sqm, test point etc. all as shown in electric plate No-3 of SSR Part-I (2009), complete with necessary earth work in any type of soil, removal to a distance not exceeding 50mtr, including testing on completion, complete all as specified and as directed by Engineer-In-Charge. Note: Earth pit chamber and RCC pit cover shall be painted with two coats of red synthetic enamel paint over one coat of primer including preparing of surfaces.
Switch socket combination 2-in-1, 3-pin, 5 and 15 Amp flush type universal type, complete all as specified and as directed by Engineer-In-Charge.
Tubes, 'medium grade' galvanised, 15mm bore, ISI marked with all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts, etc and fixed complete to walls and ceilings or laid in floors, complete all as specified and as directed by Engineer-In-Charge.
Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe for 15mm bore pipe, complete all as specified and as directed Engineer-In-Charge.
Mild steel in framed work such as grills, gratings, door frame etc; with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed stand for cooler mounting; walk ways; railings; wind ties, framework of water tanks and similar work conforming to Fe-290, Gde-E-165, complete all as specified and as directed by Engineer-In-Charge.
Desert cooler, electric driven copper wounded motor, single phase, 500mm metallic sweep cooler fan, 1400 rpm, 230 Volt, 50 Hz, air delivery capacity 4500 Cum/Hr, three speed regulator (high/medium/low) with metallic blade and mild steel body, duly painted with synthetic anti-corrosive oven cured paint, submersible pump 40 Watt (approx.), speed 1300 rpm, 230 Volts, 50 Hz and including wood wool pad of proper thickness and 2.50 Sqmm three core copper wire with connecting top plug, complete all as specified and as directed by Engineer-In-Charge. Make of motor: Khaitan/ Usha Lexus/ Orient/ Crompton.
Amount of Schedule of credit of for Rs 5,593.00 shall be deducted from quoted amount.
PACHNANDA BUILDERS
M/S ANMOL TRADING CO
VIJAY BUILDERS
MAMTA ENTERPRISES
M/S SAHNI CONSTRUCTION CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .