| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹6.7 LAdmitted-Finance | -21.50% | ₹6.7 L | L1 | Admitted-Finance |
| 2 | L2₹8.1 LAdmitted-Finance GANESH VIHAR KHASRA NO 178 MIN OLD 59 NEAR ANGAD BANQUET HALL CAMP ROAD JAMMU | JAMMU | JAMMU AND KASHMIR | 180001 | -5.67% | ₹8.1 L | L2 | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical JAMMU AND KASHMIR JAMMU AND KASHMIR | JAMMU | JAMMU AND KASHMIR | 181122 | - | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Updated dates
Tender Value
₹8.5 L
EMD Value
₹17,080
Closing Date
23 Mar 2026, 4:00 pmClosed
Er Pawan Tickoo
Executive Engineer PWD RandB Electric Div Jammu
please refer BOQ
2026_PWDJK_304054_1
Short e-NIT No.EDJ/196 of 2025-2026 Dated 20-02-2026
Open Tender
Electrical Works
30 days
Janipur Jammu
please refer to NIT
2 documents required · 2 mandatory
₹600
Executive Engineer PWD RandB Electric Div Jammu
₹17,080
7 Apr 2026
20 Feb 2026
24 Mar 2026
20 Feb 2026
23 Mar 2026
20 Feb 2026
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.
5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required
Supplying and fixing following rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole 6/10/16/32 Amp
Single pole and neutral 32 Amp
Triple pole and neutral 40 Amp
Triple pole and neutral 63 Amp
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutralb bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 way (4 + 18), Double door
8 way (4+24), Double door
12 way Double door
Supplying and fixing of 20/22 watt LED 4 feet tube light fitting/fixture aluminium housing with 2000 Lumens and min lumens efficiency 100 Lumens/watt P.F >0.9 THD < 16% with 50000 Burning hours
Fabrication, supplying, installation testing and commissioning of LT Panel CPRI approved made out of 2mm thick M.S. sheet, floor/wall mounted, vermin and dust proof, outdoor type with suitable size of angle iron legs for grouting in the ground if reqiuired with lockable type hinged doors, duly powder coated with provision of space for fixing of MCCB, C.O.S, MCB strips, aluminum Bus Bars, MCB strip etc.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
MCCB FP 800 Amp. 50 KA ICU=ICS=100%
MCCB FP 250 Amp. 36 KA ICU=ICS=100%
MCCB FP 200 Amp. 36 KA ICU=ICS=100%
MCCB FP 125 Amp. 36 KA ICU=ICS=100%
MCCB FP 100 Amp. 30 KA ICU=ICS=100%
MCCB FP 63 Amp. 25 KA ICU=ICS=100%
Aluminium Bus Bar 300 Amp of 4 strip Bus bar
Aluminium Bus Bar 400 Amp of 4 strip Bus bar
Supplying and fixing of following electrical items suitable for operating on 240/230Volts AC, 50 Hz supply. including connections etc. as required.
Ceiling fan 1200 mm sweep alongwith upto 1'-6" long fan rod. (BLDC)
Exhaust fan 300 mm size Metalic
400 mm sweep wall fan
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.55 MB
BOQ_987603.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid