Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 CrAccepted-AOC DOOR NO 19 FIRST FLOOR I BLOCK 1ST MAIN ROAD ANNA NAGAR EAST CHENNAI 600 102 | CHENNAI | TAMIL NADU | 600102 | ₹7.8 Cr | L1 | Accepted-AOC The lowest and negotiated tenderer |
| 2 | L2₹7.9 Cr+₹8.3 L (1.06%)Rejected-AOC | ₹7.9 Cr+₹8.3 L (1.06%) | L2 | Rejected-AOC The High rate tenderer |
| 3 | L3₹8.0 Cr+₹16.5 L (2.12%)Rejected-AOC | ₹8.0 Cr+₹16.5 L (2.12%) | L3 | Rejected-AOC The High rate tenderer |
| 4 | Rejected-Technical NO 22 27 3RD FLOOR AKILMEDU 7TH STREET BEHIND BUS TERMINAL ERODE 638 001 | ERODE | TAMIL NADU | 638001 | - | - | Rejected-Technical Disqualifed in the PQ evulation |
| 5 | Rejected-Technical | - | - | Rejected-Technical Disqualifed in the PQ evulation |
Tender Value
Refer Docs
EMD Value
₹4.8 L
Closing Date
25 Mar 2025, 6:00 pmClosed
Superintending Engineer/CC
No.132, E.V.R.Salai, Kilpauk, Chennai-10
Construction of New Working Women Hostel Building (192 beds G plus 4) Thozhi with development works at Sriperumbudur in Kancheepuram District
2025_TNPHC_532190_1
SE/CC/DB/539/2025
Open Tender
Civil Works
Lump-sum
330 days
Sriperumbudur in Kancheepuram District
Construction of New Working Women Hostel Building (192 beds G plus 4) Thozhi with development works at Sriperumbudur in Kancheepuram District
9 documents required · 9 mandatory
₹0
₹4.8 L
3 May 2025
13 Mar 2025
27 Mar 2025
13 Mar 2025
25 Mar 2025
13 Mar 2025
Amount
1.1) Earth work excavation in all soils (including refilling) a. 0 to 2 m.
1.5) Earth work excavation for Open foundation (excluding refilling) a. 0 to 2 m.
1.6) Earth work excavation for Open foundation for drains (excluding refilling) width upto 1.25 m a. 0 to 2 m
7.2)Supply and fixing of Bituminous filler pad, 20 mm tk. for expansion joint
13.1) Filling with Excavated Earth
21.2) Teak wood Wrought & Put up a. T.W. over 2 m & below 3 m
b. T.W. below 2 m length.
22.1) Supplying and fixing of Best Indian Teakwood Panelled door shutters Single leaf b. 1000X2100mm.with Aluminium furniture fittings (Single leaf)
23.3) Supplying and fixing of Magnetic door catches
30) Ellispattern
31) Weathering course
37.1) White washing 3 coats (slaked)
39) M.S Grills
40) Painting - New "wood work"
41) Painting - New "iron work"
46) Supply and fixing of 20 mm dia Alu. Hanger Rod
50.3) Supply and planting avenue trees
50.4) Providing Tree guard
52) Supplying, laying, fixing and jointing the following PVC pipes as per ASTM D - 1785 of schedule 40 a. 32mm dia ASTM D schedule 40 threaded PVC pipe with necessary PVC/GI specials
b) 25mm dia ASTM D schedule 40 threaded PVC pipe with necessary PVC/GI specials
52.1) G.I Pipe 20mm dia for Hot water line (Fully Concealed in walls)
Electrical arrangemnt 69) Supplying and fixing 15Amps 3 pin plug type socket on a suitable MS box 16g
72) Box type Fibre Fan hook
74) Charges for fixing of "Fan"
78) Providing Earthing station using pipe electrode as per IS 3043 using 2.5m of 40mm and 1.0 m of 20mm B-class GI pipe(Type I)
86) Anti termite treatment
Annexure 1.12) Supplying and filling with gravel
2.1.1) Filling C.S. sand
2.15) Supplying and filling stone dust
3.1.3) C.C.1:5:10 for Foundation & Basement
3.2.3) P.C.C. 1:2:4 for Foundation & Basement and other similar works
3.3.3) P.C.C. 1:8:16 using 20 mm broken brick jelly
3.8.3) P.C.C. 1:4:8 using 40 mm broken brick jelly
6.2.3) Brick work in CM 1:5 (One of cement and five of crushed stone sand) using Flyash bricks of size of 9”x4¼”x2¾” (23x11x7cm) in foundation and basement
8.2.3.1) Standardised concrete Mix M30 Grade Concrete a. In Foundation and basement
b. In Ground / Stilt Floor
c. In First Floor
d. In Second Floor
e. In Third floor
f.In fourth floor
g. In Fifth Floor
9.2.3) Brick work in Cement Mortar 1:6 (One of cement and six of crushed stone sand,) using Flyash bricks of size 9”x4¼”x2¾” (23x11x7cm) for super structure in the following floors (a) In Ground Floor
b. In First Floor
c. In Second Floor
d. In Third Floor
e. In Fourth Floor
f. In Fifth Floor
10.2.3) Brick partition wall in Cement Mortar 1:4 (One of cement and four of crushed stone sand,) 110mm thick for super structure in the following floors using Flyash bricks of size 9”x4¼”x2¾” (23x11x7cm) a. In Foundation and Basement
b. In Stilt / Ground Floor
c. In First Floor
d. In Second Floor
e. In Third Floor
f. In Fourth Floor
18.1) Formwork using M.S.Sheet a.For Column footings, plinth beam, Grade beam, Raft beam, Raft slab etc.,
b.Plain surfaces such as Roof slab, floorslab, Beams, lintels, lofts,sill slab,staircase,portico slab and other similar works
c.For Square and rectangular columns and small quantities
d.Vertical wall
21.5.2.2) Supply and Fixing Soild UPVC door Shutter with frame
21.7.3) Supplying and fixing of Solid Core Flush door Shutters with teakply on both side with teakwood lipping alround 35mm thick a) 1000x2100mm (single leaf)
26.1) Flooring in C.C.1:5:10
28.1) Floor plastering in C.M. 1:4, 20 mm tk.
29.8.1) Glazed tiles using Grout (Tile Joint Filler), C.M 1:2, 10mm tk
29.9.1) Floor ceramic tiles (Anti-skid) using Grout (Tile Joint Filler).
32.1.1) Pressed tiles (23cmx23cmx20mm) mixed with Water proofing compound
33.2.1) Plastering with CM 1:5 12mm thick finishd with neat cement
34.2.1) ) Plastering in C.M. 1:4, 12 mm tk.
35.2.1) Spl. Ceiling plastering in C.M. 1:3, 10 mm tk.
36.1) Cement mortar Border in C.M. 1:5, 12 mm tk. a. 75 mm wide
c. 50 mm wide
43.2.1) Fabrication of Mild steel / RTS grills (without cement slurry) for all sizes of rods.(BINDING WIRE insulated with PVC)
44.2.1) Rain water harvesting using defunct borewell and providing perforated cover slab a). Providing pit (M30)
b) Augering 30cm dia
44.6) Supplying and fixing of 110mm dia PVC SWR pipe with ISI mark confirming to IS 13952:1992- type 'A' for Rain water down fall pipe
50.2.1) Providing precast Kerb stone in C.C. 1:3:6, 450 x 300 x 150 mm
50.5.1) Supplying. Fabricating and erection of M.S Scheme Name board
50.6.1) Supplying and fixng of Fibre mixed precast slab of 50mm thick of all required shapes made in cement concrete 1:3:6
52.4) 20mm dia PVC water supply ASTM pipe (fully consealed in walls)
53.5) Wash Hand Basin of size 550 x 400 mm (White without Pedestal)
54.1.1) Supplying and fixing of of 15mm dia half turn CP long body tap
54.2.1) Supplying and fixing of of 15mm dia half turn CP short body tap
56.4.1) Supplying & fixing of Indian Water closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR grade ' P' or "S' trap- Other than G.F.
57.1.2) Supplying and fixing of of E.W.C.(White) 500 mm with "P" or "S" TRAP with double flapped seat & seat cover
58.3) PVC SWR pipe (Soil line) with ISI mark - type 'B'. a. 110 mm dia.
b. 75 mm dia.
58.4) Supplying, Laying & Concealing the 50mm dia PVC ( SWR) pipe with ISI mark type - 'B' with relevant specials.
60.1) PVC Nahani trap (4way/2way)
61.3) UPVC Non Pressure pipe of SN8 SDR 34 ( S 16.5) as per IS 15328/2003 a. 110 mm UPVC Non Pressure pipe
b. 160 mm UPVC Non Pressure pipe
64.1) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990. a. Light point with ceiling rose
b. Light point without ceiling rose
c. Calling bell point with Buzzer/Calling bell
64.1.1) Wiring with 1.5 sqmm copper PVC insulated unsheathed single core 1.1 K.V. grade cable 5 amps flush type switch [Open Wiring] a) Light point With Ceiling Rose
64.3.2) Wiring for lift well light point and socket outlet with 2 x 1.5 sqmm FRLS PVC insulated stranded copper conductor of 1100V
65.1) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Fan point
66.1) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Staircase Light Point.
67.1) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Switch Board Itself
68.2) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Convenient Places
70.5.2) Supply and fixing of 4' long 18 W Crystal Glass LED tube Light with fitting
75.2) Supply and delivery of 48" (1200 mm) Fan with ISI mark with Eletronic Dimmer
77.5.1) Run of main with 2 wires of 1.5 sq.mm. PVC insulated single core multi strand fire retardant flexible copper cable(Open wiring)
77.7) Run of 2 Wires of 2.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
77.8.1) Run of main with 2 wires of 6 sq.mm. PVC insulated single core multi strand fire retardant flexible copper cablewith ISI mark conforming to IS: 694/1990 (Open Wiring)
82.3.1)Supply and fixing of LED Street lighting luminaries suitable for fixing following watts LED lamp a) 25W LED Street Light Fitting with LED (Lower End)
b) 48W LED Focus Light Fitting with LED (Higher End)
84.3) Run of 2 Wires of 4 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
88.3) Providing Rajasthan kota stone flooring, C.M 1:3, 20mm tk
90.2.1) Providing additional Strutting to centering of R.C.C slab and beams of all surfaces or any other form works required at site during execution of work for every additional 1 metre height a) 3.31mt. to 4.3mt
93.1) Plastering with CM 1:3, 12mm with WPC
96.7) Supply and Laying Rubber Moulded Hyraulic Pressed Paver Block 83 mm thick including labour charges for laying etc
98.5.1)TW panelled Double leaves door shutter with Brass furniture fittings. a.1800X2400mm. (Double leaves)
112.1) S & F of Exsaust Fan 225 mm dia
149.3.4) Supply and fixing of 65mm dia GI pipe (Class 'B') of 4 metre length with 300mm x 300mm x 6mm MS base plate
175.3.1) Supply and fixing of 7 segment 6 way TPN MCB sheet steel distribution board (Higher end) with metal / acrylic door cover flush type /surface type fitted with busbars and neutral links with single / three phase MCB .
207.3.1) Providing two coats of Plastic Emulsion paint including primer for inner walls
207.4.1) Providing two coats of Exterior Emulsion paint including primer for outer walls
213.1) Supplying and fixing of SRFC cover slab a.60cm x 60cm
216.3) Suppling and fixing of MS pipes IS sepcification with required steel section used for fabrication of truss works
254.1)Two legged scaffolding using 15cm dia casurna props For 3m Height
255.2) Supplying and fixing of LED Bulb for suitable for fixing it to pendent / bakelite battern holder a) 9watts LED bulb
b) 12 watts LED bulb
255.6) Supply and fixing of Bulk Head fitting suitable for 12W LED Bulb
343.2.2) Supply and fixing of Galvanium sheet 0.47mm thick
344.2) Supply and fixing of Bevelled edge mirror 500 x 400 x 5.5mm
362.2.2) Suppling and laying of Stain Free Nano Polish Vitrified Tiles 600 x 600 x 8mm Flooring in C.M 1:3
366.3.1) Manufacturing, Supplying and Fixing of Stainless Steel Hand rails from finished floor level
379.6.1) Supply and Laying of Granite tile of 10mm thk (wall Cladding ) in C.M 1:2 (Ruby Red)
379.8.5) Supply and Laying of Granite slab Flooring in C.M 1:3 20mm Thick incl. pointing (Sinthetic Grey, Paradise and similar varieties)
451.3) Supplying and fixing of best approved quality Brass chromium plated soap tray of size 150mm x 100mm
451.3.3) Supplying and fixing of best approved quality of following Stainless steel water supply/Sanitary fittings a) Stainless steel Health faucet
532.2) Supplying and applying of Wall putty one coat with approved make wall putty for smooth finishing the new cement plastered walls
532.3) Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling
540.1.3) Supply and fixing of MS stand for fixing outdoor unit
540.1.6.1) Supply & Installtion of 5 star rated Air- Conditioner with copper coil b) 2.0 TR Split Type AC Unit - 5 Star Rated
540.1.8.1) Supply, delivery and laying of PVC drain pipe 25mm dia with specials (For AC)
540.1.9.1) Supply and installation of 5 KVA capacity Automatic Voltage Stabilizer with time delay relay
540.2.1) Supply and laying of 5/8" and 3/8" copper pipe (Extra beyond 3 m supplied with AC unit)
778.2.3) Supplying, fabricating, erecting and fixing Hilux (Equivalent Board False Ceiling upto a ceiling height of 4.5m from floor level Using Hilux Board Plain Sheets (10mm thick)
832.5.2)Supplying and fixing in position of UPVC window of casement type( open) for all sizes
832.5.3)Supplying and fixing in position of UPVC Ventilator louvered ventilator type for all sizes
958.3)Design, Manufacture, supply, delivery, installation, testing and commissioning of Passenger Lift of capacity 13 persons / 884 Kg as MRL, Speed 1.5 m/s
959.2) Erection, Testing and commissioning of 100KVA Diesel generator set. With AMF Panel
960.1.1) Supplying delivery and fixing of PA mixer Amplifier 120 watts
960.1.2) Supplying delivery and fixingof 15 watts Speaker wall mounting
960.1.3) Supplying delivery and fixing fixing of Cordless Mic UHF
960.1.4) Supplying delivery and fixing of Chairman unit
960.1.5) Supplying delivery and fixing of Conference controller
960.1.6) Supplying delivery and fixing of 8 Pin Conference Mic Socket with Modular Box and Front Plate
960.1.7) Supplying delivery and fixing of 2 Core 1.5 sq.mm Shielded Copper Speaker Wire
960.1.8) Supplying delivery and fixing 10’ x 8’ Motorized Screen
960.1.9) Supplying delivery and fixing 20 Metre HDMI Cable
N SAKTHIVEL AND CO (BID ID -1277797)
chendur construction company (BID ID -1276086)
Bidder Name
Unic Associates
chendur construction company
N SAKTHIVEL AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .