Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹62.3 LAccepted-AOC | ₹62.3 L | L1 | Accepted-AOC Awarded being 1st Lowest Bidder |
| 2 | L2₹75.0 L+₹12.7 L (20.4%)Rejected-Finance | ₹75.0 L+₹12.7 L (20.4%) | L2 | Rejected-Finance Rejected being 2nd Lowest Bidder |
Tender Value
₹75.7 L
EMD Value
₹1.4 L
Closing Date
1 Jul 2020, 6:00 pmClosed
COMMANDER WORKS ENGINEER, SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
CA NO. CWE SGNR-72 OF 2019-20 SPECIAL REPAIRS TO B/R AND E/M WORKS IN OTM ACCOMMODATION COOK HOUSE IN BUILDING NO. P-76/01 TO P-76/03 AND P-77/01 TO P-77/02 AT MILITARY STATION FAZILKA
2020_MES_325790_1
CA NO. CWE SGNR - 72 OF 2019-20
Open Tender
Civil Works
Item Rate
180 days
ABOHAR
Class C
Category a(i)
10 documents required · 10 mandatory
₹1,000
GE ABOHAR
₹1.4 L
Yes
10 Jul 2020
27 May 2020
3 Jul 2020
27 May 2020
1 Jul 2020
17 Jun 2020
Amount
Taking down chowkats or frames with shutters (with out taking off shutters from the frame) not exceeding 1.50 Sqm each complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhats or frames with shutters without taking off shutters from the frame exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified and directed by Engineer-in-Charge.
Taking down shutters and removing to store but area exceeding 1.00 Sqm and not exceeding 2.0 Sqm complete all as specified and directed by Engineer-in-Charge.
Taking down shutters and removing to store but area not exceeding1.0 Sqm complete all as specified and directed by Engineer-in-Charge.
S&F in repairs, steel window 1.25mm thick box type (primer coated) ERW hollow 'P' section of size 60mm x 25mm single rebated comprises guard skeleton shutter ERW section 50mm x 20mm and 1m thick with two openable leaf consisting two Nos. of sash bars of flat iron 12mm x 3mm complete welded to frame with one vertical mullion of ERW box type 'T' section of size 60mm x 25mm and 1.25mm thick including cutting holes and making good dismantled portion in PCC (1:2:4) type B1 four Nos. for each window including following fittings welded to thr frame complete all as specified and directed by Engineer-in-Charge. (a) Hold fast 150mm long of 12mm x 3mm made to shape - 04 Nos. Per Window (b) Handle of 'Z' section 20mm x 25mm, 100 long - 01 No. Per Leaf (c) MS tower bolt 150mm long - 02 Nos. Per Leaf (d) MS pintol hinges of size 100 x 14mm - 02 Nos. Per Leaf (e) 'Z' section 20mm x 25 mm x 100mm long stopper Per leaf Make : M/s Tee Pee Enterprises, M/s Friends Manufacturing Co., Kotkapura, M/s AGEW Steel Mfg Pvt Ltd, Ahmedabad, Ashwini And sons, Ghaziabad, M/s Godrej & Boyce Steel Mfg, Mumbai or equivalent as approved by GE Note : Wire Mesh and painting shall be measured and paid separately under appropriate item of BOQ
S&F in repairs, steel window 1.25mm thick box type (primer coated) ERW hollow 'P' section of size 60mm x 25mm single rebated comprises glazed skeleton shutter ERW Section 50mm x 20mm and 1m thick with two openable leaf consisting two Nos. of sash bars of flat iron 12mm x 3mm complete welded to frame with one vertical mullion of ERW box type 'T' section of size 60mm x 25mm and 1.25mm thick including cutting holes and making good dismantled portionin PCC (1:2:4) type B1 four Nos. for each window including follwing fittings welded to the frame shutter complete all as specified and directed by Engineer-in-Charge. (a) Hold fast 150mm long of 12mm x 3mm made to shape - 04 Nos. Per Window (b) Handle of 'Z' section 20mm x 25mm, 100mm long - 01 No. Per Leaf (c) MS Tower bolt 150mm long - 02 Nos. per Leaf (d) MS pintol hinges of size 100mm x 14mm - 02 Nos. Per Leaf (e) 'Z' section 20mm x 25mm x 100mm long stopper Per Leaf Make : M/s Tee Pee Enterprises, M/s Friends Manufacturing Co., Kotkapura, M/s AGEW Steel Mfg Pvt Ltd, Ahmedabad, Ashwini And sons, Ghaziabad, M/s Godrej & Boyce Steel Mfg, Mumbai or equivalent as approved by GE Note : Glass and painting shall be measured and paid separately under appropriate item of BoQ
Supply and fixing in repairs drapery curtain rod 25mm dia, fancy type, fabricated out of mild steel sheet not less than 20 guage, including brackets and pair of decorated end knobs (finials), stop roller etc, pretreated powder coated natural color complete all as specified and directed by Engineer-in-Charge.
S & F for Solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M S square tubes , S&F in opening as per specification & drawing given in SSR-2009 complete all as specified and directed by Engineer-in-Charge.
S&F for Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M S tubes for top & bottom rails M S frame shall be covered with heat moulded plain colour PVC ‘c’ channel having a PVC sheet strip of 20 mm width struck in side with solvent cement for stiles and plain colour PVC sheets 5 mm thick for top rail, lock rail & bottom rail on either side & as gap insert for tap rail & bottom rail, paneling of plain colour PVC sheets to be fitted in the MS frame walded/sealed to the stiles & rails with suitable PVC sheet beading and joined to getger with solvent cement supplying & filling in the frame at site as per specification & drawing given in SSR-2009 complete all as specified and directed by Engineer-in-Charge.
S & F in repairs aluminium handle cast type anodized 150 mm long complete all as specified and directed by Engineer-in-Charge.
S & F in repairs aluminium anodized barrel tower bolt of extended section and fixed 200 mm long complete all as specified and directed by Engineer-in-Charge.
S & F in repairs 100 mm long butt hinges extruded aluminium alloy with galvanised mild steel hinges pin,anodised and fixed complete all as specified and directed by Engineer-in-Charge.
S & F for pressed steel door frames with one or more rebates including necessary fixing lugs hinges lock strike plate etc complete all as specified size of frame 125X60mm complete all as specified and directed by Engineer-in-Charge.
S & F for pressed steel door frames with one or more rebates including necessary fixing lugs hinges lock strike plate etc complete all as specified size of frame 105X60mm complete all as specified and directed by Engineer-in-Charge.
M&L for Cement concrete 1:2:4 type B-1 for filling of pressed steel fram and hold fast blocks etc complete all as specified and directed by Engineer-in-Charge.
M&L for Cuting hole in brick wall in cement mortar for inserting hold fast and making good dismantled portion in CM 1:3 or cement concrete 1:2:4 type B1 as required exc half brick but n.exc one brick complete all as specified and directed by Engineer-in-Charge.
S & F for Flush shutters,35mm thick,solid core construction,with block board core and plywood face panels,commercial type on both sides as specified in SSR Part – I, Section – 8, clause 8.20 (a) ; supplied and fitted to chowkats complete all as specified and directed by Engineer-in-Charge.
M & L for block boards 19 / 20mm thick, grade 2 quality, interior grade, decorative type with decorative face veneer on one face, fixed with screws to timber as in pelmet/shelves frame work with teakwood lipping 6 mm thick complete all as specified and directed by Engineer-in-Charge.
S & F in repairs continous piano hinges mild steel bright finish or galvanised of 30mm width complete all as specified and directed by Engineer-in-Charge.
S&F for second class hard wood plain solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 125mm Hasp and staple, aluminium anodized, including bolt to hinge plate and fixed with screws complete all as specified and directed by Engineer-in-Charge.
S&F factory made 35mm thick 2nd class hard wood glazed and skeleton shutter, open rebated and prepared to receive glass, gauze etc. (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred breads for securing glass etc. size of members of shutters as specified in SSR Part-I, Section 8, Clause 8.20(a), supplied and fitted to chowkhats complete all as specified and directed by Engineer-in-Charge.
S & F for Aluminium alloy, anodised, sliding door bolt 300mm with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed by Engineer-in-Charge.
M&L for two coats of synthetic enamel on wood (ordinary tint) over one coat of pink primer over 10cm width or girth incl preparation of surface complete all as specified and directed by Engineer-in-Charge.
M&L for two coats of synthetic enamel paint on steel Surfaces over one coat of priming with red oxide or zinc chromate of any descri-ption, over 10cm in width or girth , not other wise described, including preparation of new surface complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of old painted wooden surfaces of any description over 10 cm width of girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of old painted steel surfaces of any description over 10 cm width of girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster/dado on brick wall including racking out joints, hacking for keys scrubbing down with water complete all as specified and directed by Engineer-in-Charge.
M & L for rendering 15mm thick on fair faces of brick work in CM 1:6 finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M & L for rendering 15mm thick on fair faces of brick work in CM 1:4 finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M & L for 10mm thick rendering in Cement Mortar 1:3 to ceiling surfaces finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for Rough cast plaster complete all as specified and directed by Engineer-in-Charge. Note : Rendering coat not less than 10mm thick in C:M 1:3 , while it is still in plastic state the rough cast mixture consisting of crushed stone or fine gravel agg size 6 to 12mm mixed with coarse sand and cement in the ratio of 1:1:1 shall be applied and finished eaven
Dismentling floor, hearth or wall tiling including cement mortar bedding (but not backing), remving serviceable tiles to stores and and rubbish off the permises complete all as specified and directed by Engineer-in-Charge.
M&L for glazed ceramic tiles (200 x 300) mm x 7 mm colour tiles on walls etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the work over 10 mm rendering in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L for glazed ceramic coloured tiles, (300x450)x7-8mm thick as in vertical surfaces like dado or skirting over 10mm thick in CM 1:4 set & joined in neat cement slurry and pointed in coloured cement to match complete all as specified and directed by Engineer-in-Charge.
M&L for Non skid ceramic tile 7-8mm thick area of each tile exc 0.18 Sqm but not exc 0.36 sqm in floor set and jointed in neat cement surrey and point in white cement to match colored tile over 15mm screed in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L for 400x400x7mm non-skid coloured ceramic tile in floor set & jointed in cement slurry over 15mm thick cement screed 1:6 set & joined in neat cement slurry and pointed in coloured cement to match complete all as specified and directed by Engineer-in-Charge.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and directed by Engineer-in-Charge.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons Laid, bedded and pointed in any mortar etc. complete all as specified and directed by Engineer-in-Charge.
M&L for marble work 18mm to 20mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar 1:3 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with marble shade complete all as specified and directed by Engineer-in-Charge.
M&L for polishing old kota stone slab flooring 18-20mm thick complete all as specified and directed by Engineer-in-Charge.
M&L for machine cut kota stone slab flooring 18-20mm thick over cement screed base laid and jointed with grey cement mixed with pgment to match the shade of the slab including rubbing and polishing complete inculding screed bed or bedding layer of mortar 15 mm thick CM (1:6) complete all as specified and directed by Engineer-in-Charge.
M&L for kota stone slab flooring 18-20mm thick in riser of steps,skirting,dado and pillar laid and jointed with grey cement mixed with pgment to match the shade of the slab including rubbing and polishing complete inculding screed bed or bedding layer of mortar 15 mm thick CM (1:6) complete all as specified and directed by Engineer-in-Charge.
M&L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 20mm PTMT , high pressure, with polytheene float and flynut complete, screwed for iron pipe orr brass ferrule complete all as specified and directed by Engineer-in-Charge.
S&F in repairs, for rotational moulded polythylene water storage tank 2000 ltr capacity (Cylinderical vertical with closed top) hoisted and fixed in position complete all as specified and directed by Engineer-in-Charge.
S&F in repairs, for rotational moulded polythylene water storage tank 500 ltr capacity (Cylinderical vertical with closed top) hoisted and fixed in position complete all as specified and directed by Engineer-in-Charge.
M&L for 50mm thick PCC type C-1, (1:3:6) using 20mm graded stone aggregate Finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Continuous brick edging; with burnt clay Old size bricks of sub class B with width equal to the depth of the brick, laid dry, on end vertically complete all as specified and directed by Engineer-in-Charge.
Cleaning and fixing rotational moulded polythylene water storage tank 2000 ltr capacity (Cylinderical vertical with closed top) hoisted and fixed in position complete all as specified and directed by Engineer-in-Charge.
S & F in repair galvanised mild steel wire cloth , 0.56 mm nominal dia of wie and average width of aperture 1.18mm, complete all as specified and directed by Engineer-in-Charge.
S & F in repairs galvanised mild steel wire cloth, 0.51 mm to 0.56 mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks, or galvanised wire staples, complete all as specified and directed by Engineer-in-Charge.
M & L for Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed by Engineer-in-Charge.
S&F for Sheet glass 3.0mm thick, ordinary quality & glazing with oil putty in square n exc 0.5 sq.m in each pane complete all as specified and directed by Engineer-in-Charge.
S&F for 4.8mm thick sheet glass ordinary quality and glazing with oil putty in square n. exc. 0.5sq.m in each pane complete all as specified and directed by Engineer-in-Charge.
S&F for Anodised aluminium frame for doors, windows , ventilator with one or more rebates incl necessary joining cleats for fixing etc complete all as specified and directed by Engineer-in-Charge.
S&F for Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed by Engineer-in-Charge.
S&F in repair bib taps 15mm bore dia, fancy type, cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed complete all as specified and directed by Engineer-in-Charge.
S&F in repair Stop cock 15mm bore dia, fancy type, cast copper alloy screwed down ,high pressure,with crutch or butterfly handle, screwed down, screwed both ends to iron pipe of size 15mm complete all as specified and directed by Engineer-in-Charge.
S&F for angle valves chrome plated fancy type 15 mm bore, cast copper alloy screwed down high presure, with crutch of butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed by Engineer-in-Charge.
S & F in repair MS 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed by Engineer-in-Charge.
S&F in repair brass chromium plated towel rail of size 60cm fixed with chromium plated brass screws and plastic cleats complete all as specified and directed by Engineer-in-Charge.
S & F in repairs for brass chromium plated shower rose 125 mm size with swivel joint including fixing to 15 mm dia steel pipe or union complete all as specified and directed by Engineer-in-Charge.
Supply & fixing for PVC connection in repair both sides brass unions internal for size of 15mm size with PTMT nuts of length 450mm long complete all as specified and directed by Engineer-in-Charge.
S & F for PVC waste pipe 32mm dia & 90 cm long complete all as specified and directed by Engineer-in-Charge.
M&L for Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc. complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered or unplastered surface of walls and applying two coats of cement based paint complete all as specified and directed by Engineer-in-Charge.
M&L for complete removal of existing treatment from old plastered surfaces of wall and applying two coats of cement based paint complete including preparation of surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for complete removal of existing treatment and applying one coat of exterior weatherproof emulsion paint on walls over a coat of exterior wall primer after prepration of surface (work will be executed in officers Qtrs) complete all as specified and directed by Engineer-in-Charge.
M & L for Preparation of newly plastered surfaces by applying two coats of interior grade wall putty and making it smooth with sand paper by mechanical method i.e. with hand electric grinder then applying two coats of oil bound distemper over one coat of cement primer including all as specified by mechanical method i.e. spray gun complete all as specified and directed by Engineer-in-Charge.
M & L for Preparation of Old plastered surfaces by removing old treatment and applying two coats of interior grade wall putty and making it smooth with sand paper by mechanical method i.e. with hand electric grinder then applying two coats of oil bound distemper over one coat of cement primer including all as specified by mechanical method i.e. spray gun complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered or unplastered surface of ceiling and applying three coats of white wash complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old decorated, plastered or pointed surfaces of ceiling and applying one coat of white wash complete all as specified and directed by Engineer-in-Charge.
Providing and applying rising damp proof coating system with single component ready to use damp proof coating Roff Hydamp complete all as specified and directed by Engineer-in-Charge.. 1.SURFACE PREPARATION - Throughly brush and clean all laitance ,loose particles, efflorescence,bird droppings etc all large voids or hollow portion must be removed.Non moving cracks having width up to 5mm most be filled with polymer based crack fillar. 2.APPLICATION :- Apply the first coat of Roff Hydamp with a paintbrush directly on the prepared surfaces.Allow to dry for a minimum 2-3 hrs.Apply one part of Roff Hydamp and 2 part of OPC white cement and make the putty.apply putty on the entire surfaces area.Allow to dry for atleast 3-4 hours.Apply the final coat of Roff Hydamp on the entire surfaces.
M & L for one coat of white wash on old decorated plastered or unplastered surfaces of walls including preparation of surfaces complete all as specified and directed by Engineer-in-Charge.
M & L for three coat of white wash on old decorated plastered or unplastered surfaces of walls including preparation of surfaces complete all as specified and directed by Engineer-in-Charge.
Dismantling of CI pipes or reinforced concrete pipes 100 mm dia fixed to wall etc complete all as specified and directed by Engineer-in-Charge.
Dismantling of CI pipes or reinforced concrete pipes 75 mm dia fixed to wall etc complete all as specified and directed by Engineer-in-Charge.
S & F for 100mm cast iron sanitary connection socket to fit WC out-let complete all as specified and directed by Engineer-in-Charge.
S&F for 100mm CI Bends (any radius), diminishing pieces or tapers (larger bore measured) fitted with oval access door complete all as specified and directed by Engineer-in-Charge.
S&F for 75mm CI Bends (any radius), diminishing pieces or tapers (larger bore measured) fitted with oval access door complete all as specified and directed by Engineer-in-Charge.
S&F for 100mm CI Bends (any radius) with duck’s foot or heel rest fitted with oval access door complete all as specified and directed by Engineer-in-Charge.
S&F for 100mm CI Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed by Engineer-in-Charge.
S & F in repairs 75mm bore Cast iron cowls, complete all as specified and directed by Engineer-in-Charge.
Taking down steel tubing 15mm bore and connections,including cleaning for refixing or remove to store complete all as specified and directed by Engineer-in-Charge.
Taking down steel tubing 20mm bore and connections,including cleaning for refixing or remove to store complete all as specified and directed by Engineer-in-Charge.
S & F 15mm bore medium grade tube galvanised with all fittings and fixed complete concealed including groove cutting for concealing to walls & ceiling or laid in floor complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 87 here-in-before, but for fixing only complete all as specified and directed by Engineer-in-Charge.
S & F for 20mm bore medium grade tube galvanised with all fittings and fixed complete concealed including groove cutting for concealing to walls & ceiling or laid in floor complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 89 here-in-before but for fixing only complete all as specified and directed by Engineer-in-Charge
S&F for cast iron 100 mm dia floor trap, plain with grating including jointing with solvent cement to connect waste pipe and fixed with PCC 1:2:4 complete all as specified and directed by Engineer-in-Charge
S&F for 75mm sand cast Cast iron soil, waste and vent pipes, in any length with or without ears, with cement joints, fixed to walls complete all as specified and directed by Engineer-in-Charge
S&F for Cast iron soil 100 mm bore , waste and vent pipes, in any length with or without ears with cement joints, laid in walls or in floors complete all as specified and directed by Engineer-in-Charge
Dismantling of brick work built in cement motor complete all as specified and directed by Engineer-in-Charge
M&L for Brick work with old size burnt fly ash bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 complete all as specified and directed by Engineer-in-Charge
M & L for mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking, hooking ends and binding with MS wire (annealed) not less than 0.90mm dia complete all as specified and directed by Engineer-in-Charge
M & L for form work to soffits of suspended slabs such as roof slab and similar work not exceeding 200mm thick for rough finished surfaces of concrete complete all as specified and directed by Engineer-in-Charge
M & L for form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide for rough finished surfaces of concrete complete all as specified and directed by Engineer-in-Charge
Demolition of Reinforced cement concrete (reinforcement cut as required to facilitate demolition) in floors / pavings, (below or above ground level) and of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer-in-Charge
S & F for Waste coupling for 40mm dia of discharge pipe of PTMT (half or full threaded). (Minimum weight 45gms) complete all as specified and directed by Engineer-in-Charge
Taking down shutters and Refixing of shutters of any description exceeding 1.00 Sqm and n. exc.2.00 sqm each in the same opening complete all as specified and directed by Engineer-in-Charge
Taking down eves and gutter and rainwater pipe complete all as specified and directed by Engineer-in-Charge
S & F for PVC pipes (SWR) single socketed with rubber ring joints 110mm dia fixed to wall complete all as specified and directed by Engineer-in-Charge
S&F for PVC ( SWR) bends any radius bore of 110 mm complete all as specified and directed by Engineer-in-Charge
M&L for PCC (1:5:10) type E-2 (using 40mm graded brick aggregate) as in foundation, filling & mass concrete or filling in sunken floor complete all as specified and directed by Engineer-in-Charge
M&L for Water proofing treatment to RCC sunken slab (not exceeding 45cm depth of sunken) as specified below and as directed by Engineer-in-Charge. :- (a) applying 15 mm plaster in CM 1:3 with WPC on raised verticle surface (b) Cleaning the surface with wire brush/coir brush, removing lose material like dust particles, dirt etc. (c) Creating fillet coving of 50x50 mm with polymer modified mortar on the junction of slab and walls (d) Apply first coat of two component modified polymer coating on the horizontal and verticle surface (e) Provision of glass fiber mesh of 2 x 2 mm immediately on above coating (f) Apply second coat of two component modified polymer coating after 72 hrs (g) Cement concrete 1:4:8 over the coating as per requirment (h) Joining the saintary pipes with the water proofing tape having bridging ability of more than 1.5 mm (j) Filling the gap between the wall opening and saintary pipe with non shrink cementatious grout complete all as specified and directed by Engineer-in-Charge Make:- Dr. Fixit/Fosroc/STP Note: (i) The treatment shall be carried out by approved authorised applicator approved by CWE as per the manufacturers instructions and as directed by the Engineer in charge. (ii) The Plan area of floor (sunken) shall be considered for payment and provn of cement work except PCC in sunken filling item 91 is included in quoted rate for this item. (iii) PCC filling in sunken portion will be measured seperately.
Supply and fix in repair PVC low level flushing cistern 10 litre capacity, valveless syphonic action type with float, handle including flush pipe of polythene of low or high density of PVC 32mm dia, 60cm long and bracket etc and making connection including making good disturbed portion complete all as specified and directed by Engineer-in-Charge
S&F in repair vitreous china squatting pan "ORISSA" pattern size 580mmx440kmm, white with integral foot rest including cast iron 'P' or 'S' trap and connection to trap includintg cement concrete, and to flushing pipe, anti-syphonage pipe, etc. including making good to floor, complete all as specified and directed by Engineer-in-Charge
S&F in repairs Vitreous China wash down water closet pan (Pedestal pattern) white excluding fixing bolt incl plastic water closet seat cover and mild steel chromium plated or aluminised hinging device and jet spray complete all as specified and directed by Engineer-in-Charge
M&L for Shotcreting 25MM thick in RCC columns, beams and slabs etc in layers with approved design mix (minimum cement content of 350 Kg/Cum on M-25) concrete having the specified minimum characterristic compressive strength (with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria) including the cost of certering and shuttering at edges and corners etc as directed by Engineer-in-Charge including Chipping of unsound /weak concrete material 50mm average thickness from slabs,beams, columns etc with manual chisel and /or by standred power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes and thoroughly washing with water and allowing it to dry etc. including removal of rust by applying approved rust removal chemical & the coating with Dr Fixit epoxy zinc primer@ 6sqm/ltr at DFT of 100microns as per specifications and disposal of debries for all lead and lifts complete all as specified and directed by Engineer-in-Charge
S&F for hard drawn steel wire fabric not exceeding 4 Kg / Sqm cut to lengths, bent to shape required and tying with mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcement complete all as specified and directed by Engineer-in-Chage.
Supply only liquid water proofing compound complete all as specified and directed by Engineer-in-Charge
Removal of mud to a distance exceeding 50m and n exc. 250m and depositing where complete all as specified and directed by Engineer-in-Charge
M & L for 15mm thick waterproof plaster using cement sand mortar 1:3 on slab/existing roof surfaces & vertical surface admixed with Dr Fixit Pidiproof LW+ @ 200ml per bag of cement complete all as specified and directed by Engineer-in-Charge
M & L for 25mm thick plain cement concrete (1:2:4) type B-0 using 12.5mm graded stone aggregate on roof slab complete all as specified and directed by Engineer-in-Charge.
Providing and applying microfiber reinforced UV resistant Acrylic polymer coating three coats having solid contents 69% polymer content 35% & Tensile strength 2.6N/mm2 of Dr. fixit Newcoat/stat/parex or equivalent with a paint brush over existing roof surface after removal of all loose material, lime dust etc. with wire brushes, coir brushes from roof surface to get absolutely cleaned surface free of foreign contaimnant filling of cracks wherever found with polymer based mortar, and after repairing the surface apply primer coat with Dr. fixit Primeseal. polyester reinforced fiber net laid on the surface after the first coat and all the joints of brick is repaired by polymer based mortar. Undulation on the surface repair before executing the water proofing treatment complete all as specified and directed by Engineer-in-Charge Note : The treatment shall be carried out by authorised applicator approved by GE as per the manufacturer instructions & as directed by Engineer-in-Charge.
Dismantling of brick tiles or terracing tiles,single layer on roofs including cement motor complete all as specified and directed by Engineer-in-Charge
Dismantling of mud in roofs,any thickness,including plastering and leeping (Whether full thickness removed or only a part thereof) complete all as specified and directed by Engineer-in-Charge
M & L for RCC 1:1½:3, (nominal mix), type A-1, using 20mm graded aggregates as in Chajjas including TMT bars welded with existing steel complete all as specified and directed by Engineer-in-Charge
M & L for RCC 1:1½ :3, (nominal mix), Type A-1 using 20mm graded stone aggregates for slabs supported on walls, beams, columns and in shelves and the like complete all as specified and directed by Engineer-in-Charge
S&F for sink mixer with swinging spout (wall mounted model) chromium plated brass with connection and nut complete all as specified and directed by Engineer-in-Charge
S&F in repairs brass CP wall mixer with a point for shower for mixing hot & cold water screwed down for iron pipe complete all as specified and directed by Engineer-in-Charge
S & F in repair brass chromium plated central hole basin mixer with regular spout , popup waste system and 450mm long braided hoses with connection and nuts complete all as specified and directed by Engineer-in-Charge
S&F in repairs Vitreous china wash basin white flat back size 550 x 400mm size, pedestal incl cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe and 15mm pillar tap cast copper alloy with capstan head chromium plated complete all as specified and directed by Engineer-in-Charge
M&L for Granite (of any type) tiles18- 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete over and including 10mm thick rendering in CM 1:4, finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge
S&F for 40mm dia, cupboard knobs fixed with nut, screw and washer of mild steel, bright finished but of brass, polished complete all as specified and directed by Engineer-in-Charge
S&F for sinks made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed by Engineer-in-Charge
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in deep for foundation and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge
S&F for stainless steel sliding door bolts 300mm long modular type with bright bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed by Engineer-in-Charge.
Supply only stainless steelbutt hinges 100mm size, medium weight complete all as specified and directed by Engineer-in-Charge.
S&F for stainless steel barrel tower bolts 300mm long with bright bolt complete all as specified and directed by Engineer-in-Charge.
Supply only door closer hydraulically regulated designation No. 3, universal type, suitable for door shutter of weight between 61 to 80 Kg of aluminium (Die-Cast) body complete all as specified and directed by Engineer-in-Charge.
S&F in repairs, brass mortice lock 2 levers vertical type size 100mm complete all as specified and directed by Engineer-in-Charge.
S&F in repairs, stop valves concealed type chrome plated fancy type 15mm bore, cast copper allow screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed by Engineer-in-Charge.
M & L for PCC 1:3:6 type C-2 (using 40mm grade stone aggregate as in foundation etc and mass concrete complete all as specified and directed by Engineer-in-Charge
M&L for brick work withsub class 'B' brick on edge wall ( less than half brick wall ) in slopping wall of drain in cement mortar 1:6 incl finished pointing in CM 1:4 as the work proceeds complete all as specified and directed by Engineer-in-Charge
M & L for brick work with old size sub class 'B' bricks old size in cement mortar (1:4) straight or curved on plan exe 6 m mean radius on plan. incl finished pointing in CM 1:4 as the work proceeds complete all as specified and directed by Engineer-in-Charge
Removing excavated soil not exc 50mtr and depositing where directed at level not exc 1.50mtr above the starting point complete all as specified and directed by Engineer-in-Charge
Returning filling in trenches including spreading leveling watering and well ramming in 25cm layers complete all as specified and directed by Engineer-in-Charge
Extra for forming fair finished drain or channel 45 cm girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc complete all as specified and directed by Engineer-in-Charge
M&L for provision of soakage wells exc, in ordinary Soil, Foundation in PCC 1:3:6, wells of Honey combed and solid in M-25 Concrete, including intercepting chamber, screen chamber Brick work in CM, RCC cover slab in M-25/ RR masonry / Filling with brick bats, complete for 50 users complete all as specified and directed by Engineer-in-Charge
Taking down carefully existing aluminium/Copper point wiring light, fan socket or power bell complete with fitting such as sockets, ceiling roses, pendants batten holders regulators socket, call bells & making good to the disturbed surfaces of walls, matching the colour with existing Surface complete all as specified and directed by Engineer-in-Charge. Note: Rate for making good shall be deemed to be included in above item rate.
Taking down unserviceable main switches and MCB distribution boards single phase complete all as specified and directed by Engineer-in-Charge.
Taking down unserviceable sub main wiring and making good the disturbed surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for sand cushioning for underground cable using fine sand 8cm before laying cable and 15cm after laying and punned to 18cm after laying of cable complete all as specified and directed by Engineer-in-Charge. Note: Punned thickness shall be considered for payment purpose
Supply and laying burnt bricks sub class 'B' old size for cable protection laid length wise perpendicular to the axis of cable complete all as specified and directed by Engineer-in-Charge.
Material and labour for horizontal boring of holes including HDPE pipe 80mm bore laid under road crossing for passing of LT/HT cables in any type of soil strata by trenchless technology complete all as specified and directed by Engineer-in-Charge.
Supplying and laying GI tubing light grade 40mm bore including specials for cable protection complete all as specified and directed by Engineer-in-Charge.
Supply and laying GI tubing light grade 50mm bore including specials for cable protection complete all as specified and directed by Engineer-in-Charge.
Supply and laying GI tubing light grade 80mm bore for cable protection complete all as specified and directed by Engineer-in-Charge.
Supplying and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors/under rods/hard standing/along with poles LT cable XLPE insulated screenecd, PVC bedded, galvanised steel strip or wire armourd electric power cable (heavy duty) 1100 volt, earthed system, grade with aluminium conductor having cross sectional area 50 Sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge. Note : Excavation and earth work, sand cushioning & GIP pipe shall be measured and paid for separately
M & L for point wiring complete with 1.5 Sqmm (Nominal area) PVC insulated multustranded fire retardant (low smoke unsheathed and multicore copper conductor cable with colour code ISI marked and including PVC concealed conduict ISI marked and conduit fittings for one light point/fan point/5 Amps switch socket/bell/engagement light controlled by one switch including PVC insulated 1.5 Sqmm single core copper earth wire to common earth and connecting to earth dolly and including suitable MS sunken box of suitable size and covered with & including 3 mm thick bakelite, laminated hylem sheet top cover etc complete all as specified and directed by Engineer-in-Charge. Note : Cost of MS sunken box and bakelite sheet included in the rate
All as per Srl item No. 153 here-in-before but for one three pin socket outlet 5 Amps on the independent board complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 153 here-in-before but one three pin socket outlet 5 Amps on the same board complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 153 here in before but with 1.5 Sqmm (nominal area) PVC insulated multistranded copper conductor cable unsheathed ISI marked controlled by two way switches complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring complete with 2.5 Sqmm (Nominal area) PVC insulated multistranded fire retardant low smoke unsheated and stranded copper conductor cable ISI marked in and including PVC concealed conduit medium quality and conduit fitting for 3 pin 15 amp multipurpose switch socket combination including PVC insulated 2.5 Sqmm single core copper earth wire to common earth and connected to earth dolly and including suitable MS sunken box of suitable size and covered with & including 3 mm thick bakelite, laminated hylem sheet top cover etc complete all as specified and directed by Engineer-in-Charge.
S&F for switch Piano type single pole one way 5 Amp,230 VAC supply complete all as specified and directed by Engineer-in-Charge.
S&F for switch Piano type single pole two way 5 Amp,230 VAC supply. complete all as specified and directed by Engineer-in-Charge.
S&F for socket two in one ,3 Pin 5 Amps 230 VAC supply complete all as specified and directed by Engineer-in-Charge.
S&F for socket 6 Pin 16 amp,230 VAC complete all as specified and directed by Engineer-in-Charge.
Supply & fixing for PVC Lamp holder suitable for and including batten fittings Watt with backalite 20mm back plate complete all as specified and directed by Engineer-in-Charge.
M&L for Ceiling Rose, surface bakelite 12 to 3 terminal, 240 volts, 5 Amp ISI marked complete all as specified and directed by Engineer-in-Charge.
S&F for Electric bell ding dong complete all as specified and directed by Engineer-in-Charge.
S&F for bell push flush type 5 Amp, complete all as specified and directed by Engineer-in-Charge.
S&F for fan regulator step down electronic type heavy duly flush type 230 volts AC single phase fixed on laminated sheet top cover (laminated top cover is included in point wiring) and connecting up complete all as specified and directed by Engineer-in-Charge.
M & L for Sub main wiring with 4 single core 25 Sqmm PVC insulated FRLS cable with multicore copper conductor drawn into and including PVC conduit rigid non metallic of suitable dia with and including independent PVC insulated one run 16 Sqmm single core copper earth wire complete all as specified and directed by Engineer-in-Charge. Note:- 4 x 25 sqmm + 2 x 16 sqmm will be measured as one length
M & L for Sub main wiring with 2 single core 16 Sqmm PVC insulated FRLS cable with multicore copper conductor drawn into and including PVC conduit rigid non metallic of suitable dia with and including independent PVC insulated one run 16 Sqmm single core copper earth wire complete all as specified and directed by Engineer-in-Charge. Note:- 3 x 16 sqmm cable and will be measured as one length
M & L for Sub main wiring with 2 single core 10 Sqmm PVC insulated FRLS cable with multicore copper conductor drawn into and including PVC conduit rigid non metallic of suitable dia with and including independent PVC insulated one run 10 Sqmm single core copper earth wire complete all as specified and directed by Engineer-in-Charge. Note:- 3 x 10 sqmm cable and will be measured as one length
M & L for Sub main wiring with 2 single core 6 Sqmm PVC insulated FRLS cable with multicore copper conductor drawn into and including PVC conduit rigid non metallic of suitable dia with and including independent PVC insulated one run 6 Sqmm single core copper earth wire complete all as specified and directed by Engineer-in-Charge. Note:- 3 x 6 sqmm cable and will be measured as one length
M & L for Sub main wiring with 2 single core 4 Sqmm PVC insulated FRLS cable with multicore copper conductor drawn into and including PVC conduit rigid non metallic of suitable dia with and including independent PVC insulated one run 4.0 Sqmm single core copper earth wire complete all as specified and directed by Engineer-in-Charge. Note:- 3 x 4 sqmm cable and will be measured as one length
S&F for LED tube light fixture,environmental friendly energy efficient ready to use 18W LED 6000k (4') complete with with all electrical connection complete all as specified and directed by Engineer-in-Charge.
S&F for Batten for LED tube light fixture with extruded aluminium heat sink,environmental friendly energy efficient ready to use with 18W LED 6000K(4') including electric connection with PVC copper flexible twin core cable,1.0 Sqmm from ceiling rose to light fitting complete all as specified and directed by Engineer-in-Charge.
M&L for LED 10W bulkhead fitting with IP-43 engineering plastic housing with clear ,single phase 240V, including 1.0sqmm copper flexible cable twiested three core alongwith flelxible PVC condiut from ceiling rose to fitting testing complete all as specified and directed by Engineer-in-Charge.
S & F for MCB suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA and 5 to 32 Amps complete all as specified and directed by Engineer-in-Charge.
S & F for MCB suitable for 240 volts AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA and 16 to 32 Amps complete all as specified and directed by Engineer-in-Charge.
S & F for MCCB four Pole suitable for 200 Amp, 415 volts , 50 Hz AC supply and short circuit protection and rupturing capacity not less than 36 KA complete all as specified and directed by Engineer-in-Charge.
S & F for MCCB four Pole suitable for 250 Amp, 415 volts , 50 Hz AC supply and short circuit protection and rupturing capacity not less than 36 KA complete all as specified and directed by Engineer-in-Charge.
S & F for MCB suitable for 240 volts AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA and 63 Amps complete all as specified and directed by Engineer-in-Charge.
S & F for MCB suitable for 415 volts AC supply, TPN with over load and short circuit protection and rupturing capacity not less than 10 KA and 63 Amps complete all as specified and directed by Engineer-in-Charge.
S&F for Distribution board double door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating surface mounting SPN 4 way 240 volts with bus bar rating 200 Amps dust and vermin proof suitable for incorporation of MCB's and isolators etc complete all as specified and directed by Engineer-in-Charge.
S&F for Distribution board double door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating surface mounting SPN 8 way 240 volts with bus bar rating 200 Amps dust and vermin proof suitable for incorporation of MCB's and isolators etc complete all as specified and directed by Engineer-in-Charge.
S&F for Distribution board double door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating surface mounting TPN DB 4 way 240 volts with bus bar rating 200 Amps dust and vermin proof suitable for incorporation of MCB's and isolators etc complete all as specified and directed by Engineer-in-Charge.
S&F for heavy duty Exhaust fan 300mm sweep mounted in suitable opening arrangement with self closing louvers shutters suitable for operation on 230 volts, single phase, 50 cycle per second, AC supply and connecting up including three core PVC insulated PVC sheated copper conductor flexible cable 24/0.2mm drawn in flexible PVC conduit and fixed by using 4 Nos. 200mm long 12mm dia bolts, nuts and washers and grouted in wall in CM 1:3 complete all as specified and directed by Engineer-in-Charge.
S&F for Exhaust fan heavy duty 450mm sweep mounted in suitable opening arrangement with louvers shutters suitable for operation on 230 volts, single phase, 50 cycle per second, AC supply and connecting up including three core PVC insulated PVC sheated copper conductor flexible cable 24/0.2mm drawn in flexible PVC conduit and fixed by using 4 Nos. 200mm long 12mm dia bolts, nuts and washers and grouted in wall in CM 1:3 complete all as specified and directed by Engineer-in-Charge.
Earthing complete with galvanised steel earth platge electroe 60 cmx60cm6mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below normal round level) with edge of the plae not less than 1.5 mtr below normal ground level, connected to galvanized earth lead wire 4mm dia by means of bolts, nuts, check nuts and GI washers earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15cm thick all around bottom and top of earth plate as shown in electrical piate No. 3 of SSR Part-I and connecting to earthing test point and testing on completion including PCC 1:3:6 type C2 for earthing pit, GI light grade protection pipe of size 15mm dia, watering pipe 20mm bore medium grade, CI cover and frame necessary earth works and PCC work etc complete all as specified. Earth plate shall be surrounded by alternate layer of charcoal of coke and common salt 15cm thick alround the earth plate including bottom and top complete all as specified and directed by Engineer-in-Charge. Note: PCC chamber shall be constructed at least 1.5mtr away from the earth electrod and pipe for watering shall be slanting manner --------------------------------------------------------------------------------------------------- Note : A sum of Rs. 2,02,455.00 will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 41 & 42(R) (Schedule of Credit) of Tender document
M/S Yashpaul Gulati
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .