Electrification work in connection with "Provision of monitoring facility for digital & electronic equipments in LHB & VB coaches and upgradation of staff rooms & existing rooms of DCWTC building at coaching depot, AGC".
T-06-N-2026-27
T-06-N-2026-27
Open
8 Months
Unknown (Unspecified Location)
₹0
₹38,400
15 May 2026
15 May 2026
29 May 2026
A-Electrification work in connection with "Provision of monitoring facility
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm 1 FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group A (1.10.1)
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. Size 2 X 6 sq. mm + 1 X 6 sq. mm earth wire (1.14.4)
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. Size2 X 10 sq. mm + 1 X 6 sq. mm earth wire (1.14.5)
Supplying and fixing following modular switch/ socket modular plate with inner or front plate, box & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch (1.24.1)
Supplying and fixing following modular switch/ socket modular plate with inner or front plate, box & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet (1.24.5)
Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. (5.2)
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, modular with 2 7 pole and earth, metal enclosed plug top along with modular 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required and conforming to CPWD General Specifications for Electrical Works. (2.18)
Supply, fixing, testing and commissioning of wall mounted LT distribution board made 8 up of steel sheet, phosphatized powder painted complete with neutral link, earth point, Din rail and prewired confirming to IS:13032& 8623:1991 with following items of matching make to be fixed in distribution board, confirming to IS:8828 :1996 or latest, IE rules and site requirement. TPN MCB63 Amps. 10 kA 'C' series= 01No. (Incoming) SP MCB 6-32Amps. 10 kA 'C' series = 18 Nos.(Outgoing)
Supply, Erection, Testing & Commissioning of 5 star rated super energy saving efficient BLDC Ceiling Fan, sweep size1200mm., down rod length asper site requirement, power 9 factor greater than 0.98 with Electronic Regulator & double ball bearing and MS Flat size50 X 5mm clamp of suitable size with hanging hook, nut bolt washer etc & Connection shall be taken with twin cord flexible PVC insulated copper wire size 48/0.2 mm., 03blades of Aluminium with power consumption not more than 28 Watt, Warranty 03years, required. 5 star rated BLDC super energy efficient ceiling Fan with double ball bearing, power 28 W. cat-Fan super efficient-ceiling BLDC
Supply, Erection, Testing & Commissioning of luminaire complete with all accessories, 10 18/20 watt, 04 feet LED tube light fitting & Tube with suitable current control driver circuit, suitable for surface mounting and connection with PVC copper flexible wire of 23/76 as per Rly. specification attached.
Supply, Erection, testing and commissioning of earth electrode with 600X600X6mm 11 thick copper plate earth electrode as per IS3043/1987 (Latest version), to achieve earth resistance less than one ohm including construction of masonry in closer with hinged cover plate of cast iron with locking arrangement on top watering pipe connection from earth plate to top with 50mm dia X 3000mm GI pipe class B and provision of eath plate
Supply, fixing, testing & commissioning of MCB DB single phase with RCBO, m.s. enclosure, I/C -DP RCBO of 40Amp - 1No, O/G: SP MCB of 6A - 32A - 8Nos, as per specifications. 30 mA
Supply, Erection, testing and Commissioning of LT control panel outdoor, cubical floor mounted Hut type dust and vermin proof multi layer construction, weather proof proper ventilation arrangement, outdoor type LT distribution board for operation on 3 phase 4-wire, 415V AC supply system recondition with 14 SWG MS sheet base MS angle 50x50x6 mm MS Channel 75x40x6 mm. It 13 shall be coated with 2 coats approved colour. The LT panel shall be of front operated with copper conductor cable, cable glands, earthing studs, feeder, name plate and danger board on front. The LT panel shall be erected on the floor. The panel shall comprises of 400 Amps copper bus bar with protection equipment, 01 Number incoming side 250A MCCB 50KA, 4X100 A MCCB 36KA, 2X63A MCCB 30KA and 05 Nos. 32A MCCB 3OKA. All MCCB should be 4-pole type voltmeter, Ammeter indicating lamps shall be fitted all incoming and outgoing side camplete with locking arrangement and all other required accessories as per site""
Supply, Erection, Testing & Commissioning of wall mounted Sub Distribution Board (Light/power) TP&N Vertical Three Phase wall mounting type 4 way peari ivory dust and vermin proof 14 in door type factory fabricated from sheet steel enclosure (1.6 mm. thick ivory colour) 04 way fitted with double door copper bus bar, neutral link, earth terminal detachable glands fitted with following item. (SDB make as per attached approved list) 01 No. 125Amp. 50 KA MCB-TPN-on incoming side. 12 Nos 16 to 32Amp. MCB-SP- on out goingside.
Supply, erection, testing and commissioning of Metal clad08 way SDB complete with 40Amps.MCB Dp on I/C side &O/G side 4x20/25 Amps MCBSP, 2x10/16 Amps. MCB SP with all other accessories required as per site.
Supply, fixing, connecting and commissioning ofsplit AC of capacity 2.0 Ton inverter type variablespeed, Nominal Cooling Capacity (KCal/Hr): 6000suitable for 230 volt, AC 1 Phase, 16 Material forbody of indoor unit: ABS, Min. Room DischargeAir flow (Cum/Hr): 700, Guaranteed Cooing Capacity (Min) KCal/Hr: 4275 Operation onecofriendly refrigerant R-32 or R-410a, coppermaterial of evaporator and condenser with wallmounting arrangement, confirming to IS:1391Part-II with latest amendment up to dated StarRating -5.
Digital Two AC Timer for window/split AC for 1.5/2.0 T R/3.0TReach (DIGITAL DISPLAY 17 LCD MODEL) LCD Model latest intelligent Microcontroller based Technology (3 AC TIMER) program-1 hr to 24 hrs with 30 amps Heavy Duty 2 relay output for Two AC Auto/Manual facility for Three phase/single phase HI WALL ORCASSETE TYPE OR DUCTABLE TYPE AC, Dynamic/Saitech System/Om Energy Savers /BELL Nutronics Make.
Supply, Erection, testing and commissioning of Heavy duty powder coated stand for outdoor unit of split type AC
Supply, Erection, Testing and commissioning of Termination kit of LT-XLPE cable of various size. (as per site requirement)
Horizontal boring of cableduct at 1.4 to 2.1 mtr.depth from the bottom of 20 sleeper/ground lable and laying of120 mm dia HDPE DWC pipesfor cable crossing under track/ road .The work shall bedone as per extant practiceand instruction of site engineer.It includes supply of DWC/HDPE pipes conforming to IS14930(Part:2:2001)
Laying/Cleating erection,Testing & Commissioning of HT/LT Cable 03/04 Core on wall with all accessories & refilling of cable trench (asper IE rule) after laying of cable (Cable will be supplied by Rly free of cost at Consignee Depot)
Excavation of cable trench:-This item shall be operated in conformity with IS:1255(latest version) i.e. code of practice for installation and maintenance of HT/LT cables.The price shall cover cost of excavation of cable trench inall type of soil for laying LTcables and back filling thesame with sieved earth and finishing the surface in its original condition after providing sand, & bricks in cross position. For LT/HTcables the trench shall be 600mm wide x 1000mmdeep. In 22 trench the cable shall be covered with riversand at a depth of 100mm below the cable and 100mm above the cable than placing well-burned bricks continuously in cross position through out the cable route inthe ground. The bottom ofthe trench should level freefrom stones and sharp edgeof rocks etc. At the termination a loop of 5 meter(approx) cable shall be keptas allowance and loops ringsbe formed as per the site condition, in the ground, The cost shall include the cost ofall materials i.e. sand, bricks,cable route markers (groutedin the earth firmly with cement concrete so that itcan not be uprooted by miscreants) etc at 25m.interval and each turn of the cable.
Supply, Erection, Testing and commissioning of hot dip galvanized octagonal pole 5 23 Mtr. long confirming to IS 2629/BSEN ISO 1461 or equivalent including casting, muffing with cement concrete foundation (1:2:4) painting, earthing etc. the pole shall be complete with holes, Anchor bolts, bottom plate etc. As per Tech. Specification/site requirement, IS/IE rules of Double Arm type with 1.5 feet to 2 feet long type
supply, erection, Testing & Commissioning of energy efficient LED street light fitting 24 60 Watt outdoor complete street light fitting pressure die cast aluminium (PDC) body with make embosed on PDC body and complete with all accessories/ components and connection with PVC copper wire 2.5sq.mm size multicore and fixing arrangement as persite requirement.The technical parameters will generally conform to relevant Railway specification attached Annexure-II
"Supply, Erection, Testing and commissioning of 200mm ventilating fan."
Supplying, testing &commissioning of heavy duty bracket type 750 mm sweep air circulator fan single phase RPM 2800three blades suitable for230 V 50 Hz without regulator AC 26 supply havingair replacement 370 cm per minutes. The propeller should be cast aluminium Yellow &conforming to IS:2997/64 with amendment 1to 5 air- circulating fan should be wall mounting. The air circulating fan willbe mounted/fixed on MSpillar (in shed) with MS flats50x6 mm size clamps bolts & nuts complete in all respect.
Supply, Erection, Testing and commissioning of40Watt LED 2X2colour temperature(+/-500K)-6000 DegK Ceiling mounting type
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Letterofcredit.pdf
ATTACHMENT
t-06-n-2026-27_1.pdf
ATTACHMENT
GCCApril202227-04-2022.pdf
ATTACHMENT
GCCACScorrectionslip1.pdf
ATTACHMENT
correctionslipNo.-02GCC13-12-22.pdf
ATTACHMENT
CorrectionslipNo.-03ofGCC-2022.pdf
ATTACHMENT
GCCCorrection07-08-2023SlipNo.4.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_5ACS-5.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_6ACS-6.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_7ACS-7.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo-8.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo-9.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo-10.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_11_compressed.pdf gcccorrectionslip11
ATTACHMENT
AnnexureC.pdf
ATTACHMENT
AnnexureVA1Policy.pdf
ATTACHMENT
Shramikkalyan.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_11_compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid